Eltek eNexus - Battery
Description
Monitors the Eltek eNexus battery and battery group2 parameters like Battery Group2 Voltage Status,Battery Group2 Voltage Value,Battery Group2 Currents Status,Battery Group2 Currents Value,Battery Group2 Temperatures Status,Battery Group2 Temperatures Value,BatteryGroup2 Time Left Status,Battery Group2 Time Left Value,Battery Group2 Remaining Capacity Status,Battery Group2 Remaining Capacity Value,Battery Group2 Used Capacity Status,Battery Group2 Used Capacity Value,Battery Group2 Total Capacity Status,Battery Group2 Total Capacity Value,Battery Group2 Quality Status,Battery Group2 Quality Value,Battery Group2 LVBD Status,Battery Group2 LVBD Value,Battery Group2 Charge Current Limit Value,Battery Group2 Bank Status,Battery Group2 Equalize Voltage,Battery Group2 Ah Charged Status,Battery Group2 Ah Charged Value,Battery Group2 Ah Discharged Status,Battery Group2 Ah Discharged Value,Monitors the Eltek eNexus battery parameters like Battery Voltage Status,Battery Voltage Value,Battery Currents Status,Battery Currents Value,Battery Temperatures Status,Battery Temperatures Value,Battery Time Left Status,Battery Time Left Value,Battery Remaining Capacity Status,Battery Remaining Capacity Value,Battery Used Capacity Status,Battery Used Capacity Value,Battery Total Capacity Status,Battery Total Capacity Value,Battery Quality Status,Battery Quality Value,Battery LVBD Status,Battery LVBD Value,Battery Charge Current Limit Value,Battery Ah Charged Status,Battery Ah Charged Value,Battery Ah Discharged Status,Battery Ah Discharged Value.[SP2-MIB :: batteryGroup2VoltageStatus : 1.3.6.1.4.1.12148.10.15.5.1.0,batteryGroup2VoltageValue : 1.3.6.1.4.1.12148.10.15.5.5.0,batteryGroup2CurrentsStatus : 1.3.6.1.4.1.12148.10.15.6.1.0,batteryGroup2CurrentsValue : 1.3.6.1.4.1.12148.10.15.6.5.0,batteryGroup2TemperaturesStatus : 1.3.6.1.4.1.12148.10.15.7.1.0,batteryGroup2TemperaturesValue : 1.3.6.1.4.1.12148.10.15.7.5.0,batteryGroup2TimeLeftStatus : 1.3.6.1.4.1.12148.10.15.8.1.0,batteryGroup2TimeLeftValue : 1.3.6.1.4.1.12148.10.15.8.5.0,batteryGroup2RemainingCapacityStatus : 1.3.6.1.4.1.12148.10.15.9.1.0,batteryGroup2RemainingCapacityValue : 1.3.6.1.4.1.12148.10.15.9.5.0,batteryGroup2UsedCapacityStatus : 1.3.6.1.4.1.12148.10.15.10.1.0,batteryGroup2UsedCapacityValue : 1.3.6.1.4.1.12148.10.15.10.5.0,batteryGroup2TotalCapacityStatus : 1.3.6.1.4.1.12148.10.15.11.1.0,batteryGroup2TotalCapacityValue : 1.3.6.1.4.1.12148.10.15.11.5.0,batteryGroup2QualityStatus : 1.3.6.1.4.1.12148.10.15.12.1.0,batteryGroup2QualityValue : 1.3.6.1.4.1.12148.10.15.12.5.0,batteryGroup2LVBDStatus : 1.3.6.1.4.1.12148.10.15.13.1.0,batteryGroup2LVBDValue : 1.3.6.1.4.1.12148.10.15.13.5.0,batteryGroup2ChargeCurrentLimitValue : 1.3.6.1.4.1.12148.10.15.14.2.0,batteryGroup2BankStatus : 1.3.6.1.4.1.12148.10.15.18.1.0,batteryGroup2EqualizeVoltage : 1.3.6.1.4.1.12148.10.15.21.1.0,batteryGroup2AhChargedStatus : 1.3.6.1.4.1.12148.10.15.22.1.0,batteryGroup2AhChargedValue : 1.3.6.1.4.1.12148.10.15.22.5.0,batteryGroup2AhDischargedStatus : 1.3.6.1.4.1.12148.10.15.23.1.0,batteryGroup2AhDischargedValue : 1.3.6.1.4.1.12148.10.15.23.5.0,batteryVoltageStatus : 1.3.6.1.4.1.12148.10.10.5.1.0,batteryVoltageValue : 1.3.6.1.4.1.12148.10.10.5.5.0,batteryCurrentsStatus : 1.3.6.1.4.1.12148.10.10.6.1.0,batteryCurrentsValue : 1.3.6.1.4.1.12148.10.10.6.5.0,batteryTemperaturesStatus : 1.3.6.1.4.1.12148.10.10.7.1.0,batteryTemperaturesValue : 1.3.6.1.4.1.12148.10.10.7.5.0,batteryTimeLeftStatus : 1.3.6.1.4.1.12148.10.10.8.1.0,batteryTimeLeftValue : 1.3.6.1.4.1.12148.10.10.8.5.0,batteryRemainingCapacityStatus : 1.3.6.1.4.1.12148.10.10.9.1.0,batteryRemainingCapacityValue : 1.3.6.1.4.1.12148.10.10.9.5.0,batteryUsedCapacityStatus : 1.3.6.1.4.1.12148.10.10.10.1.0,batteryUsedCapacityValue : 1.3.6.1.4.1.12148.10.10.10.5.0,batteryTotalCapacityStatus : 1.3.6.1.4.1.12148.10.10.11.1.0,batteryTotalCapacityValue : 1.3.6.1.4.1.12148.10.10.11.5.0,batteryQualityStatus : 1.3.6.1.4.1.12148.10.10.12.1.0,batteryQualityValue : 1.3.6.1.4.1.12148.10.10.12.5.0,batteryLVBDStatus : 1.3.6.1.4.1.12148.10.10.13.1.0,batteryLVBDValue : 1.3.6.1.4.1.12148.10.10.13.5.0,batteryChargeCurrentLimitValue : 1.3.6.1.4.1.12148.10.10.14.2.0,batteryAhChargedStatus : 1.3.6.1.4.1.12148.10.10.23.1.0,batteryAhChargedValue : 1.3.6.1.4.1.12148.10.10.23.5.0,batteryAhDischargedStatus : 1.3.6.1.4.1.12148.10.10.24.1.0,batteryAhDischargedValue : 1.3.6.1.4.1.12148.10.10.24.5.0]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Battery | eltek_eNexus_battery_BatteryAhDischargedValue | Eltek eNexus Battery Ah Discharged Value | amps | Monitors the calculated battery ah (x100) discharged value.[SP2-MIB :: batteryAhDischargedValue : 1.3.6.1.4.1.12148.10.10.24.5.0] |
eltek_eNexus_battery_BatteryTotalCapacityStatus | Eltek eNexus Battery Total Capacity Status | Monitors the status of the total capacity monitor.[SP2-MIB :: batteryTotalCapacityStatus : 1.3.6.1.4.1.12148.10.10.11.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_battery_BatteryAhChargedValue | Eltek eNexus Battery Ah Charged Value | amps | Monitors the calculated battery ah (x100) charged value.[SP2-MIB :: batteryAhChargedValue : 1.3.6.1.4.1.12148.10.10.23.5.0] | |
eltek_eNexus_battery_BatteryVoltageValue | Eltek eNexus Battery Voltage Value | v | Monitors the value of the measured battery voltage.[SP2-MIB :: batteryVoltageValue : 1.3.6.1.4.1.12148.10.10.5.5.0]. | |
eltek_eNexus_battery_BatteryUsedCapacityStatus | Eltek eNexus Battery Used Capacity Status | Monitors the status of the battery used capacity (DoD) monitor.[SP2-MIB :: batteryUsedCapacityStatus : 1.3.6.1.4.1.12148.10.10.10.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_battery_BatteryCurrentsValue | Eltek eNexus Battery Currents Value | amps | Monitors the measured total battery current.[SP2-MIB :: batteryCurrentsValue : 1.3.6.1.4.1.12148.10.10.6.5.0] | |
eltek_eNexus_battery_BatteryUsedCapacityValue | Eltek eNexus Battery Used Capacity Value | amps | Monitors the estimated battery used capacity (DoD).[SP2-MIB :: batteryUsedCapacityValue : 1.3.6.1.4.1.12148.10.10.10.5.0.] | |
eltek_eNexus_battery_BatteryRemainingCapacityValue | Eltek eNexus Battery Remaining Capacity Value | amps | Monitors the Battery remaining capacity (SOC) value.[SP2-MIB :: batteryRemainingCapacityValue : 1.3.6.1.4.1.12148.10.10.9.5.0] | |
eltek_eNexus_battery_BatteryChargeCurrentLimitValue | Eltek eNexus Battery Charge Current Limit Value | amps | Monitors the Battery charging current limit value.[SP2-MIB :: batteryChargeCurrentLimitValue : 1.3.6.1.4.1.12148.10.10.14.2.0] | |
eltek_eNexus_battery_BatteryTimeLeftValue | Eltek eNexus Battery Time Left Value | m | Monitors the estimated value of battery remaining backup time.[SP2-MIB :: batteryTimeLeftValue : 1.3.6.1.4.1.12148.10.10.8.5.0] | |
eltek_eNexus_battery_BatteryLVBDValue | Eltek eNexus Battery LVBD Value | Monitors the measured value of the LVBD.[SP2-MIB :: batteryLVBDValue : 1.3.6.1.4.1.12148.10.10.13.5.0]. | ||
eltek_eNexus_battery_BatteryVoltageStatus | Eltek eNexus Battery Voltage Status | monitors the status of the measured battery voltage.[SP2-MIB :: batteryVoltageStatus : 1.3.6.1.4.1.12148.10.10.5.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_battery_BatteryTemperaturesValue | Eltek eNexus Battery Temperatures Value | F | Monitors the highest value of the enabled battery temperature measurements.[SP2-MIB :: batteryTemperaturesValue : 1.3.6.1.4.1.12148.10.10.7.5.0] | |
eltek_eNexus_battery_BatteryCurrentsStatus | Eltek eNexus Battery Currents Status | Monitors the status of the measured battery current.[SP2-MIB :: batteryCurrentsStatus : 1.3.6.1.4.1.12148.10.10.6.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) . | ||
eltek_eNexus_battery_BatteryTimeLeftStatus | Eltek eNexus Battery Time Left Status | monitors the status of the estimated battery remaining backup time.[SP2-MIB :: batteryTimeLeftStatus : 1.3.6.1.4.1.12148.10.10.8.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_battery_BatteryTemperaturesStatus | Eltek eNexus Battery Temperatures Status | Monitors the state of the battery fuses/breakers.[SP2-MIB :: batteryTemperaturesStatus : 1.3.6.1.4.1.12148.10.10.7.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_battery_BatteryTotalCapacityValue | Eltek eNexus Battery Total Capacity Value | amps | Monitors the estimated total battery capacity (installed Ah - SoH) value.[SP2-MIB :: batteryTotalCapacityValue : 1.3.6.1.4.1.12148.10.10.11.5.0] | |
eltek_eNexus_battery_BatteryRemainingCapacityStatus | Eltek eNexus Battery Remaining Capacity Status | Monitors the status of the battery remaining capacity monitor.[SP2-MIB :: batteryRemainingCapacityStatus : 1.3.6.1.4.1.12148.10.10.9.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_battery_BatteryQualityValue | Eltek eNexus Battery Quality Value | % | Monitors the calculated battery quality (SoH).[SP2-MIB :: batteryQualityValue : 1.3.6.1.4.1.12148.10.10.12.5.0]. | |
Eltek eNexus - Battery Group2 | eltek_eNexus_BatteryGroup2ChargeCurrentLimitValue | Eltek eNexus Battery Group2 Charge Current Limit Value | amps | Monitors the battery charging current limit value.[SP2-MIB :: batteryGroup2ChargeCurrentLimitValue : 1.3.6.1.4.1.12148.10.15.14.2.0]. |
eltek_eNexus_BatteryGroup2UsedCapacityStatus | Eltek eNexus Battery Group2 Used Capacity Status | Monitors the status of the battery used capacity (DoD) monitor.[SP2-MIB :: batteryGroup2UsedCapacityStatus : 1.3.6.1.4.1.12148.10.15.10.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_BatteryGroup2QualityStatus | Eltek eNexus Battery Group2 Quality Status | Monitors the status of the battery quality (SoH) monitor.[SP2-MIB :: batteryGroup2QualityStatus : 1.3.6.1.4.1.12148.10.15.12.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) . | ||
