Dell ADVA Ensemble Virtual Edge - Performance
Description
Monitors the Dell ADVA Ensemble Virtual Edge Performance Statistics like CPU Load Average In 5 Minutes, Cpu Utilization and Memory Usage.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCpuLoadAverage5Min : 1.3.6.1.4.1.7950.3.11.1.2.5.1.7, advaENSCPUUtilization : 1.3.6.1.4.1.7950.3.11.1.2.9.1.10, advaENSMemoryUsage : 1.3.6.1.4.1.7950.3.11.1.2.9.1.3]
Prerequisites
Device must have support for ADVA-ENS-SYSTEM-INVENTORY-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell ADVA Ensemble Virtual Edge - CPU Load | dell_advaENS_CpuLoadAverage5Min | Dell AdvaENS CPU Load Average 5Minutes | It monitors the dell AdvaENS CPU Load Average in the last 5 minutes period.[ADVA-ENS-SYSTEM-INVENTORY-MIB -MIB :: advaENSCpuLoadAverage5Min : 1.3.6.1.4.1.7950.3.11.1.2.5.1.7] | |
Dell ADVA Ensemble Virtual Edge - File System | dell_advaENS_FileSystemUtilization | Dell AdvaENS File System Utilization | % | Monitors the dell advaENS File System Utilization.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemUse : 1.3.6.1.4.1.7950.3.11.1.2.8.1.6] |
dell_advaENS_FileSystemUsed | Dell AdvaENS File System Used | MB | Monitors the dell AdvaENS File System Used [ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemUsed : 1.3.6.1.4.1.7950.3.11.1.2.8.1.4] | |
dell_advaENS_FileSystemAvailable | Dell AdvaENS File System Available | MB | Monitors the dell AdvaENS File System Available.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemAvailable : 1.3.6.1.4.1.7950.3.11.1.2.8.1.5] | |
Dell ADVA Ensemble Virtual Edge - Memory Usage | dell_advaENS_MemoryUsage | Dell advaENS Memory Usage | % | Monitors the dell advaENS percent of Memory Usage.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSMemoryUsage : 1.3.6.1.4.1.7950.3.11.1.2.9.1.3] |
Dell ADVA Ensemble Virtual Edge - CPU Utilization | dell_advaENS_CpuUtilization | Dell AdvaENS CPU Utilization | % | Monitors the dell AdvaENS CPU Utilization.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCPUUtilization : 1.3.6.1.4.1.7950.3.11.1.2.9.1.10] |
Dell ADVA Ensemble Virtual Edge - Hardware
Description
Monitors the Dell ADVA Ensemble Virtual Edge Hardware Metrics like Current Temperature, Temperature Status, Current Voltage, Voltage Status, Current Tx Power, Tx Power Status, Current Rx Power, Rx Power Status.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.12, advaENSSFPTempStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.13, advaENSSFPVoltageCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.16, advaENSSFPVoltageStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.17, advaENSSFPTxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.24, advaENSSFPTxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.25, advaENSSFPRxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.28, advaENSSFPRxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.29]
Prerequisites
Device must have support for ADVA-ENS-SYSTEM-INVENTORY-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell ADVA Ensemble Virtual Edge - Hardware | dell_advaENS_SFPTempCurrent | Dell AdvaENS SFP Temperature Current | Celsius | Monitors the dell AdvaENS SFP Temperature Current.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.12] |
dell_advaENS_SFPTempStatus | Dell AdvaENS SFPTemperature Status | Monitors the dell AdvaENS SFP Temperature Status. Alert will be generated when SFP Temperature Status is "NOT OK".[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.13] | ||
dell_advaENS_SFPVoltageCurrent | Dell AdvaENS SFP Voltage Current | v | Monitors the dell AdvaENS SFP Voltage Current.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPVoltageCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.16] | |
dell_advaENS_SFPVoltageStatus | Dell AdvaENS SFP Voltage Status | Monitors the dell AdvaENS SFP Voltage Status. Alert will be generated when SFP Voltage Status is "NOT OK".[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPVoltageStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.17] | ||
