HPE - HTTP Management Device Health

Description

Template to monitor HP HTTP Management Device Health.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP - HTTP Management Device Healthhp.http.mgmt.device.healthHTTP Management Device HealthIt monitors the overall health of the device.Possible values are unknown(1),unused(2),ok(3),warning(4),critical(5),nonrecoverable(6) [SEMI-MIB::hpHttpMgDeviceHealth:1.3.6.1.4.1.11.2.36.1.1.5.1.1.3].

HPE Blade System Switch monitors

Description

This template is applicable on HP switches meant for blade system. For eg GbE2c Ethernet Blade switch. Monitors CPU Utilization and VLAN status.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP Blade System Switch CPU Utilizationsystem.cpu.utilizationHP Blade System Switch CPU Utilization%Monitors the utilization (in percent) of MP CPU over 64 seconds.[OID: 1.3.6.1.4.1.11.2.3.7.11.33.4.2.1.2.2.3.0]
HP Blade System Switch VLAN Statusvlan.statusVLAN StatusMonitors the VLAN status information. Possible values are 2- Enabled,3- Disabled.[OIDs: 1.3.6.1.4.1.11.2.3.7.11.33.4.2.2.3.8.1.1.2,1.3.6.1.4.1.11.2.3.7.11.33.4.2.2.3.8.1.1.3]
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

HPE Compaq - Host Performance

Description

Template to monitor HPE Compaq Host Performance parameters like cpu utilization,file system space total,file system space used,file system status,physical memory size,physical memory free,physical memory utilization.[CPQHOST-MIB :: cpqHoCpuUtilFiveMin : 1.3.6.1.4.1.232.11.2.3.1.1.3,cpqHoFileSysSpaceTotal : 1.3.6.1.4.1.232.11.2.4.1.1.3,cpqHoFileSysSpaceUsed : 1.3.6.1.4.1.232.11.2.4.1.1.4,cpqHoFileSysStatus : 1.3.6.1.4.1.232.11.2.4.1.1.8,cpqHoPhysicalMemorySize : 1.3.6.1.4.1.232.11.2.13.1.0,cpqHoPhysicalMemoryFree : 1.3.6.1.4.1.232.11.2.13.2.0]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Compaq Cpq Host - Cpu Utilizationcompaq_cpqhost_CpqHoCpuUtilFiveMinCompaq Cpq Host Cpu Utilization%Monitors the Compaq cpq Host cpu utilization.[CPQHOST-MIB :: cpqHoCpuUtilFiveMin : 1.3.6.1.4.1.232.11.2.3.1.1.3]
Compaq Cpq Host - File Systemcompaq_cpqhost_CpqHoFileSysSpaceUtilizationCompaq Cpq Host File Sys Space Utilization%Monitors the Compaq Cpq Host File Sys Space Utilization.
compaq_cpqhost_CpqHoFileSysStatusCompaq Cpq Host File Sys StatusMonitors the threshold status.[CPQHOST-MIB :: cpqHoFileSysStatus : 1.3.6.1.4.1.232.11.2.4.1.1.8]
compaq_cpqhost_CpqHoFileSysSpaceTotalCompaq Cpq Host File Sys Space TotalMBMonitors the file system size in megabytes.[CPQHOST-MIB :: cpqHoFileSysSpaceTotal : 1.3.6.1.4.1.232.11.2.4.1.1.3]
compaq_cpqhost_CpqHoFileSysSpaceUsedCompaq Cpq Host File Sys Space UsedMBMonitors the compaq cpq host file sys space used.[CPQHOST-MIB :: cpqHoFileSysSpaceUsed : 1.3.6.1.4.1.232.11.2.4.1.1.4]
compaq_cpqhost_CpqHoPhysicalMemoryUtilizationCompaq Cpq Host Physical Memory Utilization%Monitors the Compaq Cpq Host Physical Memory Utilization
compaq_cpqhost_CpqHoPhysicalMemoryFreeCompaq Cpq Host Physical Memory FreeMBMonitors the Compaq Cpq Host Physical Memory Free in megabytes.[CPQHOST-MIB :: cpqHoPhysicalMemoryFree :: 1.3.6.1.4.1.232.11.2.13.2.0]
compaq_cpqhost_CpqHoPhysicalMemorySizeCompaq Cpq Host Physical Memory SizeMBMonitors the file system size in megabytes.[CPQHOST-MIB :: cpqHoPhysicalMemorySize : 1.3.6.1.4.1.232.11.2.13.1.0]

HPE Comware

Description

Template for HP Comware switch/router. Monitors entity CPU usage,memory usage,temperature,uptime,error status and alarm status. Validated on HP Comware Platform Software,Software Version 5.20.99 Release 2222P08 HP A5500-24G EI Switch with 2 Interface Slots. SNMP SysObjId=1.3.6.1.4.1.25506.11.1.24.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP Comware Entity Alarm Lighthp.comware.entity.alarm.lightHP Comware Entity Alarm LightProvides the Alarm status of this entity,It does not include the severity of alarms raised on child components. In this condition,there will be a alarm light on the entity,the object should have the same status with it.[OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.5]
HP Comware Entity CPU Usage - Rule Basedhp.comware.entity.cpu.usageHP Comware Entity CPU Usage%Provides the HP Comware CPU usage. Generally,the CPU usage will calculate the overall CPU usage on the entity,and it is not sensible with the number of CPU on the entity.[OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.6]
HP Comware Entity Error Statushp.comware.entity.error.statusHP Comware Entity Error StatusIt Indicate the error state of this entity object.[OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.19]
HP Comware Entity Temperature - Rule Basedhp.comware.entity.temperatureHP Comware Entity TemperatureCProvides the HP Comware temperature details for this Entity.[OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.12]
HP Comware Memory Usage - Rule Basedhp.comware.entity.memoryusageHP Comware Entity Memory Usage%Provides the details about the memory usage if this Entity,provides the usage vlues in percentage (%).[OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.8]
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

