NEC - PDM Health

Description

Template to monitor NEC PDM(Projector and Display Management) Health parameters like Fan Status,Light Source Status,Temperature Sensor status,Temperature Sensor Value.

Prerequisites

Device should have support for PWG-PROJECTOR-DISPLAY-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
NEC - PDM Fannec.pdm.fan.statusPDM Fan StatusIt monitors the PDM(Projector and Display Management) fan status. Possible values are 1: other,2: unknown,3: okay,4: warning,5: tooFastFail,6: tooSlowFail,7: slowStartWarning.[PWG-PROJECTOR-DISPLAY-MIB::pdmFanStatus:1.3.6.1.4.1.2699.1.4.1.8.1.1.3].
NEC - PDM Light Sourcenec.pdm.light.source.statusPDM Light Source StatusIt monitors the PDM(Projector and Display Management) light source status. Possible values are 1: other,2: unknown,3: okay,4: failed.[PWG-PROJECTOR-DISPLAY-MIB::pdmLightSourceStatus:1.3.6.1.4.1.2699.1.4.1.7.1.1.3].
NEC - PDM Temperature Sensornec.pdm.temp.sensor.statusPDM Temperature Sensor StatusIt monitors the PDM(Projector and Display Management) temperature sensor status. Possible values are 1: other,2: unknown,3: okay,4: warning,5: hiTempLimitFail,6: lowTempLimitFail.[PWG-PROJECTOR-DISPLAY-MIB::pdmTempSensorStatus:1.3.6.1.4.1.2699.1.4.1.10.1.1.3].
nec.pdm.temp.sensor.valuePDM Temperature Sensor ValueCelsiusIt monitors the PDM(Projector and Display Management) temperature sensor value in degree Celsius.[PWG-PROJECTOR-DISPLAY-MIB::pdmTempSensorTemp:1.3.6.1.4.1.2699.1.4.1.10.1.1.4].

NEC Express Cluster Status - G2

Description

It monitors the each cluster server and current status of cluster.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
NEC Cluster Server Statusnec.cluster.server.statusCluster Server StatusThe current status of each cluster server. Possible values for this monitor are 1- normal,2- online,3- offline,4- caution,5- error,6- onlineFailure,7- offlineFailure,8- onlinePending,9- offlinePending,10- unknown,11- suspend,12- pending,13- isolated,14- unused. Generates critical alert if value is other than 1 or 2.[OIDs: 1.3.6.1.4.1.119.2.3.207.1.2.2.2.1.2,1.3.6.1.4.1.119.2.3.207.1.2.2.2.1.4]
NEC Cluster Statusnec.cluster.statusCluster StatusThe current status of cluster. Possible values for this monitor are 1- normal,2- online,3- offline,4- caution,5- error,6- onlineFailure,7- offlineFailure,8- onlinePending,9- offlinePending,10- unknown,11- suspend,12- pending,13- isolated,14- unused. Generates critical alert if value is other than 1 or 2.[OIDs: 1.3.6.1.4.1.119.2.3.207.1.2.1.3.0,1.3.6.1.4.1.119.2.3.207.1.2.1.1.0]

