Storage-EMC - Data Domain - DDOS v5.4.0.8
Description
Applicable on the data domain storage devices. Monitors the disk, filesystem, power module status, temperature status, system statistics etc.. Data Domain OS 5.4.0.8-404909. SNMP Obj Id=1.3.6.1.4.1.19746.3.1.36. . Open TCP ports[139,443,80,22,]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
DD Disk Status - DDOS V5.4.0.8 | dd.system.disk.errstatus | DD Disk Status - DDOS V5.4.0.8 | Provides the current state of the disk. Possible status values are 1- Ok, 2- Unknown, 3- Absent, 4- Failed, 5- Spare, 6- Available. [OID: 1.3.6.1.4.1.19746.1.6.3.1.1.3, 1.3.6.1.4.1.19746.1.6.3.1.1.14] | |
DD FAN Sensor Status - DDOS V5.4.0.8 | dd.fan.sensor.status | DD FAN Sensor Status - DDOS V5.4.0.8 | Provides the current status of the fan. Possible status values are 0 - Not Found, 1 - Ok, 2 - Failed. [OID: 1.3.6.1.4.1.19746.1.1.3.1.1.1.4, 1.3.6.1.4.1.19746.1.1.3.1.1.1.6] | |
DD File System Space Used - DDOS V5.4.0.8 | dd.filesystem.utilization | DD File System Space Used - DDOS V5.4.0.8 | % | Provides the percentage of used space within the file system resource. [OID: 1.3.6.1.4.1.19746.1.3.2.1.1.3, 1.3.6.1.4.1.19746.1.3.2.1.1.7] |
DD File System Status - DDOS V5.4.0.8 | dd.filesystem.status | DD File System Status - DDOS V5.4.0.8 | Provides the status of the data domain file system. Possible status values are 1- Enabled, 2- Disabled, 3- Running, 4- Unknown, 5- Error, 6- Cleaning. [OID: 1.3.6.1.4.1.19746.1.3.1.1.0] | |
DD NVRAM Battery Status - DDOS V5.4.0.8 | dd.nvram.battery.status | DD NVRAM Battery Status - DDOS V5.4.0.8 | Provides the NVRAM battery status of the data domain. Possible status values are 0- Ok, 1- Disabled, 2- Discharged, 3- Unknown, 4- Softdisabled. [OID: 1.3.6.1.4.1.19746.1.2.3.1.1.2,\n1.3.6.1.4.1.19746.1.2.3.1.1.3] | |
DD Power Module Status - DDOS V5.4.0.8 | dd.power.module.status | DD Power Module Status - DDOS V5.4.0.8 | Provides the power module status of data domain. Possible status values are 0- Absent, 1 - Ok, 2- Failed, 3- Faulty, 4- Acnone, 99- Unknown. [OID: 1.3.6.1.4.1.19746.1.1.1.1.1.1.2,\n1.3.6.1.4.1.19746.1.1.1.1.1.1.4] | |
DD Replication Status - DDOS V5.4.0.8 | dd.replicationstate.advanced2 | DD Replication State - DDOS V5.4.0.8 | Provides the state of the replication source/dest pair connection. Possible status values for state are: 1- Initializing, 2- Normal, 3- Recovering, 4- Uninitialized. | |
dd.replicationstatus.advanced2 | DD Replication Status - DDOS V5.4.0.8 | Provides the status of the replication source/dest pair connection. Possible status values for status are: 1- Connected, 2- Disconnected, 3- Migrating, 4- Suspended, 5- NeverConnected, 6- Idle.[OID: 1.3.6.1.4.1.19746.1.8.1.1.1.1, 1.3.6.1.4.1.19746.1.8.1.1.1.4]\n | ||
DD System Statistics - DDOS V5.4.0.8 | dd.system.cpu.max | DD System CPU Max - DDOS V5.4.0.8 | % | CPU Max Percentage Busy. [OID: 1.3.6.1.4.1.19746.1.5.1.1.1.3] |
dd.system.cpu.avg | DD System CPU Average - DDOS V5.4.0.8 | % | CPU Average Percentage Busy. [OID: 1.3.6.1.4.1.19746.1.5.1.1.1.2] | |