eltek_eNexus_BatteryGroup2EqualizeVoltage | Eltek eNexus Battery Group2 Equalize Voltage | v | Monitors the Voltage at which the DC System equalize charges the batteries.[SP2-MIB :: batteryGroup2EqualizeVoltage : 1.3.6.1.4.1.12148.10.15.21.1.0] | |
eltek_eNexus_BatteryGroup2AhDischargedValue | Eltek eNexus Battery Group2 Ah Discharged Value | amps | Monitors the status of the battery ah discharged monitor.[SP2-MIB :: batteryGroup2AhDischargedValue : 1.3.6.1.4.1.12148.10.15.23.5.0] | |
eltek_eNexus_BatteryGroup2AhChargedValue | Eltek eNexus Battery Group2 Ah Charged Value | amps | Monitors the calculated battery ah (x100) charged value.[SP2-MIB :: batteryGroup2AhChargedValue : 1.3.6.1.4.1.12148.10.15.22.5.0] | |
eltek_eNexus_BatteryGroup2TimeLeftStatus | Eltek eNexus BatteryGroup2 Time Left Status | Monitors the status of the estimated battery remaining backup time.[SP2-MIB :: batteryGroup2TimeLeftStatus : 1.3.6.1.4.1.12148.10.15.8.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) . | ||
eltek_eNexus_BatteryGroup2AhDischargedStatus | Eltek eNexus Battery Group2 Ah Discharged Status | Monitors the status of the battery ah discharged monitor.[SP2-MIB :: batteryGroup2AhDischargedStatus : 1.3.6.1.4.1.12148.10.15.23.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_BatteryGroup2QualityValue | Eltek eNexus Battery Group2 Quality Value | % | Monitors the calculated battery quality (SoH) based on the latest battery test.[SP2-MIB :: batteryGroup2QualityValue : 1.3.6.1.4.1.12148.10.15.12.5.0] | |
eltek_eNexus_BatteryGroup2VoltageValue | Eltek eNexus Battery Group2 Voltage Value | v | Monitors the value of the measured battery voltage.[SP2-MIB :: batteryGroup2VoltageValue : 1.3.6.1.4.1.12148.10.10.5.5.0] | |
eltek_eNexus_BatteryGroup2TotalCapacityStatus | Eltek eNexus Battery Group2 Total Capacity Status | Monitors the status of the total capacity monitor.[SP2-MIB :: batteryGroup2TotalCapacityStatus : 1.3.6.1.4.1.12148.10.15.11.1.0] | ||
eltek_eNexus_BatteryGroup2TemperaturesStatus | Eltek eNexus Battery Group2 Temperatures Status | Monitors the state of the battery fuses/breakers can be either one of the defined enumerated values.[SP2-MIB :: batteryGroup2TemperaturesStatus : 1.3.6.1.4.1.12148.10.15.7.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_BatteryGroup2TemperaturesValue | Eltek eNexus Battery Group2 Temperatures Value | F | Monitors the highest value of the enabled battery temperature.[SP2-MIB :: batteryGroup2TemperaturesValue : 1.3.6.1.4.1.12148.10.15.7.5.0] | |
eltek_eNexus_BatteryGroup2TotalCapacityValue | Eltek eNexus Battery Group2 Total Capacity Value | amps | Monitors the estimated total battery capacity (installed Ah - SoH) value.[SP2-MIB :: batteryGroup2TotalCapacityValue : 1.3.6.1.4.1.12148.10.15.11.5.0] | |
eltek_eNexus_BatteryGroup2RemainingCapacityValue | Eltek eNexus Battery Group2 Remaining Capacity Value | amps | Monitors the Battery remaining capacity (SOC) value estimated from the latest battery test result.[SP2-MIB :: batteryGroup2RemainingCapacityValue : 1.3.6.1.4.1.12148.10.15.9.5.0] | |
eltek_eNexus_BatteryGroup2CurrentsStatus | Eltek eNexus Battery Group2 Currents Status | Monitors the status of the measured battery current.[SP2-MIB :: batteryGroup2CurrentsStatus : 1.3.6.1.4.1.12148.10.10.6.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_BatteryGroup2AhChargedStatus | Eltek eNexus Battery Group2 Ah Charged Status | Monitors the status of the battery ah charged monitor.[SP2-MIB :: batteryGroup2AhChargedStatus : 1.3.6.1.4.1.12148.10.15.22.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_BatteryGroup2LVBDStatus | Eltek eNexus Battery Group2 LVBD Status | Monitors whether the Battery Contactor is connected,disconnected,disabled.[SP2-MIB :: batteryGroup2LVBDStatus : 1.3.6.1.4.1.12148.10.15.13.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_BatteryGroup2BankStatus | Eltek eNexus Battery Group2 Bank Status | Monitors the overall status of battery bank.[SP2-MIB :: batteryGroup2BankStatus : 1.3.6.1.4.1.12148.10.15.18.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_BatteryGroup2RemainingCapacityStatus | Eltek eNexus Battery Group2 Remaining Capacity Status | Monitors the status of the battery remaining capacity monitor.[SP2-MIB :: batteryGroup2RemainingCapacityStatus : 1.3.6.1.4.1.12148.10.15.9.1.0] | ||
eltek_eNexus_BatteryGroup2CurrentsValue | Eltek eNexus Battery Group2 Currents Value | amps | Monitors the measured total battery current.[SP2-MIB :: batteryGroup2CurrentsValue : 1.3.6.1.4.1.12148.10.15.6.5.0] | |
eltek_eNexus_BatteryGroup2LVBDValue | Eltek eNexus Battery Group2 LVBD Value | Monitors the measured value of the LVBD.[SP2-MIB :: batteryGroup2LVBDValue : 1.3.6.1.4.1.12148.10.15.13.5.0] | ||
eltek_eNexus_BatteryGroup2TimeLeftValue | Eltek eNexus Battery Group2 Time Left Value | m | Monitors the estimated value of battery remaining backup time.[SP2-MIB :: batteryGroup2TimeLeftValue : 1.3.6.1.4.1.12148.10.15.8.5.0] | |
eltek_eNexus_BatteryGroup2VoltageStatus | Eltek eNexus Battery Group2 Voltage Status | Monitors the status of the measured battery voltage.[SP2-MIB :: batteryGroup2VoltageStatus : 1.3.6.1.4.1.12148.10.10.5.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_BatteryGroup2UsedCapacityValue | Eltek eNexus Battery Group2 Used Capacity Value | amps | Monitors the estimated battery used capacity (DoD).[SP2-MIB :: batteryGroup2UsedCapacityValue : 1.3.6.1.4.1.12148.10.15.10.5.0] |
Eltek eNexus - DcDc
Description
Monitors the Eltek eNexus DcDc parameters like DcDc Capacity Status,DcDc Capacity Value,DcDc Error Status,DcDc Error Value,DcDc Current Status,DcDc Current Value,DcDc Group Status,DcDc Group Output Voltage.[SP2-MIB :: dcdcCapacityStatus : 1.3.6.1.4.1.12148.10.6.4.1.1,dcdcCapacityValue : 1.3.6.1.4.1.12148.10.6.4.1.5,dcdcErrorStatus : 1.3.6.1.4.1.12148.10.6.6.1.1,dcdcErrorValue : 1.3.6.1.4.1.12148.10.6.6.1.5,dcdcCurrentStatus : 1.3.6.1.4.1.12148.10.6.3.1.1,dcdcCurrentValue : 1.3.6.1.4.1.12148.10.6.3.1.5,dcdcGroupStatus : 1.3.6.1.4.1.12148.10.6.2.1.2,dcdcGroupOutputVoltage : 1.3.6.1.4.1.12148.10.6.2.1.4]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - DcDc Capacity | eltek_eNexus_dcdc_DcDcCapacityStatus | Eltek eNexus DcDc Capacity Status | Monitors the status of the measured used dcdc capacity.[SP2-MIB :: dcdcCapacityStatus : 1.3.6.1.4.1.12148.10.6.4.1.1].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | |
eltek_eNexus_dcdc_DcDcCapacityValue | Eltek eNexus DcDc Capacity Value | Monitors the used dcdc capacity value presented in percentage.[SP2-MIB :: dcdcCapacityValue : 1.3.6.1.4.1.12148.10.6.4.1.5] | ||
Eltek eNexus - DcDc Capacity Error | eltek_eNexus_dcdc_DcDcErrorStatus | Eltek eNexus DcDc Error Status | Monitor the status value shows if the number of failed units is higher than the defined alarm level.[SP2-MIB :: dcdcErrorStatus : 1.3.6.1.4.1.12148.10.6.6.1.1].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | |
eltek_eNexus_dcdc_DcDcErrorValue | Eltek eNexus DcDc Error Value | count | Monitors the number of failed dcdc converters.[SP2-MIB :: dcdcErrorValue : 1.3.6.1.4.1.12148.10.6.6.1.5]. | |
Eltek eNexus - DcDc Current | eltek_eNexus_dcdc_DcDcCurrentStatus | Eltek eNexus DcDc Current Status | Monitors the status of the measured total dcdc current.[SP2-MIB :: dcdcCurrentStatus : 1.3.6.1.4.1.12148.10.6.3.1.1].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | |
eltek_eNexus_dcdc_DcDcCurrentValue | Eltek eNexus DcDc Current Value | amps | Monitors the value of the measured total dcdc current.[SP2-MIB :: dcdcCurrentValue : 1.3.6.1.4.1.12148.10.6.3.1.5] | |
Eltek eNexus - DcDc Groups | eltek_eNexus_dcdc_DcDcGroupStatus | Eltek eNexus DcDc Group Status | Monitors the overall status of dcdc group.[SP2-MIB :: dcdcGroupStatus : 1.3.6.1.4.1.12148.10.6.2.1.2].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | |
eltek_eNexus_dcdc_DcDcGroupOutputVoltage | Eltek eNexus DcDc Group Output Voltage | v | Monitors the Output voltage of dcdc converters.[SP2-MIB :: dcdcGroupOutputVoltage : 1.3.6.1.4.1.12148.10.6.2.1.4] |
Eltek eNexus - Error
Description
Eltek eNexus failure parameters like Mains Mains Failure Value,Rectifiers Error Value,Solar Chargers Error Value,Wind Chargers Error Value,Main Control Units Error Value,Smart Node Error Value,Battery Monitor Error Value,Load Monitor Error Value,Io Unit Error Value,Flexi Monitor Error Value,User Suspended Value,Inverters Error Value,Grid Inverters Error Value,Rectiverters Error Value,Rectiverters Error Value,Generator Mains Delay.[SP2-MIB :: mainsMainsFailureValue : 1.3.6.1.4.1.12148.10.3.2.5.0,rectifiersErrorValue : 1.3.6.1.4.1.12148.10.5.4.5.0,solarChargersErrorValue : 1.3.6.1.4.1.12148.10.7.4.5.0,windChargersErrorValue : 1.3.6.1.4.1.12148.10.8.4.5.0,mainControlUnitsErrorValue : 1.3.6.1.4.1.12148.10.13.12.1.5.0,smartNodeErrorValue : 1.3.6.1.4.1.12148.10.13.12.2.5.0,batteryMonitorErrorValue : 1.3.6.1.4.1.12148.10.13.12.3.5.0,loadMonitorErrorValue : 1.3.6.1.4.1.12148.10.13.12.4.5.0,ioUnitErrorValue : 1.3.6.1.4.1.12148.10.13.12.5.5.0,flexiMonitorErrorValue : 1.3.6.1.4.1.12148.10.13.12.7.5.0,userSuspendedValue : 1.3.6.1.4.1.12148.10.13.15.5.0,invertersErrorValue : 1.3.6.1.4.1.12148.10.16.2.5.0,gridInvertersErrorValue : 1.3.6.1.4.1.12148.10.17.2.5.0,rectivertersErrorValue : 1.3.6.1.4.1.12148.10.18.3.5.0,generatorDischargeValue : 1.3.6.1.4.1.12148.10.4.4.0,generatorMainsDelay : 1.3.6.1.4.1.12148.10.4.5.0].
