Dell ADVA Ensemble Virtual Edge - Performance

Description

Monitors the Dell ADVA Ensemble Virtual Edge Performance Statistics like CPU Load Average In 5 Minutes, Cpu Utilization and Memory Usage.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCpuLoadAverage5Min : 1.3.6.1.4.1.7950.3.11.1.2.5.1.7, advaENSCPUUtilization : 1.3.6.1.4.1.7950.3.11.1.2.9.1.10, advaENSMemoryUsage : 1.3.6.1.4.1.7950.3.11.1.2.9.1.3]

Prerequisites

Device must have support for ADVA-ENS-SYSTEM-INVENTORY-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell ADVA Ensemble Virtual Edge - CPU Loaddell_advaENS_CpuLoadAverage5MinDell AdvaENS CPU Load Average 5MinutesIt monitors the dell AdvaENS CPU Load Average in the last 5 minutes period.[ADVA-ENS-SYSTEM-INVENTORY-MIB -MIB :: advaENSCpuLoadAverage5Min : 1.3.6.1.4.1.7950.3.11.1.2.5.1.7]
Dell ADVA Ensemble Virtual Edge - File Systemdell_advaENS_FileSystemUtilizationDell AdvaENS File System Utilization%Monitors the dell advaENS File System Utilization.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemUse : 1.3.6.1.4.1.7950.3.11.1.2.8.1.6]
dell_advaENS_FileSystemUsedDell AdvaENS File System UsedMBMonitors the dell AdvaENS File System Used [ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemUsed : 1.3.6.1.4.1.7950.3.11.1.2.8.1.4]
dell_advaENS_FileSystemAvailableDell AdvaENS File System AvailableMBMonitors the dell AdvaENS File System Available.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemAvailable : 1.3.6.1.4.1.7950.3.11.1.2.8.1.5]
Dell ADVA Ensemble Virtual Edge - Memory Usagedell_advaENS_MemoryUsageDell advaENS Memory Usage%Monitors the dell advaENS percent of Memory Usage.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSMemoryUsage : 1.3.6.1.4.1.7950.3.11.1.2.9.1.3]
Dell ADVA Ensemble Virtual Edge - CPU Utilizationdell_advaENS_CpuUtilizationDell AdvaENS CPU Utilization%Monitors the dell AdvaENS CPU Utilization.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCPUUtilization : 1.3.6.1.4.1.7950.3.11.1.2.9.1.10]

Dell ADVA Ensemble Virtual Edge - Hardware

Description

Monitors the Dell ADVA Ensemble Virtual Edge Hardware Metrics like Current Temperature, Temperature Status, Current Voltage, Voltage Status, Current Tx Power, Tx Power Status, Current Rx Power, Rx Power Status.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.12, advaENSSFPTempStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.13, advaENSSFPVoltageCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.16, advaENSSFPVoltageStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.17, advaENSSFPTxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.24, advaENSSFPTxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.25, advaENSSFPRxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.28, advaENSSFPRxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.29]

Prerequisites

Device must have support for ADVA-ENS-SYSTEM-INVENTORY-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell ADVA Ensemble Virtual Edge - Hardwaredell_advaENS_SFPTempCurrentDell AdvaENS SFP Temperature CurrentCelsiusMonitors the dell AdvaENS SFP Temperature Current.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.12]
dell_advaENS_SFPTempStatusDell AdvaENS SFPTemperature StatusMonitors the dell AdvaENS SFP Temperature Status. Alert will be generated when SFP Temperature Status is "NOT OK".[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.13]
dell_advaENS_SFPVoltageCurrentDell AdvaENS SFP Voltage CurrentvMonitors the dell AdvaENS SFP Voltage Current.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPVoltageCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.16]
dell_advaENS_SFPVoltageStatusDell AdvaENS SFP Voltage StatusMonitors the dell AdvaENS SFP Voltage Status. Alert will be generated when SFP Voltage Status is "NOT OK".[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPVoltageStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.17]
dell_advaENS_SFPTxPowerCurrentDell AdvaENS SFP Tx Power CurrentdBmMonitors the dell AdvaENS SFP Tx Power Current.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.24]
dell_advaENS_SFPTxPowerStatusDell AdvaENS SFP Tx Power StatusMonitors the dell AdvaENS SFP Tx Power Status. Alert will be generated when SFP Tx Power Status is "NOT OK".[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.25]
dell_advaENS_SFPRxPowerCurrentDell AdvaENS SFP Rx Power CurrentdBmMonitors the dell AdvaENS SFP Rx Power Current.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPRxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.28]
dell_advaENS_SFPRxPowerStatusDell AdvaENS SFP Rx Power StatusMonitors the dell AdvaENS SFP Rx Power Status. Alert will be generated when SFP Rx Power Status.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPRxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.29]

Dell ADVA Ensemble Virtual Edge - Vnf

Description

Monitors the Dell ADVA Ensemble Virtual Edge Vnf Metrics like Operational Status, Vnf State, Memory Usage and Vnf Port Operational Status. [ADVA-ENS-VNF-MIB :: advaENSVnfStateOper : 1.3.6.1.4.1.7950.3.11.8.1.3.1.12, advaENSVnfState : 1.3.6.1.4.1.7950.3.11.8.1.3.1.3, advaENSVnfStateMemorUsage : 1.3.6.1.4.1.7950.3.11.8.1.3.1.13, advaENSVnfPortStateOper : 1.3.6.1.4.1.7950.3.11.8.1.5.1.9]

Prerequisites

Device must have support for ADVA-ENS-VNF-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell ADVA Ensemble Virtual Edge - Vnfdell_advaENS_VnfStateDell AdvaENS Vnf StateMonitors the dell advaENS Vnf State.Possible values are 1: shutdown, 2: running, 3: crashed, 4: failed, 5: paused, 6: unknown. [ADVA-ENS-VNF-MIB :: advaENSVnfState : 1.3.6.1.4.1.7950.3.11.8.1.3.1.3]
dell_advaENS_VnfStateOperDell AdvaENS Vnf Operational StatusMonitors the dell AdvaENS Vnf Operational Status. [ADVA-ENS-VNF-MIB :: advaENSVnfStateOper : 1.3.6.1.4.1.7950.3.11.8.1.3.1.12]
dell_advaENS_VnfStateMemorUsageDell advaENS Vnf State Memory UsageMonitors the dell AdvaENS Vnf percentage memory usage. [ADVA-ENS-VNF-MIB :: advaENSVnfStateMemorUsage : 1.3.6.1.4.1.7950.3.11.8.1.3.1.13]
Dell ADVA Ensemble Virtual Edge - Vnf Port Statedell_advaENS_VnfPortStateOperDell AdvaENS Vnf Port Operational StatusMonitors the dell AdvaENS Vnf Port Operational Status. [ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSVnfPortStateOper : 1.3.6.1.4.1.7950.3.11.8.1.5.1.9]

Dell ADVA Ensemble Virtual Edge - Sensor Ext

Description

Monitor the Dell ADVA Ensemble Virtual Edge Sensor Metrics like Temperature, Power and Fan. [ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2 ]

Prerequisites

Device must have support for ADVA-LM-SENSORS-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell ADVA Ensemble Virtual Edge - Sensor Extdell_advaENS_TemperatureDell AdvaENS TemperatureCelsiusMonitors the dell AdvaENS Temperature. [ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2]
dell_advaENS_FanDell AdvaENS FanrpmMonitors the dell AdvaENS Fan Status. [ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2]
dell_advaENS_PowerDell AdvaENS PowervMonitors the dell AdvaENS Power in Volts. [ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2]

Dell - CRC Errors

Description

Template to monitor Dell CRC errors. Delta = Previous value of f10IfInCRC is subtracted from Current value of f10IfInCRC.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell - CRC Errors - Deltadell.crc.errorsCRC ErrorsIt monitors the total number of frames received that had a length (ex-cluding framing bits,but including FCS octets) of between 64 and 1518 octets,inclusive,but had a bad CRC. And this metric will provide CRC errors delta (Previous value of dellNetIfInCRC is subtracted from current dellNetIfInCRC value).[DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfInCRC - 1.3.6.1.4.1.6027.3.11.1.2.1.1.11]

Dell Compellent SAN Monitors

Description

Applicable on Compellent SAN devices. Monitors the Hardware parameters like Battery,FAN,Power etc.. along with the Disk,enclosure,manageed server details,volume and Storage center status etc..

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell Compellent SAN - Cache and Battery Statusdell.compellent.controller.battery.statusBattery StatusProvides the controller cache battery status. Possible Values are 0-noBattery,1-normal,2-expirationPending,3-expired.[OID:1.3.6.1.4.1.16139.2.28.1.5]
dell.compellent.controller.cache.statusCache StatusProvides the controller cache status. Possible Values are 1-Up,2-Down,3-Degraded [OID: 1.3.6.1.4.1.16139.2.28.1.3]
DELL Compellent SAN - Controller Statusdell.compellent.controller.statusController StatusProvides the controller status. possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.13.1.3]
Dell Compellent SAN - Controller Temperature Sensor Statusdell.compellent.temperature.statusTemperature Status
Dell Compellent SAN - Count Objectsdell.compellent.device.countDevice CountProvides the Device Count.[OID: 1.3.6.1.4.1.16139.2.31.1.3]
dell.compellent.replay.countReplay CountProvides the Replay Count.[OID: 1.3.6.1.4.1.16139.2.31.1.4]
dell.compellent.number.disksNumber of DisksProvides the Number of Disks.[OID: 1.3.6.1.4.1.16139.2.31.1.5].
dell.compellent.count.serversCount of ServersProvides the Count of Servers.[OID: 1.3.6.1.4.1.16139.2.31.1.6].
dell.compellent.count.volumesCount of VolumesProvides the Count of Volumes.[OID: 1.3.6.1.4.1.16139.2.31.1.7].
DELL Compellent SAN - Disk Folder Statusdell.compellent.disk.folder.statusDisk Folder StatusProvides the Disk folder status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.25.1.3]
DELL Compellent SAN - Disk Statusdell.compellent.disk.statusDisk StatusProvides the Disk Status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.14.1.3]
dell.compellent.disk.healthDisk HealthProvides the Disk Health. Possible value is 1- True indicates that the disk is healthy. 2-False indicates that the disk not healthy.[OID: 1.3.6.1.4.1.16139.2.14.1.5]
Dell Compellent SAN - Enclosure Audible Alarm Statusdell.compellent.enclosure.alarm.statusEnclosure Audible Alarm StatusProvides the Enclosure Audible Alarm Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.24.1.3].
Dell Compellent SAN - Enclosure Fan Statusdell.compellent.enclosure.fan.statusEnclosure Fan StatusProvides the Enclosure Fan Status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.20.1.3]
Dell Compellent SAN - Enclosure Module Statusdell.compellent.enclosure.module.statusEnclosure Module StatusProvides the Enclosure I/O Module Status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.22.1.3]
Dell Compellent SAN - Enclosure Power Supply Statusdell.compellent.enclosure.power.statusEnclosure Power StatusProvides the enclosure power supply status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.21.1.3]
Dell Compellent SAN - Enclosure Statusdell.compellent.enclosure.statusEnclosure StatusProvides the Enclosure Status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.15.1.3]
Dell Compellent SAN - Enclosure Temperature Sensor Statusdell.compellent.enclosure.temperature.statusEnclosure Temperature StatusProvides the enclosure temperature sensor status. Possible values are 1-up 2-down 3-degraded.[OID: 1.3.6.1.4.1.16139.2.23.1.3]
Dell Compellent SAN - Fan Statusdell.compellent.fan.statusFan StatusProvides the Fan Status. Possible values are 1-up 2-down 3-degraded.[OID: 1.3.6.1.4.1.16139.2.16.1.3]
Dell Compellent SAN - Managed Server Statusdell.compellent.managed.server.statusManaged Server StatusProvides the Managed Server Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.27.1.3].
Dell Compellent SAN - Managed UPS Statusdell.compellent.monitored.ups.statusMonitored UPS StatusProvides the Monitored UPS Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.30.1.3].
Dell Compellent SAN - Power Statusdell.compellent.power.statusPower StatusProvides the Power Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.17.1.3].
Dell Compellent SAN - Product Global Statusdell.compellent.global.statusGlobal StatusMonitors the current status of the product. This is a rollup for the entire product including any monitored devices. The status is intended to give initiative to an SNMP monitor to get further data when this status is abnormal. The value here maps from the System Status icon on the SC GUI: grey->unknown,green->ok,yellow->noncritical,red->critical. Possible values are 1-other 2-unkown 3-ok 4-noncritical 5-critical 6-nonrecoverable.[OID: 1.3.6.1.4.1.16139.2.6.0]
Dell Compellent SAN - Storage Center Statusdell.compellent.storage.center.statusStorage Center StatusProvides the Storage Center Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.29.1.3]
Dell Compellent SAN - Volume Statusdell.compellent.volume.statusVolume StatusProvides the Volume Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.26.1.3].