NEC Server Performance and Status - G2

Description

It monitors hardware status parameters like Fan,Voltage,Temperature,CPU Board,CPU Cache Volume,CPU Physical,Driver and Volume. Also it monitors basic performance parameters like Memory and CPU utilization.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
NEC CPU Board Statusnec.cpu.board.statusCPU Board StatusThe current status of each CPU board. Possible values for this monitor (1- Other,2- Unknown,3- Normal,4- Warning,5- Fatal,6- Non-recoverable,7- In-test,8- Degraded,9- Disabled,10- Down,11- Standby). Generates warning alert if value in (1,2,4,7,9,11) and generates critical alert if value in (5,6,8,10).[OID: 1.3.6.1.4.1.119.2.2.4.4.2.2.3.2.1.5]
NEC CPU Cache Statusnec.cpu.cache.statusCPU Cache StatusThe current status of each CPU cache. Possible values for this monitor (1- Other,2- Unknown,3- Normal,4- Warning,5- Fatal,6- Non-recoverable,7- In-test,8- Degraded,9- Disabled,10- Down,11- Standby). Generates warning alert if value in (1,2,4,7,9,11) and generates critical alert if value in (5,6,8,10).[OID: 1.3.6.1.4.1.119.2.2.4.4.2.2.2.2.1.8]
NEC CPU Physical Statusnec.cpu.physical.statusCPU Physical StatusThe current status of each CPU. Possible values for this monitor (1- Other,2- Unknown,3- Normal,4- Warning,5- Fatal,6- Non-recoverable,7- In-test,8- Degraded,9- Disabled,10- Down,11- Standby).[OID: 1.3.6.1.4.1.119.2.2.4.4.2.2.4.2.1.7]
NEC CPU Utilizationnec.cpu.utilizationCPU Utilization%The individual CPU average load as a percentage during the last 5 minutes. Default warning threshold: 80%,Critical threshold: 90%.[OID:1.3.6.1.4.1.119.2.2.4.4.2.2.1.22.1.21]
NEC Driver Statusnec.driver.statusDriver StatusThe current status of the driver. Possible values for this monitor(1: Other,2: Unknown,3: Running,4: Suspended,5: Disabled,6: Stopped,7: Start-pending,8: Stop-pending,9: Suspend-pending,10: Continue-pending). Generates warning alert if value in (1,2,7,8,9,10) and generates critical alert if value in (4,5,6).[OIDs: 1.3.6.1.4.1.119.2.2.4.4.17.2.2.1.2,1.3.6.1.4.1.119.2.2.4.4.17.2.2.1.5]
NEC Fan Statusnec.fan.statusFan StatusThe current status of this fan. Possible values for this monitor (1: Other,2: Unknown,3: Normal,4: Warning,5: Fatal,6: Non-recoverable,7: In-test,8: Degraded,9: Disabled,10- Down). Generates warning alert if value in (1,2,4,7,9) and generates critical alert if value in (5,6,8,10).[OIDs: 1.3.6.1.4.1.119.2.2.4.4.10.2.3.2.1.2,1.3.6.1.4.1.119.2.2.4.4.10.2.3.2.1.3]
NEC Memory Utilizationnec.physical.mem.utilPhysical Memory Utilization%The total physical memory utilization in percentage. Total [OID: 1.3.6.1.4.1.119.2.2.4.4.4.2.1.1.0],Used [OID: 1.3.6.1.4.1.119.2.2.4.4.4.2.1.3.0].
nec.virtual.mem.utilVirtual Memory Utilization%The total virtual memory utilization in percentage. Total [OID: 1.3.6.1.4.1.119.2.2.4.4.4.2.2.1.0],Used [OID: 1.3.6.1.4.1.119.2.2.4.4.4.2.2.2.0].
NEC Overall CPU Utilizationnec.overall.cpu.utilOverall CPU Utilization%The overall CPU average load as a percentage during the last 5 minutes. Default warning threshold: 80%,Critical threshold: 90%.[OID: 1.3.6.1.4.1.119.2.2.4.4.2.2.1.9.0]
NEC Temperature Statusnec.temperature.statusTemperature StatusThe current status of the temperature monitored by this thermal sensor. Possible values for this monitor (1: Other,2: Unknown,3: Normal,4: Warning,5: Fatal,6: Non-recoverable,7: In-test,8: Degraded,9: Disabled,10- Down). Generates warning alert if value in (1,2,4,7,9) and generates critical alert if value in (5,6,8,10).[OIDs: 1.3.6.1.4.1.119.2.2.4.4.10.2.1.2.1.2,1.3.6.1.4.1.119.2.2.4.4.10.2.1.2.1.3,1.3.6.1.4.1.119.2.2.4.4.10.2.1.2.1.5]
nec.temperature.unitTemperature UnitThe temperature unit for the current temperature.
NEC Voltage Statusnec.voltage.statusVoltage StatusThe current status of the voltage monitored by the voltage sensor. Possible values for this monitor (1: Other,2: Unknown,3: Normal,4: Warning,5: Fatal,6: Non-recoverable,7: In-test,8: Degraded,9: Disabled,10- Down). Generates warning alert if value in (1,2,4,7,9) and generates critical alert if value in (5,6,8,10).[OIDs: 1.3.6.1.4.1.119.2.2.4.4.10.2.2.2.1.2,1.3.6.1.4.1.119.2.2.4.4.10.2.2.2.1.4,1.3.6.1.4.1.119.2.2.4.4.10.2.2.2.1.3]
nec.volume.statusVolume StatusState of volume. Possible values for this monitor (1: Other,2: Unknown,3: Normal,4: Warning,5: Fatal,6: Non-recoverable,7: In-test,8: Degraded,9: Disabled,10- Down). Generates warning alert if value in (1,2,4,7,9) and generates critical alert if value in (5,6,8,10).[OID: 1.3.6.1.4.1.119.2.2.4.4.29.2.3.1.2]