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Failures | eltek_eNexus_windchargers_WindChargersErrorValue | Eltek eNexus Wind Chargers Error Value | count | Monitors the number of failed wind chargers.[SP2-MIB :: windChargersErrorValue : 1.3.6.1.4.1.12148.10.8.4.5.0] |
eltek_eNexus_user_UserSuspendedValue | Eltek eNexus User Suspended Value | count | Monitors the detected number of failed attempts.[SP2-MIB :: userSuspendedValue : 1.3.6.1.4.1.12148.10.13.15.5.0] | |
eltek_eNexus_battery_BatteryMonitorErrorValue | Eltek eNexus Battery Monitor Error Value | count | Monitors the detected number of failed battery monitors.[SP2-MIB :: batteryMonitorErrorValue : 1.3.6.1.4.1.12148.10.13.12.3.5.0] | |
eltek_eNexus_load_LoadMonitorErrorValue | Eltek eNexus Load Monitor Error Value | count | Monitors the detected number of failed load monitors.[SP2-MIB :: loadMonitorErrorValue : 1.3.6.1.4.1.12148.10.13.12.4.5.0] | |
eltek_eNexus_inverters_InvertersErrorValue | Eltek eNexus Inverters Error Value | count | Monitors the number of failed inverters.[SP2-MIB :: invertersErrorValue : 1.3.6.1.4.1.12148.10.16.2.5.0] | |
eltek_eNexus_generator_GeneratorDischargeValue | Eltek eNexus Generator Discharge Value | % | Monitors the present discharge value in percentage.[SP2-MIB :: generatorDischargeValue : 1.3.6.1.4.1.12148.10.4.4.0] | |
eltek_eNexus_fleximonitor_FlexiMonitorErrorValue | Eltek eNexus Flexi Monitor Error Value | count | Monitors the detected number of failed flexi monitors.[SP2-MIB :: flexiMonitorErrorValue : 1.3.6.1.4.1.12148.10.13.12.7.5.0] | |
eltek_eNexus_rectiverters_RectivertersErrorValue | Eltek eNexus Rectiverters Error Value | count | Monitors the number of failed rectifiers.[SP2-MIB :: rectivertersErrorValue : 1.3.6.1.4.1.12148.10.18.3.5.0] | |
eltek_eNexus_gridInverters_GridInvertersErrorValue | Eltek eNexus Grid Inverters Error Value | count | Monitors the number of failed inverters.[SP2-MIB :: gridInvertersErrorValue : 1.3.6.1.4.1.12148.10.17.2.5.0] | |
eltek_eNexus_solarchargers_SolarChargersErrorValue | Eltek eNexus Solar Chargers Error Value | count | Monitors the number of failed solar chargers.[SP2-MIB :: solarChargersErrorValue : 1.3.6.1.4.1.12148.10.7.4.5.0] | |
eltek_eNexus_mains_MainsMainsFailureValue | Eltek eNexus Mains Mains Failure Value | count | Monitors the detected number of failed phases.[SP2-MIB :: mainsMainsFailureValue : 1.3.6.1.4.1.12148.10.3.2.5.0] | |
eltek_eNexus_rectifiers_RectifiersErrorValue | Eltek eNexus Rectifiers Error Value | count | Monitors the number of failed rectifiers.[SP2-MIB :: rectifiersErrorValue : 1.3.6.1.4.1.12148.10.5.4.5.0] | |
eltek_eNexus_generator_GeneratorMainsDelay | Eltek eNexus Generator Mains Delay | m | Monitors the elapsing time of mains failure.[SP2-MIB :: generatorMainsDelay : 1.3.6.1.4.1.12148.10.4.5.0] | |
eltek_eNexus_smartnode_SmartNodeErrorValue | Eltek eNexus Smart Node Error Value | count | Monitors the detected number of failed smartnodes.[SP2-MIB :: smartNodeErrorValue : 1.3.6.1.4.1.12148.10.13.12.2.5.0] | |
eltek_eNexus_controlsystem_MainControlUnitsErrorValue | Eltek eNexus Main Control Units Error Value | count | Moniotrs the detected number of failed main controllers.[SP2-MIB :: mainControlUnitsErrorValue : 1.3.6.1.4.1.12148.10.13.12.1.5.0] | |
eltek_eNexus_io_IoUnitErrorValue | Eltek eNexus Io Unit Error Value | count | Monitors the detected number of failed IO units.[SP2-MIB :: ioUnitErrorValue : 1.3.6.1.4.1.12148.10.13.12.5.5.0] |
Eltek eNexus - Gse Generator
Description
Monitors the Eltek eNexus gse generator parameters like Generator Oil Pressure,Generator Coolant Temperature,Generator Fuel Level,Generator Engine Battery Voltage,Generator Engine Speed,Generator Frequency,Generator Engine Run Time,Generator Mode,Generator High Temperature,Generator Low Oil Pressure,Generator Fuel Probe Fail,Generator Fuel Tank Level Low,Generator Fuel Tank Loss,Generator RMS Communication Failure.[SP2-MIB :: gseGeneratorOilPressure : 1.3.6.1.4.1.12148.10.4.26.1.0,gseGeneratorCoolantTemperature : 1.3.6.1.4.1.12148.10.4.26.2.0,gseGeneratorFuelLevel : 1.3.6.1.4.1.12148.10.4.26.3.0,gseGeneratorEngineBatteryVoltage : 1.3.6.1.4.1.12148.10.4.26.4.0,gseGeneratorEngineSpeed : 1.3.6.1.4.1.12148.10.4.26.5.0,gseGeneratorFrequency : 1.3.6.1.4.1.12148.10.4.26.6.0,gseGeneratorEngineRunTime : 1.3.6.1.4.1.12148.10.4.26.7.0,gseGeneratorMode : 1.3.6.1.4.1.12148.10.4.26.8.0,gseGeneratorHighTemperature : 1.3.6.1.4.1.12148.10.4.26.10.0,gseGeneratorLowOilPressure : 1.3.6.1.4.1.12148.10.4.26.11.0,gseGeneratorFuelProbeFail : 1.3.6.1.4.1.12148.10.4.26.12.0,gseGeneratorFuelTankLevelLow : 1.3.6.1.4.1.12148.10.4.26.13.0,gseGeneratorFuelTankLoss : 1.3.6.1.4.1.12148.10.4.26.14.0,gseGeneratorRMSCommunicationFailure : 1.3.6.1.4.1.12148.10.4.26.15.0].
