NEC - PDM Health
Description
Template to monitor NEC PDM(Projector and Display Management) Health parameters like Fan Status,Light Source Status,Temperature Sensor status,Temperature Sensor Value.
Prerequisites
Device should have support for PWG-PROJECTOR-DISPLAY-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
NEC - PDM Fan | nec.pdm.fan.status | PDM Fan Status | It monitors the PDM(Projector and Display Management) fan status. Possible values are 1: other,2: unknown,3: okay,4: warning,5: tooFastFail,6: tooSlowFail,7: slowStartWarning.[PWG-PROJECTOR-DISPLAY-MIB::pdmFanStatus:1.3.6.1.4.1.2699.1.4.1.8.1.1.3]. | |
NEC - PDM Light Source | nec.pdm.light.source.status | PDM Light Source Status | It monitors the PDM(Projector and Display Management) light source status. Possible values are 1: other,2: unknown,3: okay,4: failed.[PWG-PROJECTOR-DISPLAY-MIB::pdmLightSourceStatus:1.3.6.1.4.1.2699.1.4.1.7.1.1.3]. | |
NEC - PDM Temperature Sensor | nec.pdm.temp.sensor.status | PDM Temperature Sensor Status | It monitors the PDM(Projector and Display Management) temperature sensor status. Possible values are 1: other,2: unknown,3: okay,4: warning,5: hiTempLimitFail,6: lowTempLimitFail.[PWG-PROJECTOR-DISPLAY-MIB::pdmTempSensorStatus:1.3.6.1.4.1.2699.1.4.1.10.1.1.3]. | |
nec.pdm.temp.sensor.value | PDM Temperature Sensor Value | Celsius | It monitors the PDM(Projector and Display Management) temperature sensor value in degree Celsius.[PWG-PROJECTOR-DISPLAY-MIB::pdmTempSensorTemp:1.3.6.1.4.1.2699.1.4.1.10.1.1.4]. |
NEC Express Cluster Status - G2
Description
It monitors the each cluster server and current status of cluster.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
NEC Cluster Server Status | nec.cluster.server.status | Cluster Server Status | The current status of each cluster server. Possible values for this monitor are 1- normal,2- online,3- offline,4- caution,5- error,6- onlineFailure,7- offlineFailure,8- onlinePending,9- offlinePending,10- unknown,11- suspend,12- pending,13- isolated,14- unused. Generates critical alert if value is other than 1 or 2.[OIDs: 1.3.6.1.4.1.119.2.3.207.1.2.2.2.1.2,1.3.6.1.4.1.119.2.3.207.1.2.2.2.1.4] | |
NEC Cluster Status | nec.cluster.status | Cluster Status | The current status of cluster. Possible values for this monitor are 1- normal,2- online,3- offline,4- caution,5- error,6- onlineFailure,7- offlineFailure,8- onlinePending,9- offlinePending,10- unknown,11- suspend,12- pending,13- isolated,14- unused. Generates critical alert if value is other than 1 or 2.[OIDs: 1.3.6.1.4.1.119.2.3.207.1.2.1.3.0,1.3.6.1.4.1.119.2.3.207.1.2.1.1.0] |
NEC Server Performance and Status - G2
Description
It monitors hardware status parameters like Fan,Voltage,Temperature,CPU Board,CPU Cache Volume,CPU Physical,Driver and Volume. Also it monitors basic performance parameters like Memory and CPU utilization.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