NEC PICOS Hardware

Description

Template to monitor the NEC PICOS Router hardware statistics like Fan Status,Fan Speed,PowerSupply Status,Temperature,Voltage and Mobile Device Signal Strength and Dail Status.[PICO-SMI :: picoFanStatus : 1.3.6.1.4.1.119.2.3.84.2.3.1.2,picoFanRpm : 1.3.6.1.4.1.119.2.3.84.2.3.1.3,picoPowerSupplyStatus : 1.3.6.1.4.1.119.2.3.84.2.4.1.3,picoCelsius : 1.3.6.1.4.1.119.2.3.84.2.1.1.0,picoVoltage : 1.3.6.1.4.1.119.2.3.84.2.2.0,picoMobileDeviceSignalStrength : 1.3.6.1.4.1.119.2.3.84.11.1.1.1.7,picoMobileDeviceDialStatus : 1.3.6.1.4.1.119.2.3.84.11.1.1.1.13]

Prerequisites

Device must have support for PICO-SMI mib

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
NEC PICO - Fannec_pico_FanStatusNEC PICO Fan StatusMonitors the Status of a fan module.[PICO-SMI :: picoFanStatus : 1.3.6.1.4.1.119.2.3.84.2.3.1.2] Possible values are : 1 : normal,2 : failure.
nec_pico_FanRpmNEC PICO Fan RpmrpmMonitors the NEC PICO device Fan Speed in Rpm.[PICO-SMI :: picoFanRpm : 1.3.6.1.4.1.119.2.3.84.2.3.1.3]
NEC PICO - PowerSupplynec_pico_PowerSupplyStatusNEC PICO Power Supply StatusMonitors the Status of a Power Supply module.[PICO-SMI :: picoPowerSupplyStatus : 1.3.6.1.4.1.119.2.3.84.2.4.1.3] Possible values are : 0 : notInstalled,1 : normal,2 : failure.
NEC PICO - Temperaturenec_pico_CelsiusNEC PICO Celsius TemperatureCelsiusMonitors the temperature of the equipment inside,in degree (Celsius).[PICO-SMI :: picoCelsius : 1.3.6.1.4.1.119.2.3.84.2.1.1.0]
NEC PICO - Voltagenec_pico_VoltageNEC PICO VoltagemVMonitors the observed voltage,in milli-volt (mV).[PICO-SMI :: picoVoltage : 1.3.6.1.4.1.119.2.3.84.2.2.0]
NEC PICO - Mobile Devicenec_pico_MobileDeviceSignalStrengthNEC PICO Mobile Device Signal StrengthMonitors the NEC PICO Mobile Device Signal Strength.[PICO-SMI :: picoMobileDeviceSignalStrength : 1.3.6.1.4.1.119.2.3.84.11.1.1.1.7] Possible values are : -1 : unknown,0 : out-range,1 : weak,2 : low,3 : high.
nec_PicoMobileDeviceDialStatusNEC PICO Mobile Device Dial StatusMonitors the NEC PICO Mobile Device Dial Status.[PICO-SMI :: picoMobileDeviceDialStatus : 1.3.6.1.4.1.119.2.3.84.11.1.1.1.13] Possible values are : 0 : disconnected,1 : connect,2 : cancel,3 : connected,4 : postprocess.