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Gse Generator | eltek_eNexus_gsegenerator_GseGeneratorFuelTankLevelLow | eltek_eNexus_gsegenerator_GseGeneratorFuelTankLevelLow | Monitors the Eltek eNexus gse generator fuel tank level low.[SP2-MIB :: gseGeneratorFuelTankLevelLow : 1.3.6.1.4.1.12148.10.4.26.13.0] | |
eltek_eNexus_gsegenerator_GseGeneratorCoolantTemperature | Eltek eNexus Gse Generator Coolant Temperature | F | Monitors the Eltek eNexus gse generator Coolant temperature.[SP2-MIB :: gseGeneratorCoolantTemperature : 1.3.6.1.4.1.12148.10.4.26.2.0] | |
eltek_eNexus_gsegenerator_GseGeneratorEngineRunTime | Eltek eNexus Gse Generator Engine Run Time | s | Monitors the Eltek eNexus gse generator engine run time in seconds.[SP2-MIB :: gseGeneratorEngineRunTime : 1.3.6.1.4.1.12148.10.4.26.7.0] | |
eltek_eNexus_gsegenerator_GseGeneratorEngineSpeed | Eltek eNexus Gse Generator Engine Speed | rpm | Monitors Eltek eNexus gse generator engine speed in RPM.[SP2-MIB :: gseGeneratorEngineSpeed : 1.3.6.1.4.1.12148.10.4.26.5.0] | |
eltek_eNexus_gsegenerator_GseGeneratorEngineBatteryVoltage | Eltek eNexus Gse Generator Engine Battery Voltage | v | Monitors the Eltek eNexus gse generator engine battery voltage.[SP2-MIB :: gseGeneratorEngineBatteryVoltage : 1.3.6.1.4.1.12148.10.4.26.4.0] | |
eltek_eNexus_gsegenerator_GseGeneratorFuelTankLoss | Eltek eNexus Gse Generator Fuel Tank Loss | Monitors the Eltek eNexus gse generator fuel tank loss.[SP2-MIB :: gseGeneratorFuelTankLoss : 1.3.6.1.4.1.12148.10.4.26.14.0].Possible values are disabledInput(0),notActiveAlarm(1),warningAlarm(2),shutdownAlarm(3),electricalTripAlarm(4),controlledShutdownAlarm(5),reserved1(6),reserved2(7),inactiveIndication1(8),inactiveIndication2(9),activeIndication(10),reserved3(11),unimplementedAlarm(12) | ||
eltek_eNexus_gsegenerator_GseGeneratorFuelProbeFail | Eltek eNexus Gse Generator Fuel Probe Fail | Monitors the Eltek eNexus gse generator fuel probe fail.[SP2-MIB :: gseGeneratorFuelProbeFail : 1.3.6.1.4.1.12148.10.4.26.12.0].Possible values are disabledInput(0),notActiveAlarm(1),warningAlarm(2),shutdownAlarm(3),electricalTripAlarm(4),controlledShutdownAlarm(5),reserved1(6),reserved2(7),inactiveIndication1(8),inactiveIndication2(9),activeIndication(10),reserved3(11),unimplementedAlarm(12) | ||
eltek_eNexus_gsegenerator_GseGeneratorRMSCommunicationFailure | Eltek eNexus Gse Generator RMS Communication Failure | Monitors the Eltek eNexus gse generator RMS communication failure.[SP2-MIB :: gseGeneratorRMSCommunicationFailure : 1.3.6.1.4.1.12148.10.4.26.15.0].Possible values are disabledInput(0),notActiveAlarm(1),warningAlarm(2),shutdownAlarm(3),electricalTripAlarm(4),controlledShutdownAlarm(5),reserved1(6),reserved2(7),inactiveIndication1(8),inactiveIndication2(9),activeIndication(10),reserved3(11),unimplementedAlarm(12) | ||
eltek_eNexus_gsegenerator_GseGeneratorMode | Eltek eNexus Gse Generator Mode | Monitors the Eltek eNexus gse generator Auto/manual mode.[SP2-MIB :: gseGeneratorMode : 1.3.6.1.4.1.12148.10.4.26.8.0].Possible values are stop(0),auto(1),manual(2),testOnLoad(3),autoWithManualRestore(4),userConfigutation(5),off(6). | ||
eltek_eNexus_gsegenerator_GseGeneratorOilPressure | Eltek eNexus Gse Generator Oil Pressure | Monitors the gse generator oil pressure in kpa.[SP2-MIB :: gseGeneratorOilPressure : 1.3.6.1.4.1.12148.10.4.26.1.0] | ||
eltek_eNexus_gsegenerator_GseGeneratorFrequency | Eltek eNexus Gse Generator Frequency | Hz | Monitors Eltek eNexus gse generator frequency in Hz.[SP2-MIB :: gseGeneratorFrequency : 1.3.6.1.4.1.12148.10.4.26.6.0] | |
eltek_eNexus_gsegenerator_GseGeneratorHighTemperature | Eltek eNexus Gse Generator High Temperature | Monitors the Eltek eNexus gse generator high temperature.[SP2-MIB :: gseGeneratorHighTemperature : 1.3.6.1.4.1.12148.10.4.26.10.0].Possible values are disabledInput(0),notActiveAlarm(1),warningAlarm(2),shutdownAlarm(3),electricalTripAlarm(4),controlledShutdownAlarm(5),reserved1(6),reserved2(7),inactiveIndication1(8),inactiveIndication2(9),activeIndication(10),reserved3(11),unimplementedAlarm(12) | ||
eltek_eNexus_gsegenerator_GseGeneratorLowOilPressure | Eltek eNexus Gse Generator Low Oil Pressure | Monitors the Eltek eNexus Gse generator low oil pressure.[SP2-MIB :: gseGeneratorLowOilPressure : 1.3.6.1.4.1.12148.10.4.26.11.0].Possible values are disabledInput(0),notActiveAlarm(1),warningAlarm(2),shutdownAlarm(3),electricalTripAlarm(4),controlledShutdownAlarm(5),reserved1(6),reserved2(7),inactiveIndication1(8),inactiveIndication2(9),activeIndication(10),reserved3(11),unimplementedAlarm(12) | ||
eltek_eNexus_gsegenerator_GseGeneratorFuelLevel | Eltek eNexus Gse Generator Fuel Level | % | Monitors the Gse generator fuel level.[SP2-MIB :: gseGeneratorFuelLevel : 1.3.6.1.4.1.12148.10.4.26.3.0] |
Eltek eNexus - Hardware Status
Description
Monitors the Eltek eNexus hardware status parameters like Power System Status,Mains Status,Generator Status,Generator Failure Status,Rectifiers Status,Solar Chargers Status,Wind Chargers Status,Load Status,Load Fuses Status,Battery Status,Battery Fuses Status,Battery Quality Status,Battery LVBD Status,Battery Ah Charged Status,Battery Ah Discharged Status,Control System Status,Smart Node Error Status,Battery Monitor Error Status,Load Monitor Error Status,Io Unit Error Status,Mains Monitor Error Status,Flexi Monitor Error Status,Ambient Temperature Status,DeltaTemperatureStatus,User Suspended Status,Battery Group2 Status,Battery Group2 Ah Charged Status,Battery Group2 Ah Discharged Status,Inverters Status,Grid Inverters Status,Rectiverters Status.[SP2-MIB :: powerSystemStatus : 1.3.6.1.4.1.12148.10.2.1.0,mainsStatus : 1.3.6.1.4.1.12148.10.3.1.0,generatorStatus : 1.3.6.1.4.1.12148.10.4.1.0,generatorFailStatus : 1.3.6.1.4.1.12148.10.4.2.0,rectifiersStatus : 1.3.6.1.4.1.12148.10.5.1.0,solarChargersStatus : 1.3.6.1.4.1.12148.10.7.1.0,windChargersStatus : 1.3.6.1.4.1.12148.10.8.1.0,loadStatus : 1.3.6.1.4.1.12148.10.9.1.0,loadFusesStatus : 1.3.6.1.4.1.12148.10.9.3.0,batteryStatus : 1.3.6.1.4.1.12148.10.10.1.0,batteryFusesStatus : 1.3.6.1.4.1.12148.10.10.4.0,batteryQualityStatus : 1.3.6.1.4.1.12148.10.10.12.1.0,batteryLVBDStatus : 1.3.6.1.4.1.12148.10.10.13.1.0,batteryAhChargedStatus : 1.3.6.1.4.1.12148.10.10.23.1.0,batteryAhDischargedStatus : 1.3.6.1.4.1.12148.10.10.24.1.0,controlSystemStatus : 1.3.6.1.4.1.12148.10.13.1.0,smartNodeErrorStatus : 1.3.6.1.4.1.12148.10.13.12.2.1.0,batteryMonitorErrorStatus : 1.3.6.1.4.1.12148.10.13.12.3.1.0,loadMonitorErrorStatus : 1.3.6.1.4.1.12148.10.13.12.4.1.0,ioUnitErrorStatus : 1.3.6.1.4.1.12148.10.13.12.5.1.0,mainsMonitorErrorStatus : 1.3.6.1.4.1.12148.10.13.12.6.1.0,flexiMonitorErrorStatus : 1.3.6.1.4.1.12148.10.13.12.7.1.0,ambientTemperatureStatus : 1.3.6.1.4.1.12148.10.13.13.1.0,deltaTemperatureStatus : 1.3.6.1.4.1.12148.10.13.14.1.0,userSuspendedStatus : 1.3.6.1.4.1.12148.10.13.15.1.0,batteryGroup2Status : 1.3.6.1.4.1.12148.10.15.1.0,batteryGroup2AhChargedStatus : 1.3.6.1.4.1.12148.10.15.22.1.0,batteryGroup2AhDischargedStatus : 1.3.6.1.4.1.12148.10.15.23.1.0,invertersStatus : 1.3.6.1.4.1.12148.10.16.1.0,gridInvertersStatus : 1.3.6.1.4.1.12148.10.17.1.0,rectivertersStatus : 1.3.6.1.4.1.12148.10.18.1.0]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Hardware Status | eltek_eNexus_load_LoadFusesStatus | Eltek eNexus Load Fuses Status | Monitors the overall status of the load fuses.[SP2-MIB :: loadFusesStatus : 1.3.6.1.4.1.12148.10.9.3.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | |
eltek_eNexus_mainsMainsFailure_MainsMainsFailureStatus | Eltek eNexus Mains Mains Failure Status | It displays if the number of failed phases is higher than the defined alarm level.[SP2-MIB :: mainsMainsFailureStatus : 1.3.6.1.4.1.12148.10.3.2.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_ioUnitError_IoUnitErrorStatus | Eltek eNexus Io Unit Error Status | Monitors the status value shows if the number of failed IO units is higher than the defined alarm level.[SP2-MIB :: ioUnitErrorStatus : 1.3.6.1.4.1.12148.10.13.12.5.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_rectiverters_RectivertersStatus | Eltek eNexus Rectiverters Status | Monitors the overall status of rectifier subsystem.[SP2-MIB :: rectivertersStatus : 1.3.6.1.4.1.12148.10.18.1.0]. Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_batteryGroup2AhDischarged_BatteryGroup2AhDischargedStatus | Eltek eNexus Battery Group2 Ah Discharged Status | Monitors the status of the battery ah discharged monitor.[SP2-MIB :: batteryGroup2AhDischargedStatus : 1.3.6.1.4.1.12148.10.15.23.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_generator_GeneratorStatus | Eltek eNexus Generator Status | Monitors the overall status of generator subsystem.[SP2-MIB :: generatorStatus : 1.3.6.1.4.1.12148.10.4.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_battery_BatteryLVBDStatus | Eltek eNexus Battery LVBD Status | Monitors the battery contactor is connected,disconnected,disabled or in any other alarm condition.[SP2-MIB :: batteryLVBDStatus : 1.3.6.1.4.1.12148.10.10.13.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_battery_BatteryAhDischargedStatus | Eltek eNexus Battery Ah Discharged Status | Monitors the status of the battery ah discharged monitor.[SP2-MIB :: batteryAhDischargedStatus : 1.3.6.1.4.1.12148.10.10.24.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_battery_BatteryAhChargedStatus | Eltek eNexus Battery Ah Charged Status | Monitors the status of the battery ah charged monitor.[SP2-MIB :: batteryAhChargedStatus : 1.3.6.1.4.1.12148.10.10.23.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_solarchargers_SolarChargersStatus | Eltek eNexus Solar Chargers Status | Monitors the overall status of solar charger subsystem.[SP2-MIB :: solarChargersStatus : 1.3.6.1.4.1.12148.10.7.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_batteryMonitorError_BatteryMonitorErrorStatus | Eltek eNexus Battery Monitor Error Status | Monitors the status value shows if the number of failed battery monitors is higher than the defined alarm level.[SP2-MIB :: batteryMonitorErrorStatus : 1.3.6.1.4.1.12148.10.13.12.3.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_flexiMonitorError_FlexiMonitorErrorStatus | Eltek eNexus Flexi Monitor Error Status | Monitors the status value shows if the number of failed flexi monitors is higher than the defined alarm level.