HPE iLO Monitors

Description

Template for HP ILO (Integrated Lights - Out). Monitors the battery,fan,temperature,fault tolerance power supply status. Also monitor controller battery status,controller interface status,etc,. Tested on HP ILO 4 AOS server.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
CPQ DA Acceleratorhp.ilo.cpq.da.accelerator.error.codeCPQ DA Accelerator Error CodeMonitors the drive array accelerator board error code. Used to determine the status of the write cache operations. The status can be: 1- Other: Indicates that the instrument agent does not recognize the error code. You may need to update your software,2-Invalid: Indicates that write cache operations are currently configured and enabled for at least one logical drive. No write cache errors have occurred,3- Bad Configuration: Indicates that write cache operations are temporarily disabled. The Array Accelerator board was configured for a different controller. This error could be caused if boards were switched from one system to another. Rerun the configuration utility and ensure that the board has been properly configured for this system. Note: If data from another system was stored on the board,running configuration utility will cause the data to be lost,4- Low Battery Power: Indicates that write cache operations are temporarily disabled due to insufficient battery power. Please view the Battery Status object instance for more information,5- Disable Command Issued: Indicates that write cache operations are temporarily disabled. The device driver issues this command when the server is taken down. This condition should not exist when the system regains power,6- No Resources Available: Indicates that write cache operations are temporarily disabled. The controller does not have sufficient resources to perform write cache operations. For example,when a replaced drive is being rebuilt,there will not be sufficient resources. Once the operation that requires the resources has completed,this condition will clear and write cache operations will resume,7- Board Not Connected: Indicates that write cache operations are temporarily disabled. The Array Accelerator board has been configured but is not currently attached to the controller. Check the alignment of the board and connections,8- Bad Mirror Data: Indicates that write cache operations have been permanently disabled. The Array Accelerator board stores mirrored copies of all data. If data exists on the board when the system is first powered up,the board performs a data compare test between the mirrored copies. If the data does not match,an error has occurred. Data may have been lost. Your board may need servicing,9- Read Failure: Indicates that write cache operations have been permanently disabled. The Array Accelerator board stores mirror copies of all data. While reading the data from the board,memory parity errors have occurred. Both copies were corrupted and cannot be retrieved. Data has been lost,and you should service the board,10- Write Failure: Indicates that write cache operations have been permanently disabled. This error occurs when an unsuccessful attempt was made to write data to the Array Accelerator board. Data could not be written to write cache memory in duplicate due to the detection of parity errors. This error does not indicate data loss. You should service the Array Accelerator board,11- Config Command: Indicates that write cache operations have been permanently disabled. The configuration of the logical drives has changed. You need to reconfigure the Array Accelerator board,12- Expand in Progress: Indicates that cache operations are temporarily disabled due to an expand of a logical drive. When the expand operation completes,the accelerator will be enabled,13- Snapshot In Progress: Indicates that cache operations are temporarily disabled due to a snapshot operation that is queued up or in progress. When the snapshot operation completes,the accelerator will be enabled,14- Redundant Low Battery: Indicates that cache operations are temporarily disabled. The redundant controller has insufficient cache battery power,15- Redundant Size Mismatch: Indicates that cache operations are temporarily disabled. The cache sizes on the redundant controllers do not match,16- Redundant Cache Failure: Indicates that cache operations are temporarily disabled. The cache on the redundant controller has failed,17- Excessive ECC Errors: Indicates that write cache operations have been permanently disabled. The number of cache lines experiencing excessive ECC errors has reached a preset limit,18- RAID ADG Enabler Module Missing: Indicates that write cache operations have been temperarily disabled. A RAID ADG logical drive is configured but the RAID ADG Enabler Module is broken or missing,19- Power On Self Test (Post) ECC Errors: Indicates that write cache operations have been permanently disabled. The cache has been disabled due to a large number of ECC errors detected while testing the cache during Power On Self Test (Post),20- Battery Hot Removed: Indicates that write cache operations have been permanently disabled. The cache has been disabled because a battery has been hot removed.[OIDs: 1.3.6.1.4.1.232.3.2.2.2.1.1,1.3.6.1.4.1.232.3.2.2.2.1.5]
hp.ilo.cpq.da.accelerator.batteryCPQ DA Accelerator Battery StatusMonitors the array accelerator board battery status. Provides the status of each battery pack on the board. The batteries can only recharge when the system has power applied. Possible values are 1- Other:Indicates that the instrument agent does not recognize battery status. You may need to update your software,2- Ok: Indicates that a particular battery pack is fully charged,3- Charging: The battery power is less than 75%. The Drive Array Controller is attempting to recharge the battery. A battery can take as long as 36 hours to fully recharge.After 36 hours,if the battery has not recharged,it is considered failed,4- Failed: The battery pack is below the sufficient voltage level and has not recharged in 36 hours. Your Array Accelerator board needs to be serviced,5- Degraded:The battery is still operating,however,one of the batteries in the pack has failed to recharge properly. Your Array Accelerator board should be serviced as soon as possible,6- NotPresent: There are no batteries associated with this controller.[OIDs: 1.3.6.1.4.1.232.3.2.2.2.1.1,1.3.6.1.4.1.232.3.2.2.2.1.6]
hp.ilo.cpq.da.accelerator.conditionCPQ DA Accelerator Overall ConditionMonitors the overall condition of drive array accelerator. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.2.2.1.1,1.3.6.1.4.1.232.3.2.2.2.1.9]
CPQ DA Array Controller Statusarraycontroller.statusCPQ DA Array Controller ConditionMonitors the overall condition of this controller,and any associated logical drives,physical drives,and array accelerators. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.2.1.1.1,1.3.6.1.4.1.232.3.2.2.1.1.6]
CPQ DA Conditionhp.ilo.cpq.da.conditionCPQ Drive Array Overall StatusMonitors the overall condition (status) of the driver array. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.3.1.3.0]
CPQ DA Logical Drivelogical.disk.statusCPQ DA Logical Drive ConditionMonitors the overall condition of this logical drive and any associated physical drives. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.3.1.1.1,1.3.6.1.4.1.232.3.2.3.1.1.2,1.3.6.1.4.1.232.3.2.3.1.1.11]
CPQ DA Physical Drivecpq.da.physical.drive.conditionCPQ DA Physical Drive ConditionMonitors the overall condition of this physical drive. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.5.1.1.1,1.3.6.1.4.1.232.3.2.5.1.1.2,1.3.6.1.4.1.232.3.2.5.1.1.37]
cpq.da.physical.drive.smartstatusCPQ DA Physical Drive SMART StatusMonitors the physical drive S.M.A.R.T status. Possible values are 1- other: The agent is unable to determine if the status of S.M.A.R.T predictive failure monitoring for this drive,2- ok: Indicates the drive is functioning properly,3- replaceDrive: Indicates that the drive has a S.M.A.R.T predictive failure error and should be replaced.[OIDs: 1.3.6.1.4.1.232.3.2.5.1.1.1,1.3.6.1.4.1.232.3.2.5.1.1.2,1.3.6.1.4.1.232.3.2.5.1.1.57]
CPQ HE Environmentcpu.fan.thermal.healthCPQ CPU Fan Thermal HealthProvides the status of the processor fan(s) in the system. This value will be one of the following:- other(1): Fan status detection is not supported by this system or driver,ok(2): All fans are operating properly,failed(4): A fan is not operating properly. System will be shutdown if the failed(4) condition occurs.[OID: 1.3.6.1.4.1.232.6.2.6.5.0]
temperature.sensors.healthCPQ System Temperature Sensors StatusProvides the status of the system's temperature sensors. This value will be one of the following:- other(1): Temp sensing is not supported by this system or driver,ok(2): All temp sensors are within normal operating range,degraded(3): A temp sensor is outside of normal operating range,failed(4): A temp sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results.[OIDs: 1.3.6.1.4.1.232.6.2.6.3.0]
system.fans.healthCPQ System Fans StatusThe status of the fan(s) in the system. This value will be one of the following:- other(1): Fan status detection is not supported by this system or driver,ok(2): All fans are operating properly,degraded(3): A non-required fan is not operating properly,failed(4): A required fan is not operating properly.[OID: 1.3.6.1.4.1.232.6.2.6.4.0]
over.server.thermal.healthCPQ Thermal Environment Overall HealthSpecifies the overall condition of the system's thermal environment.[OID: 1.3.6.1.4.1.232.6.2.6.1.0]
hp.ilo.cpq.he.conditionCPQ Server Health System Overall StatusMonitors the overall status of the server health system. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.1.3.0]
hp.ilo.cpq.he.asr.conditionCPQ Server Health ASR Overall ConditionMonitors the overall condition of the Automatic Server Recovery (ASR) feature. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.5.17.0]
hp.ilo.cpq.he.eventlog.conditionCPQ HE Event Log ConditionMonitors the overall condition of the integrated management log feature. Possible values are 1- Other,2- OK,3- degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.11.2.0]
hp.ilo.cpq.he.resillent.memory.conditionCPQ HE Resilient Memory ConditionMonitors the current condition of the Advanced Memory Protection subsystem. Possible values are 1- other: The system does not support fault tolerant memory or the state cannot be determined by the Management Agent,2- ok: This system is operating normally,3- degraded: The system is running in a degraded state because the Advanced Memory Protection subsystem has been engaged.[OID: 1.3.6.1.4.1.232.6.2.14.4.0]
cpq.ss.conditionCPQ Storage System Overall ConditionMonitors the overall condition (status) of the storage system. Possible values are 1- Other,2- OK,3- Degraded.[OID: 1.3.6.1.4.1.232.8.1.3.0]
cpq.he.fault.tolerant.powersupply.conditionCPQ HE Fault Tolerant Power Supply ConditionMonitors the overall condition of the fault tolerant power supply sub-system. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.9.1.0]
CPQ HE Fault Tolerant Fan Healthfault.tolerant.fan.statusCPQ HE Fault Tolerent Fan HealthProvides the condition of the fan. Possible values are 1- other: Fan status detection is not supported by this system or driver,2- ok: The fan is operating properly,3- degraded: A redundant fan is not operating properly,4- failed: A non-redundant fan is not operating properly.[OIDs: 1.3.6.1.4.1.232.6.2.6.7.1.1,1.3.6.1.4.1.232.6.2.6.7.1.2,1.3.6.1.4.1.232.6.2.6.7.1.9]
CPQ HE Power Supply Healthfault.tolerant.power.supply.statusCPQ Fault Tolerant Power Supply HealthMonitors the condition of the power supply. Possible values are 1- other: The status could not be determined or not present,2- ok: The power supply is operating normally,3- degraded: Power supply is outside of normal operating range,4- failed: power supply component detects a condition that could permanently damage the system.[OIDs: 1.3.6.1.4.1.232.6.2.9.3.1.4,1.3.6.1.4.1.232.6.2.9.3.1.1,1.3.6.1.4.1.232.6.2.9.3.1.2]
CPQ HE Resilient Memory 2 Board Conditionhp.ilo.cpq.he.resillentmemory.board.conditionCPQ HE Resilient Memory 2 Board ConditionMonitors the current status of the Advanced Memory Protection memory board or cartridge or riser. Possible values are 1- other: The condition of this memory board or cartridge or riser could not be determined,2- ok: The memory board or cartridge or riser is operating normally,3- degraded: The memory board or cartridge or riser is in an error state. Check for correct memory installation and that the board has been inserted properly.[OIDs: 1.3.6.1.4.1.232.6.2.14.12.1.1,1.3.6.1.4.1.232.6.2.14.12.1.11]
CPQ HE Resilient Memory 2 Module Conditioncpq.he.resilient.memory.2.module.conditionCPQ HE Resilient Memory 2 Module ConditionMonitors the current status of the correctable memory errors for this memory module. Possible values are 1- other: ECC is not supported on this memory module or the condition could not be determined,2- ok: The memory module is operating normally,3- degraded: The memory module is correctable error count has exceeded threshold or a configuration error has been detected,4- degradedModuleIndexUnknown: The correctable error count has exceeded threshold. The module number not available.[OIDs: 1.3.6.1.4.1.232.6.2.14.13.1.1,1.3.6.1.4.1.232.6.2.14.13.1.20]
CPQ HE Temperature Sensor Healthtemperature.sensor.statusCPQ Temperature Sensor HealthMonitors the temperature sensor condition. Possible values are 1- other: Temperature could not be determined,2- ok: The temperature sensor is within normal operating range,3- degraded: The temperature sensor is outside of normal operating range,4- failed: The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results.[OIDs: 1.3.6.1.4.1.232.6.2.6.8.1.6,1.3.6.1.4.1.232.6.2.6.8.1.1,1.3.6.1.4.1.232.6.2.6.8.1.2]
CPQ Host CPU Utilizationcpu.usageCPQ Host CPU Utilization%Monitors the The CPU utilization as a percentage of the theoretical maximum during the last five minutes. A value of -1 indicates that no CPU utilization information is available for this processor.[OID: 1.3.6.1.4.1.232.11.2.3.1.1.3,1.3.6.1.4.1.232.11.2.3.1.1.1]
CPQ SE CPU Cache Statuscpq.se.cpu.cache.statusCPQ CPU Cache StatusMonitors the status of the cache unit. If the cache is optional and not installed,unknown(1) will be returned.[OIDs: 1.3.6.1.4.1.232.1.2.2.3.1.1,1.3.6.1.4.1.232.1.2.2.3.1.2,1.3.6.1.4.1.232.1.2.2.3.1.5]
CPQ SE CPU Statuscpu.healthCPQ CPU StatusThe status of the processor. Possible values are 1- Unknown: The status of the CPU could not be determined,2- OK: The CPU is functioning normally,3- Degraded: The CPU is in a pre-failure warrantee state,4- Failed: The CPU is in a failed state,5- Disabled: The CPU has been disabled during power-on-self-test.[OIDs: 1.3.6.1.4.1.232.1.2.2.1.1.3,1.3.6.1.4.1.232.1.2.2.1.1.6]
CPQ SE Overall Conditioncpq.he.se.conditionCPQ Server Overall ConditionMonitors the overall condition of the server. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.1.1.3.0]
CPQ SI Conditioncpq.si.conditionCPQ Server Information Overall ConditionMonitors the overall status of the CPQ server information. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.2.1.3.0]
CPQ SM2 ILOcpq.sm2.conditionCPQ SM2 ConditionMonitors the overall condition of the Remote Insight/ Integrated Lights-Out. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.9.1.3.0]
cpq.sm2.controller.battery.statusCPQ SM2 Controller Battery StatusMonitors the remote insight battery status. Possible values are 1- other: The Insight Agent is unable to determine if the battery needs replacement,2- batteryOk: The Remote Insight battery is OK,3- batteryFailed: The Remote Insight battery needs replacement,4- batteryDisconnected: The Remote Insight battery is disconnected.[OID: 1.3.6.1.4.1.232.9.2.2.5.0]
cpq.sm2.controller.interface.statusCPQ SM2 Controller Interface StatusMonitors the Remote Insight/ Integrated Lights-Out Interface Status. Possible values are 1- other: The Insight Agent is unable to determine the status of the Remote Insight/ Integrated Lights-Out interface,2- ok: The Remote Insight/ Integrated Lights-Out firmware is responding to commands,3- notResponding: The Remote Insight/ Integrated Lights-Out firmware is not responding to commands.[OID: 1.3.6.1.4.1.232.9.2.2.17.0]
CPQ SM2 NIC Conditioncpq.sm2.nic.conditionCPQ SM2 NIC ConditionMonitors the overall condition of the Remote Insight/ Integrated Lights-Out Network Interface Controller (NIC). Possible values are are 1- Other,2- OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.9.2.5.1.1.11,1.3.6.1.4.1.232.9.2.5.1.1.5]
CPQ SS Boxcpq.ss.box.fan.statusCPQ SS Box Fan StatusMonitors the current status of the fans in the drive box. Possible values are 1- other: Fan monitoring is not supported by this system or it is not supported by the driver,2- ok: All fans are working normally,3- failed: One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage,4- noFan: This unit does not support fan monitoring,5- degraded: At least one storage system fan has failed,but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced.[OIDs: 1.3.6.1.4.1.232.8.2.1.1.1,1.3.6.1.4.1.232.8.2.1.1.2,1.3.6.1.4.1.232.8.2.1.1.7]
cpq.ss.box.conditionCPQ SS Box ConditionMonitors the overall condition of the drive box. Possible values are 1- other: The agent does not recognize the status. You may need to upgrade your software,2- ok: The storage system is operating normally. No user action is required,3- degraded: The storage system is degraded. You need to check the temperature status or power supply status of this storage system. Additionally,if the side panel for the storage system is removed,the air flow changes could result in improper cooling of the drives and affect the temperature status,4- failed: The storage system has failed.[OIDs: 1.3.6.1.4.1.232.8.2.1.1.2,1.3.6.1.4.1.232.8.2.1.1.8]
cpq.ss.box.temperature.statusCPQ SS Box Temperature StatusMonitors the temperature status of the drive system. Possible values are 1- other:Temperature monitoring is not supported by this systemor it is not supported by the driver,2- ok:The temperature is within normal operating range,3- degraded:The temperature is outside of normal operating range,4- failed:The temperature could permanently damage the system.The storage system will automatically shutdown if thiscondition is detected,5- noTemp:This unit does not support temperature monitoring.[OIDs: 1.3.6.1.4.1.232.8.2.1.1.2,1.3.6.1.4.1.232.8.2.1.1.9]
cpq.ss.box.fault.tolerance.power.supplyCPQ SS Box Fault Tolerant Power Supply StatusMonitors the overall status of the fault tolerant power supply sub-system in a drive box. Possible values are 1- other: The power supply status cannot be determined,2- ok: There are no detected power supply failures,3- degraded: One of the power supply units in a fault tolerant power supply has failed,4- failed: No failure conditions can currently be determined,5- noFltTolPower: This unit does not support fault tolerant power supply monitoring.[OIDs: 1.3.6.1.4.1.232.8.2.1.1.2,1.3.6.1.4.1.232.8.2.1.1.11]

HPE iLO Monitors - v2

Description

Template to monitor HPE hardware components through iLO (Integrated Lights - Out). Monitors the battery,fan,temperature,fault tolerance power supply status. Also monitor controller battery status,controller interface status,Drive array condition,Network Interface Card Status etc,. Tested on HPE Integrated Lights-Out 6 (iLO6) ProLiant DL380 Gen11. This template will works for both higher and lower versions of iLO6 but all the metrics may or may not work for all iLO versions as functionality differs between different iLO versions.

Prerequisites

Device must have support for CPQHLTH-MIB,CPQSM2-MIB,CPQSINFO-MIB,CPQSTDEQ-MIB,CPQIDA-MIB and CPQNIC-MIB.