Dell Compellent Storage Center SAN

Description

Applicable on Compellent SAN devices. Monitors the Hardware parameters like Battery,FAN,Power etc.. along with the Disk,enclosure,manageed server details,volume and Storage center status etc..

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
DELL Compellent SAN - Disk Folder Storage Usagedell.compellent.disk.folder.space.usedDisk Folder Space UsedGBIt represents the Disk Folder Storage Usage used space,in GB (1,073,741,824). Matches 'Allocated space used by volumes' on SC GUI.[OIDs: 1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.6]
dell.compellent.disk.folder.space.utilizationDisk Folder Space Utilization%Represents the Disk Folder Storage Usage space utilization,in percentage. dell.compellent.disk.folder.space.utilization = ((scDiskFolderSUUsedSpace2 * 100) / scDiskFolderSUTotalSpace2).[OIDs: 1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.5,1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.6]
dell.compellent.disk.folder.space.freeDisk Folder Space FreeGBDisk Folder Storage Usage free space,in GB (1,073,741,824). scDiskFolderSUFreeSpace = scDiskFolderSUTotalSpace2 - scDiskFolderSUAllocSpace - scDiskFolderSUUsedSpace2. Matches 'Unallocated disk space' on SC GUI.[OIDs: 1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.8,1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.7,1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.6,1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.5]
Dell Compellent Storage Center SAN - Power Statusdell_compellent_sc_san_CtlrPowerStatusDell Compellent SC San Power Supply StatusProvides the Power Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scCtlrPowerStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.3]
Dell Compellent Storage Center SAN - Volume Statusdell_compellent_sc_san_VolumeStatusDell Compellent SC San Volume StatusProvides the Volume Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scVolumeStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.26.1.3]
Dell Compellent Storage Center SAN - Cache and Battery Statusdell_compellent_sc_san_CacheBatStatusDell Compellent SC San Cache Battery StatusProvides the controller cache battery status. Possible Values are 0-noBattery,1-normal,2-expirationPending,3-expired.[DELL-STORAGE-SC-MIB :: scCacheBatStat : 1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.5]
dell_compellent_sc_san_CacheStatusDell Compellent SC San Cache StatusProvides the controller cache status. Possible Values are 1-Up,2-Down,3-Degraded .[DELL-STORAGE-SC-MIB :: scCacheStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.3]
Dell Compellent Storage Center SAN - Controller Statusdell_compellent_sc_san_CtlrStatusDell Compellent SC San Controller StatusProvides the controller status. possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scCtlrStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.3]
Dell Compellent Storage Center SAN - Controller Temperature Sensor Statusdell_compellent_sc_san_CtlrTempStatusDell Compellent SC San Controller Temp StatusProvides the Temperature Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scCtlrTempStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.3]
Dell Compellent Storage Center SAN - Count Objectsdell_compellent_sc_san_ObjCntServersDell Compellent SC San Servers CountcountProvides the Count of Servers.[DELL-STORAGE-SC-MIB :: scObjCntServers : 1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.6]
dell_compellent_sc_san_ObjCntDevsInUseDell Compellent SC San Device CountcountProvides the Device Count.[DELL-STORAGE-SC-MIB :: scObjCntDevsInUse : 1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.3]
dell_compellent_sc_san_ObjCntVolumesDell Compellent SC San Volumes CountcountProvides the Count of Volumes.[DELL-STORAGE-SC-MIB :: scObjCntVolumes : 1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.7]
dell_compellent_sc_san_ObjCntReplaysDell Compellent SC San Replay CountcountProvides the numbers of replays count.[DELL-STORAGE-SC-MIB :: scObjCntReplays : 1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.4]
dell_compellent_sc_san_ObjCntDisksDell Compellent SC San Disks CountcountProvides the number of disks.[DELL-STORAGE-SC-MIB :: scObjCntDisks : 1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.5]
Dell Compellent Storage Center SAN - Disk Folder Statusdell_compellent_sc_san_DiskFolderStatusDell Compellent SC San Disk Folder StatusProvides the Disk folder status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scDiskFolderStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.3]
Dell Compellent Storage Center SAN - Disk Statusdell_compellent_sc_san_DiskStatusDell Compellent SC San Disk StatusProvides the Disk Status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scDiskStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.3]
dell_compellent_sc_san_DiskHealthyDell Compellent SC San Disk HealthProvides the Disk Health. Possible value is 1- True indicates that the disk is healthy. 2-False indicates that the disk not healthy.[DELL-STORAGE-SC-MIB :: scDiskHealthy : 1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.5]
Dell Compellent Storage Center SAN - Enclosure Audible Alarm Statusdell_compellent_sc_san_EnclAlarmStatusEnclosure Audible Alarm StatusProvides the Enclosure Audible Alarm Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scEnclAlarmStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.24.1.3]
Dell Compellent Storage Center SAN - Enclosure Fan Statusdell_compellent_sc_san_EnclFanStatusDell Compellent SC San Enclosure Fan StatusProvides the Enclosure Fan Status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scEnclFanStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.20.1.3]
Dell Compellent Storage Center SAN - Enclosure Module Statusdell_compellent_sc_san_EnclIoModStatusDell Compellent SC San Enclosure Module StatusProvides the Enclosure I/O Module Status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scEnclIoModStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.22.1.3]
Dell Compellent Storage Center SAN - Enclosure Power Supply Statusdell_compellent_sc_san_EnclPowerStatusDell Compellent SC San Enclosure Power StatusProvides the enclosure power supply status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scEnclPowerStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.21.1.3]
Dell Compellent Storage Center SAN - Enclosure Statusdell_compellent_sc_san_EnclStatusDell Compellent SC San Enclosure StatusMonitors the enclosure status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scEnclStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.3]
Dell Compellent Storage Center SAN - Enclosure Temperature Sensor Statusdell_compellent_sc_san_EnclTempStatusDell Compellent SC San Enclosure Temp StatusProvides the enclosure temperature sensor status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scEnclTempStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.23.1.3]
Dell Compellent Storage Center SAN - Fan Statusdell_compellent_sc_san_CtlrFanStatusDell Compellent SC San Fan StatusProvides the Fan Status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scCtlrFanStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.3,scCtlrFanCurrentRpm : 1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.5]
Dell Compellent Storage Center SAN - Managed Server Statusdell_compellent_sc_san_ServerStatusDell Compellent SC San Managed Server StatusProvides the Managed Server Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scServerStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.27.1.3]
Dell Compellent Storage Center SAN - Managed UPS Statusdell_compellent_sc_san_UPSStatusDell Compellent SC San UPS StatusProvides the Monitored UPS Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scUPSStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.30.1.3]
Dell Compellent Storage Center SAN - Product Global Statusdell_compellent_sc_san_ProductIDGlobalStatusDell Compellent SC San Global StatusMonitors the current status of the product. This is a rollup for the entire product including any monitored devices. The status is intended to give initiative to an SNMP monitor to get further data when this status is abnormal. The value here maps from the System Status icon on the SC GUI: grey->unknown,green->ok,yellow->noncritical,red->critical. Possible values are 1-other 2-unkown 3-ok 4-noncritical 5-critical 6-nonrecoverable.[DELL-STORAGE-SC-MIB :: productIDGlobalStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.6.0]
Dell Compellent Storage Center SAN - Storage Center Statusdell_compellent_sc_san_ScStatusDell Compellent SC San Storage Center StatusProvides the Storage Center Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scScStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.3]

Dell DRAC Status - G2

Description

Applicable on Dell Power edge M1000e Rack system. Monitors the components like chassis status,fan,power,IOM,temperature etc.,

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell DRAC Hardware Status Monitorsdell.drac.temperature.sensor.statusDell DRAC temperature Sensor StatusTemp Sensor subsystem health status. Possible values are 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.8.0]
dell.drac.fan.statusDell DRAC Fan StatusFan subsystem health status - This system has 9(8+1 redundant) Fan modules. Any single fan can fail without impacting system uptime or reliability. In the event of a fan failure,system behavior is dependent on the resultant temperatures of the system,as monitored by the Server Module iDRAC and I/O Modules. The CMC continues to interpret the airflow needs of each server and I/O module to control the fan speeds appropriately. The system will not ramp the fans to full speed in the event of a fan failure unless deemed necessary by on-board monitoring. Failure of more than one fan will not automatically result in shutting down of blade servers. This is because the blade servers have their own self-protection mechanisms to prevent them from running too hot. The result of a failure of multiple fans would depend on the configuration,ambient temperature,and workload being run. Possible values 1- Other,2 - Unknown,3 - OK,4 - Noncritical,5 - Critical,6 - Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.6.0]
dell.drac.iom.module.statusDell DRAC IOM Module StatusIOM Status - IOM subsystem status. The chassis can hold up to six I/O modules (IOMs). Possible values 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.2.0]
dell.drac.cmc.statusDell DRAC CMC StatusCMC health status -Chassis Management Controller (CMC). The system normally has 2 CMC,CMC -1 is standard and CMC-2 provides optional redundancy. Possible values 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.9.0]
dell.drac.redundancy.statusDell DRAC Redundancy StatusStatus of the redundancy subsystem. Possible values 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.4.0]
dell.drac.kvm.statusDell DRAC KVM StatusIntegrated Keyboard/Video/Mouse (iKVM) switch KVM subsystem health status. Possible values are 1 -Other,2 -Unknown,3 -OK,4 -Noncritical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.3.0]
dell.drac.power.statusDell DRAC Power StatusPower Subsystem Health Status - The system has 6 Power modules. If the system has this configuration then the system will provide protection against AC grid loss or power supply failures. If one power grid fails,three power supplies lose their AC source,and the three power supplies on the other grid remain powered,providing sufficient power for the system to continue running. In the N+1 configuration only power supply failures are protected,not grid failures. The likelihood of multiple power supplies failing at the same time is remote. In the N+0 configuration there is no power protection and any protection must be provided at the node or chassis level. Possible values 1- Other,2 - Unknown,3 - OK,4 - Noncritical,5 - Critical,6 - Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.5.0]
dell.drac.blade.statusDell DRAC Blade StatusBlade subsystem health status. Possible values 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.7.0]
dell.global.current.statusGlobal Current StatusProvides the global status. This attribute defines the overall chassis status being monitored by the chassis management card.DellStatus 1- Other,2-Unknown,3- Ok,4- Non Critical,5-Critical,6- Non Recoverable. Alert is generated when the current vale not equal to OK and previous vale is equal to OK.[OID: 1.3.6.1.4.1.674.10892.2.3.1.1].
Dell DRAC Statusdell.drac.statusDell DRAC StatusChassis Status - defines the overall chassis status being monitored by the chassis management card. Possible values 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.2.1.0]

Dell EMC Data Domain

Description

Template to monitor Dell EMC Data Domain (sysObjectID : 1.3.6.1.4.1.19746.3.1.34) file system space parameters like file system percent used,file system resource tier,file system space size,file system space used,compression parameters like file system reduction percent 1,file system pre compression size,file system post compression size,file system status,replication information parameters like replication file system status,replication pre compression bytes remaining,replication synced as of time,replication state,replication status,replication configuration like replication configuration enabled,system availability and system Fs availability,boost status,CIFS status,network file system status,VTL administration state,VTL process state,fan status and fan level,power module status,temperature sensor status and temperature sensor current value. (Data Domain OS 7.4.0.5-671629)

