Ubiquiti EdgeSwitch Hardware

Description

It monitors the temperature sensor state along with the temperature value.And operational state of FAN.This state means the fan is present but no AC is connected. Possible values are notpresent(1),operational(2),failed(3), powering(4),nopower(5),notpowering(6),incompatible(7) [EdgeSwitch-BOXSERVICES-PRIVATE-MIB :: boxServicesFansIndex : 1.3.6.1.4.1.4413.1.1.43.1.6.1.1, boxServicesFanItemState : 1.3.6.1.4.1.4413.1.1.43.1.6.1.3] [EdgeSwitch-BOXSERVICES-PRIVATE-MIB :: boxServicesUnitIndex : 1.3.6.1.4.1.4413.1.1.43.1.8.1.1, boxServicesTempSensorState : 1.3.6.1.4.1.4413.1.1.43.1.8.1.4,boxServicesTempSensorTemperature : 1.3.6.1.4.1.4413.1.1.43.1.8.1.5].

Prerequisites

Device should support EdgeSwitch-BOXSERVICES-PRIVATE-MIB , EdgeSwitch-SWITCHING-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Ubiquiti EdgeSwitch FAN Statusubiquiti_edgeswitch_fan_StatusUbiquiti EdgeSwitch FAN StatusIt monitors the operational state of FAN.[EdgeSwitch-BOXSERVICES-PRIVATE-MIB :: boxServicesFansIndex : 1.3.6.1.4.1.4413.1.1.43.1.6.1.1, boxServicesFanItemState : 1.3.6.1.4.1.4413.1.1.43.1.6.1.3].Possible values are notpresent(1),operational(2),failed(3), powering(4),nopower(5),notpowering(6),incompatible(7)
Ubiquiti EdgeSwitch Temperatureubiquiti_edgeswitch_temperature_StatusUbiquiti EdgeSwitch Temperature StatusIt monitors the temperature sensor state. [EdgeSwitch-BOXSERVICES-PRIVATE-MIB :: boxServicesUnitIndex : 1.3.6.1.4.1.4413.1.1.43.1.8.1.1, boxServicesTempSensorState : 1.3.6.1.4.1.4413.1.1.43.1.8.1.4]. Possible value are low(0),normal(1),warning(2),critical(3),shutdown(4),notpresent(5),notoperational(6)
ubiquiti_edgeswitch_temperature_ValueUbiquiti EdgeSwitch Temperature ValueCelsiusIt monitors the temperature sensor state along with the temperature value. [EdgeSwitch-BOXSERVICES-PRIVATE-MIB :: boxServicesUnitIndex : 1.3.6.1.4.1.4413.1.1.43.1.8.1.1, boxServicesTempSensorTemperature : 1.3.6.1.4.1.4413.1.1.43.1.8.1.5]

Ubiquiti EdgeSwitch Performance

Description

It onitors the memory utilization from the given total and Available memory. [EdgeSwitch-SWITCHING-MIB :: agentSwitchCpuProcessMemFree : 1.3.6.1.4.1.4413.1.1.1.1.4.1.0 , agentSwitchCpuProcessMemAvailable : 1.3.6.1.4.1.4413.1.1.1.1.4.2.0, agentSwitchCpuProcessTotalUtilization : 1.3.6.1.4.1.4413.1.1.1.1.4.9.0]

Prerequisites

Device should support EdgeSwitch-BOXSERVICES-PRIVATE-MIB , EdgeSwitch-SWITCHING-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Ubiquiti EdgeSwitch CPU Utilizationubiquiti_edgeswitch_cpu_UtilizationUbiquiti EdgeSwitch CPU Utilization%It monitors the total cpu utilization over a period of 5 minutes. [EdgeSwitch-SWITCHING-MIB :: agentSwitchCpuProcessTotalUtilization : 1.3.6.1.4.1.4413.1.1.1.1.4.9.0]
Ubiquiti EdgeSwitch Memory Utilizationubiquiti_edgeswitch_memory_UtilizationUbiquiti Edge Switch Memory Utilization%It provides the total memory utilization on the ubiquiti edge switch. [EdgeSwitch-SWITCHING-MIB :: agentSwitchCpuProcessMemFree : 1.3.6.1.4.1.4413.1.1.1.1.4.1.0 , agentSwitchCpuProcessMemAvailable : 1.3.6.1.4.1.4413.1.1.1.1.4.2.0]