HPE - HTTP Management Device Health
Description
Template to monitor HP HTTP Management Device Health.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP - HTTP Management Device Health | hp.http.mgmt.device.health | HTTP Management Device Health | It monitors the overall health of the device.Possible values are unknown(1),unused(2),ok(3),warning(4),critical(5),nonrecoverable(6) [SEMI-MIB::hpHttpMgDeviceHealth:1.3.6.1.4.1.11.2.36.1.1.5.1.1.3]. |
HPE Blade System Switch monitors
Description
This template is applicable on HP switches meant for blade system. For eg GbE2c Ethernet Blade switch. Monitors CPU Utilization and VLAN status.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP Blade System Switch CPU Utilization | system.cpu.utilization | HP Blade System Switch CPU Utilization | % | Monitors the utilization (in percent) of MP CPU over 64 seconds.[OID: 1.3.6.1.4.1.11.2.3.7.11.33.4.2.1.2.2.3.0] |
HP Blade System Switch VLAN Status | vlan.status | VLAN Status | Monitors the VLAN status information. Possible values are 2- Enabled,3- Disabled.[OIDs: 1.3.6.1.4.1.11.2.3.7.11.33.4.2.2.3.8.1.1.2,1.3.6.1.4.1.11.2.3.7.11.33.4.2.2.3.8.1.1.3] | |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
HPE Compaq - Host Performance
Description
Template to monitor HPE Compaq Host Performance parameters like cpu utilization,file system space total,file system space used,file system status,physical memory size,physical memory free,physical memory utilization.[CPQHOST-MIB :: cpqHoCpuUtilFiveMin : 1.3.6.1.4.1.232.11.2.3.1.1.3,cpqHoFileSysSpaceTotal : 1.3.6.1.4.1.232.11.2.4.1.1.3,cpqHoFileSysSpaceUsed : 1.3.6.1.4.1.232.11.2.4.1.1.4,cpqHoFileSysStatus : 1.3.6.1.4.1.232.11.2.4.1.1.8,cpqHoPhysicalMemorySize : 1.3.6.1.4.1.232.11.2.13.1.0,cpqHoPhysicalMemoryFree : 1.3.6.1.4.1.232.11.2.13.2.0]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Compaq Cpq Host - Cpu Utilization | compaq_cpqhost_CpqHoCpuUtilFiveMin | Compaq Cpq Host Cpu Utilization | % | Monitors the Compaq cpq Host cpu utilization.[CPQHOST-MIB :: cpqHoCpuUtilFiveMin : 1.3.6.1.4.1.232.11.2.3.1.1.3] |
Compaq Cpq Host - File System | compaq_cpqhost_CpqHoFileSysSpaceUtilization | Compaq Cpq Host File Sys Space Utilization | % | Monitors the Compaq Cpq Host File Sys Space Utilization. |
compaq_cpqhost_CpqHoFileSysStatus | Compaq Cpq Host File Sys Status | Monitors the threshold status.[CPQHOST-MIB :: cpqHoFileSysStatus : 1.3.6.1.4.1.232.11.2.4.1.1.8] | ||
compaq_cpqhost_CpqHoFileSysSpaceTotal | Compaq Cpq Host File Sys Space Total | MB | Monitors the file system size in megabytes.[CPQHOST-MIB :: cpqHoFileSysSpaceTotal : 1.3.6.1.4.1.232.11.2.4.1.1.3] | |
compaq_cpqhost_CpqHoFileSysSpaceUsed | Compaq Cpq Host File Sys Space Used | MB | Monitors the compaq cpq host file sys space used.[CPQHOST-MIB :: cpqHoFileSysSpaceUsed : 1.3.6.1.4.1.232.11.2.4.1.1.4] | |
compaq_cpqhost_CpqHoPhysicalMemoryUtilization | Compaq Cpq Host Physical Memory Utilization | % | Monitors the Compaq Cpq Host Physical Memory Utilization | |
compaq_cpqhost_CpqHoPhysicalMemoryFree | Compaq Cpq Host Physical Memory Free | MB | Monitors the Compaq Cpq Host Physical Memory Free in megabytes.[CPQHOST-MIB :: cpqHoPhysicalMemoryFree :: 1.3.6.1.4.1.232.11.2.13.2.0] | |
compaq_cpqhost_CpqHoPhysicalMemorySize | Compaq Cpq Host Physical Memory Size | MB | Monitors the file system size in megabytes.[CPQHOST-MIB :: cpqHoPhysicalMemorySize : 1.3.6.1.4.1.232.11.2.13.1.0] |
HPE Comware
Description
Template for HP Comware switch/router. Monitors entity CPU usage,memory usage,temperature,uptime,error status and alarm status. Validated on HP Comware Platform Software,Software Version 5.20.99 Release 2222P08 HP A5500-24G EI Switch with 2 Interface Slots. SNMP SysObjId=1.3.6.1.4.1.25506.11.1.24.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP Comware Entity Alarm Light | hp.comware.entity.alarm.light | HP Comware Entity Alarm Light | Provides the Alarm status of this entity,It does not include the severity of alarms raised on child components. In this condition,there will be a alarm light on the entity,the object should have the same status with it.[OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.5] | |
HP Comware Entity CPU Usage - Rule Based | hp.comware.entity.cpu.usage | HP Comware Entity CPU Usage | % | Provides the HP Comware CPU usage. Generally,the CPU usage will calculate the overall CPU usage on the entity,and it is not sensible with the number of CPU on the entity.[OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.6] |
HP Comware Entity Error Status | hp.comware.entity.error.status | HP Comware Entity Error Status | It Indicate the error state of this entity object.[OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.19] | |
HP Comware Entity Temperature - Rule Based | hp.comware.entity.temperature | HP Comware Entity Temperature | C | Provides the HP Comware temperature details for this Entity.[OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.12] |
HP Comware Memory Usage - Rule Based | hp.comware.entity.memoryusage | HP Comware Entity Memory Usage | % | Provides the details about the memory usage if this Entity,provides the usage vlues in percentage (%).[OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.8] |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
HPE iLO Monitors
Description
Template for HP ILO (Integrated Lights - Out). Monitors the battery,fan,temperature,fault tolerance power supply status. Also monitor controller battery status,controller interface status,etc,. Tested on HP ILO 4 AOS server.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
CPQ DA Accelerator | hp.ilo.cpq.da.accelerator.error.code | CPQ DA Accelerator Error Code | Monitors the drive array accelerator board error code. Used to determine the status of the write cache operations. The status can be: 1- Other: Indicates that the instrument agent does not recognize the error code. You may need to update your software,2-Invalid: Indicates that write cache operations are currently configured and enabled for at least one logical drive. No write cache errors have occurred,3- Bad Configuration: Indicates that write cache operations are temporarily disabled. The Array Accelerator board was configured for a different controller. This error could be caused if boards were switched from one system to another. Rerun the configuration utility and ensure that the board has been properly configured for this system. Note: If data from another system was stored on the board,running configuration utility will cause the data to be lost,4- Low Battery Power: Indicates that write cache operations are temporarily disabled due to insufficient battery power. Please view the Battery Status object instance for more information,5- Disable Command Issued: Indicates that write cache operations are temporarily disabled. The device driver issues this command when the server is taken down. This condition should not exist when the system regains power,6- No Resources Available: Indicates that write cache operations are temporarily disabled. The controller does not have sufficient resources to perform write cache operations. For example,when a replaced drive is being rebuilt,there will not be sufficient resources. Once the operation that requires the resources has completed,this condition will clear and write cache operations will resume,7- Board Not Connected: Indicates that write cache operations are temporarily disabled. The Array Accelerator board has been configured but is not currently attached to the controller. Check the alignment of the board and connections,8- Bad Mirror Data: Indicates that write cache operations have been permanently disabled. The Array Accelerator board stores mirrored copies of all data. If data exists on the board when the system is first powered up,the board performs a data compare test between the mirrored copies. If the data does not match,an error has occurred. Data may have been lost. Your board may need servicing,9- Read Failure: Indicates that write cache operations have been permanently disabled. The Array Accelerator board stores mirror copies of all data. While reading the data from the board,memory parity errors have occurred. Both copies were corrupted and cannot be retrieved. Data has been lost,and you should service the board,10- Write Failure: Indicates that write cache operations have been permanently disabled. This error occurs when an unsuccessful attempt was made to write data to the Array Accelerator board. Data could not be written to write cache memory in duplicate due to the detection of parity errors. This error does not indicate data loss. You should service the Array Accelerator board,11- Config Command: Indicates that write cache operations have been permanently disabled. The configuration of the logical drives has changed. You need to reconfigure the Array Accelerator board,12- Expand in Progress: Indicates that cache operations are temporarily disabled due to an expand of a logical drive. When the expand operation completes,the accelerator will be enabled,13- Snapshot In Progress: Indicates that cache operations are temporarily disabled due to a snapshot operation that is queued up or in progress. When the snapshot operation completes,the accelerator will be enabled,14- Redundant Low Battery: Indicates that cache operations are temporarily disabled. The redundant controller has insufficient cache battery power,15- Redundant Size Mismatch: Indicates that cache operations are temporarily disabled. The cache sizes on the redundant controllers do not match,16- Redundant Cache Failure: Indicates that cache operations are temporarily disabled. The cache on the redundant controller has failed,17- Excessive ECC Errors: Indicates that write cache operations have been permanently disabled. The number of cache lines experiencing excessive ECC errors has reached a preset limit,18- RAID ADG Enabler Module Missing: Indicates that write cache operations have been temperarily disabled. A RAID ADG logical drive is configured but the RAID ADG Enabler Module is broken or missing,19- Power On Self Test (Post) ECC Errors: Indicates that write cache operations have been permanently disabled. The cache has been disabled due to a large number of ECC errors detected while testing the cache during Power On Self Test (Post),20- Battery Hot Removed: Indicates that write cache operations have been permanently disabled. The cache has been disabled because a battery has been hot removed.[OIDs: 1.3.6.1.4.1.232.3.2.2.2.1.1,1.3.6.1.4.1.232.3.2.2.2.1.5] | |
hp.ilo.cpq.da.accelerator.battery | CPQ DA Accelerator Battery Status | Monitors the array accelerator board battery status. Provides the status of each battery pack on the board. The batteries can only recharge when the system has power applied. Possible values are 1- Other:Indicates that the instrument agent does not recognize battery status. You may need to update your software,2- Ok: Indicates that a particular battery pack is fully charged,3- Charging: The battery power is less than 75%. The Drive Array Controller is attempting to recharge the battery. A battery can take as long as 36 hours to fully recharge.After 36 hours,if the battery has not recharged,it is considered failed,4- Failed: The battery pack is below the sufficient voltage level and has not recharged in 36 hours. Your Array Accelerator board needs to be serviced,5- Degraded:The battery is still operating,however,one of the batteries in the pack has failed to recharge properly. Your Array Accelerator board should be serviced as soon as possible,6- NotPresent: There are no batteries associated with this controller.[OIDs: 1.3.6.1.4.1.232.3.2.2.2.1.1,1.3.6.1.4.1.232.3.2.2.2.1.6] | ||
hp.ilo.cpq.da.accelerator.condition | CPQ DA Accelerator Overall Condition | Monitors the overall condition of drive array accelerator. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.2.2.1.1,1.3.6.1.4.1.232.3.2.2.2.1.9] | ||
CPQ DA Array Controller Status | arraycontroller.status | CPQ DA Array Controller Condition | Monitors the overall condition of this controller,and any associated logical drives,physical drives,and array accelerators. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.2.1.1.1,1.3.6.1.4.1.232.3.2.2.1.1.6] | |
CPQ DA Condition | hp.ilo.cpq.da.condition | CPQ Drive Array Overall Status | Monitors the overall condition (status) of the driver array. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.3.1.3.0] | |
CPQ DA Logical Drive | logical.disk.status | CPQ DA Logical Drive Condition | Monitors the overall condition of this logical drive and any associated physical drives. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.3.1.1.1,1.3.6.1.4.1.232.3.2.3.1.1.2,1.3.6.1.4.1.232.3.2.3.1.1.11] | |