[SP2-MIB :: flexiMonitorErrorStatus : 1.3.6.1.4.1.12148.10.13.12.7.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_mains_MainsStatus | Eltek eNexus Mains Status | Monitors the overall status of mains/AC feed subsystem.[SP2-MIB :: mainsStatus : 1.3.6.1.4.1.12148.10.3.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_mainsMonitorError_MainsMonitorErrorStatus | Eltek eNexus Mains Monitor Error Status | Monitors the status value shows if the number of failed mains monitors is higher than the defined alarm level.[SP2-MIB :: mainsMonitorErrorStatus : 1.3.6.1.4.1.12148.10.13.12.6.1.0]possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_battery_BatteryFusesStatus | Eltek eNexus Battery Fuses Status | Monitors the state of the battery fuses/breakers.[SP2-MIB :: batteryFusesStatus : 1.3.6.1.4.1.12148.10.10.4.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_userSuspended_UserSuspendedStatus | Eltek eNexus User Suspended Status | Monitors the status value shows if the number of failed attempts is higher than the defined alarm level.[SP2-MIB :: userSuspendedStatus : 1.3.6.1.4.1.12148.10.13.15.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_batteryGroup2AhCharged_BatteryGroup2AhChargedStatus | Eltek eNexus Battery Group2 Ah Charged Status | Monitors the status of the battery ah charged monitor.[SP2-MIB :: batteryGroup2AhChargedStatus : 1.3.6.1.4.1.12148.10.15.22.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_gridInverters_GridInvertersStatus | Eltek eNexus Grid Inverters Status | Monitors the overall status of inverter subsystem.[SP2-MIB :: gridInvertersStatus : 1.3.6.1.4.1.12148.10.17.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_deltaTemperature_DeltaTemperatureStatus | Eltek eNexus Delta Temperature Status | Monitors the state of the delta temperature can be either one of the defined enumerated values.[SP2-MIB :: deltaTemperatureStatus : 1.3.6.1.4.1.12148.10.13.14.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_batteryGroup2_BatteryGroup2Status | Eltek eNexus Battery Group2 Status | Monitors the toplevel status for the battery group 2.[SP2-MIB :: batteryGroup2Status : 1.3.6.1.4.1.12148.10.15.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_inverters_InvertersStatus | Eltek eNexus Inverters Status | Monitors the overall status of inverter subsystem.[SP2-MIB :: invertersStatus : 1.3.6.1.4.1.12148.10.16.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_battery_BatteryStatus | Eltek eNexus Battery Status | Monitors the top-level status for the battery subsystem.[SP2-MIB :: batteryStatus : 1.3.6.1.4.1.12148.10.10.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_ambientTemperature_AmbientTemperatureStatus | Eltek eNexus Ambient Temperature Status | Monitors the state of the ambient temperature can be either one of the defined enumerated values.[SP2-MIB :: ambientTemperatureStatus : 1.3.6.1.4.1.12148.10.13.13.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_powersystem_PowerSystemStatus | Eltek eNexus Power System Status | Monitors the overall condition of the power system.[SP2-MIB :: powerSystemStatus : 1.3.6.1.4.1.12148.10.2.1].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_controlSystem_ControlSystemStatus | Eltek eNexus Control System Status | Monitors the overall status of control system subsystem.[SP2-MIB :: controlSystemStatus : 1.3.6.1.4.1.12148.10.13.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_load_LoadStatus | Eltek eNexus Load Status | Monitors the overall status of load subsystem.[SP2-MIB :: loadStatus : 1.3.6.1.4.1.12148.10.9.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_smartNodeError_SmartNodeErrorStatus | Eltek eNexus Smart Node Error Status | Monitor the status value shows if the number of failed smartnodes is higher than the defined alarm level.[SP2-MIB :: smartNodeErrorStatus : 1.3.6.1.4.1.12148.10.13.12.2.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_loadMonitorError_LoadMonitorErrorStatus | Eltek eNexus Load Monitor Error Status | Monitor status value shows if the number of failed load monitors is higher than the defined alarm level.[SP2-MIB :: bloadMonitorErrorStatus : 1.3.6.1.4.1.12148.10.13.12.4.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_generator_GeneratorFailStatus | Eltek eNexus Generator Failure Status | Monitors the status of generator failure monitor.[SP2-MIB :: generatorFailStatus : 1.3.6.1.4.1.12148.10.4.2.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_rectifiers_RectifiersStatus | Eltek eNexus Rectifiers Status | Monitors the overall status of rectifier subsystem.[SP2-MIB :: grectifiersStatus : 1.3.6.1.4.1.12148.10.5.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) . | ||
eltek_eNexus_windChargers_WindChargersStatus | Eltek eNexus Wind Chargers Status | Monitors the overall status of wind charger subsystem.[SP2-MIB :: windChargersStatus : 1.3.6.1.4.1.12148.10.8.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_battery_BatteryQualityStatus | Eltek eNexus Battery Quality Status | Monitors the status of the battery quality (SoH) monitor.[SP2-MIB :: batteryQualityStatus : 1.3.6.1.4.1.12148.10.10.12.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). |
Eltek eNexus - Input
Description
Monitors the Eltek eNexus input control unit input parameters like Input Control Unit Input Status,Input Control Unit Input Value,inputs available in controller,inputs available in IO unit.[SP2-MIB :: inputControlUnitInputStatus : 1.3.6.1.4.1.12148.10.11.2.1.2,inputControlUnitInputValue : 1.3.6.1.4.1.12148.10.11.2.1.6,inputControlUnitNumberOfInputs : 1.3.6.1.4.1.12148.10.11.1.1.2,inputIoUnitNumberOfInputs : 1.3.6.1.4.1.12148.10.11.3.1.2].
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Input Control Unit Input | eltek_eNexus_Inputs_InputControlUnitInputStatus | Eltek eNexus Input Control Unit Input Status | Monitors the programmable input status.[SP2-MIB :: inputControlUnitInputStatus : 1.3.6.1.4.1.12148.10.11.2.1.2]. Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | |
eltek_eNexus_Inputs_InputControlUnitInputValue | Eltek eNexus Input Control Unit Input Value | Monitors the inputs measured Value.[SP2-MIB :: inputControlUnitInputValue : 1.3.6.1.4.1.12148.10.11.2.1.6] | ||
Eltek eNexus - Input Control Units | eltek_eNexus_Inputs_InputControlUnitNumberOfInputs | Eltek eNexus Input Control Unit Number Of Inputs | count | Monitors the number of programmable inputs available in controller.[SP2-MIB :: inputControlUnitNumberOfInputs : 1.3.6.1.4.1.12148.10.11.1.1.2]. |
Eltek eNexus - Input IO | eltek_eNexus_Inputs_InputIoUnitNumberOfInputs | Eltek eNexus Input Io Unit Number Of Inputs | count | Monitors the number of programmable inputs available in IO unit.[SP2-MIB :: inputIoUnitNumberOfInputs : 1.3.6.1.4.1.12148.10.11.3.1.2]. |
Eltek eNexus - Inverters
Description
Monitors the grid inverters parameters like Grid Inverters Error Status,Grid Inverters Temperature Status,Grid Inverters Temperature Value,Grid Inverters Ac Current1 Status,Grid Inverters Ac Current1 Value,Grid Inverters Ac Current2 Status,Grid Inverters Ac Current2 Value,Grid Inverters Ac Current3 Status,Grid Inverters Ac Current3 Value,Grid Inverters Power Status,Grid Inverters Power Value,Grid Inverters Frequency Status,Grid Inverters Frequency Value,Grid Inverters Ac Disconnect Status,Eltek eNexus Grid Inverters Ac Disconnect Value,Grid Inverters Dc Current,Grid Inverters Ac Voltage1,Grid Inverters Ac Voltage2,Grid Inverters Ac Voltage3,Inverters Error Status,Inverters Temperature Status,Inverters Temperature Value,Inverters Ac Current1 Status,Inverters Ac Current1 Value,Inverters Ac Current2 Status,Inverters Ac Current2 Value,Inverters Ac Current3 Status,Inverters Ac Current3 Value,Inverters Ac Voltage1 Status,Inverters Ac Voltage1 Value,Inverters Ac Voltage2 Status,Inverters Ac Voltage2 Value,Inverters Ac Voltage3 Status,Inverters Ac Voltage3 Value,Inverters Ac Frequency Deviation Status,Inverters Ac Frequency Deviation Value,Eltek eNexus Inverters Ac Frequency.[SP2-MIB :: gridInvertersErrorStatus : 1.3.6.1.4.1.12148.10.17.2.1.0,gridInvertersTemperatureStatus : 1.3.6.1.4.1.12148.10.17.3.1.0,gridInvertersTemperatureValue : 1.3.6.1.4.1.12148.10.17.3.5.0,gridInvertersAcCurrent1Status : 1.3.6.1.4.1.12148.10.17.4.1.0,gridInvertersAcCurrent1Value : 1.3.6.1.4.1.12148.10.17.4.5.0,gridInvertersAcCurrent2Status : 1.3.6.1.4.1.12148.10.17.5.1.0,gridInvertersAcCurrent2Value : 1.3.6.1.4.1.12148.10.17.5.5.0,gridInvertersAcCurrent3Status : 1.3.6.1.4.1.12148.10.17.6.1.0,gridInvertersAcCurrent3Value : 1.3.6.1.4.1.12148.10.17.6.5.0,gridInvertersPowerStatus : 1.3.6.1.4.1.12148.10.17.7.1.0,gridInvertersPowerValue : 1.3.6.1.4.1.12148.10.17.7.5.0,gridInvertersFrequencyStatus : 1.3.6.1.4.1.12148.10.17.8.1.0,gridInvertersFrequencyValue : 1.3.6.1.4.1.12148.10.17.8.5.0,gridInvertersAcDisconnectStatus : 1.3.6.1.4.1.12148.10.17.9.1.0,gridInvertersAcDisconnectValue : 1.3.6.1.4.1.12148.10.17.9.5.0,gridInvertersDcCurrent : 1.3.6.1.4.1.12148.10.17.10.0,gridInvertersAcVoltage1 : 1.3.6.1.4.1.12148.10.17.11.0,gridInvertersAcVoltage2 : 1.3.6.1.4.1.12148.10.17.12.0,gridInvertersAcVoltage3 : 1.3.6.1.4.1.12148.10.17.13.0,invertersErrorStatus : 1.3.6.1.4.1.12148.10.16.2.1.0,invertersTemperatureStatus : 1.3.6.1.4.1.12148.10.16.3.1.0,invertersTemperatureValue : 1.3.6.1.4.1.12148.10.16.3.5.0,invertersAcCurrent1Status : 1.3.6.1.4.1.12148.10.16.4.1.0,invertersAcCurrent1Value : 1.3.6.1.4.1.12148.10.16.4.5.0,invertersAcCurrent2Status : 1.3.6.1.4.1.12148.10.16.5.1.0,invertersAcCurrent2Value : 1.3.6.1.4.1.12148.10.16.5.5.0,invertersAcCurrent3Status : 1.3.6.1.4.1.12148.10.16.6.1.0,invertersAcCurrent3Value : 1.3.6.1.4.1.12148.10.16.6.5.0,invertersAcVoltage1Status : 1.3.6.1.4.1.12148.10.16.7.1.0,invertersAcVoltage1Value : 1.3.6.1.4.1.12148.10.16.7.5.0,invertersAcVoltage2Status : 1.3.6.1.4.1.12148.10.16.8.1.0,invertersAcVoltage2Value : 1.3.6.1.4.1.12148.10.16.8.5.0,invertersAcVoltage3Status : 1.3.6.1.4.1.12148.10.16.9.1.0,invertersAcVoltage3Value : 1.3.6.1.4.1.12148.10.16.9.5.0,invertersAcFrequencyDeviationStatus : 1.3.6.1.4.1.12148.10.16.10.1.0,invertersAcFrequencyDeviationValue : 1.3.6.1.4.1.12148.10.16.10.5.0,invertersAcFrequency : 1.3.6.1.4.1.12148.10.16.11.0].
