Denso - IoT Data Server - Controller Status

Description

Template to monitor Denso IoT Data server controller status. Possible status values are undefined(-1),uninit(0),active(1),deactive(2),error(3),threadTerminated(4),threadConnectTimeoutWaiting(5),threadSamplingThreadWaiting(6). And we have to “Manually select controller instance on the device” because of multiple Controller instances. So while assigning this program as a template on a device,it will ask user to provide Controller instance numbers as a input (with comma separated). Example: 1,2,50,100,150,200,250. If user didn’t provided any Controller instance numbers then it will monitor “All” Controllers (from 1 to 255) by default.[IOTDS-MIB OIDs: controller1-status - 1.3.6.1.4.1.24296.2.1.2.0 to controller255-status - 1.3.6.1.4.1.24296.2.255.2.0]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Denso - IoT Data Server - Controller Statusdenso.iot.dataserver.controller.statusIoT Data Server Controller StatusMonitors Denso IoT Data server controller status.[OID: 1.3.6.1.4.1.24296.2.1.2.0 to 1.3.6.1.4.1.24296.2.255.2.0]

Denso - IoT Data Server - Controller Status - V2

Description

Template to monitor IoT Data server controller status. Possible status values are undefined(-1),uninit(0),active(1),deactive(2),error(3),threadTerminated(4),threadConnectTimeoutWaiting(5),threadSamplingThreadWaiting(6). And we have to “Manually select controller instance on the device” because of multiple Controller instances. So while assigning this program as a template on a device,it will ask user to provide Controller instance numbers as a input (with comma separated). Example: 1,2,50,100,150,200,250. If user didnot provided any Controller instance numbers then it will monitor “All” Controllers (from 1 to 255) by default.[IOTDS-MIB OIDs: controller1-status - 1.3.6.1.4.1.24296.2.1.2.0 to controller255-status - 1.3.6.1.4.1.24296.2.255.2.0]. it also gets version and serial number and have those in description.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Denso - IoT Data Server - Controller Status - V2denso.iot.dataserver.controller.statusIoT Data Server Controller StatusMonitors Denso IoT Data server controller status.[OID: 1.3.6.1.4.1.24296.2.1.2.0 to 1.3.6.1.4.1.24296.2.255.2.0]

Denso - IoT Data Server - System and Project Status

Description

Template to monitor Denso IoT Data Server status metrics like System status and Project Status.[IOTDS-MIB::system-status - 1.3.6.1.4.1.24296.1.2.0,project-status - 1.3.6.1.4.1.24296.1.1.0]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Denso - IoT Data Server - System and Project Statusdenso.iot.dataserver.statusIoT Data Server StatusMonitors IoT Data Server Status.[IOTDS-MIB OID: 1.3.6.1.4.1.24296.1.2]
denso.iot.dataserver.project.statusIoT Data Server Project StatusMonitors IoT Data Server project status.[IOTDS-MIB OID: 1.3.6.1.4.1.24296.1.1]