NEC CPU Board Status | nec.cpu.board.status | CPU Board Status | The current status of each CPU board. Possible values for this monitor (1- Other,2- Unknown,3- Normal,4- Warning,5- Fatal,6- Non-recoverable,7- In-test,8- Degraded,9- Disabled,10- Down,11- Standby). Generates warning alert if value in (1,2,4,7,9,11) and generates critical alert if value in (5,6,8,10).[OID: 1.3.6.1.4.1.119.2.2.4.4.2.2.3.2.1.5] | |
NEC CPU Cache Status | nec.cpu.cache.status | CPU Cache Status | The current status of each CPU cache. Possible values for this monitor (1- Other,2- Unknown,3- Normal,4- Warning,5- Fatal,6- Non-recoverable,7- In-test,8- Degraded,9- Disabled,10- Down,11- Standby). Generates warning alert if value in (1,2,4,7,9,11) and generates critical alert if value in (5,6,8,10).[OID: 1.3.6.1.4.1.119.2.2.4.4.2.2.2.2.1.8] | |
NEC CPU Physical Status | nec.cpu.physical.status | CPU Physical Status | The current status of each CPU. Possible values for this monitor (1- Other,2- Unknown,3- Normal,4- Warning,5- Fatal,6- Non-recoverable,7- In-test,8- Degraded,9- Disabled,10- Down,11- Standby).[OID: 1.3.6.1.4.1.119.2.2.4.4.2.2.4.2.1.7] | |
NEC CPU Utilization | nec.cpu.utilization | CPU Utilization | % | The individual CPU average load as a percentage during the last 5 minutes. Default warning threshold: 80%,Critical threshold: 90%.[OID:1.3.6.1.4.1.119.2.2.4.4.2.2.1.22.1.21] |
NEC Driver Status | nec.driver.status | Driver Status | The current status of the driver. Possible values for this monitor(1: Other,2: Unknown,3: Running,4: Suspended,5: Disabled,6: Stopped,7: Start-pending,8: Stop-pending,9: Suspend-pending,10: Continue-pending). Generates warning alert if value in (1,2,7,8,9,10) and generates critical alert if value in (4,5,6).[OIDs: 1.3.6.1.4.1.119.2.2.4.4.17.2.2.1.2,1.3.6.1.4.1.119.2.2.4.4.17.2.2.1.5] | |
NEC Fan Status | nec.fan.status | Fan Status | The current status of this fan. Possible values for this monitor (1: Other,2: Unknown,3: Normal,4: Warning,5: Fatal,6: Non-recoverable,7: In-test,8: Degraded,9: Disabled,10- Down). Generates warning alert if value in (1,2,4,7,9) and generates critical alert if value in (5,6,8,10).[OIDs: 1.3.6.1.4.1.119.2.2.4.4.10.2.3.2.1.2,1.3.6.1.4.1.119.2.2.4.4.10.2.3.2.1.3] | |
NEC Memory Utilization | nec.physical.mem.util | Physical Memory Utilization | % | The total physical memory utilization in percentage. Total [OID: 1.3.6.1.4.1.119.2.2.4.4.4.2.1.1.0],Used [OID: 1.3.6.1.4.1.119.2.2.4.4.4.2.1.3.0]. |
nec.virtual.mem.util | Virtual Memory Utilization | % | The total virtual memory utilization in percentage. Total [OID: 1.3.6.1.4.1.119.2.2.4.4.4.2.2.1.0],Used [OID: 1.3.6.1.4.1.119.2.2.4.4.4.2.2.2.0]. | |
NEC Overall CPU Utilization | nec.overall.cpu.util | Overall CPU Utilization | % | The overall CPU average load as a percentage during the last 5 minutes. Default warning threshold: 80%,Critical threshold: 90%.[OID: 1.3.6.1.4.1.119.2.2.4.4.2.2.1.9.0] |