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Grid Inverters | eltek_eNexus_GridInvertersAcDisconnectValue | Eltek eNexus Grid Inverters Ac Disconnect Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: gridInvertersAcDisconnectValue : 1.3.6.1.4.1.12148.10.17.9.5.0] |
eltek_eNexus_GridInvertersAcCurrent3Value | Eltek eNexus Grid Inverters Ac Current3 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: gridInvertersAcCurrent3Value : 1.3.6.1.4.1.12148.10.17.6.5.0] | |
eltek_eNexus_GridInvertersAcCurrent3Status | Eltek eNexus Grid Inverters Ac Current3 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: gridInvertersAcCurrent3Status : 1.3.6.1.4.1.12148.10.17.6.1.0] | ||
eltek_eNexus_GridInvertersAcCurrent1Status | Eltek eNexus Grid Inverters Ac Current1 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: gridInvertersAcCurrent1Status : 1.3.6.1.4.1.12148.10.17.4.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) . | ||
eltek_eNexus_GridInvertersPowerStatus | Eltek eNexus Grid Inverters Power Status | monitors the status of the measured total inverter power.[SP2-MIB :: gridInvertersPowerStatus : 1.3.6.1.4.1.12148.10.17.7.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_GridInvertersErrorStatus | Eltek eNexus Grid Inverters Error Status | Monitors the Eltek eNexus grid inverters error status.[SP2-MIB :: gridInvertersErrorStatus : 1.3.6.1.4.1.12148.10.17.2.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_GridInvertersFrequencyStatus | Eltek eNexus Grid Inverters Frequency Status | Monitors the status of the measured total inverter power.[SP2-MIB :: gridInvertersFrequencyStatus : 1.3.6.1.4.1.12148.10.17.8.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_GridInvertersFrequencyValue | Eltek eNexus Grid Inverters Frequency Value | amps | Monitors the value of the measured total inverter current.[SP2-MIB :: gridInvertersFrequencyValue : 1.3.6.1.4.1.12148.10.17.8.5.0]. | |
eltek_eNexus_GridInvertersAcVoltage1 | Eltek eNexus Grid Inverters Ac Voltage1 | amps | Monitors the total installed/available inverter power.[SP2-MIB :: gridInvertersAcVoltage1 : 1.3.6.1.4.1.12148.10.17.11.0] | |
eltek_eNexus_GridInvertersAcCurrent2Value | Eltek eNexus Grid Inverters Ac Current2 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: [SP2-MIB :: gridInvertersAcCurrent2Value : 1.3.6.1.4.1.12148.10.17.5.5.0] | |
eltek_eNexus_GridInvertersAcVoltage2 | Eltek eNexus Grid Inverters Ac Voltage2 | amps | Monitors the total installed/available inverter power.[SP2-MIB :: gridInvertersAcVoltage2 : 1.3.6.1.4.1.12148.10.17.12.0] | |
eltek_eNexus_GridInvertersAcCurrent2Status | Eltek eNexus Grid Inverters Ac Current2 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: gridInvertersAcCurrent2Status : 1.3.6.1.4.1.12148.10.17.5.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_GridInvertersDcCurrent | Eltek eNexus Grid Inverters Dc Current | amps | Monitors the total installed/available inverter power.[SP2-MIB :: gridInvertersDcCurrent : 1.3.6.1.4.1.12148.10.17.10.0] | |
eltek_eNexus_GridInvertersAcVoltage3 | Eltek eNexus Grid Inverters Ac Voltage3 | amps | Monitors the total installed/available inverter power.[SP2-MIB :: gridInvertersAcVoltage3 : 1.3.6.1.4.1.12148.10.17.13.0] | |
eltek_eNexus_GridInvertersPowerValue | Eltek eNexus Grid Inverters Power Value | amps | Monitors the value of the measured total inverter current.[SP2-MIB :: gridInvertersPowerValue : 1.3.6.1.4.1.12148.10.17.7.5.0] | |
eltek_eNexus_GridInvertersTemperatureStatus | Eltek eNexus Grid Inverters Temperature Status | Monitors the state of the rectifier temperature.[SP2-MIB :: gridInvertersTemperatureStatus : 1.3.6.1.4.1.12148.10.17.3.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_GridInvertersAcDisconnectStatus | Eltek eNexus Grid Inverters Ac Disconnect Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: gridInvertersAcDisconnectStatus : 1.3.6.1.4.1.12148.10.17.9.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_GridInvertersAcCurrent1Value | Eltek eNexus Grid Inverters Ac Current1 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: gridInvertersAcCurrent1Value : 1.3.6.1.4.1.12148.10.17.4.5.0] | |
eltek_eNexus_GridInvertersTemperatureValue | Eltek eNexus Grid Inverters Temperature Value | F | monitors the highest value of the rectifier temperature measurements.[SP2-MIB :: gridInvertersTemperatureValue : 1.3.6.1.4.1.12148.10.17.3.5.0] | |
Eltek eNexus - Inverters | eltek_eNexus_InvertersAcCurrent3Value | Eltek eNexus Inverters Ac Current3 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: invertersAcCurrent3Value : 1.3.6.1.4.1.12148.10.16.6.5.0] |
eltek_eNexus_InvertersTemperatureValue | Eltek eNexus Inverters Temperature Value | F | Monitors the highest value of the rectifier temperature measurements.[SP2-MIB :: invertersTemperatureValue : 1.3.6.1.4.1.12148.10.16.3.5.0]. | |
eltek_eNexus_InvertersAcCurrent2Status | Eltek eNexus Inverters Ac Current2 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: invertersAcCurrent2Status : 1.3.6.1.4.1.12148.10.16.5.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_InvertersAcFrequencyDeviationStatus | Eltek eNexus Inverters Ac Frequency Deviation Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: invertersAcFrequencyDeviationStatus : 1.3.6.1.4.1.12148.10.16.10.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_InvertersTemperatureStatus | Eltek eNexus Inverters Temperature Status | Monitors the state of the rectifier temperature.[SP2-MIB :: invertersTemperatureStatus : 1.3.6.1.4.1.12148.10.16.3.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_InvertersAcVoltage1Status | Eltek eNexus Inverters Ac Voltage1 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: invertersAcVoltage1Status : 1.3.6.1.4.1.12148.10.16.7.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_InvertersAcVoltage3Value | Eltek eNexus Inverters Ac Voltage3 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: invertersAcVoltage3Value : 1.3.6.1.4.1.12148.10.16.9.5.0] | |
eltek_eNexus_InvertersAcCurrent1Value | Eltek eNexus Inverters Ac Current1 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: invertersAcCurrent1Value : 1.3.6.1.4.1.12148.10.16.4.5.0] | |
eltek_eNexus_InvertersErrorStatus | Eltek eNexus Inverters Error Status | Monitors the Inverters error status.[SP2-MIB :: invertersErrorStatus : 1.3.6.1.4.1.12148.10.16.2.1.0]. | ||
eltek_eNexus_InvertersAcVoltage3Status | Eltek eNexus Inverters Ac Voltage3 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: invertersAcVoltage3Status : 1.3.6.1.4.1.12148.10.16.9.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_InvertersAcFrequency | Eltek eNexus Inverters Ac Frequency | Hz | Monitors the Inverters Ac frequency.[SP2-MIB :: invertersAcFrequency : 1.3.6.1.4.1.12148.10.16.11.0] | |
eltek_eNexus_InvertersAcCurrent2Value | Eltek eNexus Inverters Ac Current2 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: invertersAcCurrent2Value : 1.3.6.1.4.1.12148.10.16.5.5.0] | |
eltek_eNexus_InvertersAcCurrent1Status | Eltek eNexus Inverters Ac Current1 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: invertersAcCurrent1Status : 1.3.6.1.4.1.12148.10.16.4.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_InvertersAcVoltage1Value | Eltek eNexus Inverters Ac Voltage1 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: invertersAcVoltage1Value : 1.3.6.1.4.1.12148.10.16.7.5.0] | |
eltek_eNexus_InvertersAcVoltage2Value | Eltek eNexus Inverters Ac Voltage2 Value | amps | Monitors the value of the measured total rectifier current.SP2-MIB :: invertersAcVoltage2Value : 1.3.6.1.4.1.12148.10.16.8.5.0] | |
eltek_eNexus_InvertersAcVoltage2Status | Eltek eNexus Inverters Ac Voltage2 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: invertersAcVoltage2Status : 1.3.6.1.4.1.12148.10.16.8.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_InvertersAcFrequencyDeviationValue | Eltek eNexus Inverters Ac Frequency Deviation Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: invertersAcFrequencyDeviationValue : 1.3.6.1.4.1.12148.10.16.10.5.0] | |
eltek_eNexus_InvertersAcCurrent3Status | Eltek eNexus Inverters Ac Current3 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: invertersAcCurrent3Status : 1.3.6.1.4.1.12148.10.16.6.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). |
Eltek eNexus - Load
Description
Monitors the Eltek eNexus load parameters like Load Current Status,Load Current Value,Load Fuse Status,Load Fuse Value,status of load group,Load LVLD Status,Load LVLD Value,Load Voltage Status,Load Voltage Value.[SP2-MIB :: loadCurrentStatus : 1.3.6.1.4.1.12148.10.9.2.1.0,loadCurrentValue : 1.3.6.1.4.1.12148.10.9.2.5.0,loadFuseStatus : 1.3.6.1.4.1.12148.10.9.7.1.1,loadFuseValue : 1.3.6.1.4.1.12148.10.9.7.1.5,loadGroupStatus : 1.3.6.1.4.1.12148.10.9.5.1.2,loadLVLDStatus : 1.3.6.1.4.1.12148.10.9.6.1.2,loadLVLDValue : 1.3.6.1.4.1.12148.10.9.6.1.6,loadVoltageStatus : 1.3.6.1.4.1.12148.10.9.9.1.2,loadVoltageValue : 1.3.6.1.4.1.12148.10.9.9.1.6].