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell EMC Data Domain - Fan Statusdell_EMCdatadomain_FanStatusFan StatusIt monitors the current status of the fan. Possible values are notfound(0),ok(1),fail(2).[DATA-DOMAIN-MIB::fanStatus:1.3.6.1.4.1.19746.1.1.3.1.1.1.6].
dell_EMCdatadomain_FanLevelFan Current Run LevelIt monitors the current run level of fan. Possible values are unknown(0),low(1),medium(2),high(3).[DATA-DOMAIN-MIB::fanLevel:1.3.6.1.4.1.19746.1.1.3.1.1.1.5].
Dell EMC Data Domain - File System Compressiondell_EMCdatadomain_FileSystemPreCompressionSizeFile System Pre Compression SizeGBIt monitors the size of the file system pre compression in gigabytes.[DATA-DOMAIN-MIB::fileSystemPreCompressionSize:1.3.6.1.4.1.19746.1.3.3.1.1.5].
dell_EMCdatadomain_FileSystemReductionPercent1File System Reduction Percent%It monitors the file system reduction percent.[DATA-DOMAIN-MIB::fileSystemReductionPercent1:1.3.6.1.4.1.19746.1.3.3.1.1.11].
dell_EMCdatadomain_FileSystemPostCompressionSizeFile System Post Compression SizeGBIt monitors the size of the file system post compression in gigabytes.[DATA-DOMAIN-MIB::fileSystemPostCompressionSize:1.3.6.1.4.1.19746.1.3.3.1.1.6].
Dell EMC Data Domain - File System Spacedell_EMCdatadomain_FileSystemResourceTierFile System Resource TierIt monitors the tier that a resource belongs to,such as active or archive.[DATA-DOMAIN-MIB::fileSystemResourceTier:1.3.6.1.4.1.19746.1.3.2.1.1.9].
dell_EMCdatadomain_FileSystemSpaceSizeFile System Space SizeGBIt monitors the size of the file system resource in gigabytes.[DATA-DOMAIN-MIB::fileSystemSpaceSize:1.3.6.1.4.1.19746.1.3.2.1.1.4].
dell_EMCdatadomain_FileSystemPercentUsedFile System Percent Used%It monitors the percentage of used space within the file system resource.[DATA-DOMAIN-MIB::fileSystemPercentUsed:1.3.6.1.4.1.19746.1.3.2.1.1.7].
dell_EMCdatadomain_FileSystemSpaceUsedFile System Space UsedGBIt monitors the amount of used space within the file system resource in gigabytes.[DATA-DOMAIN-MIB::fileSystemSpaceUsed:1.3.6.1.4.1.19746.1.3.2.1.1.5].
Dell EMC Data Domain - File System Statusdell_EMCdatadomain_FileSystemStatusFile System StatusIt monitors the status of the file system. Possible values are enabled(1),disabled(2),running(3),unknown(4),error(5),cleaning(6),starting(7).[DATA-DOMAIN-MIB::fileSystemStatus:1.3.6.1.4.1.19746.1.3.1.1.0].
Dell EMC Data Domain - Power Module Statusdell_EMCdatadomain_PowerModuleStatusPower Module StatusIt monitors the current enclosure power module status. Possible values are absent(0),ok(1),failed(2),faulty(3),acnone(4),unknown(99).[DATA-DOMAIN-MIB::powerModuleStatus:1.3.6.1.4.1.19746.1.1.1.1.1.1.4].
Dell EMC Data Domain - Replication Configurationdell_EMCdatadomain_ReplicationConfigurationEnabledReplication Configuration EnabledIt monitors the replication configuration enabled. Possible values are no(0),yes(1).[DATA-DOMAIN-MIB::replConfigEnabled:1.3.6.1.4.1.19746.1.8.2.1.1.8,replConfigDest:1.3.6.1.4.1.19746.1.8.2.1.1.4,replConfigSource:1.3.6.1.4.1.19746.1.8.2.1.1.3].
Dell EMC Data Domain - Replication Information-V2dell_EMCdatadomain_ReplicationStatusReplication StatusIt monitors the status of replication source/dest pair connection. Possible values are connected(1),disconnected(2),migrating(3),suspended(4),neverConnected(5),idle(6).[DATA-DOMAIN-MIB::replStatus:1.3.6.1.4.1.19746.1.8.1.1.1.4,replDestination:1.3.6.1.4.1.19746.1.8.1.1.1.8,replSource:1.3.6.1.4.1.19746.1.8.1.1.1.7].
dell_EMCdatadomain_ReplicationSyncedTimeReplication Synced TimemsIt monitors the time when the source and destination were in sync,or 0 if the time is unknown.[DATA-DOMAIN-MIB::replSyncedAsOfTime:1.3.6.1.4.1.19746.1.8.1.1.1.14,replDestination:1.3.6.1.4.1.19746.1.8.1.1.1.8,replSource:1.3.6.1.4.1.19746.1.8.1.1.1.7].
dell_EMCdatadomain_ReplicationStateReplication StateIt monitors the state of replication source/dest pair. Possible values are initializing(1),normal(2),recovering(3),uninitialized(4).[DATA-DOMAIN-MIB::replState:1.3.6.1.4.1.19746.1.8.1.1.1.3,replDestination:1.3.6.1.4.1.19746.1.8.1.1.1.8,replSource:1.3.6.1.4.1.19746.1.8.1.1.1.7].
dell_EMCdatadomain_ReplicationPreCompressionBytesRemainingReplication Pre Compression Bytes RemainingBytesIt monitors the pre compression bytes remaining.[DATA-DOMAIN-MIB::replPreCompBytesRemaining:1.3.6.1.4.1.19746.1.8.1.1.1.11,replDestination:1.3.6.1.4.1.19746.1.8.1.1.1.8,replSource:1.3.6.1.4.1.19746.1.8.1.1.1.7].
dell_EMCdatadomain_ReplicationFileSystemStatusReplication File System StatusIt monitors the status of filesystem. Possible values are enabled(1),disabled(2),running(3),unknown(4),error(5),cleaning(6),starting(7).[DATA-DOMAIN-MIB::replFileSysStatus:1.3.6.1.4.1.19746.1.8.1.1.1.5,replDestination:1.3.6.1.4.1.19746.1.8.1.1.1.8,replSource:1.3.6.1.4.1.19746.1.8.1.1.1.7].
Dell EMC Data Domain - Statusdell_EMCdatadomain_VTLprocessStateVTL Process StateIt monitors the state of VTL process. Possible values are unknown(0),stopped(1),starting(2),running(3),timingout(4),stopping(5),stuck(6).[DATA-DOMAIN-MIB::vtlProcessState:1.3.6.1.4.1.19746.1.11.1.2.0].
dell_EMCdatadomain_CIFSstatusCIFS StatusIt monitors the CIFS status. Possible values are enabled(1),enabledRunning(2),enabledNotRunning(3),enabledWindbindNotRun(4),disabled(5).[DATA-DOMAIN-MIB::cifsStatus:1.3.6.1.4.1.19746.1.10.1.1.0].
dell_EMCdatadomain_DataDomainBoostStatusData Domain Boost StatusIt monitors the status of the Data Domain Boost interface group on a Data Domain system. Possible values are enabled(1),disabled(2).[DATA-DOMAIN-MIB::ddboostStatus:1.3.6.1.4.1.19746.1.12.1.1.0].
dell_EMCdatadomain_VTLadministrationStateVTL Administration StateIt monitors the state of VTL administration. Possible values are unknown(0),enabled(1),disabled(2),failed(3).[DATA-DOMAIN-MIB::vtlAdminState:1.3.6.1.4.1.19746.1.11.1.1.0].
dell_EMCdatadomain_NetworkFileSystemStatusNetwork File System StatusIt monitors the status of the network file system. Possible values are enabled(1),disabled(2).[DATA-DOMAIN-MIB::nfsStatus:1.3.6.1.4.1.19746.1.9.1.1.0].
Dell EMC Data Domain - System Availabilitydell_EMCdatadomain_SystemFsAvailabilitySystem Fs Availability%It monitors the system Fs availability.[DATA-DOMAIN-MIB::systemFsAvailability:1.3.6.1.4.1.19746.1.13.1.10.0].
dell_EMCdatadomain_SystemAvailabilitySystem Availability%It monitors the system availability.[DATA-DOMAIN-MIB::systemAvailability:1.3.6.1.4.1.19746.1.13.1.8.0].
Dell EMC Data Domain -Temperature Sensor Statusdell_EMCdatadomain_TemperatureSensorStatusTemperature Sensor StatusIt monitors the current status of the sensor. Possible values are failed(0),ok(1),notfound(2),overheatWarning(3),overheatCritical(4).[DATA-DOMAIN-MIB::tempSensorStatus:1.3.6.1.4.1.19746.1.1.2.1.1.1.6].
dell_EMCdatadomain_TemperatureSensorCurrentValueTemperature Sensor Current ValueCelsiusIt monitors the current Temperature Value of the sensor.[DATA-DOMAIN-MIB::tempSensorCurrentValue:1.3.6.1.4.1.19746.1.1.2.1.1.1.5].

Dell Emc Power Switch Os10 - Hardware

Description

Templates to monitor Dell Emc power switch Os10 hardware parameters like Chassis Temparature,Card Operational Status,Card Temparature,Power Supply Operational Status,Fan Tray Operational Status,Fan Operational Status.[DELLEMC-OS10-CHASSIS-MIB :: os10ChassisTemp : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11,os10CardStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.4,os10CardTemp : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.5,os10PowerSupplyOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4,os10FanTrayOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.4,os10FanOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell Emc Power Switch Os10 - Carddell_emc_powerswitch_Os10CardTempDell Emc Power Switch Os10 Card TemparatureCMonitors the temperature of the card in degrees Centigrade [DELLEMC-OS10-CHASSIS-MIB :: os10CardTemp : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.5]
dell_emc_powerswitch_Os10CardStatusDell Emc Power Switch Os10 Card Operational StatusMonitors the current operational state of the card. Possible values are ready(1),cardMisMatch(2),cardProblem(3),diagMode(4),cardAbsent(5),offline(6).[DELLEMC-OS10-CHASSIS-MIB :: os10CardStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.4]
Dell Emc Power Switch Os10 - Chassis Temperaturedell_emc_powerswitch_Os10ChassisTempDell Emc Power Switch Os10 Chassis TemperatureCMonitors the temperature of the chassis [DELLEMC-OS10-CHASSIS-MIB :: os10ChassisTemp : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11]
Dell Emc Power Switch Os10 - Fan Statusdell_emc_powerswitch_os10FanOperStatusDell Emc Power Switch Os10 Fan Operational StatusMonitors the status of the fan.Possible values are up(1),down(2),testing(3),unknown(4),dormant(5),notPresent(6),lowerLayerDown(7),failed(8).[DELLEMC-OS10-CHASSIS-MIB :: os10FanOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7]
Dell Emc Power Switch Os10 - Fan Tray Statusdell_emc_powerswitch_Os10FanTrayOperStatusDell Emc Power Switch Os10 Fan Tray Operational StatusMonitors the status of the fan tray. Possible values are Possible values are up(1),down(2),testing(3),unknown(4),dormant(5),notPresent(6),lowerLayerDown(7),failed(8).[DELLEMC-OS10-CHASSIS-MIB :: os10FanTrayOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.4]
Dell Emc Power Switch Os10 - Power Supply Statusdell_emc_powerswitch_Os10PowerSupplyOperStatusDell Emc Power Switch Power Supply Os10 Operational StatusMonitors the status of the power supply. Possible values are Possible values are up(1),down(2),testing(3),unknown(4),dormant(5),notPresent(6),lowerLayerDown(7),failed(8).[DELLEMC-OS10-CHASSIS-MIB :: os10PowerSupplyOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4]

DELL Equallogic Monitors - G2

Description

Applicable on EqualLogic SAN devices. Monitors the disk Status,disk performance,Controller Battery Status,Volume status,Group and Member performance and storage etc.,