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HPE iLO CPQ DA Array Controller Statushpe_ilo_drivearray_ControllerBoardConditionHPE iLO Drive Array Controller Board ConditionMonitors the Array Controller Board Condition.[CPQIDA-MIB :: cpqDaCntlrBoardCondition : 1.3.6.1.4.1.232.3.2.2.1.1.12] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_drivearray_ControllerBoardStatusHPE iLO Drive Array Controller Board StatusMonitors the Array Controller Board Status.[CPQIDA-MIB :: cpqDaCntlrBoardStatus : 1.3.6.1.4.1.232.3.2.2.1.1.10] Possible values are : 1 : other,2 : ok,3: generalFailure,4 : cableProblem,5 : poweredOff,6 : cacheModuleMissing,7 : degraded.
hpe_ilo_drivearray_ControllerEncryptCspNvramStatusHPE iLO Drive Array Controller Encrypt Csp Nvram StatusMonitors the Array Controller Encryption Critical Security Parameter NVRAM Status.[CPQIDA-MIB :: cpqDaCntlrEncryptCspNvramStatus : 1.3.6.1.4.1.232.3.2.2.1.1.36] Possible values are : 1 : other,2 : ok,3 : detectionFailed.
hpe_ilo_drivearray_ControllerPartnerBoardStatusHPE iLO Drive Array Controller Partner Board StatusMonitors the Array Controller Partner Board Status.[CPQIDA-MIB :: cpqDaCntlrPartnerBoardStatus : 1.3.6.1.4.1.232.3.2.2.1.1.11] Possible values are : 1 : other,2 : ok,3: generalFailure,4 : cableProblem,5 : poweredOff.
hpe_ilo_drivearray_ControllerAccessModuleStatusHPE iLO Drive Array Controller Access Module StatusMonitors the Array Controller RAID ADG Enabler Module Status.[CPQIDA-MIB :: cpqDaCntlrAccessModuleStatus : 1.3.6.1.4.1.232.3.2.2.1.1.18] Possible values are : 1 : other,2 : notSupported,3: notPresent,4 : badSignature,5 : badChecksum,6 : fullyFunctional,7 : upgradeFirmware.
hpe_ilo_drivearray_ControllerPartnerBoardConditionHPE iLO Drive Array Controller Partner Board ConditionMonitors the Array Controller Partner Board Condition.[CPQIDA-MIB :: cpqDaCntlrPartnerBoardCondition : 1.3.6.1.4.1.232.3.2.2.1.1.13] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_drivearray_ControllerCurrentTemperatureHPE iLO Drive Array Controller Current TemperatureCelsiusMonitors the Array Controller Current Temperature.[CPQIDA-MIB :: cpqDaCntlrCurrentTemp : 1.3.6.1.4.1.232.3.2.2.1.1.32]
hpe_ilo_drivearray_ControllerConditionHPE iLO Drive Array Controller ConditionMonitors the condition of the device. This value represents the overall condition of this controller,and any associated logical drives,physical drives,and cache modules.[CPQIDA-MIB :: cpqDaCntlrCondition 1.3.6.1.4.1.232.3.2.2.1.1.6] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_drivearray_ControllerRedundancyErrorHPE iLO Drive Array Controller Redundancy ErrorMonitors the Array Controller Redundancy Error.[CPQIDA-MIB :: cpqDaCntlrRedundancyError : 1.3.6.1.4.1.232.3.2.2.1.1.17] Possible values are : 1 : other,2 : noFailure,3: noRedundantController,4 : differentHardware,5 : noLink,6 : differentFirmware,7 : differentCache,8 : otherCacheFailure,9 : noDrives,10 : otherNoDrives,11 : unsupportedDrives,12 : expandInProgress.
HPE iLO CPQ DA Conditionhpe_ilo_drivearray_MibConditionHPE iLO Drive Array Mib ConditionMonitors the overall condition (status) of the drive array.[CPQIDA-MIB :: cpqDaMibCondition : 1.3.6.1.4.1.232.3.1.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
HPE iLO CPQ DA Logical Drivehpe_ilo_drivearray_LogicalDriveSizeHPE iLO Drive Array Logical Drive SizeMBMonitors the Logical Drive Size.[CPQIDA-MIB :: cpqDaLogDrvSize : 1.3.6.1.4.1.232.3.2.3.1.1.9]
hpe_ilo_drivearray_LogicalDriveStatusHPE iLO Drive Array Logical Drive StatusMonitors the Logical Drive Status.[CPQIDA-MIB :: cpqDaLogDrvStatus : 1.3.6.1.4.1.232.3.2.3.1.1.4] Possible values are : 1 : other,2 : ok,3 : failed,4 : unconfigured,5 : recovering,6 : readyForRebuild,7 : rebuilding,8 : wrongDrive,9 : badConnect,10 : overheating,11 : shutdown,12 : expanding,13 : notAvailable,14 : queuedForExpansion,15 : multipathAccessDegraded,16 : erasing,17: predictiveSpareRebuildReady,18 : rapidParityInitInProgress,19 : rapidParityInitPending,20 : noAccessEncryptedNoCntlrKey,21 : unencryptedToEncryptedInProgress,22 : newLogDrvKeyRekeyInProgress,23 : noAccessEncryptedCntlrEncryptnNotEnbld,24 : unencryptedToEncryptedNotStarted,25 : newLogDrvKeyRekeyRequestReceived,26 : unsupported,27 : offline,28 : sedQualInProgrss,29 : sedQualFailed.
hpe_ilo_drivearray_LogicalDriveConditionHPE iLO Drive Array Logical Drive ConditionMonitors the Logical Drive condition.[CPQIDA-MIB :: cpqDaLogDrvCondition : 1.3.6.1.4.1.232.3.2.3.1.1.11] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
HPE iLO CPQ DA Physical Drivehpe_ilo_drivearray_PhysicalDriveHSeekErrorsHPE iLO Drive Array Physical Drive HSeek ErrorscountMonitors the Seek Errors (High).[CPQIDA-MIB :: cpqDaPhyDrvHSeekErrs : 1.3.6.1.4.1.232.3.2.5.1.1.20]
hpe_ilo_drivearray_PhysicalDriveHardReadErrorsHPE iLO Drive Array Physical Drive Hard Read ErrorscountMonitors the Hard Read Errors.[CPQIDA-MIB :: cpqDaPhyDrvHardReadErrs : 1.3.6.1.4.1.232.3.2.5.1.1.16]
hpe_ilo_drivearray_PhysicalDriveStatusHPE iLO Drive Array Physical Drive StatusMonitors the Physical Drive Status.[CPQIDA-MIB :: cpqDaPhyDrvStatus : 1.3.6.1.4.1.232.3.2.5.1.1.6] Possible values are : 1 : other,2 : ok,3: failed,4 : predictiveFailure,5 : erasing,6 : eraseDone,7 : eraseQueued,8 : ssdWearOut,9 : notAuthenticated.
hpe_ilo_drivearray_PhysicalDriveRecoveredReadErrorsHPE iLO Drive Array Physical Drive Recovered Read ErrorscountMonitors the Recovered Read Errors.[CPQIDA-MIB :: cpqDaPhyDrvRecvReadErrs : 1.3.6.1.4.1.232.3.2.5.1.1.17]
hpe_ilo_drivearray_PhysicalDriveHardWriteErrorsHPE iLO Drive Array Physical Drive Hard Write ErrorscountMonitors the Physical Drive Hard Write Errors.[CPQIDA-MIB :: cpqDaPhyDrvHardWriteErrs : 1.3.6.1.4.1.232.3.2.5.1.1.18]
hpe_ilo_drivearray_PhysicalDriveConditionHPE iLO Drive Array Physical Drive ConditionMonitors the condition of the device. This value represents the overall condition of this physical drive.[CPQIDA-MIB :: cpqDaPhyDrvCondition : 1.3.6.1.4.1.232.3.2.5.1.1.37] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_drivearray_PhysicalDriveSSDWearStatusHPE iLO Drive Array Physical Drive SSD Wear StatusMonitors the Drive Array Physical Drive Solid State Disk Wear Status.[CPQIDA-MIB :: cpqDaPhyDrvSSDWearStatus : 1.3.6.1.4.1.232.3.2.5.1.1.73] Possible values are : 1 : other,2 : ok,3: fiftySixDayThreshold,4 : fivePercentThreshold,5 : twoPercentThreshold,6 : ssdWearOut.
hpe_ilo_drivearray_PhysicalDriveRecoveredWriteErrorsHPE iLO Drive Array Physical Drive Recovered Write ErrorscountMonitors the Physical Drive Recovered Write Errors.[CPQIDA-MIB :: cpqDaPhyDrvRecvWriteErrs : 1.3.6.1.4.1.232.3.2.5.1.1.19]
hpe_ilo_drivearray_PhysicalDriveSeekErrsHPE iLO Drive Array Physical Drive Seek ErrorscountMonitors the Seek Errors (low).[CPQIDA-MIB :: cpqDaPhyDrvSeekErrs : 1.3.6.1.4.1.232.3.2.5.1.1.21]
hpe_ilo_drivearray_PhysicalDriveCurrentTemperatureHPE iLO Drive Array Physical Drive Current TemperatureCelsiusMonitors the Drive Array Physical Drive Current Temperature.[CPQIDA-MIB :: cpqDaPhyDrvCurrentTemperature : 1.3.6.1.4.1.232.3.2.5.1.1.70]
hpe_ilo_drivearray_PhysicalDriveSmartStatusHPE iLO Drive Array Physical Drive Smart StatusMonitors the Physical Drive Smart Status.[CPQIDA-MIB :: cpqDaPhyDrvSmartStatus : 1.3.6.1.4.1.232.3.2.5.1.1.57] Possible values are : 1 : other,2 : ok,3: replaceDrive,4 : replaceDriveSSDWearOut.
HPE iLO CPQ HE Environmenthpe_ilo_AsrConditionHPE iLO Automatic Server Recovery ConditionMonitors the overall condition of the Automatic Server Recovery (ASR) feature.[CPQHLTH-MIB :: cpqHeAsrCondition : 1.3.6.1.4.1.232.6.2.5.17.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_BatteryBackupUnitConditionHPE iLO Battery Backup Unit ConditionMonitors the overall condition of the BBU sub-system.[CPQHLTH-MIB :: cpqHeBbuCondition : 1.3.6.1.4.1.232.6.2.23.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_faulttolerant_PowerSupplyStatusHPE iLO FaultTolerant PowerSupply StatusMonitors the status of the fault tolerant power supply.[CPQHLTH-MIB :: cpqHeFltTolPwrSupplyStatus : 1.3.6.1.4.1.232.6.2.9.2.0] Possible values are : 1 : other,2 : notSupported,3 : notInstalled,4 : installed.
hpe_ilo_ThermalConditionHPE iLO Thermal ConditionMonitors the overall condition of the system's thermal environment.[CPQHLTH-MIB :: cpqHeThermalCondition : 1.3.6.1.4.1.232.6.2.6.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_HardwareBiosConditionHPE iLO Hardware Bios ConditionMonitors an error has been detected during Pre-OS Test (POST) or during initial hardware initialization. Typically,this will be a hardware interlock not closed due to an adapter or cable not properly seated in the slot. The first action is to review the iLO Event Log and iLO Integrated Management Log (IML) for a new event. If no entries found,the server will usually require a physical inspection to identify the source of the issue by observing the external and internal hardware status LEDs.[CPQHLTH-MIB :: cpqHeHWBiosCondition : 1.3.6.1.4.1.232.6.2.16.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_resilient_MemoryConditionHPE iLO Resilient Memory ConditionMonitors the current condition of the Advanced Memory Protection subsystem.[CPQHLTH-MIB :: cpqHeResilientMemCondition : 1.3.6.1.4.1.232.6.2.14.4.0] Possible values are : 1 : other,2 : ok,3 : degraded.
hpe_ilo_ThermalSystemFanStatusHPE iLO Thermal System Fan StatusMonitors the status of the fan(s) in the system.[CPQHLTH-MIB :: cpqHeThermalSystemFanStatus : 1.3.6.1.4.1.232.6.2.6.4.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_EventLogConditionHPE iLO Event Log ConditionMonitors the overall condition of the Integrated Management Log feature.[CPQHLTH-MIB :: cpqHeEventLogCondition : 1.3.6.1.4.1.232.6.2.11.2.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_ThermalCpuFanStatusHPE iLO Thermal Cpu Fan StatusMonitors the status of the processor fan(s) in the system.[CPQHLTH-MIB :: cpqHeThermalCpuFanStatus : 1.3.6.1.4.1.232.6.2.6.5.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_ThermalTemperatureStatusHPE iLO Thermal Temperature StatusMonitors the status of the system's temperature sensors.[CPQHLTH-MIB :: cpqHeThermalTempStatus : 1.3.6.1.4.1.232.6.2.6.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_SystemBackupBatteryConditionHPE iLO System Backup Battery ConditionMonitors the overall condition of the battery backup sub-system.[CPQHLTH-MIB :: cpqHeSysBackupBatteryCondition : 1.3.6.1.4.1.232.6.2.17.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_NvdimmConditionHPE iLO Nvdimm ConditionMonitors the overall condition of the NVDIMM sub-system.[CPQHLTH-MIB :: cpqHeNvdimmCondition : 1.3.6.1.4.1.232.6.2.22.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_faulttolerant_PowerSupplyConditionHPE iLO FaultTolerant PowerSupply ConditionMonitors the overall condition of the fault tolerant power supply sub-system.[CPQHLTH-MIB :: cpqHeFltTolPwrSupplyCondition : 1.3.6.1.4.1.232.6.2.9.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_MibConditionHPE iLO Mib ConditionMonitors the overall status of the server health system.[CPQHLTH-MIB :: cpqHeMibCondition : 1.3.6.1.4.1.232.6.1.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
HPE iLO CPQ HE Fault Tolerant Fan Healthhpe_ilo_faulttolerant_FanPresentHPE iLO Fault Tolerant Fan PresentMonitors if the fan described is present in the system.[CPQHLTH-MIB :: cpqHeFltTolFanLocale : 1.3.6.1.4.1.232.6.2.6.7.1.3,cpqHeFltTolFanPresent : 1.3.6.1.4.1.232.6.2.6.7.1.4] Possible values are : 1 : other,2 : absent,3 : present.
hpe_ilo_faulttolerant_FanSpeedHPE iLO Fault Tolerant Fan SpeedMonitors the speed of the fan.[CPQHLTH-MIB :: cpqHeFltTolFanSpeed : 1.3.6.1.4.1.232.6.2.6.7.1.6] Possible values are : 1 : other,2 : normal,3 : high.
hpe_ilo_faulttolerant_FanConditionHPE iLO Fault Tolerant Fan ConditionMonitors the condition of the fan.[CPQHLTH-MIB :: cpqHeFltTolFanCondition : 1.3.6.1.4.1.232.6.2.6.7.1.9] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
HPE iLO CPQ HE Fault Tolerant Power Supply Healthhpe_ilo_faulttolerant_PowerSupplyErrorConditionHPE iLO FaultTolerant Power Supply Error ConditionMonitors the Error condition of the power supply.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyErrorCondition : 1.3.6.1.4.1.232.6.2.9.3.1.18] Possible values are : 1 : noError,2 : generalFailure,3 : overvoltage,4 : overcurrent,5 : overtemperature,6 : powerinputloss,7 : fanfailure,8 : vinhighwarning,9 : vinlowwarning,10 : vouthighwarning,11 : voutlowwarning,12 : inlettemphighwarning,13 : iinternaltemphighwarning,14 : vauxhighwarning,15 : vauxlowwarning,16 : vauxlowwarning,17: goodinstandby.
hpe_ilo_faulttolerant_PowerSupplyMainVoltageHPE iLO Fault Tolerant Power Supply Main VoltagevMonitors the input main voltage of the power supply in volts.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyMainVoltage : 1.3.6.1.4.1.232.6.2.9.3.1.6]