CPQ DA Physical Drive | cpq.da.physical.drive.condition | CPQ DA Physical Drive Condition | Monitors the overall condition of this physical drive. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.5.1.1.1,1.3.6.1.4.1.232.3.2.5.1.1.2,1.3.6.1.4.1.232.3.2.5.1.1.37] | |
cpq.da.physical.drive.smartstatus | CPQ DA Physical Drive SMART Status | Monitors the physical drive S.M.A.R.T status. Possible values are 1- other: The agent is unable to determine if the status of S.M.A.R.T predictive failure monitoring for this drive,2- ok: Indicates the drive is functioning properly,3- replaceDrive: Indicates that the drive has a S.M.A.R.T predictive failure error and should be replaced.[OIDs: 1.3.6.1.4.1.232.3.2.5.1.1.1,1.3.6.1.4.1.232.3.2.5.1.1.2,1.3.6.1.4.1.232.3.2.5.1.1.57] | ||
CPQ HE Environment | cpu.fan.thermal.health | CPQ CPU Fan Thermal Health | Provides the status of the processor fan(s) in the system. This value will be one of the following:- other(1): Fan status detection is not supported by this system or driver,ok(2): All fans are operating properly,failed(4): A fan is not operating properly. System will be shutdown if the failed(4) condition occurs.[OID: 1.3.6.1.4.1.232.6.2.6.5.0] | |
temperature.sensors.health | CPQ System Temperature Sensors Status | Provides the status of the system's temperature sensors. This value will be one of the following:- other(1): Temp sensing is not supported by this system or driver,ok(2): All temp sensors are within normal operating range,degraded(3): A temp sensor is outside of normal operating range,failed(4): A temp sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results.[OIDs: 1.3.6.1.4.1.232.6.2.6.3.0] | ||
system.fans.health | CPQ System Fans Status | The status of the fan(s) in the system. This value will be one of the following:- other(1): Fan status detection is not supported by this system or driver,ok(2): All fans are operating properly,degraded(3): A non-required fan is not operating properly,failed(4): A required fan is not operating properly.[OID: 1.3.6.1.4.1.232.6.2.6.4.0] | ||
over.server.thermal.health | CPQ Thermal Environment Overall Health | Specifies the overall condition of the system's thermal environment.[OID: 1.3.6.1.4.1.232.6.2.6.1.0] | ||
hp.ilo.cpq.he.condition | CPQ Server Health System Overall Status | Monitors the overall status of the server health system. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.1.3.0] | ||
hp.ilo.cpq.he.asr.condition | CPQ Server Health ASR Overall Condition | Monitors the overall condition of the Automatic Server Recovery (ASR) feature. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.5.17.0] | ||
hp.ilo.cpq.he.eventlog.condition | CPQ HE Event Log Condition | Monitors the overall condition of the integrated management log feature. Possible values are 1- Other,2- OK,3- degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.11.2.0] | ||
hp.ilo.cpq.he.resillent.memory.condition | CPQ HE Resilient Memory Condition | Monitors the current condition of the Advanced Memory Protection subsystem. Possible values are 1- other: The system does not support fault tolerant memory or the state cannot be determined by the Management Agent,2- ok: This system is operating normally,3- degraded: The system is running in a degraded state because the Advanced Memory Protection subsystem has been engaged.[OID: 1.3.6.1.4.1.232.6.2.14.4.0] | ||
cpq.ss.condition | CPQ Storage System Overall Condition | Monitors the overall condition (status) of the storage system. Possible values are 1- Other,2- OK,3- Degraded.[OID: 1.3.6.1.4.1.232.8.1.3.0] | ||
cpq.he.fault.tolerant.powersupply.condition | CPQ HE Fault Tolerant Power Supply Condition | Monitors the overall condition of the fault tolerant power supply sub-system. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.9.1.0] | ||
CPQ HE Fault Tolerant Fan Health | fault.tolerant.fan.status | CPQ HE Fault Tolerent Fan Health | Provides the condition of the fan. Possible values are 1- other: Fan status detection is not supported by this system or driver,2- ok: The fan is operating properly,3- degraded: A redundant fan is not operating properly,4- failed: A non-redundant fan is not operating properly.[OIDs: 1.3.6.1.4.1.232.6.2.6.7.1.1,1.3.6.1.4.1.232.6.2.6.7.1.2,1.3.6.1.4.1.232.6.2.6.7.1.9] | |
CPQ HE Power Supply Health | fault.tolerant.power.supply.status | CPQ Fault Tolerant Power Supply Health | Monitors the condition of the power supply. Possible values are 1- other: The status could not be determined or not present,2- ok: The power supply is operating normally,3- degraded: Power supply is outside of normal operating range,4- failed: power supply component detects a condition that could permanently damage the system.[OIDs: 1.3.6.1.4.1.232.6.2.9.3.1.4,1.3.6.1.4.1.232.6.2.9.3.1.1,1.3.6.1.4.1.232.6.2.9.3.1.2] | |
CPQ HE Resilient Memory 2 Board Condition | hp.ilo.cpq.he.resillentmemory.board.condition | CPQ HE Resilient Memory 2 Board Condition | Monitors the current status of the Advanced Memory Protection memory board or cartridge or riser. Possible values are 1- other: The condition of this memory board or cartridge or riser could not be determined,2- ok: The memory board or cartridge or riser is operating normally,3- degraded: The memory board or cartridge or riser is in an error state. Check for correct memory installation and that the board has been inserted properly.[OIDs: 1.3.6.1.4.1.232.6.2.14.12.1.1,1.3.6.1.4.1.232.6.2.14.12.1.11] | |
CPQ HE Resilient Memory 2 Module Condition | cpq.he.resilient.memory.2.module.condition | CPQ HE Resilient Memory 2 Module Condition | Monitors the current status of the correctable memory errors for this memory module. Possible values are 1- other: ECC is not supported on this memory module or the condition could not be determined,2- ok: The memory module is operating normally,3- degraded: The memory module is correctable error count has exceeded threshold or a configuration error has been detected,4- degradedModuleIndexUnknown: The correctable error count has exceeded threshold. The module number not available.[OIDs: 1.3.6.1.4.1.232.6.2.14.13.1.1,1.3.6.1.4.1.232.6.2.14.13.1.20] | |
CPQ HE Temperature Sensor Health | temperature.sensor.status | CPQ Temperature Sensor Health | Monitors the temperature sensor condition. Possible values are 1- other: Temperature could not be determined,2- ok: The temperature sensor is within normal operating range,3- degraded: The temperature sensor is outside of normal operating range,4- failed: The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results.[OIDs: 1.3.6.1.4.1.232.6.2.6.8.1.6,1.3.6.1.4.1.232.6.2.6.8.1.1,1.3.6.1.4.1.232.6.2.6.8.1.2] | |
CPQ Host CPU Utilization | cpu.usage | CPQ Host CPU Utilization | % | Monitors the The CPU utilization as a percentage of the theoretical maximum during the last five minutes. A value of -1 indicates that no CPU utilization information is available for this processor.[OID: 1.3.6.1.4.1.232.11.2.3.1.1.3,1.3.6.1.4.1.232.11.2.3.1.1.1] |
CPQ SE CPU Cache Status | cpq.se.cpu.cache.status | CPQ CPU Cache Status | Monitors the status of the cache unit. If the cache is optional and not installed,unknown(1) will be returned.[OIDs: 1.3.6.1.4.1.232.1.2.2.3.1.1,1.3.6.1.4.1.232.1.2.2.3.1.2,1.3.6.1.4.1.232.1.2.2.3.1.5] | |
CPQ SE CPU Status | cpu.health | CPQ CPU Status | The status of the processor. Possible values are 1- Unknown: The status of the CPU could not be determined,2- OK: The CPU is functioning normally,3- Degraded: The CPU is in a pre-failure warrantee state,4- Failed: The CPU is in a failed state,5- Disabled: The CPU has been disabled during power-on-self-test.[OIDs: 1.3.6.1.4.1.232.1.2.2.1.1.3,1.3.6.1.4.1.232.1.2.2.1.1.6] | |
CPQ SE Overall Condition | cpq.he.se.condition | CPQ Server Overall Condition | Monitors the overall condition of the server. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.1.1.3.0] | |
CPQ SI Condition | cpq.si.condition | CPQ Server Information Overall Condition | Monitors the overall status of the CPQ server information. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.2.1.3.0] | |
CPQ SM2 ILO | cpq.sm2.condition | CPQ SM2 Condition | Monitors the overall condition of the Remote Insight/ Integrated Lights-Out. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.9.1.3.0] | |
cpq.sm2.controller.battery.status | CPQ SM2 Controller Battery Status | Monitors the remote insight battery status. Possible values are 1- other: The Insight Agent is unable to determine if the battery needs replacement,2- batteryOk: The Remote Insight battery is OK,3- batteryFailed: The Remote Insight battery needs replacement,4- batteryDisconnected: The Remote Insight battery is disconnected.[OID: 1.3.6.1.4.1.232.9.2.2.5.0] | ||
cpq.sm2.controller.interface.status | CPQ SM2 Controller Interface Status | Monitors the Remote Insight/ Integrated Lights-Out Interface Status. Possible values are 1- other: The Insight Agent is unable to determine the status of the Remote Insight/ Integrated Lights-Out interface,2- ok: The Remote Insight/ Integrated Lights-Out firmware is responding to commands,3- notResponding: The Remote Insight/ Integrated Lights-Out firmware is not responding to commands.[OID: 1.3.6.1.4.1.232.9.2.2.17.0] | ||
CPQ SM2 NIC Condition | cpq.sm2.nic.condition | CPQ SM2 NIC Condition | Monitors the overall condition of the Remote Insight/ Integrated Lights-Out Network Interface Controller (NIC). Possible values are are 1- Other,2- OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.9.2.5.1.1.11,1.3.6.1.4.1.232.9.2.5.1.1.5] | |
CPQ SS Box | cpq.ss.box.fan.status | CPQ SS Box Fan Status | Monitors the current status of the fans in the drive box. Possible values are 1- other: Fan monitoring is not supported by this system or it is not supported by the driver,2- ok: All fans are working normally,3- failed: One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage,4- noFan: This unit does not support fan monitoring,5- degraded: At least one storage system fan has failed,but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced.[OIDs: 1.3.6.1.4.1.232.8.2.1.1.1,1.3.6.1.4.1.232.8.2.1.1.2,1.3.6.1.4.1.232.8.2.1.1.7] | |
cpq.ss.box.condition | CPQ SS Box Condition | Monitors the overall condition of the drive box. Possible values are 1- other: The agent does not recognize the status. You may need to upgrade your software,2- ok: The storage system is operating normally. No user action is required,3- degraded: The storage system is degraded. You need to check the temperature status or power supply status of this storage system. Additionally,if the side panel for the storage system is removed,the air flow changes could result in improper cooling of the drives and affect the temperature status,4- failed: The storage system has failed.[OIDs: 1.3.6.1.4.1.232.8.2.1.1.2,1.3.6.1.4.1.232.8.2.1.1.8] | ||
cpq.ss.box.temperature.status | CPQ SS Box Temperature Status | Monitors the temperature status of the drive system. Possible values are 1- other:Temperature monitoring is not supported by this systemor it is not supported by the driver,2- ok:The temperature is within normal operating range,3- degraded:The temperature is outside of normal operating range,4- failed:The temperature could permanently damage the system.The storage system will automatically shutdown if thiscondition is detected,5- noTemp:This unit does not support temperature monitoring.[OIDs: 1.3.6.1.4.1.232.8.2.1.1.2,1.3.6.1.4.1.232.8.2.1.1.9] | ||
cpq.ss.box.fault.tolerance.power.supply | CPQ SS Box Fault Tolerant Power Supply Status | Monitors the overall status of the fault tolerant power supply sub-system in a drive box. Possible values are 1- other: The power supply status cannot be determined,2- ok: There are no detected power supply failures,3- degraded: One of the power supply units in a fault tolerant power supply has failed,4- failed: No failure conditions can currently be determined,5- noFltTolPower: This unit does not support fault tolerant power supply monitoring.[OIDs: 1.3.6.1.4.1.232.8.2.1.1.2,1.3.6.1.4.1.232.8.2.1.1.11] |
HPE iLO Monitors - v2
Description
Template to monitor HPE hardware components through iLO (Integrated Lights - Out). Monitors the battery,fan,temperature,fault tolerance power supply status. Also monitor controller battery status,controller interface status,Drive array condition,Network Interface Card Status etc,. Tested on HPE Integrated Lights-Out 6 (iLO6) ProLiant DL380 Gen11. This template will works for both higher and lower versions of iLO6 but all the metrics may or may not work for all iLO versions as functionality differs between different iLO versions.
Prerequisites
Device must have support for CPQHLTH-MIB,CPQSM2-MIB,CPQSINFO-MIB,CPQSTDEQ-MIB,CPQIDA-MIB and CPQNIC-MIB.