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell EqualLogic Controller Batterycontroller.battery.statusController Battery StatusMonitors the controller battery status. Possible values are 1- ok,2- failed,3- good-battery-is-charging,4- low-voltage-status,5- low-voltage-is-charging,6- missing-battery.[OID: 1.3.6.1.4.1.12740.4.1.1.1.5]
controller.nvrambattery.statusController NVRAM Battery StatusMonitors the status of NVRAM Battery on CM. Possible values are 0- not-present,1- good,2- bad,3- unknown.[OID: 1.3.6.1.4.1.12740.4.1.1.1.32]
Dell EqualLogic Disk Monitorssystem.disk.busy.timeDisk Busy TimesMonitors the disk time in seconds spent busy.[OIDs: 1.3.6.1.4.1.12740.3.1.2.1.4,1.3.6.1.4.1.12740.3.1.1.1.10,1.3.6.1.4.1.12740.3.1.1.1.11]
system.disk.io.operations.currentDisk IO Operations CurrentMonitors the number of IO operations currently outstanding.[OID: 1.3.6.1.4.1.12740.3.1.2.1.5]
system.disk.transfers.failedDisk Transfers FailedMonitors the number of failed transfers.[OID: 1.3.6.1.4.1.12740.3.1.2.1.6]
system.disk.statusDisk StatusMonitors the equallogic disk status. Possible status values are 1- on-line: the disk is being used in the raid set,2- spare: disk is not currently being used by raid configuration but may be used when status of a currently on-line disk changes,3- failed: either disk is faulted or when there is no power,4- off-line: disk doesn't fall into any of these other categories,5- alt-sig: disk belongs to a RAIDset from another EqualLogic system. The disk can be converted to a spare,6- too-small: drive is too small to be used. The drive cannot be converted to spare,7- history-of-failures: drive has a history of failures. The drive can be converted to spare,8- unsupported-version: drive label is from a later release. The drive can be converted to spare,9- unhealthy: drive is unhealthy,10- replacement: drive is a replacement drive,11- encrypted: drive is encrypted and cannot be decrypted,12- notApproved: drive is not DELL approved,13- preempt-failed: drive is off-line due to excessive errors.[OID: 1.3.6.1.4.1.12740.3.1.1.1.8]
Dell Equallogic Group Monitorsequallogic.group.storagepool.free.percentStorage Pool Free Space Percent%Monitors the free space percent of the Storage Pool.[OIDs: 1.3.6.1.4.1.12740.1.1.1.1.19,1.3.6.1.4.1.12740.1.1.1.1.20,1.3.6.1.4.1.12740.1.1.2.1.1,1.3.6.1.4.1.12740.1.1.2.1.2,1.3.6.1.4.1.12740.1.1.2.1.4,1.3.6.1.4.1.12740.1.1.2.1.15]
equallogic.group.members.onlineOnline MembersMonitors the number of group members which are online.[OID: 1.3.6.1.4.1.12740.1.1.2.1.3]
equallogic.group.members.totalTotal MembersMonitors the total number of members in this group irrelevant of current member state.[OID: 1.3.6.1.4.1.12740.1.1.2.1.13]
equallogic.group.members.inuseMembers In UseMonitors the total number of online+offline members in this group.[OID: 1.3.6.1.4.1.12740.1.1.2.1.14]
DELL EqualLogic Member Fanequallogic.member.fanMember Fan StatusMonitors the state of the fan. Possible values are 0- unknown,1- normal,2- warning,3- critical.[OIDs: 1.3.6.1.4.1.12740.2.1.7.1.2,1.3.6.1.4.1.12740.2.1.7.1.3,1.3.6.1.4.1.12740.2.1.7.1.4]
DELL EqualLogic Member Monitorsequallogic.member.storage.utilizationMember Storage Utilization%Monitors the equallogic member storage utilization.[OIDs: 1.3.6.1.4.1.12740.2.1.1.1.9,1.3.6.1.4.1.12740.2.1.10.1.1,1.3.6.1.4.1.12740.2.1.10.1.2,1.3.6.1.4.1.12740.2.1.10.1.3,1.3.6.1.4.1.12740.2.1.10.1.4]
equallogic.member.storage.totalMember Storage TotalMBMonitors the total disk storage in MBs on the array.[OID: 1.3.6.1.4.1.12740.2.1.10.1.1]
equallogic.member.storage.usedMember Storage UsedMBMonitors the storage used ie.,sum of reserved delegated space,reserved volume space,used snapshot space,used replication space.[OID: 1.3.6.1.4.1.12740.2.1.10.1.2]
equallogic.member.raid.statusMember Raid StatusMonitors the status of the raid subsystem. This is a composite of the view of the underlying subsystems. Possible values are 1- ok,2- degraded: in a degraded state,possible because no spare is available,3- verifying: a verify pass is run,and a percent complete is available,4- reconstructing: reconstructing a drive and a percent complete is available,5- a failure while we were up,possibly a drive failed and we have no spare,6- catastrophicLoss: may not be visible to the user since the member may not be able to bootup. It means we need administrator intervention to correct the problem,7- expanding,8- mirroring: mirroring a bad drive onto a spare drive.[OID: 1.3.6.1.4.1.12740.2.1.13.1.1]
equallogic.member.read.latencyMember Read LatencymsMonitors the average latency for read operations on this member in milli seconds. The value is reset to zero upon reboot.[OID: 1.3.6.1.4.1.12740.2.1.12.1.4]
equallogic.member.write.latencyMember Write LatencymsMonitors the average latency for write operations on this member in milli seconds. The value is reset to zero upon reboot.[OID: 1.3.6.1.4.1.12740.2.1.12.1.5]
equallogic.member.iscsi.connectionsMember iSCSI ConnectionsMonitors the number of iSCSI connections made from initiators to this array.[OID: 1.3.6.1.4.1.12740.2.1.12.1.1]
equallogic.member.healthMember HealthMonitors the equallogic member health. Possible values are 0 - Unknown,1 - Normal,2 - Warning,3 - Critical.[OID: 1.3.6.1.4.1.12740.2.1.5.1.1]
DELL EqualLogic Member Power Supplyequallogic.member.powerMember Power Supply StatusMonitors the state of the power supply. Possible values are 1- on-and-operating,2- no-ac-power,3- failed-or-no-data.[OIDs: 1.3.6.1.4.1.12740.2.1.8.1.2,1.3.6.1.4.1.12740.2.1.8.1.3,1.3.6.1.4.1.12740.2.1.8.1.4]
DELL EqualLogic Member Temperatureequallogic.member.temperatureMember TemperatureCMonitors the temperature in degrees C.[OID: 1.3.6.1.4.1.12740.2.1.6.1.3,1.3.6.1.4.1.12740.2.1.6.1.2]
equallogic.member.temperature.statusMember Temperature StatusMonitors the state of the temperature sensor. Possible values are 0- unknown,1- normal,2- warning,3- critical.[OID: 1.3.6.1.4.1.12740.2.1.6.1.4]
DELL EqualLogic Storage Poolequallogic.replication.storagespace.usedStorage Replication Space Utilization%Monitors the percentage of space is currently utilized by replication in this storage pool.[OIDs: 1.3.6.1.4.1.12740.16.1.1.1.3,1.3.6.1.4.1.12740.16.1.2.1.4,1.3.6.1.4.1.12740.16.1.2.1.5,1.3.6.1.4.1.12740.16.1.2.1.6]
equallogic.storagespace.usedStorage Pool Space Utilization%Monitors the percentage of the space used by volumes in this pool.[OIDs: 1.3.6.1.4.1.12740.16.1.1.1.3,1.3.6.1.4.1.12740.16.1.2.1.1,1.3.6.1.4.1.12740.16.1.2.1.2,1.3.6.1.4.1.12740.16.1.2.1.3]
equallogic.storagespace.freeStorage Pool Space Free Percent%Monitors the percentage of space is available in this storage pool.[OIDs: 1.3.6.1.4.1.12740.16.1.1.1.3,1.3.6.1.4.1.12740.16.1.2.1.1,1.3.6.1.4.1.12740.16.1.2.1.2,1.3.6.1.4.1.12740.16.1.2.1.3]
Dell EqualLogic Volume Replication Statusvolume.replication.statusVolume Replication StatusMonitors the the current operational status of the replication process. Possible status values are 1- Disabled,2- In Progress,3- Waiting,4- Far End Down,5- Auth Failure,6- Completed,7- Paused,8- Remote Resize Failed,9- Remote Paused,10- Partner Paused Local,11- Failed,12- Remote ReplReserveLow,13- Nomoresnapallowed,14- Remote Repl Reserve Invalid,15- Cancelling,16- Pending Data Transfer,17- Manual Data Transfer InProgress,18- Remote Disallow DowngradesNotSet,19- Remote Partner Needs Upgrade.[OIDs: 1.3.6.1.4.1.12740.5.1.7.15.1.3,1.3.6.1.4.1.12740.5.1.7.15.1.2,1.3.6.1.4.1.12740.5.1.7.16.1.1]
DELL EqualLogic Volume Statussystem.volume.statusVolume StatusMonitors the current operational status of the volume.[OIDs: 1.3.6.1.4.1.12740.5.1.7.7.1.8,1.3.6.1.4.1.12740.5.1.7.1.1.8,1.3.6.1.4.1.12740.5.1.7.1.1.4]

Dell Force10 Chassis

Description

Template to monitor Dell Force10 products which have support for F10-CHASSIS-MIB. Validated on Dell Force10 OS Operating System Version: 1.0 Application Software Version: 8.4.1.6 Series: E1200i . SysObjId=1.3.6.1.4.1.6027.1.1.5

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell Force10 Chassis - Fan Tray Statusdell.force10.chassis.fan.tray.statusFan Tray StatusIt monitors the status of the fan tray. Possible values are up(1),down(2).[F10-CHASSIS-MIB::chSysFanTrayOperStatus : 1.3.6.1.4.1.6027.3.1.1.2.2.1.2].
Dell Force10 Chassis - Power Supply Statusdell.force10.chassis.power.supply.statusPower Supply StatusIt monitors the status of the power supply .Possible values are up(1),down(2).[F10-CHASSIS-MIB::chSysPowerSupplyOperStatus : 1.3.6.1.4.1.6027.3.1.1.2.1.1.2].
Dell Force10 Chassis - RPM Performancedell.force10.chassis.rpm.mem.usageRPM Memory Usage%It monitors the total RPM's memory usage in percentage.[F10-CHASSIS-MIB::chRpmMemUsageUtil : 1.3.6.1.4.1.6027.3.1.1.3.7.1.6].
dell.force10.chassis.rpm.cpu.usage.5minRPM CPU Usage 5Min%It monitors the CPU utilization of RPM in percentage for last 5 minutes.[F10-CHASSIS-MIB::chRpmCpuUtil5Min : 1.3.6.1.4.1.6027.3.1.1.3.7.1.5].
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

Dell - Force10 M Series Monitors

Description

Applicable on Dell Force 10 M series devices. Monitors CPU and memory utilization on the stack units and also it monitors environmental parameters such as power,temperature and fan. Tested on m-MXL (SysObjID: 1.3.6.1.4.1.6027.1.4.1)

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell Force10 Stack Unit Fan Status - M Seriesdell.force10.unit.fan.statusUnit fan statusStatus of the Fan tray units. Possible values are 1 - Up,2 - Down
Dell Force10 Stack Unit Monitors - M Seriesdell.force10.stack.unit.statusStack Unit StatusThe current status of the unit. Possible values are 1 - OK,2 - Unsupported,3 - Code mistmatch,4 - Config mismatch,5 - Unit down,6 - Not present.
dell.force10.unit.temperatureUnit temperatureCThe temperature of the stack unit.
Dell Force10 Stack Unit Performance Monitor - M Seriessystem.cpu.utilizationCPU Utilization%CPU utilization in percentage for last 5 minutes.
system.memory.util.percentMemory Utilization%Total memory usage in percentage.[OID: 1.3.6.1.4.1.6027.3.19.1.2.8.1.5]
Dell Force10 Stack Unit Power Supply - M Seriesdell.force10.unit.power.supplyUnit power supplyPower supply status of the unit. Possible values are 1 - normal,2 - warning,3 - critical,4 - shutdown,5 - notPresent,6 - notFunctioning.
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