NEC Temperature Status | nec.temperature.status | Temperature Status | The current status of the temperature monitored by this thermal sensor. Possible values for this monitor (1: Other,2: Unknown,3: Normal,4: Warning,5: Fatal,6: Non-recoverable,7: In-test,8: Degraded,9: Disabled,10- Down). Generates warning alert if value in (1,2,4,7,9) and generates critical alert if value in (5,6,8,10).[OIDs: 1.3.6.1.4.1.119.2.2.4.4.10.2.1.2.1.2,1.3.6.1.4.1.119.2.2.4.4.10.2.1.2.1.3,1.3.6.1.4.1.119.2.2.4.4.10.2.1.2.1.5] | |
nec.temperature.unit | Temperature Unit | The temperature unit for the current temperature. | ||
NEC Voltage Status | nec.voltage.status | Voltage Status | The current status of the voltage monitored by the voltage sensor. Possible values for this monitor (1: Other,2: Unknown,3: Normal,4: Warning,5: Fatal,6: Non-recoverable,7: In-test,8: Degraded,9: Disabled,10- Down). Generates warning alert if value in (1,2,4,7,9) and generates critical alert if value in (5,6,8,10).[OIDs: 1.3.6.1.4.1.119.2.2.4.4.10.2.2.2.1.2,1.3.6.1.4.1.119.2.2.4.4.10.2.2.2.1.4,1.3.6.1.4.1.119.2.2.4.4.10.2.2.2.1.3] | |
nec.volume.status | Volume Status | State of volume. Possible values for this monitor (1: Other,2: Unknown,3: Normal,4: Warning,5: Fatal,6: Non-recoverable,7: In-test,8: Degraded,9: Disabled,10- Down). Generates warning alert if value in (1,2,4,7,9) and generates critical alert if value in (5,6,8,10).[OID: 1.3.6.1.4.1.119.2.2.4.4.29.2.3.1.2] |
NEC PICOS Hardware
Description
Template to monitor the NEC PICOS Router hardware statistics like Fan Status,Fan Speed,PowerSupply Status,Temperature,Voltage and Mobile Device Signal Strength and Dail Status.[PICO-SMI :: picoFanStatus : 1.3.6.1.4.1.119.2.3.84.2.3.1.2,picoFanRpm : 1.3.6.1.4.1.119.2.3.84.2.3.1.3,picoPowerSupplyStatus : 1.3.6.1.4.1.119.2.3.84.2.4.1.3,picoCelsius : 1.3.6.1.4.1.119.2.3.84.2.1.1.0,picoVoltage : 1.3.6.1.4.1.119.2.3.84.2.2.0,picoMobileDeviceSignalStrength : 1.3.6.1.4.1.119.2.3.84.11.1.1.1.7,picoMobileDeviceDialStatus : 1.3.6.1.4.1.119.2.3.84.11.1.1.1.13]
Prerequisites
Device must have support for PICO-SMI mib
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
NEC PICO - Fan | nec_pico_FanStatus | NEC PICO Fan Status | Monitors the Status of a fan module.[PICO-SMI :: picoFanStatus : 1.3.6.1.4.1.119.2.3.84.2.3.1.2] Possible values are : 1 : normal,2 : failure. | |
nec_pico_FanRpm | NEC PICO Fan Rpm | rpm | Monitors the NEC PICO device Fan Speed in Rpm.[PICO-SMI :: picoFanRpm : 1.3.6.1.4.1.119.2.3.84.2.3.1.3] | |
NEC PICO - PowerSupply | nec_pico_PowerSupplyStatus | NEC PICO Power Supply Status | Monitors the Status of a Power Supply module.[PICO-SMI :: picoPowerSupplyStatus : 1.3.6.1.4.1.119.2.3.84.2.4.1.3] Possible values are : 0 : notInstalled,1 : normal,2 : failure. | |
NEC PICO - Temperature | nec_pico_Celsius | NEC PICO Celsius Temperature | Celsius | Monitors the temperature of the equipment inside,in degree (Celsius).[PICO-SMI :: picoCelsius : 1.3.6.1.4.1.119.2.3.84.2.1.1.0] |