dd.disk.busy.percent | DD Disk Busy Percent - DDOS V5.4.0.8 | % | Percentage of Time Disks were busy. [OID: 1.3.6.1.4.1.19746.1.5.1.1.1.12] | |
dd.nfs.oper.persec | NFS Operations - DDOS V5.4.0.8 | psec | Number of NFS Operations performed per second. [OID: 1.3.6.1.4.1.19746.1.5.1.1.1.4] | |
DD Temperature Sensor Status - DDOS V5.4.0.8 | dd.temp.sensor.currentvalue | DD Temperature Sensor Value - DDOS V5.4.0.8 | C | Current Temperature Value of the sensor. [OID: 1.3.6.1.4.1.19746.1.1.2.1.1.1.5] |
dd.temp.sensor.status | DD Temperature Sensor Status - DDOS V5.4.0.8 | Provides the status the temperature sensor. Possible status values are 0- Failed, 1- Ok, 2- Notfound, 3- OverheatWarning, 4- OverheatCritical. [OID: 1.3.6.1.4.1.19746.1.1.2.1.1.1.4,\n1.3.6.1.4.1.19746.1.1.2.1.1.1.6] |
Storage-EMC-Xtremio Cluster Array
Description
G2-Storage-EMC-Xtremio Cluster Array
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
EMC Xtremio Battery Monitor | xtremio.cluster.bbu.ups-input | BBU Input | Battery Input | |
xtremio.cluster.bbu.fru-lifecycle-state | BBU Lifecycle State | Battery Lifecycle State | ||
xtremio.cluster.bbu.ups-conn-state | BBU Connection State | Battery Connection State | ||
xtremio.cluster.bbu.ups-battery-charge-in-percent | Battery Charge in Percent | % | Battery Charge in Percent | |
xtremio.cluster.bbu.ups-load-in-percent | BBU Load in Percent | % | Battery Load in Percent | |
xtremio.cluster.bbu.ups-load-percent-level | BBU Load Level | Battery Load Level | ||
EMC Xtremio Cluster Monitor | xtremio.array.cluster.overall-efficiency | Cluster Overall Efficiency | Cluster Overall Efficiency | |
xtremio.array.cluster.sys-health-state | Cluster Health State | Cluster Health State | ||
xtremio.array.cluster.sys-state | Cluster State | Cluster State | ||
xtremio.array.cluster.sys-mgr-conn-state | Cluster Connection State | Cluster Connection State | ||
xtremio.array.cluster.data-reduction-ratio | Cluster Data Reduction Ratio | Cluster Data Reduction Ratio | ||
xtremio.array.cluster.space-saving-ratio | Cluster Space Saving Ratio | Cluster Space Saving Ratio | ||
xtremio.array.cluster.dedup-ratio | Cluster Deduplication Ratio | Cluster Deduplication Ratio | ||
xtremio.array.cluster.compression-factor | Cluster Compression Reduction Ratio | Cluster Compression Reduction Ratio | ||
xtremio.array.cluster.thin-provisioning-ratio | Cluster Thin Provisioning Saving | % | Cluster Thin Provisioning Saving | |
xtremio.array.cluster.vol-size | Cluster Volume Capacity | GB | Cluster Volume Capacity | |
xtremio.array.cluster.logical-space-in-use | Cluster Volume Used Space | Gb | Cluster Volume Used Space | |
xtremio.array.cluster.volume-percent-used | Cluster Volume Percent Used | % | Cluster Volume Percent Used | |
xtremio.array.cluster.volume-free-space | Cluster Volume Free Space | GB | Cluster Volume Free Space | |
xtremio.array.cluster.volume-free-percent | Cluster Volume Free Percent | % | Cluster Volume Free Percent | |
xtremio.array.cluster.ud-ssd-space | Cluster Physical Capacity | GB | Cluster Physical Capacity | |
xtremio.array.cluster.ud-ssd-space-in-use | Cluster Physical Space in Use | GB | Cluster Physical Space in Use | |