hpe_ilo_fault_tolerant_PowerSupplyConditionHPE iLO Fault Tolerant Power Supply ConditionMonitors the condition of the power supply.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyCondition : 1.3.6.1.4.1.232.6.2.9.3.1.4] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_faulttolerant_PowerSupplyCapacityUsedHPE iLO Fault Tolerant Power Supply Capacity UsedWMonitors the currently used capacity of the power supply in watts.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyCapacityUsed : 1.3.6.1.4.1.232.6.2.9.3.1.7]
hpe_ilo_faulttolerant_PowerSupplyCapacityMaximumHPE iLO Fault Tolerant Power Supply Capacity MaximumWMonitors the maximum capacity of the power supply in watts.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyCapacityMaximum : 1.3.6.1.4.1.232.6.2.9.3.1.8]
hpe_ilo_fault_tolerant_PowerSupplyStatusHPE iLO Fault Tolerant Power Supply StatusMonitors the status of the power supply.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyStatus : 1.3.6.1.4.1.232.6.2.9.3.1.5] Possible values are : 1 : noError,2 : generalFailure,3 : bistFailure,4 : fanFailure,5 : tempFailure,6 : interlockOpen,7 : epromFailed,8 : vrefFailed,9 : dacFailed,10 : ramTestFailed,11 : voltageChannelFailed,12 : orringdiodeFailed,13 : brownOut,14 : giveupOnStartup,15 : nvramInvalid,16 : calibrationTableInvalid,17: noPowerInput.
HPE iLO CPQ HE Resilient Memory 2 Board Conditionhpe_ilo_resilient_Memory2BoardErrorStatusHPE iLO Resilient Memory 2 Board Error StatusMonitors the error status of the Advanced Memory Protection board or Cartridge or riser.[CPQHLTH-MIB :: cpqHeResMem2BoardErrorStatus : 1.3.6.1.4.1.232.6.2.14.12.1.6] Possible values are : 1 : other,2 : noError,3 : dimmEccError,4 : unlockError,5 : configError,6 : busError,7 : powerError,8 : advancedEcc,9 : onlineSpare,10 : mirrored,11 : mirroredDimmError,12 : memoryRaid,13 : raidDimmError,14 : lockStep,15 : lockStepError,16 : a3dc,17: a3dcError.
hpe_ilo_resilient_Memory2BoardConditionHPE iLO Resilient Memory 2 Board ConditionMonitors the the current status of the Advanced Memory Protection memory board or cartridge or riser.[CPQHLTH-MIB :: cpqHeResMem2BoardCondition : 1.3.6.1.4.1.232.6.2.14.12.1.11] Possible values are : 1 : other,2 : ok,3 : degraded
HPE iLO CPQ HE Resilient Memory 2 Module Conditionhpe_ilo_resilient_Memory2ModuleConditionHPE iLO Resilient Memory 2 Module ConditionMonitors the current status of the correctable memory errors for this memory module.[CPQHLTH-MIB :: cpqHeResMem2ModuleSerialNo : 1.3.6.1.4.1.232.6.2.14.13.1.12,cpqHeResMem2ModuleCondition : 1.3.6.1.4.1.232.6.2.14.13.1.20] Possible values are : 1 : other,2 : ok,3 : degraded,4 : degradedModuleIndexUnknown.
hpe_ilo_resilient_Memory2ModuleStatusHPE iLO Resilient Memory 2 Module StatusMonitors the current status of the correctable memory errors for this memory module.[CPQHLTH-MIB :: cpqHeResMem2ModuleStatus : 1.3.6.1.4.1.232.6.2.14.13.1.19] Possible values are : 1 : other,2 : notPresent,3: present,4 : good,5 : add,6 : upgrade,7 : missing,8 : doesNotMatch,9 : notSupported,10 : badConfig,11 : degraded,12 : spare,13 : partial,14 : configError,15 : trainingFailure.
HPE iLO CPQ HE System Battery Conditionhpe_ilo_SystemBatteryConditionHPE iLO System Battery ConditionMonitors the condition of the backup battery.[CPQHLTH-MIB :: cpqHeSysBatteryCondition : 1.3.6.1.4.1.232.6.2.17.2.1.4] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_SystemBatteryPresentHPE iLO System Battery PresentMonitors whether the backup battery is present in the chassis.[CPQHLTH-MIB :: cpqHeSysBatteryPresent : 1.3.6.1.4.1.232.6.2.17.2.1.3,cpqHeSysBatterySerialNumber : 1.3.6.1.4.1.232.6.2.17.2.1.9] Possible values are : 1 : other,2 : absent,3 : present.
hpe_ilo_SystemBatteryStatusHPE iLO System Battery StatusMonitors the status of the battery.[CPQHLTH-MIB :: cpqHeSysBatteryStatus : 1.3.6.1.4.1.232.6.2.17.2.1.5] Possible values are : 1 : noError,2 : generalFailure,3: shutdownHighResistance,4 : shutdownLowVoltage,5 : shutdownShortCircuit,6 : shutdownChargeTimeout,7 : shutdownOverTemperature,8 : shutdownDischargeMinVoltage,9 : shutdownDischargeCurrent,10 : shutdownLoadCountHigh,11 : shutdownEnablePin,12 : shutdownOverCurrent,13 : shutdownPermanentFailure,14 : shutdownBackupTimeExceeded,15 : predictiveFailure.
HPE iLO CPQ HE Temperature Sensor Healthhpe_ilo_TemperatureConditionHPE iLO Temperature ConditionMonitors the Temperature sensor condition.[CPQHLTH-MIB :: cpqHeTemperatureCondition : 1.3.6.1.4.1.232.6.2.6.8.1.6] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_TemperatureCelsiusHPE iLO Temperature CelsiusCelsiusMonitors the current temperature sensor reading in degrees celsius.[CPQHLTH-MIB :: cpqHeTemperatureLocale : 1.3.6.1.4.1.232.6.2.6.8.1.3,cpqHeTemperatureCelsius : 1.3.6.1.4.1.232.6.2.6.8.1.4]
HPE iLO CPQ NIC Conditionhpe_ilo_NicMibConditionHPE iLO NIC Mib ConditionMonitors the overall status of the NIC.[CPQNIC-MIB :: cpqNicMibCondition : 1.3.6.1.4.1.232.18.1.3.0] Possible values are : 1 : unknown,2 : ok,3 : degraded,4 : failed.
HPE iLO CPQ SE CPU Cache Statushpe_ilo_se_CpuCacheStatusHPE iLO SE CPU Cache StatusMonitors the status of the cache unit. If the cache is optional and not installed,unknown(1) will be returned.[CPQSTDEQ-MIB :: cpqSeCpuCacheUnitIndex : 1.3.6.1.4.1.232.1.2.2.3.1.1,cpqSeCpuCacheLevelIndex : 1.3.6.1.4.1.232.1.2.2.3.1.2,cpqSeCpuCacheStatus : 1.3.6.1.4.1.232.1.2.2.3.1.5] Possible values are : 1 : unknown,2 : ok,3 : degraded,4 : failed.
HPE iLO CPQ SE CPU Statushpe_ilo_se_CpuStatusHPE iLO SE CPU StatusMonitors the status of the processor.[CPQSTDEQ-MIB :: cpqSeCpuStatus : 1.3.6.1.4.1.232.1.2.2.1.1.6] Possible values are : 1 : unknown,2 : ok,3 : degraded,4 : failed,5 : disabled.
HPE iLO CPQ SE Overall Conditionhpe_ilo_se_MibConditionHPE iLO SE Mib ConditionMonitors the overall condition of the server.[CPQSTDEQ-MIB :: cpqSeMibCondition : 1.3.6.1.4.1.232.1.1.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_se_CpuConditionHPE iLO SE CPU ConditionMonitors the the overall condition of the processor sub-system.[CPQSTDEQ-MIB :: cpqSeCpuCondition : 1.3.6.1.4.1.232.1.2.2.4.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
HPE iLO CPQ SI Conditionhpe_ilo_server_information_MibConditionHPE iLO Server Information Mib ConditionMonitors the overall status of the CPQ server information.[CPQSINFO-MIB :: cpqSiMibCondition : 1.3.6.1.4.1.232.2.1.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
HPE iLO CPQ SM2 ILOhpe_ilo_sm2_MibConditionHPE iLO SM2 Mib ConditionMonitors the overall condition of the Remote Insight/ Integrated Lights-Out.[CPQSM2-MIB :: cpqSm2MibCondition : 1.3.6.1.4.1.232.9.1.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_sm2_ControllerExternalPowerCableStatusHPE iLO SM2 Controller External PowerCable StatusMonitors the Remote Insight External Power Cable Status.[CPQSM2-MIB :: cpqSm2CntlrExternalPowerCableStatus : 1.3.6.1.4.1.232.9.2.2.25.0] Possible values are : 1 : other,2 : externallyConnected,3 : disconnected,4 : internallyConnected,5 : externallyAndInternallyConnected,6 :notApplicable.
hpe_ilo_sm2_ControllerBatteryStatusHPE iLO SM2 Controller Battery StatusMonitors the remote insight battery status.[CPQSM2-MIB :: cpqSm2CntlrBatteryStatus : 1.3.6.1.4.1.232.9.2.2.5.0] Possible values are : 1 : other,2 : batteryOk,3 : batteryFailed,4 : batteryDisconnected.
hpe_ilo_sm2_ControllerInterfaceStatusHPE iLO SM2 Controller Interface StatusMonitors the Remote Insight/ Integrated Lights-Out Interface Status.[CPQSM2-MIB :: cpqSm2CntlrInterfaceStatus : 1.3.6.1.4.1.232.9.2.2.17.0] Possible values are : 1 : other,2 : ok,3 : notResponding.
hpe_ilo_sm2_ControllerVirtualPowerCableStatusHPE iLO SM2 Controller Virtual PowerCable StatusMonitors the Remote Insight Virtual Power Cable Status.[CPQSM2-MIB :: cpqSm2CntlrVirtualPowerCableStatus : 1.3.6.1.4.1.232.9.2.2.24.0] Possible values are : 1 : other,2 : connected,3 : disconnected,4 : notApplicable.
HPE iLO CPQ SM2 NIC Conditionhpe_ilo_sm2_NicConditionHPE iLO SM2 NIC ConditionMonitors the overall condition of the Remote Insight / Integrated Lights-Out Network Interface Controller (NIC).[CPQSM2-MIB :: cpqSm2NicLocation : 1.3.6.1.4.1.232.9.2.5.1.1.1,cpqSm2NicCondition : 1.3.6.1.4.1.232.9.2.5.1.1.11] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
HPE iLO NIC Physical Adapterhpe_ilo_nic_PhysicalAdapterInternalMacTransmitErrorsHPE iLO NIC Physical Adapter Internal Mac Transmit ErrorscountMonitors the count of frames for which transmission on a particular interface fails due to an internal MAC sublayer transmit error.[CPQNIC-MIB :: cpqNicIfPhysAdapterInternalMacTransmitErrors : 1.3.6.1.4.1.232.18.2.3.1.1.27]
hpe_ilo_nic_PhysicalAdapterFCSErrorsHPE iLO NIC Physical Adapter FCS ErrorscountMonitors the count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check.[CPQNIC-MIB :: cpqNicIfPhysAdapterFCSErrors : 1.3.6.1.4.1.232.18.2.3.1.1.21]
hpe_ilo_nic_PhysicalAdapterDeferredTransmissionsHPE iLO NIC Physical Adapter Deferred TransmissionscountMonitors the number of packets deferred before transmission. This counter contains the number of packets whose transmission was delayed on its first attempt because the medium was busy. Packets involved in any collisions are not counted. Frames that wait before transmission are counted.This statistic will be incremented often during normal operation on a busy network.[CPQNIC-MIB :: cpqNicIfPhysAdapterDeferredTransmissions : 1.3.6.1.4.1.232.18.2.3.1.1.24]
hpe_ilo_nic_PhysicalAdapterStatusHPE iLO NIC Physical Adapter StatusMonitors the physical adapter status.[CPQNIC-MIB :: cpqNicIfPhysAdapterStatus : 1.3.6.1.4.1.232.18.2.3.1.1.14] Possible values are : 1 : unknown,2 : ok,3 : generalFailure,4 : linkFailure.
hpe_ilo_nic_PhysicalAdapterMultipleCollisionFramesHPE iLO NIC Physical Adapter Multiple Collision FramescountMonitors the number of multiple collision packets. This counter contains the number of packets that are involved in multiple collisions and are subsequently transmitted successfully.[CPQNIC-MIB :: cpqNicIfPhysAdapterMultipleCollisionFrames : 1.3.6.1.4.1.232.18.2.3.1.1.23]
hpe_ilo_nic_PhysicalAdapterSingleCollisionFramesHPE iLO NIC Physical Adapter Single Collision FramescountMonitors the number of single collision packets. This counter contains the number of packets that are involved in a single collision and are subsequently transmitted successfully.[CPQNIC-MIB :: cpqNicIfPhysAdapterSingleCollisionFrames : 1.3.6.1.4.1.232.18.2.3.1.1.22]
hpe_ilo_nic_PhysicalAdapterStateHPE iLO NIC Physical Adapter StateMonitors the fault tolerant state of this adapter.[CPQNIC-MIB :: cpqNicIfPhysAdapterState : 1.3.6.1.4.1.232.18.2.3.1.1.13] Possible values are : 1 : unknown,2 : active,3 : standby,4 : failed.
hpe_ilo_nic_PhysicalAdapterAlignmentErrorsHPE iLO NIC Physical Adapter Alignment ErrorscountMonitors the count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check.The alignment of a frame is checked by the receiver after the packet has failed the Cyclical Redundancy Check (CRC). Misaligned packets do not end on an 8-bit boundary.All packets contain a set number of bytes and must end after a defined number of bytes.Packets that do not end on a byte boundary fail the alignment check.[CPQNIC-MIB :: cpqNicIfPhysAdapterAlignmentErrors : 1.3.6.1.4.1.232.18.2.3.1.1.20]
hpe_ilo_nic_PhysicalAdapterBadTransmitsHPE iLO NIC Physical Adapter Bad TransmitscountMonitors the count of frames that were not transmitted by the adapter because of an error.[CPQNIC-MIB :: cpqNicIfPhysAdapterBadTransmits : 1.3.6.1.4.1.232.18.2.3.1.1.18]
hpe_ilo_nic_PhysicalAdapterLateCollisionsHPE iLO NIC Physical Adapter Late CollisionscountMonitors the Late collisions may be a symptom of cabling problems.[CPQNIC-MIB :: cpqNicIfPhysAdapterLateCollisions : 1.3.6.1.4.1.232.18.2.3.1.1.25]
hpe_ilo_nic_PhysicalAdapterBadReceivesHPE iLO NIC Physical Adapter Bad ReceivescountMonitors the count of frames that were received by the adapter but which had an error.[CPQNIC-MIB :: cpqNicIfPhysAdapterBadReceives : 1.3.6.1.4.1.232.18.2.3.1.1.19]
hpe_ilo_nic_PhysicalAdapterInternalMacReceiveErrorsHPE iLO NIC Physical Adapter Internal Mac Receive ErrorscountMonitors the count of frames for which reception on a particular interface fails due to an internal MAC sublayer receive error.[CPQNIC-MIB :: cpqNicIfPhysAdapterInternalMacReceiveErrors : 1.3.6.1.4.1.232.18.2.3.1.1.30]
hpe_ilo_nic_PhysicalAdapterConditionHPE iLO NIC Physical Adapter ConditionMonitors the condition of this physical adapter.[CPQNIC-MIB :: cpqNicIfPhysAdapterCondition : 1.3.6.1.4.1.232.18.2.3.1.1.12] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed.
hpe_ilo_nic_PhysicalAdapterExcessiveCollisionsHPE iLO NIC Physical Adapter Excessive CollisionscountMonitors the number of packets aborted during transmission due to excessive collisions.[CPQNIC-MIB :: cpqNicIfPhysAdapterExcessiveCollisions : 1.3.6.1.4.1.232.18.2.3.1.1.26]
hpe_ilo_nic_PhysicalAdapterCarrierSenseErrorsHPE iLO NIC Physical Adapter Carrier Sense ErrorscountMonitors the number of packets transmitted with carrier sense errors.[CPQNIC-MIB :: cpqNicIfPhysAdapterCarrierSenseErrors : 1.3.6.1.4.1.232.18.2.3.1.1.28]