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HPE iLO CPQ DA Array Controller Status | hpe_ilo_drivearray_ControllerBoardCondition | HPE iLO Drive Array Controller Board Condition | Monitors the Array Controller Board Condition.[CPQIDA-MIB :: cpqDaCntlrBoardCondition : 1.3.6.1.4.1.232.3.2.2.1.1.12] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | |
hpe_ilo_drivearray_ControllerBoardStatus | HPE iLO Drive Array Controller Board Status | Monitors the Array Controller Board Status.[CPQIDA-MIB :: cpqDaCntlrBoardStatus : 1.3.6.1.4.1.232.3.2.2.1.1.10] Possible values are : 1 : other,2 : ok,3: generalFailure,4 : cableProblem,5 : poweredOff,6 : cacheModuleMissing,7 : degraded. | ||
hpe_ilo_drivearray_ControllerEncryptCspNvramStatus | HPE iLO Drive Array Controller Encrypt Csp Nvram Status | Monitors the Array Controller Encryption Critical Security Parameter NVRAM Status.[CPQIDA-MIB :: cpqDaCntlrEncryptCspNvramStatus : 1.3.6.1.4.1.232.3.2.2.1.1.36] Possible values are : 1 : other,2 : ok,3 : detectionFailed. | ||
hpe_ilo_drivearray_ControllerPartnerBoardStatus | HPE iLO Drive Array Controller Partner Board Status | Monitors the Array Controller Partner Board Status.[CPQIDA-MIB :: cpqDaCntlrPartnerBoardStatus : 1.3.6.1.4.1.232.3.2.2.1.1.11] Possible values are : 1 : other,2 : ok,3: generalFailure,4 : cableProblem,5 : poweredOff. | ||
hpe_ilo_drivearray_ControllerAccessModuleStatus | HPE iLO Drive Array Controller Access Module Status | Monitors the Array Controller RAID ADG Enabler Module Status.[CPQIDA-MIB :: cpqDaCntlrAccessModuleStatus : 1.3.6.1.4.1.232.3.2.2.1.1.18] Possible values are : 1 : other,2 : notSupported,3: notPresent,4 : badSignature,5 : badChecksum,6 : fullyFunctional,7 : upgradeFirmware. | ||
hpe_ilo_drivearray_ControllerPartnerBoardCondition | HPE iLO Drive Array Controller Partner Board Condition | Monitors the Array Controller Partner Board Condition.[CPQIDA-MIB :: cpqDaCntlrPartnerBoardCondition : 1.3.6.1.4.1.232.3.2.2.1.1.13] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_drivearray_ControllerCurrentTemperature | HPE iLO Drive Array Controller Current Temperature | Celsius | Monitors the Array Controller Current Temperature.[CPQIDA-MIB :: cpqDaCntlrCurrentTemp : 1.3.6.1.4.1.232.3.2.2.1.1.32] | |
hpe_ilo_drivearray_ControllerCondition | HPE iLO Drive Array Controller Condition | Monitors the condition of the device. This value represents the overall condition of this controller,and any associated logical drives,physical drives,and cache modules.[CPQIDA-MIB :: cpqDaCntlrCondition 1.3.6.1.4.1.232.3.2.2.1.1.6] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_drivearray_ControllerRedundancyError | HPE iLO Drive Array Controller Redundancy Error | Monitors the Array Controller Redundancy Error.[CPQIDA-MIB :: cpqDaCntlrRedundancyError : 1.3.6.1.4.1.232.3.2.2.1.1.17] Possible values are : 1 : other,2 : noFailure,3: noRedundantController,4 : differentHardware,5 : noLink,6 : differentFirmware,7 : differentCache,8 : otherCacheFailure,9 : noDrives,10 : otherNoDrives,11 : unsupportedDrives,12 : expandInProgress. | ||
HPE iLO CPQ DA Condition | hpe_ilo_drivearray_MibCondition | HPE iLO Drive Array Mib Condition | Monitors the overall condition (status) of the drive array.[CPQIDA-MIB :: cpqDaMibCondition : 1.3.6.1.4.1.232.3.1.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | |
HPE iLO CPQ DA Logical Drive | hpe_ilo_drivearray_LogicalDriveSize | HPE iLO Drive Array Logical Drive Size | MB | Monitors the Logical Drive Size.[CPQIDA-MIB :: cpqDaLogDrvSize : 1.3.6.1.4.1.232.3.2.3.1.1.9] |
hpe_ilo_drivearray_LogicalDriveStatus | HPE iLO Drive Array Logical Drive Status | Monitors the Logical Drive Status.[CPQIDA-MIB :: cpqDaLogDrvStatus : 1.3.6.1.4.1.232.3.2.3.1.1.4] Possible values are : 1 : other,2 : ok,3 : failed,4 : unconfigured,5 : recovering,6 : readyForRebuild,7 : rebuilding,8 : wrongDrive,9 : badConnect,10 : overheating,11 : shutdown,12 : expanding,13 : notAvailable,14 : queuedForExpansion,15 : multipathAccessDegraded,16 : erasing,17: predictiveSpareRebuildReady,18 : rapidParityInitInProgress,19 : rapidParityInitPending,20 : noAccessEncryptedNoCntlrKey,21 : unencryptedToEncryptedInProgress,22 : newLogDrvKeyRekeyInProgress,23 : noAccessEncryptedCntlrEncryptnNotEnbld,24 : unencryptedToEncryptedNotStarted,25 : newLogDrvKeyRekeyRequestReceived,26 : unsupported,27 : offline,28 : sedQualInProgrss,29 : sedQualFailed. | ||
hpe_ilo_drivearray_LogicalDriveCondition | HPE iLO Drive Array Logical Drive Condition | Monitors the Logical Drive condition.[CPQIDA-MIB :: cpqDaLogDrvCondition : 1.3.6.1.4.1.232.3.2.3.1.1.11] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
HPE iLO CPQ DA Physical Drive | hpe_ilo_drivearray_PhysicalDriveHSeekErrors | HPE iLO Drive Array Physical Drive HSeek Errors | count | Monitors the Seek Errors (High).[CPQIDA-MIB :: cpqDaPhyDrvHSeekErrs : 1.3.6.1.4.1.232.3.2.5.1.1.20] |
hpe_ilo_drivearray_PhysicalDriveHardReadErrors | HPE iLO Drive Array Physical Drive Hard Read Errors | count | Monitors the Hard Read Errors.[CPQIDA-MIB :: cpqDaPhyDrvHardReadErrs : 1.3.6.1.4.1.232.3.2.5.1.1.16] | |
hpe_ilo_drivearray_PhysicalDriveStatus | HPE iLO Drive Array Physical Drive Status | Monitors the Physical Drive Status.[CPQIDA-MIB :: cpqDaPhyDrvStatus : 1.3.6.1.4.1.232.3.2.5.1.1.6] Possible values are : 1 : other,2 : ok,3: failed,4 : predictiveFailure,5 : erasing,6 : eraseDone,7 : eraseQueued,8 : ssdWearOut,9 : notAuthenticated. | ||
hpe_ilo_drivearray_PhysicalDriveRecoveredReadErrors | HPE iLO Drive Array Physical Drive Recovered Read Errors | count | Monitors the Recovered Read Errors.[CPQIDA-MIB :: cpqDaPhyDrvRecvReadErrs : 1.3.6.1.4.1.232.3.2.5.1.1.17] | |
hpe_ilo_drivearray_PhysicalDriveHardWriteErrors | HPE iLO Drive Array Physical Drive Hard Write Errors | count | Monitors the Physical Drive Hard Write Errors.[CPQIDA-MIB :: cpqDaPhyDrvHardWriteErrs : 1.3.6.1.4.1.232.3.2.5.1.1.18] | |
hpe_ilo_drivearray_PhysicalDriveCondition | HPE iLO Drive Array Physical Drive Condition | Monitors the condition of the device. This value represents the overall condition of this physical drive.[CPQIDA-MIB :: cpqDaPhyDrvCondition : 1.3.6.1.4.1.232.3.2.5.1.1.37] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_drivearray_PhysicalDriveSSDWearStatus | HPE iLO Drive Array Physical Drive SSD Wear Status | Monitors the Drive Array Physical Drive Solid State Disk Wear Status.[CPQIDA-MIB :: cpqDaPhyDrvSSDWearStatus : 1.3.6.1.4.1.232.3.2.5.1.1.73] Possible values are : 1 : other,2 : ok,3: fiftySixDayThreshold,4 : fivePercentThreshold,5 : twoPercentThreshold,6 : ssdWearOut. | ||
hpe_ilo_drivearray_PhysicalDriveRecoveredWriteErrors | HPE iLO Drive Array Physical Drive Recovered Write Errors | count | Monitors the Physical Drive Recovered Write Errors.[CPQIDA-MIB :: cpqDaPhyDrvRecvWriteErrs : 1.3.6.1.4.1.232.3.2.5.1.1.19] | |
hpe_ilo_drivearray_PhysicalDriveSeekErrs | HPE iLO Drive Array Physical Drive Seek Errors | count | Monitors the Seek Errors (low).[CPQIDA-MIB :: cpqDaPhyDrvSeekErrs : 1.3.6.1.4.1.232.3.2.5.1.1.21] | |
hpe_ilo_drivearray_PhysicalDriveCurrentTemperature | HPE iLO Drive Array Physical Drive Current Temperature | Celsius | Monitors the Drive Array Physical Drive Current Temperature.[CPQIDA-MIB :: cpqDaPhyDrvCurrentTemperature : 1.3.6.1.4.1.232.3.2.5.1.1.70] | |
hpe_ilo_drivearray_PhysicalDriveSmartStatus | HPE iLO Drive Array Physical Drive Smart Status | Monitors the Physical Drive Smart Status.[CPQIDA-MIB :: cpqDaPhyDrvSmartStatus : 1.3.6.1.4.1.232.3.2.5.1.1.57] Possible values are : 1 : other,2 : ok,3: replaceDrive,4 : replaceDriveSSDWearOut. | ||
HPE iLO CPQ HE Environment | hpe_ilo_AsrCondition | HPE iLO Automatic Server Recovery Condition | Monitors the overall condition of the Automatic Server Recovery (ASR) feature.[CPQHLTH-MIB :: cpqHeAsrCondition : 1.3.6.1.4.1.232.6.2.5.17.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | |
hpe_ilo_BatteryBackupUnitCondition | HPE iLO Battery Backup Unit Condition | Monitors the overall condition of the BBU sub-system.[CPQHLTH-MIB :: cpqHeBbuCondition : 1.3.6.1.4.1.232.6.2.23.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_faulttolerant_PowerSupplyStatus | HPE iLO FaultTolerant PowerSupply Status | Monitors the status of the fault tolerant power supply.[CPQHLTH-MIB :: cpqHeFltTolPwrSupplyStatus : 1.3.6.1.4.1.232.6.2.9.2.0] Possible values are : 1 : other,2 : notSupported,3 : notInstalled,4 : installed. | ||
hpe_ilo_ThermalCondition | HPE iLO Thermal Condition | Monitors the overall condition of the system's thermal environment.[CPQHLTH-MIB :: cpqHeThermalCondition : 1.3.6.1.4.1.232.6.2.6.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_HardwareBiosCondition | HPE iLO Hardware Bios Condition | Monitors an error has been detected during Pre-OS Test (POST) or during initial hardware initialization. Typically,this will be a hardware interlock not closed due to an adapter or cable not properly seated in the slot. The first action is to review the iLO Event Log and iLO Integrated Management Log (IML) for a new event. If no entries found,the server will usually require a physical inspection to identify the source of the issue by observing the external and internal hardware status LEDs.[CPQHLTH-MIB :: cpqHeHWBiosCondition : 1.3.6.1.4.1.232.6.2.16.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_resilient_MemoryCondition | HPE iLO Resilient Memory Condition | Monitors the current condition of the Advanced Memory Protection subsystem.[CPQHLTH-MIB :: cpqHeResilientMemCondition : 1.3.6.1.4.1.232.6.2.14.4.0] Possible values are : 1 : other,2 : ok,3 : degraded. | ||
hpe_ilo_ThermalSystemFanStatus | HPE iLO Thermal System Fan Status | Monitors the status of the fan(s) in the system.[CPQHLTH-MIB :: cpqHeThermalSystemFanStatus : 1.3.6.1.4.1.232.6.2.6.4.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_EventLogCondition | HPE iLO Event Log Condition | Monitors the overall condition of the Integrated Management Log feature.[CPQHLTH-MIB :: cpqHeEventLogCondition : 1.3.6.1.4.1.232.6.2.11.2.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_ThermalCpuFanStatus | HPE iLO Thermal Cpu Fan Status | Monitors the status of the processor fan(s) in the system.[CPQHLTH-MIB :: cpqHeThermalCpuFanStatus : 1.3.6.1.4.1.232.6.2.6.5.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_ThermalTemperatureStatus | HPE iLO Thermal Temperature Status | Monitors the status of the system's temperature sensors.[CPQHLTH-MIB :: cpqHeThermalTempStatus : 1.3.6.1.4.1.232.6.2.6.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_SystemBackupBatteryCondition | HPE iLO System Backup Battery Condition | Monitors the overall condition of the battery backup sub-system.[CPQHLTH-MIB :: cpqHeSysBackupBatteryCondition : 1.3.6.1.4.1.232.6.2.17.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_NvdimmCondition | HPE iLO Nvdimm Condition | Monitors the overall condition of the NVDIMM sub-system.[CPQHLTH-MIB :: cpqHeNvdimmCondition : 1.3.6.1.4.1.232.6.2.22.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_faulttolerant_PowerSupplyCondition | HPE iLO FaultTolerant PowerSupply Condition | Monitors the overall condition of the fault tolerant power supply sub-system.[CPQHLTH-MIB :: cpqHeFltTolPwrSupplyCondition : 1.3.6.1.4.1.232.6.2.9.1.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_MibCondition | HPE iLO Mib Condition | Monitors the overall status of the server health system.[CPQHLTH-MIB :: cpqHeMibCondition : 1.3.6.1.4.1.232.6.1.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