Dell - Force10 S Series Monitors

Description

Applicable on Dell Force 10 switch S series. Monitors environmental parameters such as power,temperature and fan. Also checks CPU and memory utilization on the stack units. Tested on S55 switch.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell Force10 Stack Unit Fan Status - S seriesdell.force10.unit.fan.statusUnit fan statusStatus of the Fan tray units. Possible values are 1 - Up,2 - Down [OID: 1.3.6.1.4.1.6027.3.10.1.2.4.1.2]
Dell Force10 Stack Unit Monitors - S Seriesdell.force10.stack.unit.statusStack Unit StatusThe current status of the unit. Possible values are 1 - OK,2 - Unsupported,3 - Code mistmatch,4 - Config mismatch,5 - Unit down,6 - Not present [OID: 1.3.6.1.4.1.6027.3.10.1.2.2.1.8,1.3.6.1.4.1.6027.3.10.1.2.2.1.2]
dell.force10.unit.temperatureUnit temperatureCThe temperature of the stack unit [OID: 1.3.6.1.4.1.6027.3.10.1.2.2.1.2,1.3.6.1.4.1.6027.3.10.1.2.2.1.14]
Dell Force10 Stack Unit Performance Monitor - S Seriessystem.cpu.utilizationCPU Utilization%CPU utilization in percentage for last 5 minutes.[OID: 1.3.6.1.4.1.6027.3.10.1.2.9.1.1,1.3.6.1.4.1.6027.3.10.1.2.9.1.4]
system.memory.util.percentMemory Utilization%Total memory usage in percentage.[OID: 1.3.6.1.4.1.6027.3.10.1.2.9.1.5,1.3.6.1.4.1.6027.3.10.1.2.7.1.4,1.3.6.1.4.1.6027.3.10.1.2.7.1.3]
Dell Force10 Stack Unit Power Supply - S Seriesdell.force10.unit.power.supplyUnit power supplyPower supply status of the unit. Possible values are 1 - Up,2 - Down [OID: 1.3.6.1.4.1.6027.3.10.1.2.3.1.2,1.3.6.1.4.1.6027.3.10.1.2.3.1.3]
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

Dell Force10 System Uptime

Description

Monitors the elapsed time(seconds) from the Chassis Bootup Time. i.e System uptime. It is supported by VG v2.7.0 and above.[OID: 1.3.6.1.4.1.6027.3.6.1.1.1.0]

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell Force10 System Uptimedell.force10.system.uptimeUPTIMEsMonitors the elapsed time(seconds) from the Chassis Bootup Time. i.e System uptime.[OID: 1.3.6.1.4.1.6027.3.6.1.1.1.0]

Dell iDRAC Monitors

Description

Template for Dell iDRAC. Monitors Global storage status,global system status,LCD status and power status. Virtual Disk,Physical Disk,Memory(DIMMs),CPU,Power Supply,Power Unit,Fan,Battery,Temperature Sensor,BIOS,Voltage,Amperage etc. Tested on Dell iDRAC PowerEdge R620 device.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell iDRAC Amperage Reading in Ampsdell.idrac.amperage.reading.ampsAmperage Reading in AmpsampsRepresents the power usage that the probe is reading in Amps. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6]
Dell iDRAC Amperage Reading in Milliampsdell.idrac.amperage.reading.milliampsAmperage Reading in MilliampsmARepresents the power usage that the probe is reading in Milliamps. It monitors only when amperageProbeType is other than amperageProbeTypeIsDiscrete,amperageProbeTypeIsPowerSupplyAmps,amperageProbeTypeIsPowerSupplyWatts,amperageProbeTypeIsSystemAmps or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6]
Dell iDRAC Amperage Reading in Wattsdell.idrac.amperage.reading.wattsAmperage Reading in WattsWRepresents the power usage that the probe is reading in Watts. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyWatts or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6]
Dell iDRAC Amperage Statusdell.idrac.amperage.probe.statusAmperage Probe StatusRepresents the probe status of the amperage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.5]
Dell iDRAC Chassis Statusdell.idrac.system.chassis.statusChassis StatusRepresents the status of the system chassis.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.10.1.4,1.3.6.1.4.1.674.10892.5.4.300.10.1.7]
Dell iDRAC CPU Statusdell.idrac.cpu.statusCPU StatusMonitors the status of the processor device status probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6,1.3.6.1.4.1.674.10892.5.4.1100.32.1.7,1.3.6.1.4.1.674.10892.5.4.1100.30.1.5,1.3.6.1.4.1.674.10892.5.4.1100.30.1.8]
Dell iDRAC Enclosure Power Suppliesdell.idrac.enclosure.powersupplies.statusEnclosures Power SuppliesMonitors the status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other,2: Unknown,3: OK,4: Non-critical,5: Critical,6: Non-recoverable.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9]
Dell iDRAC Fan Readingdell.idrac.fan.speedFan SpeedrpmRepresents the reading for a cooling device of subtypes (coolingDeviceSubTypeIsAFanThatReadsInRPM and coolingDeviceSubTypeIsAPowerSupplyFanThatReadsinRPM) [OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.6]
Dell iDRAC Fan Statusdell.idrac.fan.statusFan StatusRepresents the status of the probe status of the cooling device/fan.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.12.1.2,1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8]
Dell iDRAC Intrusion Statusdell.idrac.intrusion.readingIntrusion Sensor ReadingIt represents the intrusion reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.8]
dell.idrac.intrusion.statusIntrusion Sensor StatusThe status of the intrusion sensor.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.5,1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.7,1.3.6.1.4.1.674.10892.5.4.300.70.1.8]
Dell iDRAC Memory(DIMMs) Statusdell.idrac.memory.statusMemory (DIMMs) StatusRepresents the status of the memory(DIMMs).[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5,1.3.6.1.4.1.674.10892.5.4.1100.50.1.8,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14]
Dell iDRAC Physical Disk Statusdell.idrac.phydisk.statusPhysical Disk StatusThe current state of this physical disk. Possible states - 1: unknown - The current state could not be determined. 2: ready - The physical disk is available for use,but no RAID configuration has been assigned. 3: online - A RAID configuration has been assigned to the physical disk. 4: foreign - The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: offline - The physical disk is not available to the RAID controller. 6: blocked - The physical disk is currently blocked by controller. 7: failed - The physical disk is not operational. 8: non-raid - The physical disk is not a RAID capable disk 9: removed - The physical disk has been removed.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4]
dell.idrac.phydisk.smart.statusPhysical Disk Smart StatusMonitors whether the physical disk has received a predictive failure alert or not. Possible values are 0(False),1(True). It generates alert if it is True.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31]
Dell iDRAC Power Supply Statusdell.idrac.powersupply.statusPower Supply StatusMonitors the status of the power supply.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.7,1.3.6.1.4.1.674.10892.5.4.600.12.1.8,1.3.6.1.4.1.674.10892.5.4.600.12.1.11,1.3.6.1.4.1.674.10892.5.4.600.12.1.12]
Dell iDRAC System Battery Statusdell.idrac.system.battery.readingBattery ReadingIt represents the battery reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7]
dell.idrac.system.battery.statusBattery StatusIt represents the status of the battery.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.5,1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7]
Dell iDRAC System BIOS Statusdell.idrac.system.bios.statusBIOS StatusRepresents the status of the system BIOS.[OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5]
Dell iDRAC System Statsdell.idrac.global.system.statusGlobal System StatusIndicates the overall rollup status of all components in the system being monitored by the remote access card. Includes system,storage,IO devices,iDRAC,CPU,memory,etc. Possible status values are 1- Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6-nonRecoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.1.0]
dell.idrac.system.lcd.statusLCD StatusIndicates the system status as it is reflected by the LCD front panel. Not all system components may be included. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.2.0]
dell.idrac.global.storage.statusGlobal Storage StatusIndicates the overall storage status being monitored by the remote access card. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.3.0]
dell.idrac.system.power.statePower StateIndicates the power state of the system. Possible status values are 1: Other,2- Unknown,3- Off,4- On.[OID: 1.3.6.1.4.1.674.10892.5.2.4.0]
Dell iDRAC Temperaturedell.idrac.temperature.readingTemperature ReadingCIt represents the reading for a temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.8]
dell.idrac.temperature.statusTemperature StatusIt represents the probe status of the temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.7,1.3.6.1.4.1.674.10892.5.4.700.20.1.8]
Dell iDRAC Virtual Disk Statusdell.idrac.virtual.disk.statusVirtual Disk StatusRepresents the current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.3]
dell.idrac.virtual.disk.badblocksis Virtual Disk has Bad Blocks ?Indicates whether the virtual disk has bad blocks.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23]
Dell iDRAC Voltagedell.idrac.voltage.prob.readingVoltage Probe ReadingvMonitors the power supply voltage probe reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.20.1.6,1.3.6.1.4.1.674.10892.5.4.600.20.1.8]
dell.idrac.voltage.prob.statusVoltage Probe StatusRepresents the probe status of the voltage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.5]