xtremio.array.cluster.physical-percent-used | Cluster Physical Percent Used | % | Cluster Physical Percent Used | |
xtremio.array.cluster.physical-free-space | Cluster Physical Free Space | GB | Cluster Physical Free Space | |
xtremio.array.cluster.free-ud-ssd-space-in-percent | Cluster Physical Free Percent | % | Cluster Physical Free Percent | |
xtremio.array.cluster.totalbandwidth | Cluster Total Bandwidth | KBps | Cluster Total Bandwidth | |
xtremio.array.cluster.readbandwidth | Cluster Read Bandwidth | KBps | Cluster Read Bandwidth | |
xtremio.array.cluster.writebandwidth | Cluster Write Bandwidth | KBps | Cluster Write Bandwidth | |
xtremio.array.cluster.iops | Cluster Total IOPS | Cluster Total IOPS | ||
xtremio.array.cluster.rd-iops | Cluster Read IOPS | Cluster Read IOPS | ||
xtremio.array.cluster.wr-iops | Cluster Write IOPS | Cluster Write IOPS | ||
xtremio.array.cluster.avg-latency | Cluster Total Latency | ms | Cluster Total Latency | |
xtremio.array.cluster.rd-latency | Cluster Read Latency | ms | Cluster Read Latency | |
xtremio.array.cluster.wr-latency | Cluster Write Latency | ms | Cluster Write Latency | |
EMC Xtremio DAE Controller Monitor | xtremio.cluster.daecontroller.fru-lifecycle-state | DAE Controller Lifecycle State | DAE Controller Lifecycle State | |
xtremio.cluster.daecontroller.enabled-state | DAE Controller Enabled State | DAE Controller Enabled State | ||
xtremio.cluster.daecontroller.sas1-port-state | DAE Controller SAS1 Port State | DAE Controller SAS1 Port State | ||
xtremio.cluster.daecontroller.sas2-port-state | DAE Controller SAS2 Port State | DAE Controller SAS2 Port State | ||
EMC Xtremio Data Protection Group Monitor | xtremio.cluster.dataprotectiongroup.protection-state | DP Group Protection State | Data Protection Group Protection State | |
xtremio.cluster.dataprotectiongroup.ssd-size | DP Group Total SSD Size | GB | Data Protection Group Total SSD Size | |
xtremio.cluster.dataprotectiongroup.useful-ssd-space | DP Group Useful SSD Space | GB | Data Protection Group Useful SSD Space | |
xtremio.cluster.dataprotectiongroup.ud-ssd-space | DP Group User Space | GB | Data Protection Group User Space | |
xtremio.cluster.dataprotectiongroup.ud-ssd-space-in-use | DP Group In Use User Space | GB | Data Protection Group In Use User Space | |
xtremio.cluster.dataprotectiongroup.rg-ud-ssd-percent-free-space | DP Group Free User Space Percent | % | Data Protection Group Free User Space Percent | |
EMC Xtremio Disk Array Enclosure Monitor | xtremio.cluster.dae.fru-lifecycle-state | DAE Lifecycle State | DAE Lifecycle State | |
EMC Xtremio Disk Monitor | xtremio.cluster.ssd.fru-lifecycle-state | SSD FRU Lifecycle State | SSD FRU Lifecycle State | |
xtremio.cluster.ssd.ssd-size-in-kb | SSD Capacity GB | GB | SSD Capacity GB | |
xtremio.cluster.ssd.ssd-space-in-use | SSD Used GB | GB | SSD Used GB | |
xtremio.cluster.ssd.ssd-percent-used | SSD Percent Used | % | SSD Percent Used | |
xtremio.cluster.ssd.percent-endurance-remaining | SSD Percent Endurance Remaining | % | SSD Percent Endurance Remaining | |