NEC PICO - Voltage | nec_pico_Voltage | NEC PICO Voltage | mV | Monitors the observed voltage,in milli-volt (mV).[PICO-SMI :: picoVoltage : 1.3.6.1.4.1.119.2.3.84.2.2.0] |
NEC PICO - Mobile Device | nec_pico_MobileDeviceSignalStrength | NEC PICO Mobile Device Signal Strength | Monitors the NEC PICO Mobile Device Signal Strength.[PICO-SMI :: picoMobileDeviceSignalStrength : 1.3.6.1.4.1.119.2.3.84.11.1.1.1.7] Possible values are : -1 : unknown,0 : out-range,1 : weak,2 : low,3 : high. | |
nec_PicoMobileDeviceDialStatus | NEC PICO Mobile Device Dial Status | Monitors the NEC PICO Mobile Device Dial Status.[PICO-SMI :: picoMobileDeviceDialStatus : 1.3.6.1.4.1.119.2.3.84.11.1.1.1.13] Possible values are : 0 : disconnected,1 : connect,2 : cancel,3 : connected,4 : postprocess. |
NEC PICOS Interface
Description
Template to monitor the NEC PICOS Router interface statistics like Interface Status,IPv4 UFS cache entries,peaks,creates and overflows and IPv6 UFS cache entries,peaks,creates and overflows.[PICO-SMI :: picoExtIfDescr : 1.3.6.1.4.1.119.2.3.84.6.1.1.3,picoExtIfAdminStatus : 1.3.6.1.4.1.119.2.3.84.6.1.1.10,picoExtIfOperStatus : 1.3.6.1.4.1.119.2.3.84.6.1.1.11,picoIPv4UFSCacheEntries : 1.3.6.1.4.1.119.2.3.84.12.2.1.0,picoIPv4UFSCachePeaks : 1.3.6.1.4.1.119.2.3.84.12.2.2.0,picoIPv4UFSCacheCreates : 1.3.6.1.4.1.119.2.3.84.12.2.3.0,picoIPv4UFSCacheOverflows : 1.3.6.1.4.1.119.2.3.84.12.2.4.0,picoIPv6UFSCacheEntries : 1.3.6.1.4.1.119.2.3.84.13.2.1.0,picoIPv6UFSCachePeaks : 1.3.6.1.4.1.119.2.3.84.13.2.2.0,picoIPv6UFSCacheCreates : 1.3.6.1.4.1.119.2.3.84.13.2.3.0,picoIPv6UFSCacheOverflows : 1.3.6.1.4.1.119.2.3.84.13.2.4.0].
Prerequisites
Device must have support for PICO-SMI mib
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
NEC PICO - Interface Status | nec_pico_InterfaceStatus | NEC PICO Interface Status | Monitors the NEC PICO Device Interface Status.[PICO-SMI :: picoExtIfDescr : 1.3.6.1.4.1.119.2.3.84.6.1.1.3,picoExtIfAdminStatus : 1.3.6.1.4.1.119.2.3.84.6.1.1.10,picoExtIfOperStatus : 1.3.6.1.4.1.119.2.3.84.6.1.1.11] Possible values are : 0 : adminDown,1 : up,2 : down,3 : testing. | |
NEC PICO - IPv4 UFS | nec_pico_IPv4UFSCacheEntries | NEC PICO IPv4 UFS Cache Entries | count | Monitors the number of current IPv4 UFS cache.[PICO-SMI :: picoIPv4UFSCacheEntries : 1.3.6.1.4.1.119.2.3.84.12.2.1.0] |
nec_pico_IPv4UFSCachePeaks | NEC PICO IPv4 UFS Cache Peaks | Monitors the peak value of IPv4 UFS cache.[PICO-SMI :: picoIPv4UFSCachePeaks : 1.3.6.1.4.1.119.2.3.84.12.2.2.0] | ||
nec_pico_IPv4UFSCacheCreates | NEC PICO IPv4 UFS Cache Creates | count | Monitors the total count of created IPv4 UFS cache.[PICO-SMI :: picoIPv4UFSCacheCreates : 1.3.6.1.4.1.119.2.3.84.12.2.3.0] | |
nec_pico_IPv4UFSCacheOverflows | NEC PICO IPv4 UFS Cache Overflows | count | Monitors the total count of IPv4 UFS cache overflow.[PICO-SMI :: picoIPv4UFSCacheOverflows : 1.3.6.1.4.1.119.2.3.84.12.2.4.0] | |