HPE iLO CPQ HE Fault Tolerant Fan Health | hpe_ilo_faulttolerant_FanPresent | HPE iLO Fault Tolerant Fan Present | Monitors if the fan described is present in the system.[CPQHLTH-MIB :: cpqHeFltTolFanLocale : 1.3.6.1.4.1.232.6.2.6.7.1.3,cpqHeFltTolFanPresent : 1.3.6.1.4.1.232.6.2.6.7.1.4] Possible values are : 1 : other,2 : absent,3 : present. | |
hpe_ilo_faulttolerant_FanSpeed | HPE iLO Fault Tolerant Fan Speed | Monitors the speed of the fan.[CPQHLTH-MIB :: cpqHeFltTolFanSpeed : 1.3.6.1.4.1.232.6.2.6.7.1.6] Possible values are : 1 : other,2 : normal,3 : high. | ||
hpe_ilo_faulttolerant_FanCondition | HPE iLO Fault Tolerant Fan Condition | Monitors the condition of the fan.[CPQHLTH-MIB :: cpqHeFltTolFanCondition : 1.3.6.1.4.1.232.6.2.6.7.1.9] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
HPE iLO CPQ HE Fault Tolerant Power Supply Health | hpe_ilo_faulttolerant_PowerSupplyErrorCondition | HPE iLO FaultTolerant Power Supply Error Condition | Monitors the Error condition of the power supply.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyErrorCondition : 1.3.6.1.4.1.232.6.2.9.3.1.18] Possible values are : 1 : noError,2 : generalFailure,3 : overvoltage,4 : overcurrent,5 : overtemperature,6 : powerinputloss,7 : fanfailure,8 : vinhighwarning,9 : vinlowwarning,10 : vouthighwarning,11 : voutlowwarning,12 : inlettemphighwarning,13 : iinternaltemphighwarning,14 : vauxhighwarning,15 : vauxlowwarning,16 : vauxlowwarning,17: goodinstandby. | |
hpe_ilo_faulttolerant_PowerSupplyMainVoltage | HPE iLO Fault Tolerant Power Supply Main Voltage | v | Monitors the input main voltage of the power supply in volts.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyMainVoltage : 1.3.6.1.4.1.232.6.2.9.3.1.6] | |
hpe_ilo_fault_tolerant_PowerSupplyCondition | HPE iLO Fault Tolerant Power Supply Condition | Monitors the condition of the power supply.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyCondition : 1.3.6.1.4.1.232.6.2.9.3.1.4] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_faulttolerant_PowerSupplyCapacityUsed | HPE iLO Fault Tolerant Power Supply Capacity Used | W | Monitors the currently used capacity of the power supply in watts.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyCapacityUsed : 1.3.6.1.4.1.232.6.2.9.3.1.7] | |
hpe_ilo_faulttolerant_PowerSupplyCapacityMaximum | HPE iLO Fault Tolerant Power Supply Capacity Maximum | W | Monitors the maximum capacity of the power supply in watts.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyCapacityMaximum : 1.3.6.1.4.1.232.6.2.9.3.1.8] | |
hpe_ilo_fault_tolerant_PowerSupplyStatus | HPE iLO Fault Tolerant Power Supply Status | Monitors the status of the power supply.[CPQHLTH-MIB :: cpqHeFltTolPowerSupplyStatus : 1.3.6.1.4.1.232.6.2.9.3.1.5] Possible values are : 1 : noError,2 : generalFailure,3 : bistFailure,4 : fanFailure,5 : tempFailure,6 : interlockOpen,7 : epromFailed,8 : vrefFailed,9 : dacFailed,10 : ramTestFailed,11 : voltageChannelFailed,12 : orringdiodeFailed,13 : brownOut,14 : giveupOnStartup,15 : nvramInvalid,16 : calibrationTableInvalid,17: noPowerInput. | ||
HPE iLO CPQ HE Resilient Memory 2 Board Condition | hpe_ilo_resilient_Memory2BoardErrorStatus | HPE iLO Resilient Memory 2 Board Error Status | Monitors the error status of the Advanced Memory Protection board or Cartridge or riser.[CPQHLTH-MIB :: cpqHeResMem2BoardErrorStatus : 1.3.6.1.4.1.232.6.2.14.12.1.6] Possible values are : 1 : other,2 : noError,3 : dimmEccError,4 : unlockError,5 : configError,6 : busError,7 : powerError,8 : advancedEcc,9 : onlineSpare,10 : mirrored,11 : mirroredDimmError,12 : memoryRaid,13 : raidDimmError,14 : lockStep,15 : lockStepError,16 : a3dc,17: a3dcError. | |
hpe_ilo_resilient_Memory2BoardCondition | HPE iLO Resilient Memory 2 Board Condition | Monitors the the current status of the Advanced Memory Protection memory board or cartridge or riser.[CPQHLTH-MIB :: cpqHeResMem2BoardCondition : 1.3.6.1.4.1.232.6.2.14.12.1.11] Possible values are : 1 : other,2 : ok,3 : degraded | ||
HPE iLO CPQ HE Resilient Memory 2 Module Condition | hpe_ilo_resilient_Memory2ModuleCondition | HPE iLO Resilient Memory 2 Module Condition | Monitors the current status of the correctable memory errors for this memory module.[CPQHLTH-MIB :: cpqHeResMem2ModuleSerialNo : 1.3.6.1.4.1.232.6.2.14.13.1.12,cpqHeResMem2ModuleCondition : 1.3.6.1.4.1.232.6.2.14.13.1.20] Possible values are : 1 : other,2 : ok,3 : degraded,4 : degradedModuleIndexUnknown. | |
hpe_ilo_resilient_Memory2ModuleStatus | HPE iLO Resilient Memory 2 Module Status | Monitors the current status of the correctable memory errors for this memory module.[CPQHLTH-MIB :: cpqHeResMem2ModuleStatus : 1.3.6.1.4.1.232.6.2.14.13.1.19] Possible values are : 1 : other,2 : notPresent,3: present,4 : good,5 : add,6 : upgrade,7 : missing,8 : doesNotMatch,9 : notSupported,10 : badConfig,11 : degraded,12 : spare,13 : partial,14 : configError,15 : trainingFailure. | ||
HPE iLO CPQ HE System Battery Condition | hpe_ilo_SystemBatteryCondition | HPE iLO System Battery Condition | Monitors the condition of the backup battery.[CPQHLTH-MIB :: cpqHeSysBatteryCondition : 1.3.6.1.4.1.232.6.2.17.2.1.4] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | |
hpe_ilo_SystemBatteryPresent | HPE iLO System Battery Present | Monitors whether the backup battery is present in the chassis.[CPQHLTH-MIB :: cpqHeSysBatteryPresent : 1.3.6.1.4.1.232.6.2.17.2.1.3,cpqHeSysBatterySerialNumber : 1.3.6.1.4.1.232.6.2.17.2.1.9] Possible values are : 1 : other,2 : absent,3 : present. | ||
hpe_ilo_SystemBatteryStatus | HPE iLO System Battery Status | Monitors the status of the battery.[CPQHLTH-MIB :: cpqHeSysBatteryStatus : 1.3.6.1.4.1.232.6.2.17.2.1.5] Possible values are : 1 : noError,2 : generalFailure,3: shutdownHighResistance,4 : shutdownLowVoltage,5 : shutdownShortCircuit,6 : shutdownChargeTimeout,7 : shutdownOverTemperature,8 : shutdownDischargeMinVoltage,9 : shutdownDischargeCurrent,10 : shutdownLoadCountHigh,11 : shutdownEnablePin,12 : shutdownOverCurrent,13 : shutdownPermanentFailure,14 : shutdownBackupTimeExceeded,15 : predictiveFailure. | ||
HPE iLO CPQ HE Temperature Sensor Health | hpe_ilo_TemperatureCondition | HPE iLO Temperature Condition | Monitors the Temperature sensor condition.[CPQHLTH-MIB :: cpqHeTemperatureCondition : 1.3.6.1.4.1.232.6.2.6.8.1.6] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | |
hpe_ilo_TemperatureCelsius | HPE iLO Temperature Celsius | Celsius | Monitors the current temperature sensor reading in degrees celsius.[CPQHLTH-MIB :: cpqHeTemperatureLocale : 1.3.6.1.4.1.232.6.2.6.8.1.3,cpqHeTemperatureCelsius : 1.3.6.1.4.1.232.6.2.6.8.1.4] | |
HPE iLO CPQ NIC Condition | hpe_ilo_NicMibCondition | HPE iLO NIC Mib Condition | Monitors the overall status of the NIC.[CPQNIC-MIB :: cpqNicMibCondition : 1.3.6.1.4.1.232.18.1.3.0] Possible values are : 1 : unknown,2 : ok,3 : degraded,4 : failed. | |
HPE iLO CPQ SE CPU Cache Status | hpe_ilo_se_CpuCacheStatus | HPE iLO SE CPU Cache Status | Monitors the status of the cache unit. If the cache is optional and not installed,unknown(1) will be returned.[CPQSTDEQ-MIB :: cpqSeCpuCacheUnitIndex : 1.3.6.1.4.1.232.1.2.2.3.1.1,cpqSeCpuCacheLevelIndex : 1.3.6.1.4.1.232.1.2.2.3.1.2,cpqSeCpuCacheStatus : 1.3.6.1.4.1.232.1.2.2.3.1.5] Possible values are : 1 : unknown,2 : ok,3 : degraded,4 : failed. | |
HPE iLO CPQ SE CPU Status | hpe_ilo_se_CpuStatus | HPE iLO SE CPU Status | Monitors the status of the processor.[CPQSTDEQ-MIB :: cpqSeCpuStatus : 1.3.6.1.4.1.232.1.2.2.1.1.6] Possible values are : 1 : unknown,2 : ok,3 : degraded,4 : failed,5 : disabled. | |
HPE iLO CPQ SE Overall Condition | hpe_ilo_se_MibCondition | HPE iLO SE Mib Condition | Monitors the overall condition of the server.[CPQSTDEQ-MIB :: cpqSeMibCondition : 1.3.6.1.4.1.232.1.1.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | |
hpe_ilo_se_CpuCondition | HPE iLO SE CPU Condition | Monitors the the overall condition of the processor sub-system.[CPQSTDEQ-MIB :: cpqSeCpuCondition : 1.3.6.1.4.1.232.1.2.2.4.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
HPE iLO CPQ SI Condition | hpe_ilo_server_information_MibCondition | HPE iLO Server Information Mib Condition | Monitors the overall status of the CPQ server information.[CPQSINFO-MIB :: cpqSiMibCondition : 1.3.6.1.4.1.232.2.1.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | |
HPE iLO CPQ SM2 ILO | hpe_ilo_sm2_MibCondition | HPE iLO SM2 Mib Condition | Monitors the overall condition of the Remote Insight/ Integrated Lights-Out.[CPQSM2-MIB :: cpqSm2MibCondition : 1.3.6.1.4.1.232.9.1.3.0] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | |
hpe_ilo_sm2_ControllerExternalPowerCableStatus | HPE iLO SM2 Controller External PowerCable Status | Monitors the Remote Insight External Power Cable Status.[CPQSM2-MIB :: cpqSm2CntlrExternalPowerCableStatus : 1.3.6.1.4.1.232.9.2.2.25.0] Possible values are : 1 : other,2 : externallyConnected,3 : disconnected,4 : internallyConnected,5 : externallyAndInternallyConnected,6 :notApplicable. | ||
hpe_ilo_sm2_ControllerBatteryStatus | HPE iLO SM2 Controller Battery Status | Monitors the remote insight battery status.[CPQSM2-MIB :: cpqSm2CntlrBatteryStatus : 1.3.6.1.4.1.232.9.2.2.5.0] Possible values are : 1 : other,2 : batteryOk,3 : batteryFailed,4 : batteryDisconnected. | ||
hpe_ilo_sm2_ControllerInterfaceStatus | HPE iLO SM2 Controller Interface Status | Monitors the Remote Insight/ Integrated Lights-Out Interface Status.[CPQSM2-MIB :: cpqSm2CntlrInterfaceStatus : 1.3.6.1.4.1.232.9.2.2.17.0] Possible values are : 1 : other,2 : ok,3 : notResponding. | ||
hpe_ilo_sm2_ControllerVirtualPowerCableStatus | HPE iLO SM2 Controller Virtual PowerCable Status | Monitors the Remote Insight Virtual Power Cable Status.[CPQSM2-MIB :: cpqSm2CntlrVirtualPowerCableStatus : 1.3.6.1.4.1.232.9.2.2.24.0] Possible values are : 1 : other,2 : connected,3 : disconnected,4 : notApplicable. | ||
HPE iLO CPQ SM2 NIC Condition | hpe_ilo_sm2_NicCondition | HPE iLO SM2 NIC Condition | Monitors the overall condition of the Remote Insight / Integrated Lights-Out Network Interface Controller (NIC).[CPQSM2-MIB :: cpqSm2NicLocation : 1.3.6.1.4.1.232.9.2.5.1.1.1,cpqSm2NicCondition : 1.3.6.1.4.1.232.9.2.5.1.1.11] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | |
HPE iLO NIC Physical Adapter | hpe_ilo_nic_PhysicalAdapterInternalMacTransmitErrors | HPE iLO NIC Physical Adapter Internal Mac Transmit Errors | count | Monitors the count of frames for which transmission on a particular interface fails due to an internal MAC sublayer transmit error.[CPQNIC-MIB :: cpqNicIfPhysAdapterInternalMacTransmitErrors : 1.3.6.1.4.1.232.18.2.3.1.1.27] |