Dell iDRAC Monitors - v2

Description

Additional metrics(cooling system status,power supply status,processor status) support added to existing template(Dell iDRAC Monitors) for Dell iDRAC. Monitors Global storage status,global system status,LCD status and power status. Virtual Disk,Physical Disk,Memory(DIMMs),CPU,Power Supply,Power Unit,Fan,Battery,Temperature Sensor,BIOS,Voltage,Amperage,. Tested on Dell iDRAC PowerEdge R720 and R620 devices.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell iDRAC Amperage Reading in Ampsdell.idrac.amperage.reading.ampsAmperage Reading in AmpsampsRepresents the power usage that the probe is reading in Amps. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6]
Dell iDRAC Amperage Reading in Milliampsdell.idrac.amperage.reading.milliampsAmperage Reading in MilliampsmARepresents the power usage that the probe is reading in Milliamps. It monitors only when amperageProbeType is other than amperageProbeTypeIsDiscrete,amperageProbeTypeIsPowerSupplyAmps,amperageProbeTypeIsPowerSupplyWatts,amperageProbeTypeIsSystemAmps or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6]
Dell iDRAC Amperage Reading in Wattsdell.idrac.amperage.reading.wattsAmperage Reading in WattsWRepresents the power usage that the probe is reading in Watts. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyWatts or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6]
Dell iDRAC Amperage Statusdell.idrac.amperage.probe.statusAmperage Probe StatusRepresents the probe status of the amperage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.5]
Dell iDRAC Chassis Statusdell.idrac.system.chassis.statusChassis StatusRepresents the status of the system chassis.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.10.1.4,1.3.6.1.4.1.674.10892.5.4.300.10.1.7]
Dell iDRAC CPU Statusdell.idrac.cpu.statusCPU StatusMonitors the status of the processor device status probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6,1.3.6.1.4.1.674.10892.5.4.1100.32.1.7,1.3.6.1.4.1.674.10892.5.4.1100.30.1.5,1.3.6.1.4.1.674.10892.5.4.1100.30.1.8]
Dell iDRAC Enclosure Power Suppliesdell.idrac.enclosure.powersupplies.statusEnclosures Power SuppliesMonitors the status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other,2: Unknown,3: OK,4: Non-critical,5: Critical,6: Non-recoverable.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9]
Dell iDRAC Fan Readingdell.idrac.fan.speedFan SpeedrpmRepresents the reading for a cooling device of subtypes (coolingDeviceSubTypeIsAFanThatReadsInRPM and coolingDeviceSubTypeIsAPowerSupplyFanThatReadsinRPM) [OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.6]
Dell iDRAC Fan Statusdell.idrac.fan.statusFan StatusRepresents the status of the probe status of the cooling device/fan.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.12.1.2,1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8]
Dell iDRAC Intrusion Statusdell.idrac.intrusion.readingIntrusion Sensor ReadingIt represents the intrusion reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.8]
dell.idrac.intrusion.statusIntrusion Sensor StatusThe status of the intrusion sensor.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.5,1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.7,1.3.6.1.4.1.674.10892.5.4.300.70.1.8]
Dell iDRAC Memory(DIMMs) Statusdell.idrac.memory.statusMemory (DIMMs) StatusRepresents the status of the memory(DIMMs).[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5,1.3.6.1.4.1.674.10892.5.4.1100.50.1.8,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14]
Dell iDRAC Physical Disk Statusdell.idrac.phydisk.statusPhysical Disk StatusThe current state of this physical disk. Possible states - 1: unknown - The current state could not be determined. 2: ready - The physical disk is available for use,but no RAID configuration has been assigned. 3: online - A RAID configuration has been assigned to the physical disk. 4: foreign - The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: offline - The physical disk is not available to the RAID controller. 6: blocked - The physical disk is currently blocked by controller. 7: failed - The physical disk is not operational. 8: non-raid - The physical disk is not a RAID capable disk 9: removed - The physical disk has been removed.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4]
dell.idrac.phydisk.smart.statusPhysical Disk Smart StatusMonitors whether the physical disk has received a predictive failure alert or not. Possible values are 0(False),1(True). It generates alert if it is True.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31]
Dell iDRAC Power Supply Statusdell.idrac.powersupply.statusPower Supply StatusMonitors the status of the power supply.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.7,1.3.6.1.4.1.674.10892.5.4.600.12.1.8,1.3.6.1.4.1.674.10892.5.4.600.12.1.11,1.3.6.1.4.1.674.10892.5.4.600.12.1.12]
Dell iDRAC System Battery Statusdell.idrac.system.battery.readingBattery ReadingIt represents the battery reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7]
dell.idrac.system.battery.statusBattery StatusIt represents the status of the battery.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.5,1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7]
Dell iDRAC System BIOS Statusdell.idrac.system.bios.statusBIOS StatusRepresents the status of the system BIOS.[OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5]
Dell iDRAC System Hardware Statusdell_idrac_SystemStateCoolingDeviceStatusDell iDRAC System Cooling Device StatusMonitors the dell idrac cooling system status.[IDRAC-MIB::systemStateCoolingDeviceStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.21].Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6).
dell_idrac_SystemStateProcessorDeviceStatusDell iDRAC System Processor Device StatusMonitors the dell idrac processor status.[IDRAC-MIB::systemStateProcessorDeviceStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.50].Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6) .
dell_idrac_SystemStatePowerUnitStatusDell iDRAC System Power Unit StatusMonitors the dell idrac power supply status.[IDRAC-MIB::systemStatePowerUnitStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.42].Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6).
Dell iDRAC System Statsdell.idrac.system.lcd.statusLCD StatusIndicates the system status as it is reflected by the LCD front panel. Not all system components may be included. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.2.0]
dell.idrac.global.storage.statusGlobal Storage StatusIndicates the overall storage status being monitored by the remote access card. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.3.0]
dell.idrac.global.system.statusGlobal System StatusIndicates the overall rollup status of all components in the system being monitored by the remote access card. Includes system,storage,IO devices,iDRAC,CPU,memory,etc. Possible status values are 1- Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6-nonRecoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.1.0]
dell.idrac.system.power.statePower StateIndicates the power state of the system. Possible status values are 1: Other,2- Unknown,3- Off,4- On.[OID: 1.3.6.1.4.1.674.10892.5.2.4.0]
Dell iDRAC Temperaturedell.idrac.temperature.readingTemperature ReadingCIt represents the reading for a temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.8]
dell.idrac.temperature.statusTemperature StatusIt represents the probe status of the temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.7,1.3.6.1.4.1.674.10892.5.4.700.20.1.8]
Dell iDRAC Virtual Disk Statusdell.idrac.virtual.disk.statusVirtual Disk StatusRepresents the current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.3]
dell.idrac.virtual.disk.badblocksis Virtual Disk has Bad Blocks ?Indicates whether the virtual disk has bad blocks.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23]
Dell iDRAC Voltagedell.idrac.voltage.prob.readingVoltage Probe ReadingvMonitors the power supply voltage probe reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.20.1.6,1.3.6.1.4.1.674.10892.5.4.600.20.1.8]
dell.idrac.voltage.prob.statusVoltage Probe StatusRepresents the probe status of the voltage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.5]

Dell iDRAC Monitors - v3

Description

Additional metrics( Status,Cumulative Wattage,Peak Watts,Peak Amps) support added to existing template(Dell iDRAC Monitors - v2) for Dell iDRAC. Monitors Global storage status,global system status,LCD status and power status. Virtual Disk,Physical Disk,Memory(DIMMs),CPU,Power Supply,Power Unit,Fan,Battery,Temperature Sensor,BIOS,Voltage,Amperage,cooling system status,power supply status,processor status Tested on Dell iDRAC PowerEdge R720 and R620 devices.

Prerequisites

NULL

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell iDRAC System Statsdell.idrac.global.system.statusGlobal System StatusNoneIndicates the overall rollup status of all components in the system being monitored by the remote access card. Includes system,storage,IO devices,iDRAC,CPU,memory,etc. Possible status values are 1- Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6-nonRecoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.1.0]
Dell iDRAC System Battery Statusdell.idrac.system.battery.readingBattery ReadingIt represents the battery reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7]
Dell iDRAC Enclosure Power Suppliesdell.idrac.enclosure.powersupplies.statusEnclosures Power SuppliesMonitors the status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other,2: Unknown,3: OK,4: Non-critical,5: Critical,6: Non-recoverable.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9]
Dell iDRAC Memory(DIMMs) Statusdell.idrac.memory.statusMemory (DIMMs) StatusRepresents the status of the memory(DIMMs).[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5,1.3.6.1.4.1.674.10892.5.4.1100.50.1.8,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14]
Dell iDRAC Intrusion Statusdell.idrac.intrusion.statusIntrusion Sensor StatusThe status of the intrusion sensor.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.5,1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.7,1.3.6.1.4.1.674.10892.5.4.300.70.1.8]
Dell iDRAC Voltagedell.idrac.voltage.prob.readingVoltage Probe ReadingvMonitors the power supply voltage probe reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.20.1.6,1.3.6.1.4.1.674.10892.5.4.600.20.1.8]
Dell iDRAC Power Usage Statisticsdell_idrac_PowerUsageCumulativeWattage_WatthoursDell iDRAC Total Power Wattage used(in Watt-hours)Dell iDRAC total power wattage used(in Watt-hours).[IDRAC-MIB::powerUsageCumulativeWattage:1.3.6.1.4.1.674.10892.5.4.600.60.1.7]
Dell iDRAC Temperaturedell.idrac.temperature.readingTemperature ReadingCIt represents the reading for a temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.8]
Dell iDRAC System Battery Statusdell.idrac.system.battery.statusBattery StatusIt represents the status of the battery.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.5,1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7]
Dell iDRAC Intrusion Statusdell.idrac.intrusion.readingIntrusion Sensor ReadingIt represents the intrusion reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.8]
Dell iDRAC Amperage Reading in Wattsdell.idrac.amperage.reading.wattsAmperage Reading in WattsWRepresents the power usage that the probe is reading in Watts. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyWatts or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6]
Dell iDRAC Fan Statusdell.idrac.fan.statusFan StatusRepresents the status of the probe status of the cooling device/fan.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.12.1.2,1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8]
Dell iDRAC Physical Disk Statusdell.idrac.phydisk.statusPhysical Disk StatusThe current state of this physical disk. Possible states - 1: unknown - The current state could not be determined. 2: ready - The physical disk is available for use,but no RAID configuration has been assigned. 3: online - A RAID configuration has been assigned to the physical disk. 4: foreign - The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: offline - The physical disk is not available to the RAID controller. 6: blocked - The physical disk is currently blocked by controller. 7: failed - The physical disk is not operational. 8: non-raid - The physical disk is not a RAID capable disk 9: removed - The physical disk has been removed.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4]
Dell iDRAC Amperage Reading in Ampsdell.idrac.amperage.reading.ampsAmperage Reading in AmpsampsRepresents the power usage that the probe is reading in Amps. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6]
Dell iDRAC System Statsdell.idrac.system.lcd.statusLCD StatusNoneIndicates the system status as it is reflected by the LCD front panel. Not all system components may be included. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.2.0]
Dell iDRAC Power Usage Statisticsdell_idrac_PowerUsagePeakAmpsDell iDRAC Power Usage Peak AmpsampsMonitors the dell iDRAC power usage peak amps.[IDRAC-MIB::powerUsagePeakAmps:1.3.6.1.4.1.674.10892.5.4.600.60.1.12]
Dell iDRAC Virtual Disk Statusdell.idrac.virtual.disk.badblocksis Virtual Disk has Bad Blocks ?Indicates whether the virtual disk has bad blocks.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23]
Dell iDRAC System Statsdell.idrac.system.power.statePower StateNoneIndicates the power state of the system. Possible status values are 1: Other,2- Unknown,3- Off,4- On.[OID: 1.3.6.1.4.1.674.10892.5.2.4.0]
Dell iDRAC System Hardware Statusdell_idrac_SystemStateProcessorDeviceStatusDell iDRAC System Processor Device StatusMonitors the dell idrac processor status.[IDRAC-MIB::systemStateProcessorDeviceStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.50].Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6) .
Dell iDRAC Amperage Statusdell.idrac.amperage.probe.statusAmperage Probe StatusRepresents the probe status of the amperage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.5]
Dell iDRAC System BIOS Statusdell.idrac.system.bios.statusBIOS StatusRepresents the status of the system BIOS.[OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5]
Dell iDRAC System Hardware Statusdell_idrac_SystemStateCoolingDeviceStatusDell iDRAC System Cooling Device StatusMonitors the dell idrac cooling system status.[IDRAC-MIB::systemStateCoolingDeviceStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.21].Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6).
Dell iDRAC System Statsdell.idrac.global.storage.statusGlobal Storage StatusNoneIndicates the overall storage status being monitored by the remote access card. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.3.0]
Dell iDRAC Fan Readingdell.idrac.fan.speedFan SpeedrpmRepresents the reading for a cooling device of subtypes (coolingDeviceSubTypeIsAFanThatReadsInRPM and coolingDeviceSubTypeIsAPowerSupplyFanThatReadsinRPM) [OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.6]
Dell iDRAC Chassis Statusdell.idrac.system.chassis.statusChassis StatusRepresents the status of the system chassis.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.10.1.4,1.3.6.1.4.1.674.10892.5.4.300.10.1.7]
Dell iDRAC Power Supply Statusdell.idrac.powersupply.statusPower Supply StatusMonitors the status of the power supply.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.7,1.3.6.1.4.1.674.10892.5.4.600.12.1.8,1.3.6.1.4.1.674.10892.5.4.600.12.1.11,1.3.6.1.4.1.674.10892.5.4.600.12.1.12]
Dell iDRAC Amperage Reading in Milliampsdell.idrac.amperage.reading.milliampsAmperage Reading in MilliampsmARepresents the power usage that the probe is reading in Milliamps. It monitors only when amperageProbeType is other than amperageProbeTypeIsDiscrete,amperageProbeTypeIsPowerSupplyAmps,amperageProbeTypeIsPowerSupplyWatts,amperageProbeTypeIsSystemAmps or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6]
Dell iDRAC Voltagedell.idrac.voltage.prob.statusVoltage Probe StatusRepresents the probe status of the voltage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.5]
Dell iDRAC Temperaturedell.idrac.temperature.statusTemperature StatusIt represents the probe status of the temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.7,1.3.6.1.4.1.674.10892.5.4.700.20.1.8]
Dell iDRAC System Hardware Statusdell_idrac_SystemStatePowerUnitStatusDell iDRAC System Power Unit StatusMonitors the dell idrac power supply status.[IDRAC-MIB::systemStatePowerUnitStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.42]. Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6).
Dell iDRAC Power Usage Statisticsdell_idrac_PowerUsagePeakWattsDell iDRAC Power Usage Peak WattsWMonitors the dell iDRAC power usage peak watts.[IDRAC-MIB::powerUsagePeakWatts:1.3.6.1.4.1.674.10892.5.4.600.60.1.9]
Dell iDRAC CPU Statusdell.idrac.cpu.statusCPU StatusMonitors the status of the processor device status probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6,1.3.6.1.4.1.674.10892.5.4.1100.32.1.7,1.3.6.1.4.1.674.10892.5.4.1100.30.1.5,1.3.6.1.4.1.674.10892.5.4.1100.30.1.8]
Dell iDRAC Physical Disk Statusdell.idrac.phydisk.smart.statusPhysical Disk Smart StatusMonitors whether the physical disk has received a predictive failure alert or not. Possible values are 0(False),1(True). It generates alert if it is True.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31]
Dell iDRAC Power Usage Statisticsdell_idrac_PowerUsageStatusDell iDRAC Power Usage StatusMonitors the dell iDRAC power usage status.[IDRAC-MIB::powerUsageStatus:1.3.6.1.4.1.674.10892.5.4.600.60.1.5]
Dell iDRAC Virtual Disk Statusdell.idrac.virtual.disk.statusVirtual Disk StatusRepresents the current state of this virtual disk (which includes any member physical disks.)Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.3]

Dell iDRAC PowerEdge R440

Description

Template to monitor Global System Status,LCD Status,Global Storage Status,Power State,Virtual Disk Status,is Virtual Disk has Bad Blocks,Physical Disk Status,Physical Disk Smart Status.Validated on iDRAC v9,Firmware version 3.21.26.22,Sysobjectid : 1.3.6.1.4.1.674.10892.5

Prerequisites

The device should have support for IDRAC-MIB-SMIv2.