dell_advaENS_SFPTxPowerCurrent | Dell AdvaENS SFP Tx Power Current | dBm | Monitors the dell AdvaENS SFP Tx Power Current.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.24] | |
dell_advaENS_SFPTxPowerStatus | Dell AdvaENS SFP Tx Power Status | Monitors the dell AdvaENS SFP Tx Power Status. Alert will be generated when SFP Tx Power Status is "NOT OK".[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.25] | ||
dell_advaENS_SFPRxPowerCurrent | Dell AdvaENS SFP Rx Power Current | dBm | Monitors the dell AdvaENS SFP Rx Power Current.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPRxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.28] | |
dell_advaENS_SFPRxPowerStatus | Dell AdvaENS SFP Rx Power Status | Monitors the dell AdvaENS SFP Rx Power Status. Alert will be generated when SFP Rx Power Status.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPRxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.29] |
Dell ADVA Ensemble Virtual Edge - Vnf
Description
Monitors the Dell ADVA Ensemble Virtual Edge Vnf Metrics like Operational Status, Vnf State, Memory Usage and Vnf Port Operational Status. [ADVA-ENS-VNF-MIB :: advaENSVnfStateOper : 1.3.6.1.4.1.7950.3.11.8.1.3.1.12, advaENSVnfState : 1.3.6.1.4.1.7950.3.11.8.1.3.1.3, advaENSVnfStateMemorUsage : 1.3.6.1.4.1.7950.3.11.8.1.3.1.13, advaENSVnfPortStateOper : 1.3.6.1.4.1.7950.3.11.8.1.5.1.9]
Prerequisites
Device must have support for ADVA-ENS-VNF-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell ADVA Ensemble Virtual Edge - Vnf | dell_advaENS_VnfState | Dell AdvaENS Vnf State | Monitors the dell advaENS Vnf State.Possible values are 1: shutdown, 2: running, 3: crashed, 4: failed, 5: paused, 6: unknown. [ADVA-ENS-VNF-MIB :: advaENSVnfState : 1.3.6.1.4.1.7950.3.11.8.1.3.1.3] | |
dell_advaENS_VnfStateOper | Dell AdvaENS Vnf Operational Status | Monitors the dell AdvaENS Vnf Operational Status. [ADVA-ENS-VNF-MIB :: advaENSVnfStateOper : 1.3.6.1.4.1.7950.3.11.8.1.3.1.12] | ||
dell_advaENS_VnfStateMemorUsage | Dell advaENS Vnf State Memory Usage | Monitors the dell AdvaENS Vnf percentage memory usage. [ADVA-ENS-VNF-MIB :: advaENSVnfStateMemorUsage : 1.3.6.1.4.1.7950.3.11.8.1.3.1.13] | ||
Dell ADVA Ensemble Virtual Edge - Vnf Port State | dell_advaENS_VnfPortStateOper | Dell AdvaENS Vnf Port Operational Status | Monitors the dell AdvaENS Vnf Port Operational Status. [ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSVnfPortStateOper : 1.3.6.1.4.1.7950.3.11.8.1.5.1.9] |
Dell ADVA Ensemble Virtual Edge - Sensor Ext
Description
Monitor the Dell ADVA Ensemble Virtual Edge Sensor Metrics like Temperature, Power and Fan. [ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2 ]
Prerequisites
Device must have support for ADVA-LM-SENSORS-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell ADVA Ensemble Virtual Edge - Sensor Ext | dell_advaENS_Temperature | Dell AdvaENS Temperature | Celsius | Monitors the dell AdvaENS Temperature. [ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2] |
dell_advaENS_Fan | Dell AdvaENS Fan | rpm | Monitors the dell AdvaENS Fan Status. [ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2] | |
dell_advaENS_Power | Dell AdvaENS Power | v | Monitors the dell AdvaENS Power in Volts. [ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2] |
Dell - CRC Errors
Description
Template to monitor Dell CRC errors. Delta = Previous value of f10IfInCRC is subtracted from Current value of f10IfInCRC.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell - CRC Errors - Delta | dell.crc.errors | CRC Errors | It monitors the total number of frames received that had a length (ex-cluding framing bits,but including FCS octets) of between 64 and 1518 octets,inclusive,but had a bad CRC. And this metric will provide CRC errors delta (Previous value of dellNetIfInCRC is subtracted from current dellNetIfInCRC value).[DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfInCRC - 1.3.6.1.4.1.6027.3.11.1.2.1.1.11] |
Dell Compellent SAN Monitors
Description
Applicable on Compellent SAN devices. Monitors the Hardware parameters like Battery,FAN,Power etc.. along with the Disk,enclosure,manageed server details,volume and Storage center status etc..