hpe_ilo_nic_PhysicalAdapterFCSErrors | HPE iLO NIC Physical Adapter FCS Errors | count | Monitors the count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check.[CPQNIC-MIB :: cpqNicIfPhysAdapterFCSErrors : 1.3.6.1.4.1.232.18.2.3.1.1.21] | |
hpe_ilo_nic_PhysicalAdapterDeferredTransmissions | HPE iLO NIC Physical Adapter Deferred Transmissions | count | Monitors the number of packets deferred before transmission. This counter contains the number of packets whose transmission was delayed on its first attempt because the medium was busy. Packets involved in any collisions are not counted. Frames that wait before transmission are counted.This statistic will be incremented often during normal operation on a busy network.[CPQNIC-MIB :: cpqNicIfPhysAdapterDeferredTransmissions : 1.3.6.1.4.1.232.18.2.3.1.1.24] | |
hpe_ilo_nic_PhysicalAdapterStatus | HPE iLO NIC Physical Adapter Status | Monitors the physical adapter status.[CPQNIC-MIB :: cpqNicIfPhysAdapterStatus : 1.3.6.1.4.1.232.18.2.3.1.1.14] Possible values are : 1 : unknown,2 : ok,3 : generalFailure,4 : linkFailure. | ||
hpe_ilo_nic_PhysicalAdapterMultipleCollisionFrames | HPE iLO NIC Physical Adapter Multiple Collision Frames | count | Monitors the number of multiple collision packets. This counter contains the number of packets that are involved in multiple collisions and are subsequently transmitted successfully.[CPQNIC-MIB :: cpqNicIfPhysAdapterMultipleCollisionFrames : 1.3.6.1.4.1.232.18.2.3.1.1.23] | |
hpe_ilo_nic_PhysicalAdapterSingleCollisionFrames | HPE iLO NIC Physical Adapter Single Collision Frames | count | Monitors the number of single collision packets. This counter contains the number of packets that are involved in a single collision and are subsequently transmitted successfully.[CPQNIC-MIB :: cpqNicIfPhysAdapterSingleCollisionFrames : 1.3.6.1.4.1.232.18.2.3.1.1.22] | |
hpe_ilo_nic_PhysicalAdapterState | HPE iLO NIC Physical Adapter State | Monitors the fault tolerant state of this adapter.[CPQNIC-MIB :: cpqNicIfPhysAdapterState : 1.3.6.1.4.1.232.18.2.3.1.1.13] Possible values are : 1 : unknown,2 : active,3 : standby,4 : failed. | ||
hpe_ilo_nic_PhysicalAdapterAlignmentErrors | HPE iLO NIC Physical Adapter Alignment Errors | count | Monitors the count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check.The alignment of a frame is checked by the receiver after the packet has failed the Cyclical Redundancy Check (CRC). Misaligned packets do not end on an 8-bit boundary.All packets contain a set number of bytes and must end after a defined number of bytes.Packets that do not end on a byte boundary fail the alignment check.[CPQNIC-MIB :: cpqNicIfPhysAdapterAlignmentErrors : 1.3.6.1.4.1.232.18.2.3.1.1.20] | |
hpe_ilo_nic_PhysicalAdapterBadTransmits | HPE iLO NIC Physical Adapter Bad Transmits | count | Monitors the count of frames that were not transmitted by the adapter because of an error.[CPQNIC-MIB :: cpqNicIfPhysAdapterBadTransmits : 1.3.6.1.4.1.232.18.2.3.1.1.18] | |
hpe_ilo_nic_PhysicalAdapterLateCollisions | HPE iLO NIC Physical Adapter Late Collisions | count | Monitors the Late collisions may be a symptom of cabling problems.[CPQNIC-MIB :: cpqNicIfPhysAdapterLateCollisions : 1.3.6.1.4.1.232.18.2.3.1.1.25] | |
hpe_ilo_nic_PhysicalAdapterBadReceives | HPE iLO NIC Physical Adapter Bad Receives | count | Monitors the count of frames that were received by the adapter but which had an error.[CPQNIC-MIB :: cpqNicIfPhysAdapterBadReceives : 1.3.6.1.4.1.232.18.2.3.1.1.19] | |
hpe_ilo_nic_PhysicalAdapterInternalMacReceiveErrors | HPE iLO NIC Physical Adapter Internal Mac Receive Errors | count | Monitors the count of frames for which reception on a particular interface fails due to an internal MAC sublayer receive error.[CPQNIC-MIB :: cpqNicIfPhysAdapterInternalMacReceiveErrors : 1.3.6.1.4.1.232.18.2.3.1.1.30] | |
hpe_ilo_nic_PhysicalAdapterCondition | HPE iLO NIC Physical Adapter Condition | Monitors the condition of this physical adapter.[CPQNIC-MIB :: cpqNicIfPhysAdapterCondition : 1.3.6.1.4.1.232.18.2.3.1.1.12] Possible values are : 1 : other,2 : ok,3 : degraded,4 : failed. | ||
hpe_ilo_nic_PhysicalAdapterExcessiveCollisions | HPE iLO NIC Physical Adapter Excessive Collisions | count | Monitors the number of packets aborted during transmission due to excessive collisions.[CPQNIC-MIB :: cpqNicIfPhysAdapterExcessiveCollisions : 1.3.6.1.4.1.232.18.2.3.1.1.26] | |
hpe_ilo_nic_PhysicalAdapterCarrierSenseErrors | HPE iLO NIC Physical Adapter Carrier Sense Errors | count | Monitors the number of packets transmitted with carrier sense errors.[CPQNIC-MIB :: cpqNicIfPhysAdapterCarrierSenseErrors : 1.3.6.1.4.1.232.18.2.3.1.1.28] |
HPE LeftHand SAN Cluster - G2
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Manager Status | lefthand.cluster.manager | Cluster Manager Status | Provides the manager name and status. Possible Manager status are 1- Up,2- Down.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.44.1.2,1.3.6.1.4.1.9804.3.1.1.2.12.44.1.5,1.3.6.1.4.1.9804.3.1.1.2.12.44.1.7,1.3.6.1.4.1.9804.3.1.1.2.12.44.1.9] |
HPE LeftHand SAN Cluster - G3
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Performance Monitor | lefthand.cluster.available.space | Cluster Available Space | GB | Space available to create volumes. Here used space will be subtracted from total space. |
HPE LeftHand SAN Cluster - G4
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Performance Monitor | lefthand.cluster.total.space | Cluster Total Space | GB | The total space for data storage in the cluster.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.48.1.29] |
HPE LeftHand SAN Cluster - G5
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Performance Monitor | lefthand.cluster.used.space | Cluster Used Space | GB | The amount of storage space that has been used in the cluster.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.48.1.31] |
HPE LeftHand SAN Cluster - G6
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Performance Monitor | lefthand.cluster.space.utilization | Cluster Space Utilization | % | The percentage of storage space that has been used in the cluster. Here used space and total space metrics are used for calculating utilization. |
HPE LeftHand SAN Cluster - G7
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Performance Monitor | lefthand.cluster.read.latency | Cluster Read Latency | ms | The total time spent waiting for read operations to complete in the cluster. The difference between current and the previous value of clusClusterStatsIoLatencyRead object will be considered.[OID:1.3.6.1.4.1.9804.3.1.1.2.12.48.1.26] |
HPE LeftHand SAN Cluster - G8
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Performance Monitor | lefthand.cluster.write.latency | Cluster Write Latency | ms | The total time spent waiting for write operations to complete in the cluster. The difference between current and the previous value of clusClusterStatsIoLatencyWrite object will be considered.[OID:1.3.6.1.4.1.9804.3.1.1.2.12.48.1.27] |
HPE LeftHand SAN Cluster - G9
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Volume Snapshot Monitor | lefthand.cluster.volume.snapshot.latency.read | Snapshot Latency Read | ms | The total time spent waiting for read operations to complete on the snapshot.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.101.1.42] |
HPE LeftHand SAN Cluster - G10
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Volume Snapshot Monitor | lefthand.cluster.volume.snapshot.latency.write | Snapshot Latency Write | ms | The total time spent waiting for write operations to complete on the snapshot.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.101.1.43] |
HPE LeftHand SAN Cluster - G11
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Volume Snapshot Monitor | lefthand.cluster.volume.snapshot.used.percent | Snapshot Used Percent | % | The space used by the snapshot as a percentage of the cluster space.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.101.1.31] |
HPE LeftHand SAN Cluster - G12
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Volume Snapshot Monitor | lefthand.cluster.volume.snapshot.replication.status | Snapshot Replication Status | The snapshot replication status. The status will be normal if the snapshot is available,faulty otherwise.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.101.1.14] |
HPE LeftHand SAN Cluster - G13
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Volume Space | lefthand.cluster.volume.size | Cluster Volume Size | GB | The volume size of the cluster. (Reported Size) [OID: 1.3.6.1.4.1.9804.3.1.1.2.12.97.1.5] |
HPE LeftHand SAN Cluster - G14
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Volume Space | lefthand.cluster.volume.available.space | Cluster Volume Available Space | GB | The storage space available in the volume before the size is reached. For thinly provisioned volumes the cluster must have sufficient storage space to support this.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.97.1.51] |
HPE LeftHand SAN Cluster - G15
Description
Applicable on the HP LeftHand SAN devices. Monitors the space pool,storage latency,volume usage and volume latency.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP LeftHand SAN Cluster Volume Space | lefthand.cluster.volume.used.percent | Cluster Volume Used Percent | % | The percentage of storage space that has been used on the volume.[OID: 1.3.6.1.4.1.9804.3.1.1.2.12.97.1.52] |
HPE LeftHand SAN Health Check - G2
Description
This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand Cache Status | lefthand.san.health.cache.status | Cache Status | The RAID controller cache status. Possible values are 1 - Pass 2 - Failed [OID: 1.3.6.1.4.1.9804.3.1.1.2.1.91.1.91] |
HPE LeftHand SAN Health Check - G3
Description
This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand Cache Status | lefthand.san.health.cache.bbu.status | Battery Backup Unit(BBU) Status | Gives cache's BBU (Battery Backup Unit) status. Possible values are 1.Pass 2.Fail [OID:1.3.6.1.4.1.9804.3.1.1.2.1.91.1.23] |
HPE LeftHand SAN Health Check - G4
Description
This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand Fan Status | lefthand.fan.status | Fan Status | It monitors the fan status.[OIDs:1.3.6.1.4.1.9804.3.1.1.2.1.111.1.90,1.3.6.1.4.1.9804.3.1.1.2.1.111.1.91] |
HPE LeftHand SAN Health Check - G5
Description
This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand Power Status | lefthand.power.supply.state | Power Supply State | It returns power supply state and status.[OID:1.3.6.1.4.1.9804.3.1.1.2.1.131.1.90,1.3.6.1.4.1.9804.3.1.1.2.1.131.1.91] |
HPE LeftHand SAN Health Check - G6
Description
This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand Storage Device Smart Health Status | storage.device.smart.health.status | Storage Device Smart Health Status | The device SMART health status. Possible values are 1. Pass 2. Fail.[OID:1.3.6.1.4.1.9804.3.1.1.2.4.2.1.18] |
HPE LeftHand SAN Health Check - G7
Description