HPE LeftHand SAN Cluster - G2

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Manager Statuslefthand.cluster.managerCluster Manager StatusProvides the manager name and status. Possible Manager status are 1- Up,2- Down.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.44.1.2,1.3.6.1.4.1.9804.3.1.1.2.12.44.1.5,1.3.6.1.4.1.9804.3.1.1.2.12.44.1.7,1.3.6.1.4.1.9804.3.1.1.2.12.44.1.9]

HPE LeftHand SAN Cluster - G3

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Performance Monitorlefthand.cluster.available.spaceCluster Available SpaceGBSpace available to create volumes. Here used space will be subtracted from total space.

HPE LeftHand SAN Cluster - G4

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Performance Monitorlefthand.cluster.total.spaceCluster Total SpaceGBThe total space for data storage in the cluster.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.48.1.29]

HPE LeftHand SAN Cluster - G5

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Performance Monitorlefthand.cluster.used.spaceCluster Used SpaceGBThe amount of storage space that has been used in the cluster.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.48.1.31]

HPE LeftHand SAN Cluster - G6

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Performance Monitorlefthand.cluster.space.utilizationCluster Space Utilization%The percentage of storage space that has been used in the cluster. Here used space and total space metrics are used for calculating utilization.

HPE LeftHand SAN Cluster - G7

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Performance Monitorlefthand.cluster.read.latencyCluster Read LatencymsThe total time spent waiting for read operations to complete in the cluster. The difference between current and the previous value of clusClusterStatsIoLatencyRead object will be considered.[OID:1.3.6.1.4.1.9804.3.1.1.2.12.48.1.26]

HPE LeftHand SAN Cluster - G8

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Performance Monitorlefthand.cluster.write.latencyCluster Write LatencymsThe total time spent waiting for write operations to complete in the cluster. The difference between current and the previous value of clusClusterStatsIoLatencyWrite object will be considered.[OID:1.3.6.1.4.1.9804.3.1.1.2.12.48.1.27]

HPE LeftHand SAN Cluster - G9

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Volume Snapshot Monitorlefthand.cluster.volume.snapshot.latency.readSnapshot Latency ReadmsThe total time spent waiting for read operations to complete on the snapshot.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.101.1.42]

HPE LeftHand SAN Cluster - G10

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Volume Snapshot Monitorlefthand.cluster.volume.snapshot.latency.writeSnapshot Latency WritemsThe total time spent waiting for write operations to complete on the snapshot.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.101.1.43]

HPE LeftHand SAN Cluster - G11

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Volume Snapshot Monitorlefthand.cluster.volume.snapshot.used.percentSnapshot Used Percent%The space used by the snapshot as a percentage of the cluster space.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.101.1.31]

HPE LeftHand SAN Cluster - G12

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Volume Snapshot Monitorlefthand.cluster.volume.snapshot.replication.statusSnapshot Replication StatusThe snapshot replication status. The status will be normal if the snapshot is available,faulty otherwise.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.101.1.14]

HPE LeftHand SAN Cluster - G13

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Volume Spacelefthand.cluster.volume.sizeCluster Volume SizeGBThe volume size of the cluster. (Reported Size) [OID: 1.3.6.1.4.1.9804.3.1.1.2.12.97.1.5]

HPE LeftHand SAN Cluster - G14

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Volume Spacelefthand.cluster.volume.available.spaceCluster Volume Available SpaceGBThe storage space available in the volume before the size is reached. For thinly provisioned volumes the cluster must have sufficient storage space to support this.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.97.1.51]

HPE LeftHand SAN Cluster - G15

Description

Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP LeftHand SAN Cluster Volume Spacelefthand.cluster.volume.used.percentCluster Volume Used Percent%The percentage of storage space that has been used on the volume.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.97.1.52]

HPE LeftHand SAN Health Check - G2

Description

This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand Cache Statuslefthand.san.health.cache.statusCache StatusThe RAID controller cache status. Possible values are 1 - Pass 2 - Failed [OID: 1.3.6.1.4.1.9804.3.1.1.2.1.91.1.91]

HPE LeftHand SAN Health Check - G3

Description

This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand Cache Statuslefthand.san.health.cache.bbu.statusBattery Backup Unit(BBU) StatusGives cache's BBU (Battery Backup Unit) status. Possible values are 1.Pass 2.Fail [OID:1.3.6.1.4.1.9804.3.1.1.2.1.91.1.23]

HPE LeftHand SAN Health Check - G4

Description

This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand Fan Statuslefthand.fan.statusFan StatusIt monitors the fan status.[OIDs:1.3.6.1.4.1.9804.3.1.1.2.1.111.1.90,1.3.6.1.4.1.9804.3.1.1.2.1.111.1.91]

HPE LeftHand SAN Health Check - G5

Description

This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand Power Statuslefthand.power.supply.statePower Supply StateIt returns power supply state and status.[OID:1.3.6.1.4.1.9804.3.1.1.2.1.131.1.90,1.3.6.1.4.1.9804.3.1.1.2.1.131.1.91]

HPE LeftHand SAN Health Check - G6

Description

This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand Storage Device Smart Health Statusstorage.device.smart.health.statusStorage Device Smart Health StatusThe device SMART health status. Possible values are 1. Pass 2. Fail.[OID:1.3.6.1.4.1.9804.3.1.1.2.4.2.1.18]

HPE LeftHand SAN Health Check - G7

Description

This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand Temperature Statuslefthand.temperature.sensor.valueTemperature Sensor ValueCelsiusThe temperature sensor value in Celsius.[OID:1.3.6.1.4.1.9804.3.1.1.2.1.121.1.3]

HPE LeftHand SAN Health Check - G8

Description

This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand Temperature Statuslefthand.temperature.sensor.statusTemperature Sensor StatusThe temperature sensor status. Passible values are 1.Pass 2.Fail [OID: 1.3.6.1.4.1.9804.3.1.1.2.1.121.1.91]