xtremio.cluster.ssd.ssd-failure-reason | SSD Failure Reason | SSD Failure Reason | ||
xtremio.cluster.ssd.bandwidth | SSD Total Bandwidth | KBps | SSD Total Bandwidth | |
xtremio.cluster.ssd.readbandwidth | SSD Read Bandwidth | KBps | SSD Read Bandwidth | |
xtremio.cluster.ssd.writebandwidth | SSD Write Bandwidth | KBps | SSD Write Bandwidth | |
xtremio.cluster.ssd.iops | SSD Total IOPS | SSD Total IOPS | ||
xtremio.cluster.ssd.rd-iops | SSD Read IOPS | SSD Read IOPS | ||
xtremio.cluster.ssd.wr-iops | SSD Write IOPS | SSD Write IOPS | ||
EMC Xtremio Infiband Switch Monitor | xtremio.cluster.infibandswitch.fru-lifecycle-state | Infiband Switch Lifecycle State | Infiband Switch Lifecycle State | |
EMC Xtremio Initiator Group Monitor | xtremio.cluster.initiatorgroup.totalbandwidth | Igrp Total Bandwidth | KBps | Initiator Group Total Bandwidth |
xtremio.cluster.initiatorgroup.readbandwidth | Igrp Read Bandwidth | KBps | Initiator Group Read Bandwidth | |
xtremio.cluster.initiatorgroup.writebandwidth | Igrp Write Bandwidth | KBps | Initiator Group Write Bandwidth | |
xtremio.cluster.initiatorgroup.iops | Igrp Total IOPS | Initiator Group Total IOPS | ||
xtremio.cluster.initiatorgroup.rd-iops | Igrp Read IOPS | Initiator Group Read IOPS | ||
xtremio.cluster.initiatorgroup.wr-iops | Igrp Write IOPS | Initiator Group Write IOPS | ||
EMC Xtremio Storage Controller Monitor | xtremio.cluster.storagecontroller.fru-lifecycle-state | Controller Lifecycle State | Controller Lifecycle State | |
xtremio.cluster.storagecontroller.node-health-state | Controller Health State | Controller Health State | ||
xtremio.cluster.storagecontroller.enabled-state | Controller Enabled State | Controller Enabled State | ||
xtremio.cluster.storagecontroller.node-mgr-conn-state | Conrtoller Connection State | Controller Connection State | ||
xtremio.cluster.storagecontroller.sas1-port-state | Controller SAS1 Port State | Controller SAS1 Port State | ||
xtremio.cluster.storagecontroller.sas2-port-state | Controller SAS2 Port State | Controller SAS2 Port State | ||
EMC Xtremio Target Monitor | xtremio.cluster.target.port-state | Target Port State | Target Port State |
Storage-EMC-XtremIO Cluster Array-Storage Controller
Description
Monitors the Storage Controller health and performance metrics.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
EMC Xtremio Storage Controller Monitor | xtremio.cluster.storagecontroller.fru-lifecycle-state | Controller Lifecycle State | Controller Lifecycle State | |
xtremio.cluster.storagecontroller.node-health-state | Controller Health State | Controller Health State | ||
xtremio.cluster.storagecontroller.enabled-state | Controller Enabled State | Controller Enabled State | ||
xtremio.cluster.storagecontroller.node-mgr-conn-state | Conrtoller Connection State | Controller Connection State | ||
xtremio.cluster.storagecontroller.sas1-port-state | Controller SAS1 Port State | Controller SAS1 Port State | ||
xtremio.cluster.storagecontroller.sas2-port-state | Controller SAS2 Port State | Controller SAS2 Port State |