This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand Temperature Status | lefthand.temperature.sensor.value | Temperature Sensor Value | Celsius | The temperature sensor value in Celsius.[OID:1.3.6.1.4.1.9804.3.1.1.2.1.121.1.3] |
HPE LeftHand SAN Health Check - G8
Description
This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand Temperature Status | lefthand.temperature.sensor.status | Temperature Sensor Status | The temperature sensor status. Passible values are 1.Pass 2.Fail [OID: 1.3.6.1.4.1.9804.3.1.1.2.1.121.1.91] |
HPE LeftHand SAN Health Check - G9
Description
This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand Voltage Sensor Status | lefthand.voltage.sensor.value | Voltage Sensor Value | v | The voltage sensor value in Volts.[OID:1.3.6.1.4.1.9804.3.1.1.2.1.141.1.3] |
HPE LeftHand SAN Health Check - G10
Description
This template is applicable for LeftHand SAN devices.Monitors the environmental parameters like fan,power,temperature,voltage etc along with the cache status.[LEFTHAND-NETWORKS-NSM-INFO-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand Voltage Sensor Status | lefthand.voltage.sensor.status | Voltage Sensor Status | The voltage sensor status.Possible values are 1- Pass,2- Fail.[OID: 1.3.6.1.4.1.9804.3.1.1.2.1.141.1.91] |
HPE LeftHand SAN NSM Storage Status - G2
Description
Applicable on LeftHand SAN NSM devices. Monitors the storage device status and the raid status on the NSM storage.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand NSM Raid Status | lefthand.raid.status | Raid Status | Monitors the RAID status. Possible values are 1- pass,2- fail.[OIDs: 1.3.6.1.4.1.9804.3.1.1.2.4.11.0,1.3.6.1.4.1.9804.3.1.1.2.4.23.0,1.3.6.1.4.1.9804.3.1.1.2.4.24.0] | |
Lefthand NSM Storage | lefthand.storage.device.status | Storage Device Status | Monitors the storage device status. Possible values are 1- pass,2- fail.[OIDs: 1.3.6.1.4.1.9804.3.1.1.2.4.2.1.14,1.3.6.1.4.1.9804.3.1.1.2.4.2.1.90,1.3.6.1.4.1.9804.3.1.1.2.4.2.1.91] |
HPE LeftHand SAN NUS Storage Status - G2
Description
Applicable on HP Lefthand SAN NUS devices. Monitors the raid status and the storage device temperature.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Lefthand NUS Raid Status | lefthand.nus.raid.status | Raid Status | Monitors the status of raid subsystem. Possible values are 1 - Normal 2 - Rebuilding 3 - Degraded 4 - Not rebuilding 5 - Off.[OID: 1.3.6.1.4.1.9804.3.1.1.2.4.7.0] | |
Lefthand NUS Storage | lefthand.nus.storage.device.temperature | Storage Device Status | C | Monitors the storage device temperature.[OIDs: 1.3.6.1.4.1.9804.3.1.1.2.4.2.1.2,1.3.6.1.4.1.9804.3.1.1.2.4.2.1.3,1.3.6.1.4.1.9804.3.1.1.2.4.2.1.5,1.3.6.1.4.1.9804.3.1.1.2.4.2.1.9] |
HP Procurve Switch - G2
Description
Monitoring template for HP Procurve switches. Monitors memory usage,CPU utilization,System temperature,chassis sensor status,power supply state,power supply temperature,fan status and uptime.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP ICF Chassis Module Status | module.status | Module Status | Module status: A textual description of the card plugged into this slot in this chassis,including the product number and version information. Specifically,hpicfSlotDesc (1.3.6.1.4.1.11.2.14.11.1.2.3.1.4) will throw three possible values back:1. A description of the module installed in the slot. (Example: "HP J9534A 24p Gig-T PoE+ v2 zl Module")2. An empty slot description ("Slot Available")3. A failure message ("Module Failed") for a failed,non-empty slot. Alert will generate on #3 condition(i.e "Module Failed"). | |
HP ICF Fan | hp.icf.fan.state | Fan State | The current state of the HP Switch fan.[OID: 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.4] | |
HP ICF Power Supply | hp.icf.ps.state | Power Supply State | The physical state of the switch power supply entity.[OID: 1.3.6.1.4.1.11.2.14.11.5.1.55.1.1.1.2] | |
hp.icf.ps.temperature | Power Supply Temperature | Celsius | The temperature of the power supply in Celsius.[OID: 1.3.6.1.4.1.11.2.14.11.5.1.55.1.1.1.4] | |
HP Procurve CPU Utilization | system.cpu.utilization | CPU Utilization | % | It represents the HP ProCurve CPU Utilization. |
HP Procurve Global Memory Utilization | system.memory.util.percent | Memory Utilization | % | The system dynamic memory utilization,in unit of percentage. Memory Utilization is the percent of memory used in comparison to the total memory bytes and used memory bytes. |
HP Procurve Sensor Status | hp.procurve.sensor.status | HP Procurve Sensor Status | Actual status indicated by the HP Procurve sensor. These are the possible sensor values(1: Unknown 2: Bad 3: Warning 4: Good 5: NotPresent). | |
HP ProCurve System Temperature | system.temperature | System Temperature | C | It monitors the system temperature of HP Switches which support the HP-ICF-CHASSIS-MIB. |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
HPE Proliant - Array Controller Monitors
Description
It is applicable for HPE Proliant blade systems which have the Compaq/HPs Insight Manager SNMP agents installed on either Windows or Linux machines.Monitors the status of the array controller,logical and physical drives and rack servers along with the environmental parameters like fan,power and temperature.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
CPQ DA Array Controller Status | arraycontroller.status | CPQ DA Array Controller Condition | Monitors the overall condition of this controller,and any associated logical drives,physical drives,and array accelerators. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.2.1.1.1,1.3.6.1.4.1.232.3.2.2.1.1.6] | |
CPQ DA Logical Drive | logical.disk.status | CPQ DA Logical Drive Condition | Monitors the overall condition of this logical drive and any associated physical drives. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.3.1.1.1,1.3.6.1.4.1.232.3.2.3.1.1.2,1.3.6.1.4.1.232.3.2.3.1.1.11] | |
CPQ DA Physical Drive | cpq.da.physical.drive.condition | CPQ DA Physical Drive Condition | Monitors the overall condition of this physical drive. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.3.2.5.1.1.1,1.3.6.1.4.1.232.3.2.5.1.1.2,1.3.6.1.4.1.232.3.2.5.1.1.37] | |
cpq.da.physical.drive.smartstatus | CPQ DA Physical Drive SMART Status | Monitors the physical drive S.M.A.R.T status. Possible values are 1- other: The agent is unable to determine if the status of S.M.A.R.T predictive failure monitoring for this drive,2- ok: Indicates the drive is functioning properly,3- replaceDrive: Indicates that the drive has a S.M.A.R.T predictive failure error and should be replaced.[OIDs: 1.3.6.1.4.1.232.3.2.5.1.1.1,1.3.6.1.4.1.232.3.2.5.1.1.2,1.3.6.1.4.1.232.3.2.5.1.1.57] | ||
CPQ Rack Fan Enclosure Status | hp.proliant.rack.fan.enclosure.status | Rack Fan Enclosure Status | Rack Fan Enclosure Status. Possible values are other(1) - Fan status detection is not supported. ok(2) - The fan is operating properly. degraded(2) - A redundant fan is not operating properly. failed(4) - A non-redundant fan is not operating properly.[OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.1,1.3.6.1.4.1.232.22.2.3.1.3.1.2,1.3.6.1.4.1.232.22.2.3.1.3.1.3,1.3.6.1.4.1.232.22.2.3.1.3.1.4,1.3.6.1.4.1.232.22.2.3.1.3.1.11] | |
CPQ Rack Power Enclosure Status | rack.power.enclosure.status | Rack Power Enclosure Status | Rack Power Enclosure Status. Possible values are 1- Other,2-OK,3- Degraded.[OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.1,1.3.6.1.4.1.232.22.2.3.3.1.1.2,1.3.6.1.4.1.232.22.2.3.3.1.1.3,1.3.6.1.4.1.232.22.2.3.3.1.1.9] | |
CPQ Rack Power Status | rack.power.status | Rack Power Status | Power supply status. Possible values are other(1) - The status could not be determined or not present. ok(2) - The power supply is operating normally. degraded(3) - A temperature sensor,fan or other power supply component is outside of normal operating range. failed(4) - A power supply component detects a condition that could possibly damage the system.[OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.1,1.3.6.1.4.1.232.22.2.5.1.1.1.2,1.3.6.1.4.1.232.22.2.5.1.1.1.3,1.3.6.1.4.1.232.22.2.5.1.1.1.4,1.3.6.1.4.1.232.22.2.5.1.1.1.17] | |
CPQ Rack Server Blade Status | hp.proliant.rack.server.blade.status | Rack Server Blade Status | The health status of the blade. Possible values are 1 - Other,2 -OK,3 - Degraded,4 - Failed.[OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.1,1.3.6.1.4.1.232.22.2.4.1.1.1.2,1.3.6.1.4.1.232.22.2.4.1.1.1.3,1.3.6.1.4.1.232.22.2.4.1.1.1.4,1.3.6.1.4.1.232.22.2.4.1.1.1.5,1.3.6.1.4.1.232.22.2.4.1.1.1.21] | |
CPQ Rack Server Temperature Status | hp.proliant.rack.server.temperature.status | Rack Server Temperature Status | The Temperature sensor status of Rack server. Possible values are other(1) - Temperature could not be determined. ok(2) - The temperature sensor is within the normal operating range. degraded(3) - The temperature sensor is outside of the normal operating range. failed(4) - The temperature sensor detects a condition that could possibly overheat the system.[OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.1,1.3.6.1.4.1.232.22.2.4.3.1.1.2,1.3.6.1.4.1.232.22.2.4.3.1.1.3,1.3.6.1.4.1.232.22.2.4.3.1.1.4,1.3.6.1.4.1.232.22.2.4.3.1.1.10] | |
CPQ Rack Temperature Enclosure Status | hp.proliant.rack.temperature.enclosure.status | Rack Temperature Enclosure Status | The Temperature sensor status. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.22.2.3.1.2.1.1,1.3.6.1.4.1.232.22.2.3.1.2.1.2,1.3.6.1.4.1.232.22.2.3.1.2.1.3,1.3.6.1.4.1.232.22.2.3.1.2.1.4,1.3.6.1.4.1.232.22.2.3.1.2.1.8] |
HPE Proliant - Rack Monitors
Description
It is applicable for HPE Proliant blade systems which have the Compaq/HPs Insight Manager SNMP agents installed on either Windows or Linux machines and also on HP switches meant for HP Blade systems. Monitors the rack enclosure status and status of the rack servers along with the environmental parameters like fan,power and temperature. For example,GbE2c Ethernet Blade switch.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
CPQ Rack Enclosure Status | enclosure.status | Enclosure Status | The overall condition of the enclosure. This is the aggregate of the temperature sensors,fans,and fuses within the enclosure. Possible values are other(1) - No temperature sensors,fans,or fuses in the enclosure or the state could no be determined. ok(2) - All temperature sensors,fans,and fuses are within the normal operating range. degraded(3) - One or more temperature sensors,fans,or fuses are outside of the normal operating range. None are failed. failed(4) - The temperature sensor exceeded the critical threshold value,a required fan has failed,or a fuse has been tripped.[OIDs: 1.3.6.1.4.1.232.22.2.3.1.1.1.9,1.3.6.1.4.1.232.22.2.3.1.1.1.16] | |
CPQ Rack Fan Enclosure Status | hp.proliant.rack.fan.enclosure.status | Rack Fan Enclosure Status | Rack Fan Enclosure Status. Possible values are other(1) - Fan status detection is not supported. ok(2) - The fan is operating properly. degraded(2) - A redundant fan is not operating properly. failed(4) - A non-redundant fan is not operating properly.[OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.1,1.3.6.1.4.1.232.22.2.3.1.3.1.2,1.3.6.1.4.1.232.22.2.3.1.3.1.3,1.3.6.1.4.1.232.22.2.3.1.3.1.4,1.3.6.1.4.1.232.22.2.3.1.3.1.11] | |