NEC PICOS Interface

Description

Template to monitor the NEC PICOS Router interface statistics like Interface Status,IPv4 UFS cache entries,peaks,creates and overflows and IPv6 UFS cache entries,peaks,creates and overflows.[PICO-SMI :: picoExtIfDescr : 1.3.6.1.4.1.119.2.3.84.6.1.1.3,picoExtIfAdminStatus : 1.3.6.1.4.1.119.2.3.84.6.1.1.10,picoExtIfOperStatus : 1.3.6.1.4.1.119.2.3.84.6.1.1.11,picoIPv4UFSCacheEntries : 1.3.6.1.4.1.119.2.3.84.12.2.1.0,picoIPv4UFSCachePeaks : 1.3.6.1.4.1.119.2.3.84.12.2.2.0,picoIPv4UFSCacheCreates : 1.3.6.1.4.1.119.2.3.84.12.2.3.0,picoIPv4UFSCacheOverflows : 1.3.6.1.4.1.119.2.3.84.12.2.4.0,picoIPv6UFSCacheEntries : 1.3.6.1.4.1.119.2.3.84.13.2.1.0,picoIPv6UFSCachePeaks : 1.3.6.1.4.1.119.2.3.84.13.2.2.0,picoIPv6UFSCacheCreates : 1.3.6.1.4.1.119.2.3.84.13.2.3.0,picoIPv6UFSCacheOverflows : 1.3.6.1.4.1.119.2.3.84.13.2.4.0].

Prerequisites

Device must have support for PICO-SMI mib

Supported Metric

>
Monitor NameMetric NameMetric Display NameUnitDescription
NEC PICO - Interface Statusnec_pico_InterfaceStatusNEC PICO Interface StatusMonitors the NEC PICO Device Interface Status.[PICO-SMI :: picoExtIfDescr : 1.3.6.1.4.1.119.2.3.84.6.1.1.3,picoExtIfAdminStatus : 1.3.6.1.4.1.119.2.3.84.6.1.1.10,picoExtIfOperStatus : 1.3.6.1.4.1.119.2.3.84.6.1.1.11] Possible values are : 0 : adminDown,1 : up,2 : down,3 : testing.
NEC PICO - IPv4 UFSnec_pico_IPv4UFSCacheEntriesNEC PICO IPv4 UFS Cache EntriescountMonitors the number of current IPv4 UFS cache.[PICO-SMI :: picoIPv4UFSCacheEntries : 1.3.6.1.4.1.119.2.3.84.12.2.1.0]
nec_pico_IPv4UFSCachePeaksNEC PICO IPv4 UFS Cache PeaksMonitors the peak value of IPv4 UFS cache.[PICO-SMI :: picoIPv4UFSCachePeaks : 1.3.6.1.4.1.119.2.3.84.12.2.2.0]
nec_pico_IPv4UFSCacheCreatesNEC PICO IPv4 UFS Cache CreatescountMonitors the total count of created IPv4 UFS cache.[PICO-SMI :: picoIPv4UFSCacheCreates : 1.3.6.1.4.1.119.2.3.84.12.2.3.0]
nec_pico_IPv4UFSCacheOverflowsNEC PICO IPv4 UFS Cache OverflowscountMonitors the total count of IPv4 UFS cache overflow.[PICO-SMI :: picoIPv4UFSCacheOverflows : 1.3.6.1.4.1.119.2.3.84.12.2.4.0]
NEC PICO - IPv6 UFSnec_pico_IPv6UFSCacheEntriesNEC PICO IPv6 UFS Cache EntriescountMonitors the number of current IPv6 UFS cache.[PICO-SMI :: picoIPv6UFSCacheEntries : 1.3.6.1.4.1.119.2.3.84.13.2.1.0]
nec_pico_IPv6UFSCachePeaksNEC PICO IPv6 UFS Cache PeaksMonitors the peak value of IPv6 UFS cache.[PICO-SMI :: picoIPv6UFSCachePeaks : 1.3.6.1.4.1.119.2.3.84.13.2.2.0]
nec_pico_IPv6UFSCacheCreatesNEC PICO IPv6 UFS Cache CreatescountMonitors the total count of created IPv6 UFS cache.[PICO-SMI :: picoIPv6UFSCacheCreates : 1.3.6.1.4.1.119.2.3.84.13.2.3.0]
nec_pico_IPv6UFSCacheOverflowsNEC PICO IPv6 UFS Cache OverflowscountMonitors the total count of IPv6 UFS cache overflow.[PICO-SMI :: picoIPv6UFSCacheOverflows : 1.3.6.1.4.1.119.2.3.84.13.2.4.0]