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell iDRAC Physical Disk Statusdell.idrac.phydisk.statusPhysical Disk StatusThe current state of this physical disk. Possible states - 1: unknown - The current state could not be determined. 2: ready - The physical disk is available for use,but no RAID configuration has been assigned. 3: online - A RAID configuration has been assigned to the physical disk. 4: foreign - The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: offline - The physical disk is not available to the RAID controller. 6: blocked - The physical disk is currently blocked by controller. 7: failed - The physical disk is not operational. 8: non-raid - The physical disk is not a RAID capable disk 9: removed - The physical disk has been removed.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4]
dell.idrac.phydisk.smart.statusPhysical Disk Smart StatusMonitors whether the physical disk has received a predictive failure alert or not. Possible values are 0(False),1(True). It generates alert if it is True.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31]
Dell iDRAC System Statsdell.idrac.global.system.statusGlobal System StatusIndicates the overall rollup status of all components in the system being monitored by the remote access card. Includes system,storage,IO devices,iDRAC,CPU,memory,etc. Possible status values are 1- Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6-nonRecoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.1.0]
dell.idrac.system.lcd.statusLCD StatusIndicates the system status as it is reflected by the LCD front panel. Not all system components may be included. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.2.0]
dell.idrac.global.storage.statusGlobal Storage StatusIndicates the overall storage status being monitored by the remote access card. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.3.0]
dell.idrac.system.power.statePower StateIndicates the power state of the system. Possible status values are 1: Other,2- Unknown,3- Off,4- On.[OID: 1.3.6.1.4.1.674.10892.5.2.4.0]
Dell iDRAC Virtual Disk Statusdell.idrac.virtual.disk.statusVirtual Disk StatusRepresents the current state of this virtual disk (which includes any member physical disks). Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.3]
dell.idrac.virtual.disk.badblocksis Virtual Disk has Bad Blocks ?Indicates whether the virtual disk has bad blocks.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23]

Dell Networking Chassis

Description

Template to monitor the CPU 5min utilization,memory utilization,power supply status,fan status,stack unit status,stack unit temperature,system uptime.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell Networking Chassis - Fan Statusdell.force10.unit.fan.statusFan StatusStatus of the Fan tray units. Possible values are 1 - Up,2 - Down,3 - Absent.[OID: 1.3.6.1.4.1.6027.3.26.1.4.7.1.4]
Dell Networking Chassis - Power Supply Statusdell.force10.unit.power.supplyPower Supply Operational StatusThe status of the power supply. Possible values are up(1),down(2),absent(3).[OIDs:1.3.6.1.4.1.6027.3.26.1.4.6.1.4,1.3.6.1.4.1.6027.3.26.1.4.6.1.5]
Dell Networking Chassis - Stack Unit Monitordell.force10.unit.temperatureUnit TemperatureCThe temperature of the stack unit.[OID: 1.3.6.1.4.1.6027.3.26.1.3.4.1.13]
dell.force10.stack.unit.statusStack Unit StatusThe current status of the unit. Possible values are 1 - OK,2 - unsupported,3 - codeMismatch,4 - ConfigMismatch,5 - unitDown,6 - notPresent.[OID: 1.3.6.1.4.1.6027.3.26.1.3.4.1.8]
Dell Performance Monitorsystem.cpu.utilizationCPU Utilization%CPU utilization in percentage for last 5 minutes.[OID:1.3.6.1.4.1.6027.3.26.1.4.4.1.5,1.3.6.1.4.1.6027.3.26.1.4.3.1.4]
system.memory.util.percentMemory Utilization%Total memory usage in percentage.[OID: 1.3.6.1.4.1.6027.3.26.1.4.4.1.6,1.3.6.1.4.1.6027.3.26.1.4.3.1.6]
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

Dell Networking Sxxxx-ON Series Switches

Description

It is applicable on Dell Networking Sxxxx-ON Series Switches. It monitors the CPU 5min utilization,Memory utilization,Fans status,Power supply status,SNMP trap service status,Global product status and Uptime. This template validated on Dell open network S3048-ON,S4048-ON,S6010-ON series switches. SysObjID: enterprises.6027.1.3.22,enterprises.6027.1.3.23,enterprises.6027.1.3.29

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell Performance Monitorsystem.cpu.utilizationCPU Utilization%CPU utilization in percentage for last 5 minutes.[OID:1.3.6.1.4.1.6027.3.26.1.4.4.1.5,1.3.6.1.4.1.6027.3.26.1.4.3.1.4]
system.memory.util.percentMemory Utilization%Total memory usage in percentage.[OID: 1.3.6.1.4.1.6027.3.26.1.4.4.1.6,1.3.6.1.4.1.6027.3.26.1.4.3.1.6]
Dell PowerConnect Fan Statesystem.fan.statusFan StatusThe mandatory state of the fan being instrumented.[OID:1.3.6.1.4.1.674.10895.3000.1.2.110.7.1.1.3]
Dell PowerConnect Power Supply Statushw.dell.powerconnect.power.supply.statusPower Supply StatusThe mandatory state of the power supply being instrumented.[OIDs: 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.3,1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.4]
Dell PowerConnect Product Global Statushw.dell.powerconnect.global.statusGlobal statusIndicates the current status of the Dell PowerConnect product. This is a rollup for the entire product. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. Possible status values are 3- OK: If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure or a SW fatal error condition. 4- Non-critical: If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure or a SW fatal error condition,5- Critical: If at least one fan is not functional,possibly causing a dangerous warming up of the device.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.1.0]
Dell PowerConnect SNMP Trap Service Statushw.dell.powerconnect.traps.flag.statusDell PowerConnect Product Status Generating Traps FlagIndicates if this SNMP service is generating SNMP Traps. This variable can take the following values:
1: true - The device is capable and currently configured to generate traps if necessary.
2: false - The device is not capable of generating traps.
3: disabled - The device is capable but not configured.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.6.0]
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

Dell PowerConnect 7000 Series Switches

Description

Monitors the basic system performance monitors like CPU,Memory and Uptime. It also monitors the hardware parameters like Fan,Temperature,Power supply and global status of the system. Tested on PowerConnect 7048,5.1.3.7,VxWorks 6.6.[SysObjId: 1.3.6.1.4.1.674.10895.3035].

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell PowerConnect CPU Utilization - DNOS (fastPathSwitching)system.cpu.utilizationCPU Utilization%Monitors the total CPU Utilization.
Dell PowerConnect Fan - DNOS (fastPathBoxServices)hw.dell.powerconnect.fan.statusFan StatusIndicates the status of fan.
hw.dell.powerconnect.fan.speedFan SpeedrpmMonitors the speed of the Fan.
Dell PowerConnect Memory Utilization - DNOS (fastPathSwitching)system.memory.util.percentMemory Utilization%Memory Utilization - Indicates the instances of the memory pool which are currently in use and which are free.[OIDs: 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.1.1.4.1.0,1.3.6.1.4.1.674.10895.5000.2.6132.1.1.1.1.4.2.0]
Dell PowerConnect Power Supply - DNOS (fastPathBoxServices)hw.dell.powerconnect.power.supply.statusPower Supply StatusMonitors the status of power supply.
Dell PowerConnect Product Global Statushw.dell.powerconnect.global.statusGlobal statusIndicates the current status of the Dell PowerConnect product. This is a rollup for the entire product. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. Possible status values are 3- OK: If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure or a SW fatal error condition. 4- Non-critical: If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure or a SW fatal error condition,5- Critical: If at least one fan is not functional,possibly causing a dangerous warming up of the device.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.1.0]
Dell PowerConnect Temperature - DNOS (fastPathBoxServices)hw.dell.powerconnect.temperature.valueTemperature ValueCRepresents the power connect temperature value reported by sensor.
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

Dell PowerConnect Ethernet Switch Template - G2

Description

Template for Dell PowerConnect Ethernet Switch. Monitors fan status,power supply status,global status,etc. Tested on PowerConnect 5448 Ethernet switch.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell PowerConnect Fan Statesystem.fan.statusFan StatusThe mandatory state of the fan being instrumented.[OID:1.3.6.1.4.1.674.10895.3000.1.2.110.7.1.1.3]
Dell PowerConnect Physical Sensor Operational Statusentity.physicalsensor.operational.statusEntity Physical Sensor Operational StatusProvides the operational status of the entity physical sensor.[OIDs: 1.3.6.1.4.1.89.83.2.1.1.1.4,1.3.6.1.4.1.89.83.2.1.1.1.5]
Dell PowerConnect Power Supply Statushw.dell.powerconnect.power.supply.statusPower Supply StatusThe mandatory state of the power supply being instrumented.[OIDs: 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.3,1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.4]
Dell PowerConnect Product Global Statushw.dell.powerconnect.global.statusGlobal statusIndicates the current status of the Dell PowerConnect product. This is a rollup for the entire product. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. Possible status values are 3- OK: If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure or a SW fatal error condition. 4- Non-critical: If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure or a SW fatal error condition,5- Critical: If at least one fan is not functional,possibly causing a dangerous warming up of the device.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.1.0]
Dell PowerConnect Radlan Fan Data Temperatureradlan.environment.fandata.temperatureRadlan Environment Fan Data TemperatureCProvides the unit temperature for Radlan environment fan data temperature.[OIDs: 1.3.6.1.4.1.89.83.2.1.1.1.1,1.3.6.1.4.1.89.83.2.1.1.1.2]
Dell PowerConnect SNMP Trap Service Statushw.dell.powerconnect.traps.flag.statusDell PowerConnect Product Status Generating Traps FlagIndicates if this SNMP service is generating SNMP Traps. This variable can take the following values: 1: true - The device is capable and currently configured to generate traps if necessary. 2: false - The device is not capable of generating traps. 3: disabled - The device is capable but not configured.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.6.0]