CPQ Rack Power Enclosure Status | rack.power.enclosure.status | Rack Power Enclosure Status | Rack Power Enclosure Status. Possible values are 1- Other,2-OK,3- Degraded.[OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.1,1.3.6.1.4.1.232.22.2.3.3.1.1.2,1.3.6.1.4.1.232.22.2.3.3.1.1.3,1.3.6.1.4.1.232.22.2.3.3.1.1.9] | |
CPQ Rack Power Status | rack.power.status | Rack Power Status | Power supply status. Possible values are other(1) - The status could not be determined or not present. ok(2) - The power supply is operating normally. degraded(3) - A temperature sensor,fan or other power supply component is outside of normal operating range. failed(4) - A power supply component detects a condition that could possibly damage the system.[OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.1,1.3.6.1.4.1.232.22.2.5.1.1.1.2,1.3.6.1.4.1.232.22.2.5.1.1.1.3,1.3.6.1.4.1.232.22.2.5.1.1.1.4,1.3.6.1.4.1.232.22.2.5.1.1.1.17] | |
CPQ Rack Server Blade Status | hp.proliant.rack.server.blade.status | Rack Server Blade Status | The health status of the blade. Possible values are 1 - Other,2 -OK,3 - Degraded,4 - Failed.[OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.1,1.3.6.1.4.1.232.22.2.4.1.1.1.2,1.3.6.1.4.1.232.22.2.4.1.1.1.3,1.3.6.1.4.1.232.22.2.4.1.1.1.4,1.3.6.1.4.1.232.22.2.4.1.1.1.5,1.3.6.1.4.1.232.22.2.4.1.1.1.21] | |
CPQ Rack Server Temperature Status | hp.proliant.rack.server.temperature.status | Rack Server Temperature Status | The Temperature sensor status of Rack server. Possible values are other(1) - Temperature could not be determined. ok(2) - The temperature sensor is within the normal operating range. degraded(3) - The temperature sensor is outside of the normal operating range. failed(4) - The temperature sensor detects a condition that could possibly overheat the system.[OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.1,1.3.6.1.4.1.232.22.2.4.3.1.1.2,1.3.6.1.4.1.232.22.2.4.3.1.1.3,1.3.6.1.4.1.232.22.2.4.3.1.1.4,1.3.6.1.4.1.232.22.2.4.3.1.1.10] | |
CPQ Rack Temperature Enclosure Status | hp.proliant.rack.temperature.enclosure.status | Rack Temperature Enclosure Status | The Temperature sensor status. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OIDs: 1.3.6.1.4.1.232.22.2.3.1.2.1.1,1.3.6.1.4.1.232.22.2.3.1.2.1.2,1.3.6.1.4.1.232.22.2.3.1.2.1.3,1.3.6.1.4.1.232.22.2.3.1.2.1.4,1.3.6.1.4.1.232.22.2.3.1.2.1.8] |
HPE Proliant - Server Health Monitors
Description
This template is used for checking different health parameters of Compaq and HPE Proliant Servers. Monitors CPU fan thermal health,temperature sensor health,system fans health,over server thermal health,chassis fan health,etc. It is also applicable for HPE Proliant servers/blade systems which have the Compaq/HPs insight Manager SNMP agents installed on either Windows or Linux machines. Monitors the CPU and environmental parameters like fan,power and temperature across the different components in the system.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
CPQ HE Environment | cpu.fan.thermal.health | CPQ CPU Fan Thermal Health | Provides the status of the processor fan(s) in the system. This value will be one of the following:- other(1): Fan status detection is not supported by this system or driver,ok(2): All fans are operating properly,failed(4): A fan is not operating properly. System will be shutdown if the failed(4) condition occurs.[OID: 1.3.6.1.4.1.232.6.2.6.5.0] | |
temperature.sensors.health | CPQ System Temperature Sensors Status | Provides the status of the system's temperature sensors. This value will be one of the following:- other(1): Temp sensing is not supported by this system or driver,ok(2): All temp sensors are within normal operating range,degraded(3): A temp sensor is outside of normal operating range,failed(4): A temp sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results.[OIDs: 1.3.6.1.4.1.232.6.2.6.3.0] | ||
system.fans.health | CPQ System Fans Status | The status of the fan(s) in the system. This value will be one of the following:- other(1): Fan status detection is not supported by this system or driver,ok(2): All fans are operating properly,degraded(3): A non-required fan is not operating properly,failed(4): A required fan is not operating properly.[OID: 1.3.6.1.4.1.232.6.2.6.4.0] | ||
over.server.thermal.health | CPQ Thermal Environment Overall Health | Specifies the overall condition of the system's thermal environment.[OID: 1.3.6.1.4.1.232.6.2.6.1.0] | ||
hp.ilo.cpq.he.condition | CPQ Server Health System Overall Status | Monitors the overall status of the server health system. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.1.3.0] | ||
hp.ilo.cpq.he.asr.condition | CPQ Server Health ASR Overall Condition | Monitors the overall condition of the Automatic Server Recovery (ASR) feature. Possible values are 1- Other,2- OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.5.17.0] | ||
hp.ilo.cpq.he.eventlog.condition | CPQ HE Event Log Condition | Monitors the overall condition of the integrated management log feature. Possible values are 1- Other,2- OK,3- degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.11.2.0] | ||
hp.ilo.cpq.he.resillent.memory.condition | CPQ HE Resilient Memory Condition | Monitors the current condition of the Advanced Memory Protection subsystem. Possible values are 1- other: The system does not support fault tolerant memory or the state cannot be determined by the Management Agent,2- ok: This system is operating normally,3- degraded: The system is running in a degraded state because the Advanced Memory Protection subsystem has been engaged.[OID: 1.3.6.1.4.1.232.6.2.14.4.0] | ||
cpq.ss.condition | CPQ Storage System Overall Condition | Monitors the overall condition (status) of the storage system. Possible values are 1- Other,2- OK,3- Degraded.[OID: 1.3.6.1.4.1.232.8.1.3.0] | ||
cpq.he.fault.tolerant.powersupply.condition | CPQ HE Fault Tolerant Power Supply Condition | Monitors the overall condition of the fault tolerant power supply sub-system. Possible values are 1- Other,2-OK,3- Degraded,4- Failed.[OID: 1.3.6.1.4.1.232.6.2.9.1.0] | ||
CPQ HE Fault Tolerant Fan Health | fault.tolerant.fan.status | CPQ HE Fault Tolerent Fan Health | Provides the condition of the fan. Possible values are 1- other: Fan status detection is not supported by this system or driver,2- ok: The fan is operating properly,3- degraded: A redundant fan is not operating properly,4- failed: A non-redundant fan is not operating properly.[OIDs: 1.3.6.1.4.1.232.6.2.6.7.1.1,1.3.6.1.4.1.232.6.2.6.7.1.2,1.3.6.1.4.1.232.6.2.6.7.1.9] | |
CPQ HE Power Supply Health | fault.tolerant.power.supply.status | CPQ Fault Tolerant Power Supply Health | Monitors the condition of the power supply. Possible values are 1- other: The status could not be determined or not present,2- ok: The power supply is operating normally,3- degraded: Power supply is outside of normal operating range,4- failed: power supply component detects a condition that could permanently damage the system.[OIDs: 1.3.6.1.4.1.232.6.2.9.3.1.4,1.3.6.1.4.1.232.6.2.9.3.1.1,1.3.6.1.4.1.232.6.2.9.3.1.2] | |
CPQ HE Temperature Sensor Health | temperature.sensor.status | CPQ Temperature Sensor Health | Monitors the temperature sensor condition. Possible values are 1- other: Temperature could not be determined,2- ok: The temperature sensor is within normal operating range,3- degraded: The temperature sensor is outside of normal operating range,4- failed: The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results.[OIDs: 1.3.6.1.4.1.232.6.2.6.8.1.6,1.3.6.1.4.1.232.6.2.6.8.1.1,1.3.6.1.4.1.232.6.2.6.8.1.2] | |
CPQ Host CPU Utilization | cpu.usage | CPQ Host CPU Utilization | % | Monitors the The CPU utilization as a percentage of the theoretical maximum during the last five minutes. A value of -1 indicates that no CPU utilization information is available for this processor.[OID: 1.3.6.1.4.1.232.11.2.3.1.1.3,1.3.6.1.4.1.232.11.2.3.1.1.1] |
CPQ SE CPU Status | cpu.health | CPQ CPU Status | The status of the processor. Possible values are 1- Unknown: The status of the CPU could not be determined,2- OK: The CPU is functioning normally,3- Degraded: The CPU is in a pre-failure warrantee state,4- Failed: The CPU is in a failed state,5- Disabled: The CPU has been disabled during power-on-self-test.[OIDs: 1.3.6.1.4.1.232.1.2.2.1.1.3,1.3.6.1.4.1.232.1.2.2.1.1.6] |
HPE Switch - Performance
Description
Monitors the Hpe Switch Performance Statistics like CPU Utilization per Process, Overall CPU Process Utilization, Memory Utilization.[HP-SWITCHING-MIB :: agentSwitchCpuProcessPercentageUtilization : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.8.1.3, agentSwitchCpuProcessTotalUtilization : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.9.0].Validated on HPE OfficeConnect Switch 1920S 24G 2SFP JL381A, PD.01.05, sysObjectId: 1.3.6.1.4.1.11.2.3.7.11.184.
Prerequisites
Device must have support for HP-SWITCHING-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Hpe Switch Memory Utilization | hpe_switch_MemoryUtilization | Hpe Switch Memory Utilization | % | Monitors the HPE switch memory utilization.[HP-SWITCHING-MIB :: agentSwitchCpuProcessMemFree : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.1.0, agentSwitchCpuProcessMemAvailable : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.2.0] |
Hpe Switch CPU Process Utilization | hpe_switch_CpuProcessPercentageUtilization | Hpe Switch Cpu Process Utilization | % | Monitors the CPU utilization per process in Percentage.[HP-SWITCHING-MIB :: agentSwitchCpuProcessPercentageUtilization : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.8.1.3] |
Hpe Switch Overall CPU Process Utilization | hpe_switch_CpuProcessTotalUtilization | Hpe Switch Overall CPU Process Utilization | % | Monitors the overall CPU process utilization in percentage.[HP-SWITCHING-MIB :: agentSwitchCpuProcessTotalUtilization : 1.3.6.1.4.1.11.5.7.5.7.1.1.1.1.4.9.0] |
HPE Switch - Hardware
Description
Monitors the Hpe Switch Hardware Statistics like Speed and Status of the Fan, Temperature value and State of Temperature Sensor, Temperature Unit State, Status of Power Supply.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesFanItemState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.6.1.3, boxServicesFanSpeed : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.6.1.4, boxServicesPowSupplyItemState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.7.1.3, boxServicesTempSensorState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.8.1.4, boxServicesTempSensorTemperature : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.8.1.5, boxServicesTempUnitState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.15.1.2].Validated on HPE OfficeConnect Switch 1920S 24G 2SFP JL381A, PD.01.05, sysObjectId: 1.3.6.1.4.1.11.2.3.7.11.184. Note: This HPE OfficeConnect Switch supports only power supply component.