HPE LeftHand SAN Health Check - G9

Description

This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand Voltage Sensor Statuslefthand.voltage.sensor.valueVoltage Sensor ValuevThe voltage sensor value in Volts.[OID:1.3.6.1.4.1.9804.3.1.1.2.1.141.1.3]

HPE LeftHand SAN Health Check - G10

Description

This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand Voltage Sensor Statuslefthand.voltage.sensor.statusVoltage Sensor StatusThe voltage sensor status.Possible values are 1- Pass,2- Fail.[OID: 1.3.6.1.4.1.9804.3.1.1.2.1.141.1.91]

HPE LeftHand SAN NSM Storage Status - G2

Description

Applicable on LeftHand SAN NSM devices. Monitors the storage device status and the raid status on the NSM storage.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand NSM Raid Statuslefthand.raid.statusRaid StatusMonitors the RAID status. Possible values are 1- pass,2- fail.[OIDs: 1.3.6.1.4.1.9804.3.1.1.2.4.11.0,1.3.6.1.4.1.9804.3.1.1.2.4.23.0,1.3.6.1.4.1.9804.3.1.1.2.4.24.0]
Lefthand NSM Storagelefthand.storage.device.statusStorage Device StatusMonitors the storage device status. Possible values are 1- pass,2- fail.[OIDs: 1.3.6.1.4.1.9804.3.1.1.2.4.2.1.14,1.3.6.1.4.1.9804.3.1.1.2.4.2.1.90,1.3.6.1.4.1.9804.3.1.1.2.4.2.1.91]

HPE LeftHand SAN NUS Storage Status - G2

Description

Applicable on HP Lefthand SAN NUS devices. Monitors the raid status and the storage device temperature.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Lefthand NUS Raid Statuslefthand.nus.raid.statusRaid StatusMonitors the status of raid subsystem. Possible values are 1 - Normal 2 - Rebuilding 3 - Degraded 4 - Not rebuilding 5 - Off.[OID: 1.3.6.1.4.1.9804.3.1.1.2.4.7.0]
Lefthand NUS Storagelefthand.nus.storage.device.temperatureStorage Device StatusCMonitors the storage device temperature.[OIDs: 1.3.6.1.4.1.9804.3.1.1.2.4.2.1.2,1.3.6.1.4.1.9804.3.1.1.2.4.2.1.3,1.3.6.1.4.1.9804.3.1.1.2.4.2.1.5,1.3.6.1.4.1.9804.3.1.1.2.4.2.1.9]

HP Procurve Switch - G2

Description

Monitoring template for HP Procurve switches. Monitors memory usage,CPU utilization,System temperature,chassis sensor status,power supply state,power supply temperature,fan status and uptime.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP ICF Chassis Module Statusmodule.statusModule StatusModule status: A textual description of the card plugged into this slot in this chassis,including the product number and version information. Specifically,hpicfSlotDesc (1.3.6.1.4.1.11.2.14.11.1.2.3.1.4) will throw three possible values back:1. A description of the module installed in the slot. (Example: "HP J9534A 24p Gig-T PoE+ v2 zl Module")2. An empty slot description ("Slot Available")3. A failure message ("Module Failed") for a failed,non-empty slot. Alert will generate on #3 condition(i.e "Module Failed").
HP ICF Fanhp.icf.fan.stateFan StateThe current state of the HP Switch fan.[OID: 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.4]
HP ICF Power Supplyhp.icf.ps.statePower Supply StateThe physical state of the switch power supply entity.[OID: 1.3.6.1.4.1.11.2.14.11.5.1.55.1.1.1.2]
hp.icf.ps.temperaturePower Supply TemperatureCelsiusThe temperature of the power supply in Celsius.[OID: 1.3.6.1.4.1.11.2.14.11.5.1.55.1.1.1.4]
HP Procurve CPU Utilizationsystem.cpu.utilizationCPU Utilization%It represents the HP ProCurve CPU Utilization.
HP Procurve Global Memory Utilizationsystem.memory.util.percentMemory Utilization%The system dynamic memory utilization,in unit of percentage. Memory Utilization is the percent of memory used in comparison to the total memory bytes and used memory bytes.
HP Procurve Sensor Statushp.procurve.sensor.statusHP Procurve Sensor StatusActual status indicated by the HP Procurve sensor. These are the possible sensor values(1: Unknown 2: Bad 3: Warning 4: Good 5: NotPresent).
HP ProCurve System Temperaturesystem.temperatureSystem TemperatureCIt monitors the system temperature of HP Switches which support the HP-ICF-CHASSIS-MIB.
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

HPE Proliant - Array Controller Monitors

Description

It is applicable for HPE Proliant blade systems which have the Compaq/HPs Insight Manager SNMP agents installed on either Windows or Linux machines.Monitors the status of the array controller,logical and physical drives and rack servers along with the environmental parameters like fan,power and temperature.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
CPQ DA Array Controller Statusarraycontroller.statusCPQ DA Array Controller ConditionMonitors the overall condition of this controller,and any associated logical drives,physical drives,and array accelerators. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.2.1.1.1,1.3.6.1.4.1.232.3.2.2.1.1.6]
CPQ DA Logical Drivelogical.disk.statusCPQ DA Logical Drive ConditionMonitors the overall condition of this logical drive and any associated physical drives. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.3.1.1.1,1.3.6.1.4.1.232.3.2.3.1.1.2,1.3.6.1.4.1.232.3.2.3.1.1.11]
CPQ DA Physical Drivecpq.da.physical.drive.conditionCPQ DA Physical Drive ConditionMonitors the overall condition of this physical drive. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.5.1.1.1,1.3.6.1.4.1.232.3.2.5.1.1.2,1.3.6.1.4.1.232.3.2.5.1.1.37]
cpq.da.physical.drive.smartstatusCPQ DA Physical Drive SMART StatusMonitors the physical drive S.M.A.R.T status. Possible values are 1- other: The agent is unable to determine if the status of S.M.A.R.T predictive failure monitoring for this drive,2- ok: Indicates the drive is functioning properly,3- replaceDrive: Indicates that the drive has a S.M.A.R.T predictive failure error and should be replaced.[OIDs: 1.3.6.1.4.1.232.3.2.5.1.1.1,1.3.6.1.4.1.232.3.2.5.1.1.2,1.3.6.1.4.1.232.3.2.5.1.1.57]
CPQ Rack Fan Enclosure Statushp.proliant.rack.fan.enclosure.statusRack Fan Enclosure StatusRack Fan Enclosure Status. Possible values are other(1) - Fan status detection is not supported. ok(2) - The fan is operating properly. degraded(2) - A redundant fan is not operating properly. failed(4) - A non-redundant fan is not operating properly.[OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.1,1.3.6.1.4.1.232.22.2.3.1.3.1.2,1.3.6.1.4.1.232.22.2.3.1.3.1.3,1.3.6.1.4.1.232.22.2.3.1.3.1.4,1.3.6.1.4.1.232.22.2.3.1.3.1.11]
CPQ Rack Power Enclosure Statusrack.power.enclosure.statusRack Power Enclosure StatusRack Power Enclosure Status. Possible values are 1- Other,2-OK,3- Degraded.[OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.1,1.3.6.1.4.1.232.22.2.3.3.1.1.2,1.3.6.1.4.1.232.22.2.3.3.1.1.3,1.3.6.1.4.1.232.22.2.3.3.1.1.9]
CPQ Rack Power Statusrack.power.statusRack Power StatusPower supply status. Possible values are other(1) - The status could not be determined or not present. ok(2) - The power supply is operating normally. degraded(3) - A temperature sensor,fan or other power supply component is outside of normal operating range. failed(4) - A power supply component detects a condition that could possibly damage the system.[OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.1,1.3.6.1.4.1.232.22.2.5.1.1.1.2,1.3.6.1.4.1.232.22.2.5.1.1.1.3,1.3.6.1.4.1.232.22.2.5.1.1.1.4,1.3.6.1.4.1.232.22.2.5.1.1.1.17]
CPQ Rack Server Blade Statushp.proliant.rack.server.blade.statusRack Server Blade StatusThe health status of the blade. Possible values are 1 - Other,2 -OK,3 - Degraded,4 - Failed.[OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.1,1.3.6.1.4.1.232.22.2.4.1.1.1.2,1.3.6.1.4.1.232.22.2.4.1.1.1.3,1.3.6.1.4.1.232.22.2.4.1.1.1.4,1.3.6.1.4.1.232.22.2.4.1.1.1.5,1.3.6.1.4.1.232.22.2.4.1.1.1.21]
CPQ Rack Server Temperature Statushp.proliant.rack.server.temperature.statusRack Server Temperature StatusThe Temperature sensor status of Rack server. Possible values are other(1) - Temperature could not be determined. ok(2) - The temperature sensor is within the normal operating range. degraded(3) - The temperature sensor is outside of the normal operating range. failed(4) - The temperature sensor detects a condition that could possibly overheat the system.[OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.1,1.3.6.1.4.1.232.22.2.4.3.1.1.2,1.3.6.1.4.1.232.22.2.4.3.1.1.3,1.3.6.1.4.1.232.22.2.4.3.1.1.4,1.3.6.1.4.1.232.22.2.4.3.1.1.10]
CPQ Rack Temperature Enclosure Statushp.proliant.rack.temperature.enclosure.statusRack Temperature Enclosure StatusThe Temperature sensor status. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.22.2.3.1.2.1.1,1.3.6.1.4.1.232.22.2.3.1.2.1.2,1.3.6.1.4.1.232.22.2.3.1.2.1.3,1.3.6.1.4.1.232.22.2.3.1.2.1.4,1.3.6.1.4.1.232.22.2.3.1.2.1.8]

HPE Proliant - Rack Monitors

Description

It is applicable for HPE Proliant blade systems which have the Compaq/HPs Insight Manager SNMP agents installed on either Windows or Linux machines and also on HP switches meant for HP Blade systems. Monitors the rack enclosure status and status of the rack servers along with the environmental parameters like fan,power and temperature. For example,GbE2c Ethernet Blade switch.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
CPQ Rack Enclosure Statusenclosure.statusEnclosure StatusThe overall condition of the enclosure. This is the aggregate of the temperature sensors,fans,and fuses within the enclosure. Possible values are other(1) - No temperature sensors,fans,or fuses in the enclosure or the state could no be determined. ok(2) - All temperature sensors,fans,and fuses are within the normal operating range. degraded(3) - One or more temperature sensors,fans,or fuses are outside of the normal operating range. None are failed. failed(4) - The temperature sensor exceeded the critical threshold value,a required fan has failed,or a fuse has been tripped.[OIDs: 1.3.6.1.4.1.232.22.2.3.1.1.1.9,1.3.6.1.4.1.232.22.2.3.1.1.1.16]
CPQ Rack Fan Enclosure Statushp.proliant.rack.fan.enclosure.statusRack Fan Enclosure StatusRack Fan Enclosure Status. Possible values are other(1) - Fan status detection is not supported. ok(2) - The fan is operating properly. degraded(2) - A redundant fan is not operating properly. failed(4) - A non-redundant fan is not operating properly.[OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.1,1.3.6.1.4.1.232.22.2.3.1.3.1.2,1.3.6.1.4.1.232.22.2.3.1.3.1.3,1.3.6.1.4.1.232.22.2.3.1.3.1.4,1.3.6.1.4.1.232.22.2.3.1.3.1.11]
CPQ Rack Power Enclosure Statusrack.power.enclosure.statusRack Power Enclosure StatusRack Power Enclosure Status. Possible values are 1- Other,2-OK,3- Degraded.[OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.1,1.3.6.1.4.1.232.22.2.3.3.1.1.2,1.3.6.1.4.1.232.22.2.3.3.1.1.3,1.3.6.1.4.1.232.22.2.3.3.1.1.9]
CPQ Rack Power Statusrack.power.statusRack Power StatusPower supply status. Possible values are other(1) - The status could not be determined or not present. ok(2) - The power supply is operating normally. degraded(3) - A temperature sensor,fan or other power supply component is outside of normal operating range. failed(4) - A power supply component detects a condition that could possibly damage the system.[OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.1,1.3.6.1.4.1.232.22.2.5.1.1.1.2,1.3.6.1.4.1.232.22.2.5.1.1.1.3,1.3.6.1.4.1.232.22.2.5.1.1.1.4,1.3.6.1.4.1.232.22.2.5.1.1.1.17]
CPQ Rack Server Blade Statushp.proliant.rack.server.blade.statusRack Server Blade StatusThe health status of the blade. Possible values are 1 - Other,2 -OK,3 - Degraded,4 - Failed.[OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.1,1.3.6.1.4.1.232.22.2.4.1.1.1.2,1.3.6.1.4.1.232.22.2.4.1.1.1.3,1.3.6.1.4.1.232.22.2.4.1.1.1.4,1.3.6.1.4.1.232.22.2.4.1.1.1.5,1.3.6.1.4.1.232.22.2.4.1.1.1.21]
CPQ Rack Server Temperature Statushp.proliant.rack.server.temperature.statusRack Server Temperature StatusThe Temperature sensor status of Rack server. Possible values are other(1) - Temperature could not be determined. ok(2) - The temperature sensor is within the normal operating range. degraded(3) - The temperature sensor is outside of the normal operating range. failed(4) - The temperature sensor detects a condition that could possibly overheat the system.[OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.1,1.3.6.1.4.1.232.22.2.4.3.1.1.2,1.3.6.1.4.1.232.22.2.4.3.1.1.3,1.3.6.1.4.1.232.22.2.4.3.1.1.4,1.3.6.1.4.1.232.22.2.4.3.1.1.10]
CPQ Rack Temperature Enclosure Statushp.proliant.rack.temperature.enclosure.statusRack Temperature Enclosure StatusThe Temperature sensor status. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.22.2.3.1.2.1.1,1.3.6.1.4.1.232.22.2.3.1.2.1.2,1.3.6.1.4.1.232.22.2.3.1.2.1.3,1.3.6.1.4.1.232.22.2.3.1.2.1.4,1.3.6.1.4.1.232.22.2.3.1.2.1.8]