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Load | eltek_eNexus_load_LoadCurrentValue | Eltek eNexus Load Current Value | amps | Monitors the value of the measured load current.[SP2-MIB :: loadCurrentValue : 1.3.6.1.4.1.12148.10.9.2.5.0] |
eltek_eNexus_load_LoadCurrentStatus | Eltek eNexus Load Current Status | Monitors the status of the measured load current.[SP2-MIB :: loadCurrentStatus : 1.3.6.1.4.1.12148.10.9.2.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
Eltek eNexus - Load Fuse | eltek_eNexus_load_LoadFuseValue | Eltek eNexus Load Fuse Value | amps | Monitors the measured value of the load fuse.[SP2-MIB :: loadFuseValue : 1.3.6.1.4.1.12148.10.9.7.1.5] |
eltek_eNexus_load_LoadFuseStatus | Eltek eNexus Load Fuse Status | Monitors the status of load fuse.[SP2-MIB :: loadFuseStatus : 1.3.6.1.4.1.12148.10.9.7.1.1].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
Eltek eNexus - Load Group Status | eltek_eNexus_load_LoadGroupStatus | Eltek eNexus Load Group Status | Monitors the status of load group.[SP2-MIB :: loadGroupStatus : 1.3.6.1.4.1.12148.10.9.5.1.2].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | |
Eltek eNexus - Load LVLD | eltek_eNexus_load_LoadLVLDStatus | Eltek eNexus Load LVLD Status | Monitors status of LVLD.[SP2-MIB :: loadLVLDStatus : 1.3.6.1.4.1.12148.10.9.6.1.2] | |
eltek_eNexus_load_LoadLVLDValue | Eltek eNexus Load LVLD Value | v | Monitors the measured value of the LVLD.[SP2-MIB :: loadLVLDValue : 1.3.6.1.4.1.12148.10.9.6.1.6] | |
Eltek eNexus - Load Voltage | eltek_eNexus_load_LoadVoltageStatus | Eltek eNexus Load Voltage Status | Monitors the status of voltage.[SP2-MIB :: loadVoltageStatus : 1.3.6.1.4.1.12148.10.9.9.1.2] | |
eltek_eNexus_load_LoadVoltageValue | Eltek eNexus Load Voltage Value | v | Monitors the measured value of the voltage.[SP2-MIB :: loadVoltageValue : 1.3.6.1.4.1.12148.10.9.9.1.6] |
Eltek eNexus - Mains
Description
Monitors the Eltek eNexus mains parameters like Mains Monitor Frequency Status,Mains Monitor Frequency Value,Mains Monitor Voltage Status,Mains Monitor Voltage Value,Mains Voltage Status,Mains Voltage Value.[SP2-MIB :: mainsMonitorFrequencyStatus : 1.3.6.1.4.1.12148.10.3.5.5.1.1,mainsMonitorFrequencyValue : 1.3.6.1.4.1.12148.10.3.5.5.1.5,mainsMonitorVoltageStatus : 1.3.6.1.4.1.12148.10.3.5.3.1.2,mainsMonitorVoltageValue : 1.3.6.1.4.1.12148.10.3.5.3.1.6,mainsVoltageStatus : 1.3.6.1.4.1.12148.10.3.4.1.2,mainsVoltageValue : 1.3.6.1.4.1.12148.10.3.4.1.6]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Control Unit Status | eltek_eNexus_ControlUnitStatus | Eltek eNexus Control Unit Status | Monitors the textual description of the control unit.[SP2-MIB :: controlUnitStatus : 1.3.6.1.4.1.12148.10.13.8.2.1.3]. Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | |
Eltek eNexus - Main Control Unit Earth Fault | eltek_eNexus_mainControlUnitEarthFaultStatus | Eltek eNexus Main Control Unit Earth Fault Status | Monitors the earth fault monitor.[SP2-MIB :: mainControlUnitEarthFaultStatus : 1.3.6.1.4.1.12148.10.13.11.3.1.1] | |
eltek_eNexus_mainControlUnitEarthFaultValue | Eltek eNexus Main Control Unit Earth Fault Value | Kbps | Monitor the measured value of the earth resistance in kOhm..[SP2-MIB :: mainControlUnitEarthFaultValue : 1.3.6.1.4.1.12148.10.13.11.3.1.5]. | |
Eltek eNexus - Main Control Unit Temperature | eltek_eNexus_mainControlUnitTemperatureValue | Eltek eNexus Main Control Unit Temperature Value | Celsius | Monitors the the measured battery temperature.[SP2-MIB :: mainControlUnitTemperatureValue : 1.3.6.1.4.1.12148.10.13.11.2.1.6] |
eltek_eNexus_mainControlUnitTemperatureStatus | Eltek eNexus Main Control Unit Temperature Status | Monitors the status of battery temperature monitor.[SP2-MIB :: mainControlUnitTemperatureStatus : 1.3.6.1.4.1.12148.10.13.11.2.1.2].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
Eltek eNexus - Mains Monitor Frequency | eltek_eNexus_mainsmonitorcurrent_MainsMonitorFrequencyValue | Eltek eNexus Mains Monitor Frequency Value | Hz | Monitors the value of the measured mains frequency in AC Mains Monitor.[SP2-MIB :: mainsMonitorFrequencyValue : 1.3.6.1.4.1.12148.10.3.5.5.1.5] |
eltek_eNexus_mainsmonitorcurrent_MainsMonitorFrequencyStatus | Eltek eNexus Mains Monitor Frequency Status | Monitors the status of the measured mains frequency in AC Mains Monitor.[SP2-MIB :: mainsMonitorFrequencyStatus : 1.3.6.1.4.1.12148.10.3.5.5.1.1].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) . | ||
Eltek eNexus - Mains Voltage | eltek_eNexus_mainsvoltage_MainsVoltageStatus | Eltek eNexus Mains Voltage Status | Monitors the status of the measured mains voltage.[SP2-MIB :: mainsVoltageStatus : 1.3.6.1.4.1.12148.10.3.4.1.2].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | |
eltek_eNexus_mainsvoltage_MainsVoltageValue | Eltek eNexus Mains Voltage Value | v | Monitors the value of the measured mains voltage.[SP2-MIB :: mainsVoltageValue : 1.3.6.1.4.1.12148.10.3.4.1.6] |
Eltek eNexus - Output
Description
Monitor the number of outputs available in controller,output control units status.[SP2-MIB :: outputControlUnitNumberOfOutputs : 1.3.6.1.4.1.12148.10.12.1.1.2,outputControlUnitOutputStatus : 1.3.6.1.4.1.12148.10.12.2.1.2]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Output Control Units | eltek_eNexus_Outputs_OutputControlUnitNumberOfOutputs | Eltek eNexus Output Control Unit Number Of Outputs | count | Monitor the number of outputs available in controller.[SP2-MIB :: outputControlUnitNumberOfOutputs : 1.3.6.1.4.1.12148.10.12.1.1.2] |
Eltek eNexus - Output Control Units Status | eltek_eNexus_Outputs_OutputControlUnitOutputStatus | Eltek eNexus Output Control Unit Output Status | Monitors the Eltek eNexus output control units status.[SP2-MIB :: outputControlUnitOutputStatus : 1.3.6.1.4.1.12148.10.12.2.1.2]. Possible values are notenergized(0),energized(1),disconnected(2),connected(3). |
Eltek eNexus - Rectifiers
Description
Monitors the Eltek eNexus rectifiers parameters like Rectifiers Current Status,Rectifiers Current Value,Rectifiers Capacity Status,Rectifiers Capacity Value,Rectifiers Error Status,Rectifiers Temperature Value,Rectifiers Temperature Status,Rectifier Status.[SP2-MIB :: rectifiersCurrentStatus : 1.3.6.1.4.1.12148.10.5.2.1.0,rectifiersCurrentValue : 1.3.6.1.4.1.12148.10.5.2.5.0,rectifiersCapacityStatus : 1.3.6.1.4.1.12148.10.5.3.1.0,rectifiersCapacityValue : 1.3.6.1.4.1.12148.10.5.3.5.0,rectifiersErrorStatus : 1.3.6.1.4.1.12148.10.5.4.1.0,rectifiersTemperatureValue : 1.3.6.1.4.1.12148.10.5.18.5.0,rectifiersTemperatureStatus : 1.3.6.1.4.1.12148.10.5.18.1.0,rectifierStatus : 1.3.6.1.4.1.12148.10.5.6.1.2,rectifierStatus : 1.3.6.1.4.1.12148.10.5.6.1.2]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Rectifiers | eltek_eNexus_rectifiers_RectifiersTemperatureStatus | Eltek eNexus Rectifiers Temperature Status | Monitors the state of the rectifier temperature can be either one of the defined enumerated values.[SP2-MIB :: rectifiersTemperatureStatus : 1.3.6.1.4.1.12148.10.5.18.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | |
eltek_eNexus_rectifiers_RectifiersCapacityValue | Eltek eNexus Rectifiers Capacity Value | % | Monitors the used rectifier capacity value presented in percentage of the total installed rectifier capacity.[SP2-MIB :: rectifiersCapacityValue : 1.3.6.1.4.1.12148.10.5.3.5.0]. | |
eltek_eNexus_rectifiers_RectifiersErrorStatus | Eltek eNexus Rectifiers Error Status | Monitors the status value shows if the number of failed units is higher than the defined alarm level.[SP2-MIB :: rectifiersErrorStatus : 1.3.6.1.4.1.12148.10.5.4.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_rectifiers_RectifiersCurrentStatus | Eltek eNexus Rectifiers Current Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: rectifiersCurrentStatus : 1.3.6.1.4.1.12148.10.5.2.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) . | ||
eltek_eNexus_rectifiers_RectifiersCurrentValue | Eltek eNexus Rectifiers Current Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: rectifiersCurrentValue : 1.3.6.1.4.1.12148.10.5.2.5.0] | |
eltek_eNexus_rectifiers_RectifiersCapacityStatus | Eltek eNexus Rectifiers Capacity Status | Monitors the status of the measured used rectifier capacity.[SP2-MIB :: rectifiersCapacityStatus : 1.3.6.1.4.1.12148.10.5.3.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_rectifiers_RectifiersTemperatureValue | Eltek eNexus Rectifiers Temperature Value | Celsius | Monitors the highest value of the rectifier temperature measurements.[SP2-MIB :: rectifiersTemperatureValue : 1.3.6.1.4.1.12148.10.5.18.5.0] | |
Eltek eNexus - Rectifiers Status | eltek_eNexus_rectifiers_RectifierStatus | Eltek eNexus Rectifier Status | Monitors the overall status of rectifier.[SP2-MIB :: rectifierStatus : 1.3.6.1.4.1.12148.10.5.6.1.2].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). |
Eltek eNexus - Rectiverters
Description