Prerequisites
Device must have support for HP-BOXSERVICES-PRIVATE-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Hpe Switch - Fan | hpe_switch_FanState | Hpe Switch Fan State | Monitors the status of fan.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesFanItemState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.6.1.3].Possible values are notpresent(1), operational(2), failed(3), powering(4), nopower(5), notpowering(6), incompatible(7). | |
hpe_switch_FanSpeed | Hpe Switch Fan Speed | rpm | Monitors the speed of fan.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesFanSpeed : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.6.1.4] | |
Hpe Switch - Power Supply | hpe_switch_PowerSupplyState | Hpe Switch Power Supply State | Monitors the status of power supply.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesPowSupplyItemState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.7.1.3].Possible values are notpresent(1), operational(2), failed(3), powering(4), nopower(5), notpowering(6), incompatible(7). | |
Hpe Switch - Temperature Sensor | hpe_switch_TempSensorState | Hpe Switch Temp Sensor State | Monitors the state of temperature sensor.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesTempSensorState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.8.1.4].Possible values are low(0), normal(1), warning(2), critical(3), shutdown(4), notpresent(5), notoperational(6). | |
hpe_switch_TemperatureSensorValue | Hpe Switch Temperature Sensor Value | Celsius | Monitor the temperature value reported by sensor.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesTempSensorTemperature : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.8.1.5] | |
Hpe Switch - Temperature Unit State | hpe_switch_TempUnitState | Hpe Switch Temp Unit State | Monitors the temperature state of the unit.[HP-BOXSERVICES-PRIVATE-MIB :: boxServicesTempUnitState : 1.3.6.1.4.1.11.5.7.5.7.1.1.43.1.15.1.2].Possible values are low(0), normal(1), warning(2), critical(3), shutdown(4), notpresent(5), notoperational(6). |
HP-Unix System Performance
Description
It monitors HP-Unix System Performance parameters like CPU load,File System Used,File System Free,File System Utilization,Physical Memory Used,Physical Memory Free,Physical Memory Utilization and uptime.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HP-Unix CPU Load | hp.unix.sys.cpu.load.avg.5min | CPU Load 5min | It monitors average number of jobs in the last 5 minutes.[computerSystemAvgJobs5 - 1.3.6.1.4.1.11.2.3.1.1.4.0] | |
HP-Unix File System | hp.unix.file.system.used | Fle System Used | Bytes | It monitors the HP-Unix File System used space.[HP-UNIX::fileSystemDir - 1.3.6.1.4.1.11.2.3.1.2.2.1.10,fileSystemBsize - 1.3.6.1.4.1.11.2.3.1.2.2.1.7,fileSystemBlock - 1.3.6.1.4.1.11.2.3.1.2.2.1.4,fileSystemBfree - 1.3.6.1.4.1.11.2.3.1.2.2.1.5] |
hp.unix.file.system.utilization | Fle System Utilization | % | It monitors the HP-Unix File System utilization.[HP-UNIX::fileSystemDir - 1.3.6.1.4.1.11.2.3.1.2.2.1.10,fileSystemBsize - 1.3.6.1.4.1.11.2.3.1.2.2.1.7,fileSystemBlock - 1.3.6.1.4.1.11.2.3.1.2.2.1.4,fileSystemBfree - 1.3.6.1.4.1.11.2.3.1.2.2.1.5] | |
hp.unix.file.system.free | File System Free | Bytes | It monitors the HP-Unix File System free space.[HP-UNIX::fileSystemDir - 1.3.6.1.4.1.11.2.3.1.2.2.1.10,fileSystemBsize - 1.3.6.1.4.1.11.2.3.1.2.2.1.7,fileSystemBfree - 1.3.6.1.4.1.11.2.3.1.2.2.1.5] | |
HP-Unix Physical Memory | hp.unix.sys.memory.utilization | Memory Utilization | % | It monitors HP-Unix Physical memory utilization in %.[computerSystemFreeMemory - 1.3.6.1.4.1.11.2.3.1.1.7.0,computerSystemPhysMemory - 1.3.6.1.4.1.11.2.3.1.1.8.0] |
hp.unix.sys.memory.used | Memory Used | MB | It monitors HP-Unix Physical Memory used.[computerSystemFreeMemory - 1.3.6.1.4.1.11.2.3.1.1.7.0,computerSystemPhysMemory - 1.3.6.1.4.1.11.2.3.1.1.8.0] | |
hp.unix.sys.memory.free | Memory Free | MB | It monitors HP-Unix Physical Memory free.[computerSystemFreeMemory - 1.3.6.1.4.1.11.2.3.1.1.7.0] | |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
HPE Intelligent PDU (iPDU)
Description
Template to monitor HP Intelligent Modular PDU . Validated on AF520A(HP INTELLIGENT MOD PDU 24A NA/JPN). Firmware version 2.0.51.12
Prerequisites
The device should have support for CPQPOWER-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HPE Intelligent PDU (iPDU) | hpe.ipdu.total.power.watts | Total Power (Watts) | W | It monitors the total power for the whole iPDU in Watts.[CPQPOWER-MIB::mpduTotalPowerWatt:1.3.6.1.4.1.232.165.5.1.2.1.38]. |
hpe.ipdu.total.power.va | Total Power (VA) | It monitors the total power for the whole iPDU in VA.[CPQPOWER-MIB::mpduTotalPowerVA:1.3.6.1.4.1.232.165.5.1.2.1.39]. | ||
hpe.ipdu.total.percent.load | Total Percent Load | % | It monitors the whole iPDU's load in percent of rated capacity.[CPQPOWER-MIB::mpduTotalPercentLoad:1.3.6.1.4.1.232.165.5.1.2.1.40]. | |
hpe.ipdu.output.status | Output Status | It monitors the overall status of the device.Possible values are on : 1,off : 0,problem : 2.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputStatus:1.3.6.1.4.1.232.165.5.2.1.1.2]. | ||
hpe.ipdu.output.percent.load | Output Percent Load | % | It monitors the PDU's each output load in percent of rated capacity.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputPercentLoad:1.3.6.1.4.1.232.165.5.2.1.1.5]. | |
hpe.ipdu.output.voltage | Output Voltage | v | It monitors the measured output voltage from the PDU meters in volts.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputVoltage:1.3.6.1.4.1.232.165.5.2.1.1.6]. | |
hpe.ipdu.output.current | Output Current | amps | It monitors the measured output current from the PDU meters in amps.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputCurrent:1.3.6.1.4.1.232.165.5.2.1.1.7]. | |
hpe.ipdu.output.power.va | Output Power (VA) | It monitors the total VA load (VI) measured on the PDU in VA.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputPowerVA:1.3.6.1.4.1.232.165.5.2.1.1.8]. | ||
hpe.ipdu.output.power.watts | Output Power (Watts) | W | It monitors the total power load measured on the PDU in Watts.Component or instance is represented as Index of PDU and output index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduOutputPowerWatt:1.3.6.1.4.1.232.165.5.2.1.1.9]. | |
hpe.ipdu.smart.ext.bar.outlet.voltage | Smart Ext Bar Outlet Voltage | v | It monitors the Smart Ext Bar voltage in volts.Component or instance is represented as Index of PDU,output index of PDU and Smart Ext Bar outlet index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduSmExtBarOutletVoltage:1.3.6.1.4.1.232.165.5.4.1.1.5]. | |
hpe.ipdu.smart.ext.bar.outlet.current | Smart Ext Bar Outlet Current | amps | It monitors the Smart Ext Bar current draw in Amps.Component or instance is represented as Index of PDU,output index of PDU and Smart Ext Bar outlet index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduSmExtBarOutletCurrent:1.3.6.1.4.1.232.165.5.4.1.1.6]. | |
hpe.ipdu.smart.ext.bar.outlet.power.watts | Smart Ext Bar Outlet Power (Watts) | W | It monitors the Smart Ext Bar's Power measured in Watts.Component or instance is represented as Index of PDU,output index of PDU and Smart Ext Bar outlet index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduSmExtBarOutletPowerWatt:1.3.6.1.4.1.232.165.5.4.1.1.7]. | |
hpe.ipdu.smart.ext.bar.outlet.status | Smart Ext Bar Outlet Status | It monitors the overall status of the Smart Extension Bar's outlet.Possible Values are on : 1,off : 0,problem : 2.Component or instance is represented as Index of PDU,output index of PDU and Smart Ext Bar outlet index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduSmExtBarOutletStatus:1.3.6.1.4.1.232.165.5.4.1.1.2]. | ||
hpe.ipdu.device.status | Device Status | It monitors the overall status of the device.Possible values are on : 1,off : 0,problem : 2.If component name not detected then component will be in format of : Index of PDU and device index of PDU with dotted notation in graph and alert.[CPQPOWER-MIB::mpduDeviceStatus:1.3.6.1.4.1.232.165.5.3.1.1.2]. |
HPE PDU3
Description
Template to monitor HPE PDU3 parameters like Status,Input Frequency (Hz),Input Frequency Status,Input Power (VA),Input Power (Watts),Input Phase Voltage,Input Phase Voltage Status,Input Phase Current,Input Phase Current Status,Input Phase Power (VA),Input Phase Power (Watts),Group Voltage,Group Voltage Status,Group Current,Group Current Status,Group Current Percent Load,Group Power (VA),Group Power (Watts),Temperature,Temperature Status,Humidity,Humidity Status,Outlet Current,Outlet Active Power Status,Outlet Current Percent Load,Outlet Power (VA),Outlet Power (Watts). Enterprise OID : 1.3.6.1.4.1.232.165.11. CPQPOWER-MIB
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
HPE PDU3 - Group | hpe.pdu3.group.current | Group Current | It monitors group current measurement value.[CPQPOWER-MIB::pdu3GroupCurrent:1.3.6.1.4.1.232.165.11.3.1.1.12]. | |
hpe.pdu3.group.power.va | Group Power (VA) | It monitors the group VA value.[CPQPOWER-MIB::pdu3GroupPowerVA:1.3.6.1.4.1.232.165.11.3.1.1.19]. | ||
hpe.pdu3.group.current.percent.load | Group Current Percent Load | % | It monitors the current percent load,based on the rated current capacity.[CPQPOWER-MIB::pdu3GroupCurrentPercentLoad:1.3.6.1.4.1.232.165.11.3.1.1.18]. | |
hpe.pdu3.group.power.watts | Group Power (Watts) | W | It monitors the group power value in watts.[CPQPOWER-MIB::pdu3GroupPowerWatts:1.3.6.1.4.1.232.165.11.3.1.1.20]. | |
hpe.pdu3.group.voltage.status | Group Voltage Status | It monitors status of the measured group voltage relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.[CPQPOWER-MIB::pdu3GroupVoltageThStatus:1.3.6.1.4.1.232.165.11.3.1.1.6]. | ||
hpe.pdu3.group.current.status | Group Current Status | It monitors status of the measured group current relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.[CPQPOWER-MIB::pdu3GroupCurrentThStatus:1.3.6.1.4.1.232.165.11.3.1.1.13]. | ||
hpe.pdu3.group.voltage | Group Voltage | v | It monitors the PDU3 Group Voltage.[CPQPOWER-MIB::pdu3GroupVoltage:1.3.6.1.4.1.232.165.11.3.1.1.5]. | |
HPE PDU3 - Humidity | hpe.pdu3.humidity | Humidity (%RH) | It monitors the PDU3 humidity.[CPQPOWER-MIB::pdu3HumidityValue:1.3.6.1.4.1.232.165.11.4.3.1.4]. | |
hpe.pdu3.humidity.status | Humidity Status | It monitors the status of the measured humidity relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical [CPQPOWER-MIB::pdu3HumidityThStatus:1.3.6.1.4.1.232.165.11.4.3.1.5]. | ||
HPE PDU3 - Input | hpe.pdu3.input.frequency | Input Frequency (Hz) | It monitors the measured input frequency from the PDU meters in Hz.[CPQPOWER-MIB::pdu3InputFrequency1.3.6.1.4.1.232.165.11.2.1.1.2]. | |
hpe.pdu3.input.power.watts | Input Power (Watts) | W | It monitors the total input Watts of all phases.[CPQPOWER-MIB::pdu3InputPowerWatts:1.3.6.1.4.1.232.165.11.2.1.1.5]. | |
hpe.pdu3.input.frequency.status | Input Frequency Status | It monitors the status of the measured input frequency relative to the nominal frequency and the admitted tolerance.Possible values are 0:unknown,1: good,2: outOfRange.[CPQPOWER-MIB::pdu3InputFrequencyStatus:1.3.6.1.4.1.232.165.11.2.1.1.3]. | ||
hpe.pdu3.input.power.va | Input Power (VA) | It monitors the total input VA of all phases.[CPQPOWER-MIB::pdu3InputPowerVA:1.3.6.1.4.1.232.165.11.2.1.1.4]. | ||
HPE PDU3 - Input Phase | hpe.pdu3.input.phase.power.watts | PDU3 Input Phase Power (Watts) | W | It monitors the input Watts value.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhasePowerWatts:1.3.6.1.4.1.232.165.11.2.2.1.20]. |
hpe.pdu3.input.phase.current.status | Input Phase Current Status | It monitors the status of the measured input current relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhaseCurrentThStatus:1.3.6.1.4.1.232.165.11.2.2.1.12]. | ||
hpe.pdu3.input.phase.voltage | Input Phase Voltage | It monitors the input voltage measurement value.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhaseVoltage:1.3.6.1.4.1.232.165.11.2.2.1.3]. | ||
hpe.pdu3.input.phase.voltage.status | Input Phase Voltage Status | It monitors the status of the measured input voltage relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhaseVoltageThStatus:1.3.6.1.4.1.232.165.11.2.2.1.4]. | ||
hpe.pdu3.input.phase.power.va | Input Phase Power (VA) | It monitors the input VA value.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhasePowerVA:1.3.6.1.4.1.232.165.11.2.2.1.19]. | ||
hpe.pdu3.input.phase.current | Input Phase Current | It monitors the input current measurement value.Component or instance is represented as Index of PDU3 and input phase index of PDU3 with dotted notation in graph and alert.[CPQPOWER-MIB::pdu3InputPhaseCurrent:1.3.6.1.4.1.232.165.11.2.2.1.11]. | ||
HPE PDU3 - Outlet | hpe.pdu3.outlet.active.power.status | Outlet Active Power Status | It monitors the status of the measured outlet active power relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.[CPQPOWER-MIB::pdu3OutletActivePowerThStatus:1.3.6.1.4.1.232.165.11.5.1.1.6]. | |
hpe.pdu3.outlet.power.watts | Outlet Active Power Status | It monitors the status of the measured outlet active power relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.[CPQPOWER-MIB::pdu3OutletActivePowerThStatus:1.3.6.1.4.1.232.165.11.5.1.1.6]. | ||
hpe.pdu3.outlet.current.percent.load | Outlet Current Percent Load | % | It monitors the current percent load,based on the rated current capacity.[CPQPOWER-MIB::pdu3OutletCurrentPercentLoad:1.3.6.1.4.1.232.165.11.5.1.1.11]. | |
hpe.pdu3.outlet.current | Outlet Current | amps | It monitors the outlet current measurement value.[CPQPOWER-MIB::pdu3OutletCurrent:1.3.6.1.4.1.232.165.11.5.1.1.5]. | |
hpe.pdu3.outlet.power.va | Outlet Power (VA) | It monitors the outlet power VA value.[CPQPOWER-MIB::pdu3OutletVA:1.3.6.1.4.1.232.165.11.5.1.1.12]. | ||
HPE PDU3 - Status | hpe.pdu3.status | PDU3 Status | It monitors the overall status of the device. Possible values are 0:unknown,1: other,2: ok,3: degraded,4: failed.[CPQPOWER-MIB::pdu3Status:1.3.6.1.4.1.232.165.11.1.2.1.9,pdu3SerialNumber:1.3.6.1.4.1.232.165.11.1.2.1.8]. | |
HPE PDU3 - Temperature | hpe.pdu3.temperature | Temperature | It monitors the PDU3 Temperature.[CPQPOWER-MIB::pdu3TemperatureValue:1.3.6.1.4.1.232.165.11.4.2.1.4]. | |
hpe.pdu3.temperature.status | Temperature Status | It monitors the status of the measured temperature relative to the configured thresholds.Possible values are 0:unknown,1: good,2: lowWarning,3: lowCritical,4: highWarning,5: highCritical.[CPQPOWER-MIB::pdu3TemperatureThStatus:1.3.6.1.4.1.232.165.11.4.2.1.5]. |