NEC PICOS Performance

Description

Template to monitor the NEC PICOS Router performance statistics like Memory utilization and CPU utilization.[PICO-SMI :: picoSchedRtUtl1Min : 1.3.6.1.4.1.119.2.3.84.2.5.3.0,picoHeapSize : 1.3.6.1.4.1.119.2.3.84.2.6.1.0,picoHeapUtil : 1.3.6.1.4.1.119.2.3.84.2.6.2.0]

Prerequisites

Device must have support for PICO-SMI mib

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
NEC PICO - Performancenec_pico_CpuUtil1minNEC PICO CPU Utilization 1Minute%Monitors the observed system utilization for last 1 minute,in percent (%).[PICO-SMI :: picoSchedRtUtl1Min : 1.3.6.1.4.1.119.2.3.84.2.5.3.0]
nec_pico_HeapMemUtilNEC PICO Heap Memory Utilization%Monitors the observed current heap memory utilization,in percent (%).[PICO-SMI :: picoHeapSize : 1.3.6.1.4.1.119.2.3.84.2.6.1.0,picoHeapUtil : 1.3.6.1.4.1.119.2.3.84.2.6.2.0]

NEC PICOS QOS

Description

Template to monitor the NEC PICOS Router QOS statistics like QOS Class Drop Packets and Bytes and QOS Queue Drop Packets and Bytes.[PICO-SMI :: qosClassDropPkts : 1.3.6.1.4.1.119.2.3.84.14.2.1.12,qosClassDropbytes : 1.3.6.1.4.1.119.2.3.84.14.2.1.13,qosQueueDropPkts : 1.3.6.1.4.1.119.2.3.84.14.3.1.8,qosQueueDropbytes : 1.3.6.1.4.1.119.2.3.84.14.3.1.9]

Prerequisites

Device must have support for PICO-SMI mib

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
NEC PICO - QOS Class Dropnec_pico_QosClassDropPktsNEC PICO QOS Class Drop Packetspackets/secMonitors the QoS Class Drop Packets.[PICO-SMI :: qosClassDropPkts : 1.3.6.1.4.1.119.2.3.84.14.2.1.12]
nec_pico_QosClassDropbytesNEC PICO QOS Class Drop BytesBpsMonitors the QoS Class Drop Bytes.[PICO-SMI :: qosClassDropbytes : 1.3.6.1.4.1.119.2.3.84.14.2.1.13]
NEC PICO - QOS Queue Dropnec_pico_QosQueueDropPktsNEC PICO QOS Queue Drop Packetspackets/secMonitors the QoS Queue Drop Packets.[PICO-SMI :: qosQueueDropPkts : 1.3.6.1.4.1.119.2.3.84.14.3.1.8]
nec_pico_QosQueueDropbytesNEC PICO QOS Queue Drop BytesBpsMonitors the QoS Queue Drop Bytes.[PICO-SMI :: qosQueueDropbytes : 1.3.6.1.4.1.119.2.3.84.14.3.1.9]