NEC PICO - IPv6 UFS | >nec_pico_IPv6UFSCacheEntries | NEC PICO IPv6 UFS Cache Entries | count | Monitors the number of current IPv6 UFS cache.[PICO-SMI :: picoIPv6UFSCacheEntries : 1.3.6.1.4.1.119.2.3.84.13.2.1.0] |
nec_pico_IPv6UFSCachePeaks | NEC PICO IPv6 UFS Cache Peaks | Monitors the peak value of IPv6 UFS cache.[PICO-SMI :: picoIPv6UFSCachePeaks : 1.3.6.1.4.1.119.2.3.84.13.2.2.0] | ||
nec_pico_IPv6UFSCacheCreates | NEC PICO IPv6 UFS Cache Creates | count | Monitors the total count of created IPv6 UFS cache.[PICO-SMI :: picoIPv6UFSCacheCreates : 1.3.6.1.4.1.119.2.3.84.13.2.3.0] | |
nec_pico_IPv6UFSCacheOverflows | NEC PICO IPv6 UFS Cache Overflows | count | Monitors the total count of IPv6 UFS cache overflow.[PICO-SMI :: picoIPv6UFSCacheOverflows : 1.3.6.1.4.1.119.2.3.84.13.2.4.0] |
NEC PICOS Performance
Description
Template to monitor the NEC PICOS Router performance statistics like Memory utilization and CPU utilization.[PICO-SMI :: picoSchedRtUtl1Min : 1.3.6.1.4.1.119.2.3.84.2.5.3.0,picoHeapSize : 1.3.6.1.4.1.119.2.3.84.2.6.1.0,picoHeapUtil : 1.3.6.1.4.1.119.2.3.84.2.6.2.0]
Prerequisites
Device must have support for PICO-SMI mib
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
NEC PICO - Performance | nec_pico_CpuUtil1min | NEC PICO CPU Utilization 1Minute | % | Monitors the observed system utilization for last 1 minute,in percent (%).[PICO-SMI :: picoSchedRtUtl1Min : 1.3.6.1.4.1.119.2.3.84.2.5.3.0] |
nec_pico_HeapMemUtil | NEC PICO Heap Memory Utilization | % | Monitors the observed current heap memory utilization,in percent (%).[PICO-SMI :: picoHeapSize : 1.3.6.1.4.1.119.2.3.84.2.6.1.0,picoHeapUtil : 1.3.6.1.4.1.119.2.3.84.2.6.2.0] |
NEC PICOS QOS
Description
Template to monitor the NEC PICOS Router QOS statistics like QOS Class Drop Packets and Bytes and QOS Queue Drop Packets and Bytes.[PICO-SMI :: qosClassDropPkts : 1.3.6.1.4.1.119.2.3.84.14.2.1.12,qosClassDropbytes : 1.3.6.1.4.1.119.2.3.84.14.2.1.13,qosQueueDropPkts : 1.3.6.1.4.1.119.2.3.84.14.3.1.8,qosQueueDropbytes : 1.3.6.1.4.1.119.2.3.84.14.3.1.9]
Prerequisites
Device must have support for PICO-SMI mib
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
NEC PICO - QOS Class Drop | nec_pico_QosClassDropPkts | NEC PICO QOS Class Drop Packets | packets/sec | Monitors the QoS Class Drop Packets.[PICO-SMI :: qosClassDropPkts : 1.3.6.1.4.1.119.2.3.84.14.2.1.12] |
nec_pico_QosClassDropbytes | NEC PICO QOS Class Drop Bytes | Bps | Monitors the QoS Class Drop Bytes.[PICO-SMI :: qosClassDropbytes : 1.3.6.1.4.1.119.2.3.84.14.2.1.13] | |
NEC PICO - QOS Queue Drop | nec_pico_QosQueueDropPkts | NEC PICO QOS Queue Drop Packets | packets/sec | Monitors the QoS Queue Drop Packets.[PICO-SMI :: qosQueueDropPkts : 1.3.6.1.4.1.119.2.3.84.14.3.1.8] |
nec_pico_QosQueueDropbytes | NEC PICO QOS Queue Drop Bytes | Bps | Monitors the QoS Queue Drop Bytes.[PICO-SMI :: qosQueueDropbytes : 1.3.6.1.4.1.119.2.3.84.14.3.1.9] |