Dell PowerConnect M8024 Switches

Description

Monitors the basic system performance monitors like CPU,Memory and Uptime. It also monitors the hardware parameters like Temperature and Power supply status. Tested on PowerConnect M8024,5.1.4.5,VxWorks 6.6.[SysObjId: 1.3.6.1.4.1.674.10895.3022].
Note: CPU Utilization monitor work with OpsRamp Gateway v2.6.0 release and later releases only.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell PowerConnect M8024 CPU Utilizationsystem.cpu.utilizationCPU Utilization%Monitors the total CPU Utilization.
Dell PowerConnect M8024 Power Supplyhw.dell.powerconnect.power.supply.statusPower Supply StatusMonitors the status of power supply.
Dell PowerConnect M8024 Temperaturehw.dell.powerconnect.temperature.valueTemperature ValueCRepresents the power connect temperature value reported by sensor.
Dell PowerConnect Memory Utilizationsystem.memory.util.percentMemory Utilization%Memory Utilization - Indicates the instances of the memory pool which are currently in use and which are free.[OIDs: 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.1.1.4.1.0,1.3.6.1.4.1.674.10895.5000.2.6132.1.1.1.1.4.2.0]
Dell PowerConnect Product Global Statushw.dell.powerconnect.global.statusGlobal statusIndicates the current status of the Dell PowerConnect product. This is a rollup for the entire product. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. Possible status values are 3- OK: If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure or a SW fatal error condition. 4- Non-critical: If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure or a SW fatal error condition,5- Critical: If at least one fan is not functional,possibly causing a dangerous warming up of the device.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.1.0]
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

Dell Server Status - G2

Description

Default monitoring and alerting template for Dell Servers. Monitors chassis intrusion detection reading,memory status,system board fan speed,etc.,

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell Server Array Controller Statusarraycontroller.statusArray Controller StatusMonitors the status of the controller itself without the propagation of any contained component status. Possible values are 1- Other,2- Unknown,3- OK,4- Non-critical,5- Critical,6- Non-recoverable.[OIDs: 1.3.6.1.4.1.674.10893.1.20.130.1.1.2,1.3.6.1.4.1.674.10893.1.20.130.1.1.38]
arraycontroller.component.status.allArray Controller and all Components StatusMonitors the severity of the controller state. This is the combined status of the controller and its components. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10893.1.20.130.1.1.2,1.3.6.1.4.1.674.10893.1.20.130.1.1.37]
Dell Server Array Disk Component Statusdell.arraydisk.component.statusArray Disk Component StatusMonitors the status of the array disk itself without the propagation of any contained component status. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10893.1.20.130.4.1.2,1.3.6.1.4.1.674.10893.1.20.130.4.1.24]
Dell Server Baseboard Power Supply Statusdell.baseboard.powersupply.statusPower Supply StatusRepresents the status of the Dell baseboard power supply.[OID: 1.3.6.1.4.1.674.10892.1.600.12.1.5]
dell.baseboard.powersupply.sensor.statusPower Supply Sensor StatusThis attribute defines the state reported by the power supply sensor. This attribute supplements the attribute powerSupplyStateSettingsUnique.[OID: 1.3.6.1.4.1.674.10892.1.600.12.1.11,1.3.6.1.4.1.674.10892.1.600.12.1.4]
Dell Server Chassis Intrusionhw.chasis.intrusion.detection.readingChassis Intrusion Detection ReadingMonitors the the reading of the intrusion sensor. Possible values are 1- chassisNotBreached,2- chassisBreached,3- chassisBreachedPrior,4- chassisBreachSensorFailure.[OIDs: 1.3.6.1.4.1.674.10892.1.300.70.1.2.1,1.3.6.1.4.1.674.10892.1.300.70.1.6.1]
Dell Server Chassis Intrusion Sensor Statushw.chasis.intrusion.obj.statusChassis Intrusion Object StatusMonitors the status of the intrusion sensor. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10892.1.300.70.1.2,1.3.6.1.4.1.674.10892.1.300.70.1.5]
Dell Server Memory Device Statusdell.memory.device.statusMemory Device StatusMonitors the status of the memory device. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10892.1.1100.50.1.2.1,1.3.6.1.4.1.674.10892.1.1100.50.1.5.1]
Dell Server Processor Device Statusdell.processor.device.statusProcessor Device StatusMonitors the status of the processor device. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10892.1.1100.30.1.2.1,1.3.6.1.4.1.674.10892.1.1100.30.1.5.1]
dell.processor.device.status.stateProcessor Device Status StateMonitors the status state of the processor device. Possible values are 1- other,2- unknown,3- enabled,4- userDisabled,5- biosDisabled,6- idle.[OIDs: 1.3.6.1.4.1.674.10892.1.1100.30.1.2.1,1.3.6.1.4.1.674.10892.1.1100.30.1.9.1]
Dell Server System Board BIOS Statusdell.hw.bios.statusSystem Board BIOS StatusMonitors the status of the system BIOS. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10892.1.300.50.1.2,1.3.6.1.4.1.674.10892.1.300.50.1.5]
Dell Server System Board Fan Speeddell.systemboard.fan.speedSystem Board Fan SpeedrpmMonitors the system board fan speed.[OIDs: 1.3.6.1.4.1.674.10892.1.700.12.1.2.1,1.3.6.1.4.1.674.10892.1.700.12.1.6.1]
Dell Server Voltage Probe Statusdell.voltage.probe.statusVoltage Probe StatusMonitors the probe status of the voltage probe. :Possible values are 1- other,2- unknown,3- ok,4- nonCriticalUpper,5- criticalUpper,6- nonRecoverableUpper,7- nonCriticalLower,8- criticalLower,9- nonRecoverableLower,10- failed.[OIDs: 1.3.6.1.4.1.674.10892.1.600.20.1.2.1,1.3.6.1.4.1.674.10892.1.600.20.1.5.1]

Dell SonicWall NSA 240 - G2

Description

Applicable on the SonicWall NSA series firewall appliance- SonicWALL NSA 240. Sys OID- 1.3.6.1.4.1.8741.1. Monitors VPN Performance,Health,Active Connections.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Sonicwall NSA Healthsonicwall.nsa.cpu.utilizationCPU Utilization%Provides the instantaneous CPU Utilization in percent.[OID: 1.3.6.1.4.1.8741.1.3.1.3.0]
sonicwall.nsa.ram.utilizationSonicwall RAM Utilization%Provides the instantaneous RAM Utilization in percent.[OID: 1.3.6.1.4.1.8741.1.3.1.4.0]
sonicwall.nsa.active.connectionsSonicwall Active ConnectionsThe number of active connections currently being managed by the SonicWALL firewall.[OID: 1.3.6.1.4.1.8741.1.3.1.2.0]
Sonicwall VPN Performancesonicwall.vpn.encrypt.bytesEncrypted BytesBpsVPN Performance - rate of encrypted traffic flowing through the IPSec tunnel [OID: 1.3.6.1.4.1.8741.1.3.2.1.1.1.2,1.3.6.1.4.1.8741.1.3.2.1.1.1.3,1.3.6.1.4.1.8741.1.3.2.1.1.1.9]
sonicwall.vpn.decrypt.bytesDecrypted BytesBpsVPN Performance - rate of decrypted traffic flowing through the IPSec tunnel [OID: 1.3.6.1.4.1.8741.1.3.2.1.1.1.2,1.3.6.1.4.1.8741.1.3.2.1.1.1.3,1.3.6.1.4.1.8741.1.3.2.1.1.1.11]
System Uptimesystem.uptimeSystem UptimesThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]

Dell UPS

Description

Template to monitor Dell UPS global status,Load Segment parameters like Load Segment1 Shutdown After Delay,Load Segment2 Shutdown After Delay,physical battery parameters like AMB(Advanced Battery Monitoring) Status,Seconds Remaining,Test Status,Physical Output parameters like Cumulative Consumption,Instant Headroom,Peak Consumption,Peak Headroom,Present Consumption,Output VA,Physical Rectifier parameters like Negative Voltage,Positive Voltage. sysObjectID:1.3.6.1.4.1.674.10902.2

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Dell UPS - Global Statusdell.ups.global.statusGlobal StatusIt monitors the current status of the product.Possible values are 1: other,2: unknown,3: ok,4: non-critical,5: critical,6: non-recoverable.[DELL-SNMP-UPS-MIB::productStatusGlobalStatus:1.3.6.1.4.1.674.10902.2.110.1.0].
Dell UPS - Load Segmentdell.ups.physical.load.segment2.shutdown.after.delayPhysical Load Segment2 Shutdown After DelaysIt monitors the number of seconds remaining until load segment 2 will switch off. -1 if no shutdown countdown is in effect.[DELL-SNMP-UPS-MIB::physicalLoadSegment2ShutdownAfterDelay:1.3.6.1.4.1.674.10902.2.120.6.3.0].
dell.ups.physical.load.segment1.shutdown.after.delayPhysical Load Segment1 Shutdown After DelaysIt monitors the number of seconds remaining until load segment 1 will switch off. -1 if no shutdown countdown is in effect.[DELL-SNMP-UPS-MIB::physicalLoadSegment1ShutdownAfterDelay:1.3.6.1.4.1.674.10902.2.120.6.1.0].
Dell UPS - Physical Batterydell.ups.physical.battery.seconds.remainingPhysical Battery Seconds RemainingsIt monitors the battery remaining time calculated by the autonometer in seconds.[DELL-SNMP-UPS-MIB::physicalBatterySecondsRemaining:1.3.6.1.4.1.674.10902.2.120.5.3.0].
dell.ups.physical.battery.test.statusPhysical Battery Test StatusIt monitors the battery test status. Possible values are 1: donePassed,2: doneWarning,3: doneError,4: aborted,5: inProgress,6: noTestIniated,7: testScheduled.[DELL-SNMP-UPS-MIB::physicalBatteryTestStatus:1.3.6.1.4.1.674.10902.2.120.5.2.0].
dell.ups.physical.battery.amb.statusPhysical Battery AMB(Advanced Battery Monitoring) StatusIt monitors the advanced battery monitoring(AMB) status.Possible values are 1: abmCharging,2: abmDischarging,3: abmFloating,4: abmResting,5: abmOff.[DELL-SNMP-UPS-MIB::physicalBatteryABMStatus:1.3.6.1.4.1.674.10902.2.120.5.1.0].
Dell UPS - Physical Outputdell.ups.physical.output.cumulative.consumptionPhysical Output Cumulative ConsumptionIt monitors the 64 bit meter value that is derived by reading the Present KWH Consumption meter once per hour and adding it to the last value of this meter.[DELL-SNMP-UPS-MIB::physicalOutputCumulativeConsumption:1.3.6.1.4.1.674.10902.2.120.2.7.0].
dell.ups.physical.output.peak.headroomPhysical Output Peak HeadroomWIt monitors the statistical value holding the lowest value that Instantaneous Headroom Watts was ever set too since the last time this statistic was reset.[DELL-SNMP-UPS-MIB::physicalOutputPeakHeadroom:1.3.6.1.4.1.674.10902.2.120.2.2].
dell.ups.physical.output.present.consumptionPhysical Output Present ConsumptionIt monitors the watt second consumption over the past hour.[DELL-SNMP-UPS-MIB::physicalOutputPresentConsumption:1.3.6.1.4.1.674.10902.2.120.2.6.0].
dell.ups.physical.output.vaPhysical Output VA(volt-ampere)It monitors the physical output VA(volt-ampere) .[DELL-SNMP-UPS-MIB::physicalOutputVA:1.3.6.1.4.1.674.10902.2.120.2.9.0].
dell.ups.physical.output.instant.headroomPhysical Output Instant HeadroomWIt monitors the present amount of watt capacity remaining before overload.[DELL-SNMP-UPS-MIB::physicalOutputInstantHeadroom:1.3.6.1.4.1.674.10902.2.120.2.1.0].
dell.ups.physical.output.peak.consumptionPhysical Output Peak Consumption (RMS Watts)It monitors the statistical value of the maximum RMS Watts the UPS has seen since the last time this statistic was reset.[DELL-SNMP-UPS-MIB::physicalOutputPeakConsumption,1.3.6.1.4.1.674.10902.2.120.2.4.0].
Dell UPS - Physical Rectifierdell.ups.physical.rectifier.negative.voltagePhysical Rectifier Negative VoltagevIt monitors the DC bus negative voltage.[DELL-SNMP-UPS-MIB::physicalRectifierNegVoltage:1.3.6.1.4.1.674.10902.2.120.3.2.0].
dell.ups.physical.rectifier.positive.voltagePhysical Rectifier Positive VoltagevIt monitors the DC bus positive voltage.[DELL-SNMP-UPS-MIB::physicalRectifierPosVoltage:1.3.6.1.4.1.674.10902.2.120.3.1.0].