Ubiquiti EdgeSwitch Hardware
Description
It monitors the temperature sensor state along with the temperature value.And operational state of FAN.This state means the fan is present but no AC is connected. Possible values are notpresent(1),operational(2),failed(3), powering(4),nopower(5),notpowering(6),incompatible(7) [EdgeSwitch-BOXSERVICES-PRIVATE-MIB :: boxServicesFansIndex : 1.3.6.1.4.1.4413.1.1.43.1.6.1.1, boxServicesFanItemState : 1.3.6.1.4.1.4413.1.1.43.1.6.1.3] [EdgeSwitch-BOXSERVICES-PRIVATE-MIB :: boxServicesUnitIndex : 1.3.6.1.4.1.4413.1.1.43.1.8.1.1, boxServicesTempSensorState : 1.3.6.1.4.1.4413.1.1.43.1.8.1.4,boxServicesTempSensorTemperature : 1.3.6.1.4.1.4413.1.1.43.1.8.1.5].
Prerequisites
Device should support EdgeSwitch-BOXSERVICES-PRIVATE-MIB , EdgeSwitch-SWITCHING-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Ubiquiti EdgeSwitch FAN Status | ubiquiti_edgeswitch_fan_Status | Ubiquiti EdgeSwitch FAN Status | It monitors the operational state of FAN.[EdgeSwitch-BOXSERVICES-PRIVATE-MIB :: boxServicesFansIndex : 1.3.6.1.4.1.4413.1.1.43.1.6.1.1, boxServicesFanItemState : 1.3.6.1.4.1.4413.1.1.43.1.6.1.3].Possible values are notpresent(1),operational(2),failed(3), powering(4),nopower(5),notpowering(6),incompatible(7) | |
Ubiquiti EdgeSwitch Temperature | ubiquiti_edgeswitch_temperature_Status | Ubiquiti EdgeSwitch Temperature Status | It monitors the temperature sensor state. [EdgeSwitch-BOXSERVICES-PRIVATE-MIB :: boxServicesUnitIndex : 1.3.6.1.4.1.4413.1.1.43.1.8.1.1, boxServicesTempSensorState : 1.3.6.1.4.1.4413.1.1.43.1.8.1.4]. Possible value are low(0),normal(1),warning(2),critical(3),shutdown(4),notpresent(5),notoperational(6) | |
ubiquiti_edgeswitch_temperature_Value | Ubiquiti EdgeSwitch Temperature Value | Celsius | It monitors the temperature sensor state along with the temperature value. [EdgeSwitch-BOXSERVICES-PRIVATE-MIB :: boxServicesUnitIndex : 1.3.6.1.4.1.4413.1.1.43.1.8.1.1, boxServicesTempSensorTemperature : 1.3.6.1.4.1.4413.1.1.43.1.8.1.5] |
Ubiquiti EdgeSwitch Performance
Description
It onitors the memory utilization from the given total and Available memory. [EdgeSwitch-SWITCHING-MIB :: agentSwitchCpuProcessMemFree : 1.3.6.1.4.1.4413.1.1.1.1.4.1.0 , agentSwitchCpuProcessMemAvailable : 1.3.6.1.4.1.4413.1.1.1.1.4.2.0, agentSwitchCpuProcessTotalUtilization : 1.3.6.1.4.1.4413.1.1.1.1.4.9.0]
Prerequisites
Device should support EdgeSwitch-BOXSERVICES-PRIVATE-MIB , EdgeSwitch-SWITCHING-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Ubiquiti EdgeSwitch CPU Utilization | ubiquiti_edgeswitch_cpu_Utilization | Ubiquiti EdgeSwitch CPU Utilization | % | It monitors the total cpu utilization over a period of 5 minutes. [EdgeSwitch-SWITCHING-MIB :: agentSwitchCpuProcessTotalUtilization : 1.3.6.1.4.1.4413.1.1.1.1.4.9.0] |
Ubiquiti EdgeSwitch Memory Utilization | ubiquiti_edgeswitch_memory_Utilization | Ubiquiti Edge Switch Memory Utilization | % | It provides the total memory utilization on the ubiquiti edge switch. [EdgeSwitch-SWITCHING-MIB :: agentSwitchCpuProcessMemFree : 1.3.6.1.4.1.4413.1.1.1.1.4.1.0 , agentSwitchCpuProcessMemAvailable : 1.3.6.1.4.1.4413.1.1.1.1.4.2.0] |