Monitors the Eltek eNexus rectiverters parameters like Rectiverters Dc Current Status,Rectiverters Dc Current Value,Rectiverters Error Status,Rectiverters Temperature Status,Rectiverters Temperature Value,Rectiverters Ac Out Current1 Status,Rectiverters Ac Out Current1 Value,Rectiverters Ac Out Current2 Status,Rectiverters Ac Out Current2 Value,Rectiverters Ac Out Current3 Status,Rectiverters Ac Out Current3 Value,Rectiverters Ac Out Voltage1 Status,Rectiverters Ac Out Voltage1 Value,Rectiverters Ac Out Voltage2 Status,Rectiverters Ac Out Voltage2 Value,Rectiverters Ac Out Voltage3 Status,Rectiverters Ac Out Voltage3 Value,Rectiverters Ac Frequency Deviation Status,Rectiverters Ac Frequency Deviation Value,Rectiverters Ac Frequency.[SP2-MIB :: rectivertersDcCurrentStatus : 1.3.6.1.4.1.12148.10.18.2.1.0,rectivertersDcCurrentValue : 1.3.6.1.4.1.12148.10.18.2.5.0,rectivertersErrorStatus : 1.3.6.1.4.1.12148.10.18.3.1.0,rectivertersTemperatureStatus : 1.3.6.1.4.1.12148.10.18.4.1.0,rectivertersTemperatureValue : 1.3.6.1.4.1.12148.10.18.4.5.0,rectivertersAcOutCurrent1Status : 1.3.6.1.4.1.12148.10.18.5.1.0,rectivertersAcOutCurrent1Value : 1.3.6.1.4.1.12148.10.18.5.5.0,rectivertersAcOutCurrent2Status : 1.3.6.1.4.1.12148.10.18.6.1.0,rectivertersAcOutCurrent2Value : 1.3.6.1.4.1.12148.10.18.6.5.0,rectivertersAcOutCurrent3Status : 1.3.6.1.4.1.12148.10.18.7.1.0,rectivertersAcOutCurrent3Value : 1.3.6.1.4.1.12148.10.18.7.5.0,rectivertersAcOutVoltage1Status : 1.3.6.1.4.1.12148.10.18.8.1.0,rectivertersAcOutVoltage1Value : 1.3.6.1.4.1.12148.10.18.8.5.0,rectivertersAcOutVoltage2Status : 1.3.6.1.4.1.12148.10.18.9.1.0,rectivertersAcOutVoltage2Value : 1.3.6.1.4.1.12148.10.18.9.5.0,rectivertersAcOutVoltage3Status : 1.3.6.1.4.1.12148.10.18.10.1.0,rectivertersAcOutVoltage3Value : 1.3.6.1.4.1.12148.10.18.10.5.0,rectivertersAcFrequencyDeviationStatus : 1.3.6.1.4.1.12148.10.18.11.1.0,rectivertersAcFrequencyDeviationValue : 1.3.6.1.4.1.12148.10.18.11.5.0,rectivertersAcFrequency : 1.3.6.1.4.1.12148.10.18.12.0]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Rectiverters | eltek_eNexus_RectivertersAcOutCurrent1Value | Eltek eNexus Rectiverters Ac Out Current1 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutCurrent1Value : 1.3.6.1.4.1.12148.10.18.5.5.0]. |
eltek_eNexus_RectivertersDcCurrentValue | Eltek eNexus Rectiverters Dc Current Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: rectivertersDcCurrentValue : 1.3.6.1.4.1.12148.10.18.2.5.0]. | |
eltek_eNexus_RectivertersAcOutVoltage3Status | Eltek eNexus Rectiverters Ac Out Voltage3 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutVoltage3Status : 1.3.6.1.4.1.12148.10.18.10.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_RectivertersAcOutCurrent2Value | Eltek eNexus Rectiverters Ac Out Current2 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutCurrent2Value : 1.3.6.1.4.1.12148.10.18.6.5.0] | |
eltek_eNexus_RectivertersAcOutCurrent3Value | Eltek eNexus Rectiverters Ac Out Current3 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutCurrent3Value : 1.3.6.1.4.1.12148.10.18.7.5.0]. | |
eltek_eNexus_RectivertersAcOutCurrent1Status | Eltek eNexus Rectiverters Ac Out Current1 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutCurrent1Status : 1.3.6.1.4.1.12148.10.18.5.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_RectivertersErrorStatus | Eltek eNexus Rectiverters Error Status | Monitors the rectiverters error status.[SP2-MIB :: rectivertersErrorStatus : 1.3.6.1.4.1.12148.10.18.3.1.0] | ||
eltek_eNexus_RectivertersTemperatureValue | Eltek eNexus Rectiverters Temperature Value | Celsius | Monitors the highest value of the rectifier temperature measurements.[SP2-MIB :: rectivertersTemperatureValue : 1.3.6.1.4.1.12148.10.18.4.5.0] | |
eltek_eNexus_RectivertersAcOutVoltage1Status | Eltek eNexus Rectiverters Ac Out Voltage1 Status | Monitors the value of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutVoltage1Status : 1.3.6.1.4.1.12148.10.18.8.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_RectivertersAcOutVoltage3Value | Eltek eNexus Rectiverters Ac Out Voltage3 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutVoltage3Value : 1.3.6.1.4.1.12148.10.18.10.5.0] | |
eltek_eNexus_RectivertersAcOutCurrent2Status | Eltek eNexus Rectiverters Ac Out Current2 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutCurrent2Status : 1.3.6.1.4.1.12148.10.18.6.1.0] | ||
eltek_eNexus_RectivertersAcFrequencyDeviationValue | Eltek eNexus Rectiverters Ac Frequency Deviation Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: rectivertersAcFrequencyDeviationValue : 1.3.6.1.4.1.12148.10.18.11.5.0] | |
eltek_eNexus_RectivertersAcOutVoltage2Status | Eltek eNexus Rectiverters Ac Out Voltage2 Status | Monitor the status of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutVoltage2Status : 1.3.6.1.4.1.12148.10.18.9.1.0] | ||
eltek_eNexus_RectivertersDcCurrentStatus | Eltek eNexus Rectiverters Dc Current Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: rectivertersDcCurrentStatus : 1.3.6.1.4.1.12148.10.18.2.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_RectivertersAcOutVoltage2Value | Eltek eNexus Rectiverters Ac Out Voltage2 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutVoltage2Value : 1.3.6.1.4.1.12148.10.18.9.5.0] | |
eltek_eNexus_RectivertersAcOutVoltage1Value | Eltek eNexus Rectiverters Ac Out Voltage1 Value | amps | Monitors the value of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutVoltage1Value : 1.3.6.1.4.1.12148.10.18.8.5.0] | |
eltek_eNexus_RectivertersAcFrequencyDeviationStatus | Eltek eNexus Rectiverters Ac Frequency Deviation Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: rectivertersAcFrequencyDeviationStatus : 1.3.6.1.4.1.12148.10.18.11.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_RectivertersAcFrequency | Eltek eNexus Rectiverters Ac Frequency | Hz | Monitors the Eltek eNexus rectiverters Ac frequency.[SP2-MIB :: rectivertersAcFrequency : 1.3.6.1.4.1.12148.10.18.12.0]. | |
eltek_eNexus_RectivertersAcOutCurrent3Status | Eltek eNexus Rectiverters Ac Out Current3 Status | Monitors the status of the measured total rectifier current.[SP2-MIB :: rectivertersAcOutCurrent3Status : 1.3.6.1.4.1.12148.10.18.7.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). | ||
eltek_eNexus_RectivertersTemperatureStatus | Eltek eNexus Rectiverters Temperature Status | Monitors the state of the rectifier temperature.[SP2-MIB :: rectivertersTemperatureStatus : 1.3.6.1.4.1.12148.10.18.4.1.0].Possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19). |
Eltek eNexus - Solar Chargers
Description
Monitors the Eltek eNexus solar chargers parameters like Solar Chargers Current Status,Solar Chargers Error Status,Solar Chargers Current Value,Solar Chargers Earth Fault Status.[SP2-MIB :: solarChargersCurrentStatus : 1.3.6.1.4.1.12148.10.7.2.1.0,solarChargersErrorStatus : 1.3.6.1.4.1.12148.10.7.4.1.0,solarChargersCurrentValue : 1.3.6.1.4.1.12148.10.7.2.5.0,solarChargersEarthFaultStatus : 1.3.6.1.4.1.12148.10.7.8.0]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - Solar Chargers | eltek_eNexus_solarchargers_SolarChargersEarthFaultStatus | Eltek eNexus Solar Chargers Earth Fault Status | Monitors the status of solar charger's Earth Fault monitor.[SP2-MIB :: solarChargersEarthFaultStatus : 1.3.6.1.4.1.12148.10.7.8.0] | |
eltek_eNexus_solarchargers_SolarChargersCurrentStatus | Eltek eNexus Solar Chargers Current Status | monitors the status of the measured total solar current.[SP2-MIB :: solarChargersCurrentStatus : 1.3.6.1.4.1.12148.10.7.2.1.0] | ||
eltek_eNexus_solarchargers_SolarChargersErrorStatus | Eltek eNexus Solar Chargers Error Status | Monitors the status value shows if the number of failed units is higher than the defined alarm level.[SP2-MIB :: solarChargersErrorStatus : 1.3.6.1.4.1.12148.10.7.4.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | ||
eltek_eNexus_solarchargers_SolarChargersCurrentValue | Eltek eNexus Solar Chargers Current Value | amps | monitors the value of the measured total solar current.[SP2-MIB :: solarChargersCurrentValue : 1.3.6.1.4.1.12148.10.7.2.5.0] |
Eltek eNexus - Wind Chargers
Description
Monitors the Eltek eNexus wind chargers parameters like Wind Chargers Current Status,Wind Chargers Current Value,Wind Chargers Error Status.[SP2-MIB :: windChargersCurrentStatus : 1.3.6.1.4.1.12148.10.8.2.1.0,windChargersCurrentValue : 1.3.6.1.4.1.12148.10.8.2.5.0,windChargersErrorStatus : 1.3.6.1.4.1.12148.10.8.4.1.0]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Eltek eNexus - WindChargers | eltek_eNexus_windchargers_WindChargersErrorStatus | Eltek eNexus Wind Chargers Error Status | Monitors the status value shows if the number of failed units is higher than the defined alarm level.[SP2-MIB :: windChargersErrorStatus : 1.3.6.1.4.1.12148.10.8.4.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) | |
eltek_eNexus_windchargers_WindChargersCurrentStatus | Eltek eNexus Wind Chargers Current Status | Monitors the status of the measured total wind current.[SP2-MIB :: windChargersCurrentStatus : 1.3.6.1.4.1.12148.10.8.2.1.0].possible values are error(0),normal(1),minorAlarm(2),majorAlarm(3),disabled(4),disconnected(5),notPresent(6),minorAndMajor(7),majorLow(8),minorLow(9),majorHigh(10),minorHigh(11),event(12),valueVolt(13),valueAmp(14),valueTemp(15),valueUnit(16),valuePerCent(17),critical(18),warning(19) . | ||
eltek_eNexus_windchargers_WindChargersCurrentValue | Eltek eNexus Wind Chargers Current Value | amps | Monitors the value of the measured total wind current.[SP2-MIB :: windChargersCurrentValue : 1.3.6.1.4.1.12148.10.8.2.5.0]. |