HPE Proliant - Server Health Monitors

Description

This template is used for checking different health parameters of Compaq and HPE Proliant Servers. Monitors CPU fan thermal health,temperature sensor health,system fans health,over server thermal health,chassis fan health,etc. It is also applicable for HPE Proliant servers/blade systems which have the Compaq/HPs insight Manager SNMP agents installed on either Windows or Linux machines. Monitors the CPU and environmental parameters like fan,power and temperature across the different components in the system.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
CPQ HE Environmentcpu.fan.thermal.healthCPQ CPU Fan Thermal HealthProvides the status of the processor fan(s) in the system. This value will be one of the following:- other(1): Fan status detection is not supported by this system or driver,ok(2): All fans are operating properly,failed(4): A fan is not operating properly. System will be shutdown if the failed(4) condition occurs.[OID: 1.3.6.1.4.1.232.6.2.6.5.0]
temperature.sensors.healthCPQ System Temperature Sensors StatusProvides the status of the system's temperature sensors. This value will be one of the following:- other(1): Temp sensing is not supported by this system or driver,ok(2): All temp sensors are within normal operating range,degraded(3): A temp sensor is outside of normal operating range,failed(4): A temp sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results.[OIDs: 1.3.6.1.4.1.232.6.2.6.3.0]
system.fans.healthCPQ System Fans StatusThe status of the fan(s) in the system. This value will be one of the following:- other(1): Fan status detection is not supported by this system or driver,ok(2): All fans are operating properly,degraded(3): A non-required fan is not operating properly,failed(4): A required fan is not operating properly.[OID: 1.3.6.1.4.1.232.6.2.6.4.0]
over.server.thermal.healthCPQ Thermal Environment Overall HealthSpecifies the overall condition of the system's thermal environment.[OID: 1.3.6.1.4.1.232.6.2.6.1.0]
hp.ilo.cpq.he.conditionCPQ Server Health System Overall StatusMonitors the overall status of the server health system. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.1.3.0]
hp.ilo.cpq.he.asr.conditionCPQ Server Health ASR Overall ConditionMonitors the overall condition of the Automatic Server Recovery (ASR) feature. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.5.17.0]
hp.ilo.cpq.he.eventlog.conditionCPQ HE Event Log ConditionMonitors the overall condition of the integrated management log feature. Possible values are 1- Other,2- OK,3- degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.11.2.0]
hp.ilo.cpq.he.resillent.memory.conditionCPQ HE Resilient Memory ConditionMonitors the current condition of the Advanced Memory Protection subsystem. Possible values are 1- other: The system does not support fault tolerant memory or the state cannot be determined by the Management Agent,2- ok: This system is operating normally,3- degraded: The system is running in a degraded state because the Advanced Memory Protection subsystem has been engaged.[OID: 1.3.6.1.4.1.232.6.2.14.4.0]
cpq.ss.conditionCPQ Storage System Overall ConditionMonitors the overall condition (status) of the storage system. Possible values are 1- Other,2- OK,3- Degraded.[OID: 1.3.6.1.4.1.232.8.1.3.0]
cpq.he.fault.tolerant.powersupply.conditionCPQ HE Fault Tolerant Power Supply ConditionMonitors the overall condition of the fault tolerant power supply sub-system. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.9.1.0]
CPQ HE Fault Tolerant Fan Healthfault.tolerant.fan.statusCPQ HE Fault Tolerent Fan HealthProvides the condition of the fan. Possible values are 1- other: Fan status detection is not supported by this system or driver,2- ok: The fan is operating properly,3- degraded: A redundant fan is not operating properly,4- failed: A non-redundant fan is not operating properly.[OIDs: 1.3.6.1.4.1.232.6.2.6.7.1.1,1.3.6.1.4.1.232.6.2.6.7.1.2,1.3.6.1.4.1.232.6.2.6.7.1.9]
CPQ HE Power Supply Healthfault.tolerant.power.supply.statusCPQ Fault Tolerant Power Supply HealthMonitors the condition of the power supply. Possible values are 1- other: The status could not be determined or not present,2- ok: The power supply is operating normally,3- degraded: Power supply is outside of normal operating range,4- failed: power supply component detects a condition that could permanently damage the system.[OIDs: 1.3.6.1.4.1.232.6.2.9.3.1.4,1.3.6.1.4.1.232.6.2.9.3.1.1,1.3.6.1.4.1.232.6.2.9.3.1.2]
CPQ HE Temperature Sensor Healthtemperature.sensor.statusCPQ Temperature Sensor HealthMonitors the temperature sensor condition. Possible values are 1- other: Temperature could not be determined,2- ok: The temperature sensor is within normal operating range,3- degraded: The temperature sensor is outside of normal operating range,4- failed: The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results.[OIDs: 1.3.6.1.4.1.232.6.2.6.8.1.6,1.3.6.1.4.1.232.6.2.6.8.1.1,1.3.6.1.4.1.232.6.2.6.8.1.2]
CPQ Host CPU Utilizationcpu.usageCPQ Host CPU Utilization%Monitors the The CPU utilization as a percentage of the theoretical maximum during the last five minutes. A value of -1 indicates that no CPU utilization information is available for this processor.[OID: 1.3.6.1.4.1.232.11.2.3.1.1.3,1.3.6.1.4.1.232.11.2.3.1.1.1]
CPQ SE CPU Statuscpu.healthCPQ CPU StatusThe status of the processor. Possible values are 1- Unknown: The status of the CPU could not be determined,2- OK: The CPU is functioning normally,3- Degraded: The CPU is in a pre-failure warrantee state,4- Failed: The CPU is in a failed state,5- Disabled: The CPU has been disabled during power-on-self-test.[OIDs: 1.3.6.1.4.1.232.1.2.2.1.1.3,1.3.6.1.4.1.232.1.2.2.1.1.6]

HPE Switch - Performance

Description

Monitors the Hpe Switch Performance Statistics like CPU Utilization per Process, Overall CPU Process Utilization, Memory Utilization.[HP-SWITCHING-MIB :: agentSwitchCpuProcessPercentageUtilization : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.8.1.3, agentSwitchCpuProcessTotalUtilization : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.9.0].Validated on HPE OfficeConnect Switch 1920S 24G 2SFP JL381A, PD.01.05, sysObjectId: 1.3.6.1.4.1.11.2.3.7.11.184.

Prerequisites

Device must have support for HP-SWITCHING-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Hpe Switch Memory Utilizationhpe_switch_MemoryUtilizationHpe Switch Memory Utilization%Monitors the HPE switch memory utilization.[HP-SWITCHING-MIB :: agentSwitchCpuProcessMemFree : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.1.0, agentSwitchCpuProcessMemAvailable : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.2.0]
Hpe Switch CPU Process Utilizationhpe_switch_CpuProcessPercentageUtilizationHpe Switch Cpu Process Utilization%Monitors the CPU utilization per process in Percentage.[HP-SWITCHING-MIB :: agentSwitchCpuProcessPercentageUtilization : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.8.1.3]
Hpe Switch Overall CPU Process Utilizationhpe_switch_CpuProcessTotalUtilizationHpe Switch Overall CPU Process Utilization%Monitors the overall CPU process utilization in percentage.[HP-SWITCHING-MIB :: agentSwitchCpuProcessTotalUtilization : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.9.0]

HPE Switch - Hardware

Description

Monitors the Hpe Switch Hardware Statistics like Speed and Status of the Fan, Temperature value and State of Temperature Sensor, Temperature Unit State, Status of Power Supply.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesFanItemState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.6.1.3, boxServicesFanSpeed : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.6.1.4, boxServicesPowSupplyItemState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.7.1.3, boxServicesTempSensorState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.8.1.4, boxServicesTempSensorTemperature : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.8.1.5, boxServicesTempUnitState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.15.1.2].Validated on HPE OfficeConnect Switch 1920S 24G 2SFP JL381A, PD.01.05, sysObjectId: 1.3.6.1.4.1.11.2.3.7.11.184. Note: This HPE OfficeConnect Switch supports only power supply component.

Prerequisites

Device must have support for HP-BOXSERVICES-PRIVATE-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Hpe Switch - Fanhpe_switch_FanStateHpe Switch Fan StateMonitors the status of fan.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesFanItemState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.6.1.3].Possible values are notpresent(1), operational(2), failed(3), powering(4), nopower(5), notpowering(6), incompatible(7).
hpe_switch_FanSpeedHpe Switch Fan SpeedrpmMonitors the speed of fan.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesFanSpeed : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.6.1.4]
Hpe Switch - Power Supplyhpe_switch_PowerSupplyStateHpe Switch Power Supply StateMonitors the status of power supply.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesPowSupplyItemState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.7.1.3].Possible values are notpresent(1), operational(2), failed(3), powering(4), nopower(5), notpowering(6), incompatible(7).
Hpe Switch - Temperature Sensorhpe_switch_TempSensorStateHpe Switch Temp Sensor StateMonitors the state of temperature sensor.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesTempSensorState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.8.1.4].Possible values are low(0), normal(1), warning(2), critical(3), shutdown(4), notpresent(5), notoperational(6).
hpe_switch_TemperatureSensorValueHpe Switch Temperature Sensor ValueCelsiusMonitor the temperature value reported by sensor.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesTempSensorTemperature : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.8.1.5]
Hpe Switch - Temperature Unit Statehpe_switch_TempUnitStateHpe Switch Temp Unit StateMonitors the temperature state of the unit.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesTempUnitState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.15.1.2].Possible values are low(0), normal(1), warning(2), critical(3), shutdown(4), notpresent(5), notoperational(6).

HP-Unix System Performance

Description

It monitors HP-Unix System Performance parameters like CPU load,File System Used,File System Free,File System Utilization,Physical Memory Used,Physical Memory Free,Physical Memory Utilization and uptime.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HP-Unix CPU Loadhp.unix.sys.cpu.load.avg.5minCPU Load 5minIt monitors average number of jobs in the last 5 minutes.[computerSystemAvgJobs5 - 1.3.6.1.4.1.11.2.3.1.1.4.0]
HP-Unix File Systemhp.unix.file.system.usedFle System UsedBytesIt monitors the HP-Unix File System used space.[HP-UNIX::fileSystemDir - 1.3.6.1.4.1.11.2.3.1.2.2.1.10,fileSystemBsize - 1.3.6.1.4.1.11.2.3.1.2.2.1.7,fileSystemBlock - 1.3.6.1.4.1.11.2.3.1.2.2.1.4,fileSystemBfree - 1.3.6.1.4.1.11.2.3.1.2.2.1.5]
hp.unix.file.system.utilizationFle System Utilization%It monitors the HP-Unix File System utilization.[HP-UNIX::fileSystemDir - 1.3.6.1.4.1.11.2.3.1.2.2.1.10,fileSystemBsize - 1.3.6.1.4.1.11.2.3.1.2.2.1.7,fileSystemBlock - 1.3.6.1.4.1.11.2.3.1.2.2.1.4,fileSystemBfree - 1.3.6.1.4.1.11.2.3.1.2.2.1.5]
hp.unix.file.system.freeFile System FreeBytesIt monitors the HP-Unix File System free space.[HP-UNIX::fileSystemDir - 1.3.6.1.4.1.11.2.3.1.2.2.1.10,fileSystemBsize - 1.3.6.1.4.1.11.2.3.1.2.2.1.7,fileSystemBfree - 1.3.6.1.4.1.11.2.3.1.2.2.1.5]
HP-Unix Physical Memoryhp.unix.sys.memory.utilizationMemory Utilization%It monitors HP-Unix Physical memory utilization in %.[computerSystemFreeMemory - 1.3.6.1.4.1.11.2.3.1.1.7.0,computerSystemPhysMemory - 1.3.6.1.4.1.11.2.3.1.1.8.0]
hp.unix.sys.memory.usedMemory UsedMBIt monitors HP-Unix Physical Memory used.[computerSystemFreeMemory - 1.3.6.1.4.1.11.2.3.1.1.7.0,computerSystemPhysMemory - 1.3.6.1.4.1.11.2.3.1.1.8.0]
hp.unix.sys.memory.freeMemory FreeMBIt monitors HP-Unix Physical Memory free.[computerSystemFreeMemory - 1.3.6.1.4.1.11.2.3.1.1.7.0]
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

HPE Intelligent PDU (iPDU)

Description

Template to monitor HP Intelligent Modular PDU . Validated on AF520A(HP INTELLIGENT MOD PDU 24A NA/JPN). Firmware version 2.0.51.12

Prerequisites

The device should have support for CPQPOWER-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HPE Intelligent PDU (iPDU)hpe.ipdu.total.power.wattsTotal Power (Watts)WIt monitors the total power for the whole iPDU in Watts.[CPQPOWER-MIB::mpduTotalPowerWatt:1.3.6.1.4.1.232.165.5.1.2.1.38].
hpe.ipdu.total.power.vaTotal Power (VA)It monitors the total power for the whole iPDU in VA.[CPQPOWER-MIB::mpduTotalPowerVA:1.3.6.1.4.1.232.165.5.1.2.1.39].
hpe.ipdu.total.percent.loadTotal Percent Load%It monitors the whole iPDU's load in percent of rated capacity.[CPQPOWER-MIB::mpduTotalPercentLoad:1.3.6.1.4.1.232.165.5.1.2.1.40].
hpe.ipdu.output.statusOutput StatusIt monitors the overall status of the device.Possible values are on : 1,off : 0,problem : 2.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputStatus:1.3.6.1.4.1.232.165.5.2.1.1.2].
hpe.ipdu.output.percent.loadOutput Percent Load%It monitors the PDU's each output load in percent of rated capacity.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputPercentLoad:1.3.6.1.4.1.232.165.5.2.1.1.5].
hpe.ipdu.output.voltageOutput VoltagevIt monitors the measured output voltage from the PDU meters in volts.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputVoltage:1.3.6.1.4.1.232.165.5.2.1.1.6].
hpe.ipdu.output.currentOutput CurrentampsIt monitors the measured output current from the PDU meters in amps.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputCurrent:1.3.6.1.4.1.232.165.5.2.1.1.7].
hpe.ipdu.output.power.vaOutput Power (VA)It monitors the total VA load (VI) measured on the PDU in VA.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputPowerVA:1.3.6.1.4.1.232.165.5.2.1.1.8].
hpe.ipdu.output.power.wattsOutput Power (Watts)WIt monitors the total power load measured on the PDU in Watts.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputPowerWatt:1.3.6.1.4.1.232.165.5.2.1.1.9].
hpe.ipdu.smart.ext.bar.outlet.voltageSmart Ext Bar Outlet VoltagevIt monitors the Smart Ext Bar voltage in volts.Component or instance is represented as Index of PDU,output index of PDU and Smart Ext Bar outlet index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduSmExtBarOutletVoltage:1.3.6.1.4.1.232.165.5.4.1.1.5].
hpe.ipdu.smart.ext.bar.outlet.currentSmart Ext Bar Outlet CurrentampsIt monitors the Smart Ext Bar current draw in Amps.Component or instance is represented as Index of PDU,output index of PDU and Smart Ext Bar outlet index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduSmExtBarOutletCurrent:1.3.6.1.4.1.232.165.5.4.1.1.6].
hpe.ipdu.smart.ext.bar.outlet.power.wattsSmart Ext Bar Outlet Power (Watts)WIt monitors the Smart Ext Bar's Power measured in Watts.Component or instance is represented as Index of PDU,output index of PDU and Smart Ext Bar outlet index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduSmExtBarOutletPowerWatt:1.3.6.1.4.1.232.165.5.4.1.1.7].
hpe.ipdu.smart.ext.bar.outlet.statusSmart Ext Bar Outlet StatusIt monitors the overall status of the Smart Extension Bar's outlet.Possible Values are on : 1,off : 0,problem : 2.Component or instance is represented as Index of PDU,output index of PDU and Smart Ext Bar outlet index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduSmExtBarOutletStatus:1.3.6.1.4.1.232.165.5.4.1.1.2].
hpe.ipdu.device.statusDevice StatusIt monitors the overall status of the device.Possible values are on : 1,off : 0,problem : 2.If component name not detected then component will be in format of : Index of PDU and device index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduDeviceStatus:1.3.6.1.4.1.232.165.5.3.1.1.2].

HPE PDU3

Description

Template to monitor HPE PDU3 parameters like Status,Input Frequency (Hz),Input Frequency Status,Input Power (VA),Input Power (Watts),Input Phase Voltage,Input Phase Voltage Status,Input Phase Current,Input Phase Current Status,Input Phase Power (VA),Input Phase Power (Watts),Group Voltage,Group Voltage Status,Group Current,Group Current Status,Group Current Percent Load,Group Power (VA),Group Power (Watts),Temperature,Temperature Status,Humidity,Humidity Status,Outlet Current,Outlet Active Power Status,Outlet Current Percent Load,Outlet Power (VA),Outlet Power (Watts). Enterprise OID : 1.3.6.1.4.1.232.165.11. CPQPOWER-MIB

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
HPE PDU3 - Grouphpe.pdu3.group.currentGroup CurrentIt monitors group current measurement value.[CPQPOWER-MIB::pdu3GroupCurrent:1.3.6.1.4.1.232.165.11.3.1.1.12].
hpe.pdu3.group.power.vaGroup Power (VA)It monitors the group VA value.[CPQPOWER-MIB::pdu3GroupPowerVA:1.3.6.1.4.1.232.165.11.3.1.1.19].
hpe.pdu3.group.current.percent.loadGroup Current Percent Load%It monitors the current percent load,based on the rated current capacity.[CPQPOWER-MIB::pdu3GroupCurrentPercentLoad:1.3.6.1.4.1.232.165.11.3.1.1.18].
hpe.pdu3.group.power.wattsGroup Power (Watts)WIt monitors the group power value in watts.[CPQPOWER-MIB::pdu3GroupPowerWatts:1.3.6.1.4.1.232.165.11.3.1.1.20].
hpe.pdu3.group.voltage.statusGroup Voltage StatusIt monitors status of the measured group voltage relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.[CPQPOWER-MIB::pdu3GroupVoltageThStatus:1.3.6.1.4.1.232.165.11.3.1.1.6].
hpe.pdu3.group.current.statusGroup Current StatusIt monitors status of the measured group current relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.[CPQPOWER-MIB::pdu3GroupCurrentThStatus:1.3.6.1.4.1.232.165.11.3.1.1.13].
hpe.pdu3.group.voltageGroup VoltagevIt monitors the PDU3 Group Voltage.[CPQPOWER-MIB::pdu3GroupVoltage:1.3.6.1.4.1.232.165.11.3.1.1.5].
HPE PDU3 - Humidityhpe.pdu3.humidityHumidity (%RH)It monitors the PDU3 humidity.[CPQPOWER-MIB::pdu3HumidityValue:1.3.6.1.4.1.232.165.11.4.3.1.4].
hpe.pdu3.humidity.statusHumidity StatusIt monitors the status of the measured humidity relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical [CPQPOWER-MIB::pdu3HumidityThStatus:1.3.6.1.4.1.232.165.11.4.3.1.5].
HPE PDU3 - Inputhpe.pdu3.input.frequencyInput Frequency (Hz)It monitors the measured input frequency from the PDU meters in Hz.[CPQPOWER-MIB::pdu3InputFrequency1.3.6.1.4.1.232.165.11.2.1.1.2].
hpe.pdu3.input.power.wattsInput Power (Watts)WIt monitors the total input Watts of all phases.[CPQPOWER-MIB::pdu3InputPowerWatts:1.3.6.1.4.1.232.165.11.2.1.1.5].
hpe.pdu3.input.frequency.statusInput Frequency StatusIt monitors the status of the measured input frequency relative to the nominal frequency and the admitted tolerance.Possible values are 0:unknown,1: good,2: outOfRange.[CPQPOWER-MIB::pdu3InputFrequencyStatus:1.3.6.1.4.1.232.165.11.2.1.1.3].
hpe.pdu3.input.power.vaInput Power (VA)It monitors the total input VA of all phases.[CPQPOWER-MIB::pdu3InputPowerVA:1.3.6.1.4.1.232.165.11.2.1.1.4].
HPE PDU3 - Input Phasehpe.pdu3.input.phase.power.wattsPDU3 Input Phase Power (Watts)WIt monitors the input Watts value.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhasePowerWatts:1.3.6.1.4.1.232.165.11.2.2.1.20].
hpe.pdu3.input.phase.current.statusInput Phase Current StatusIt monitors the status of the measured input current relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhaseCurrentThStatus:1.3.6.1.4.1.232.165.11.2.2.1.12].
hpe.pdu3.input.phase.voltageInput Phase VoltageIt monitors the input voltage measurement value.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhaseVoltage:1.3.6.1.4.1.232.165.11.2.2.1.3].
hpe.pdu3.input.phase.voltage.statusInput Phase Voltage StatusIt monitors the status of the measured input voltage relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhaseVoltageThStatus:1.3.6.1.4.1.232.165.11.2.2.1.4].
hpe.pdu3.input.phase.power.vaInput Phase Power (VA)It monitors the input VA value.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhasePowerVA:1.3.6.1.4.1.232.165.11.2.2.1.19].
hpe.pdu3.input.phase.currentInput Phase CurrentIt monitors the input current measurement value.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhaseCurrent:1.3.6.1.4.1.232.165.11.2.2.1.11].
HPE PDU3 - Outlethpe.pdu3.outlet.active.power.statusOutlet Active Power StatusIt monitors the status of the measured outlet active power relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.[CPQPOWER-MIB::pdu3OutletActivePowerThStatus:1.3.6.1.4.1.232.165.11.5.1.1.6].
hpe.pdu3.outlet.power.wattsOutlet Active Power StatusIt monitors the status of the measured outlet active power relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.[CPQPOWER-MIB::pdu3OutletActivePowerThStatus:1.3.6.1.4.1.232.165.11.5.1.1.6].
hpe.pdu3.outlet.current.percent.loadOutlet Current Percent Load%It monitors the current percent load,based on the rated current capacity.[CPQPOWER-MIB::pdu3OutletCurrentPercentLoad:1.3.6.1.4.1.232.165.11.5.1.1.11].
hpe.pdu3.outlet.currentOutlet CurrentampsIt monitors the outlet current measurement value.[CPQPOWER-MIB::pdu3OutletCurrent:1.3.6.1.4.1.232.165.11.5.1.1.5].
hpe.pdu3.outlet.power.vaOutlet Power (VA)It monitors the outlet power VA value.[CPQPOWER-MIB::pdu3OutletVA:1.3.6.1.4.1.232.165.11.5.1.1.12].
HPE PDU3 - Statushpe.pdu3.statusPDU3 StatusIt monitors the overall status of the device. Possible values are 0:unknown,1: other,2: ok,3: degraded,4: failed.[CPQPOWER-MIB::pdu3Status:1.3.6.1.4.1.232.165.11.1.2.1.9,pdu3SerialNumber:1.3.6.1.4.1.232.165.11.1.2.1.8].
HPE PDU3 - Temperaturehpe.pdu3.temperatureTemperatureIt monitors the PDU3 Temperature.[CPQPOWER-MIB::pdu3TemperatureValue:1.3.6.1.4.1.232.165.11.4.2.1.4].
hpe.pdu3.temperature.statusTemperature StatusIt monitors the status of the measured temperature relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.[CPQPOWER-MIB::pdu3TemperatureThStatus:1.3.6.1.4.1.232.165.11.4.2.1.5].