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell Compellent SAN - Cache and Battery Status | dell.compellent.controller.battery.status | Battery Status | Provides the controller cache battery status. Possible Values are 0-noBattery,1-normal,2-expirationPending,3-expired.[OID:1.3.6.1.4.1.16139.2.28.1.5] | |
dell.compellent.controller.cache.status | Cache Status | Provides the controller cache status. Possible Values are 1-Up,2-Down,3-Degraded [OID: 1.3.6.1.4.1.16139.2.28.1.3] | ||
DELL Compellent SAN - Controller Status | dell.compellent.controller.status | Controller Status | Provides the controller status. possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.13.1.3] | |
Dell Compellent SAN - Controller Temperature Sensor Status | dell.compellent.temperature.status | Temperature Status | ||
Dell Compellent SAN - Count Objects | dell.compellent.device.count | Device Count | Provides the Device Count.[OID: 1.3.6.1.4.1.16139.2.31.1.3] | |
dell.compellent.replay.count | Replay Count | Provides the Replay Count.[OID: 1.3.6.1.4.1.16139.2.31.1.4] | ||
dell.compellent.number.disks | Number of Disks | Provides the Number of Disks.[OID: 1.3.6.1.4.1.16139.2.31.1.5]. | ||
dell.compellent.count.servers | Count of Servers | Provides the Count of Servers.[OID: 1.3.6.1.4.1.16139.2.31.1.6]. | ||
dell.compellent.count.volumes | Count of Volumes | Provides the Count of Volumes.[OID: 1.3.6.1.4.1.16139.2.31.1.7]. | ||
DELL Compellent SAN - Disk Folder Status | dell.compellent.disk.folder.status | Disk Folder Status | Provides the Disk folder status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.25.1.3] | |
DELL Compellent SAN - Disk Status | dell.compellent.disk.status | Disk Status | Provides the Disk Status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.14.1.3] | |
dell.compellent.disk.health | Disk Health | Provides the Disk Health. Possible value is 1- True indicates that the disk is healthy. 2-False indicates that the disk not healthy.[OID: 1.3.6.1.4.1.16139.2.14.1.5] | ||
Dell Compellent SAN - Enclosure Audible Alarm Status | dell.compellent.enclosure.alarm.status | Enclosure Audible Alarm Status | Provides the Enclosure Audible Alarm Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.24.1.3]. | |
Dell Compellent SAN - Enclosure Fan Status | dell.compellent.enclosure.fan.status | Enclosure Fan Status | Provides the Enclosure Fan Status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.20.1.3] | |
Dell Compellent SAN - Enclosure Module Status | dell.compellent.enclosure.module.status | Enclosure Module Status | Provides the Enclosure I/O Module Status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.22.1.3] | |
Dell Compellent SAN - Enclosure Power Supply Status | dell.compellent.enclosure.power.status | Enclosure Power Status | Provides the enclosure power supply status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.21.1.3] | |
Dell Compellent SAN - Enclosure Status | dell.compellent.enclosure.status | Enclosure Status | Provides the Enclosure Status. Possible values are 1-up 2-down 3-degraded [OID: 1.3.6.1.4.1.16139.2.15.1.3] | |
Dell Compellent SAN - Enclosure Temperature Sensor Status | dell.compellent.enclosure.temperature.status | Enclosure Temperature Status | Provides the enclosure temperature sensor status. Possible values are 1-up 2-down 3-degraded.[OID: 1.3.6.1.4.1.16139.2.23.1.3] | |
Dell Compellent SAN - Fan Status | dell.compellent.fan.status | Fan Status | Provides the Fan Status. Possible values are 1-up 2-down 3-degraded.[OID: 1.3.6.1.4.1.16139.2.16.1.3] | |
Dell Compellent SAN - Managed Server Status | dell.compellent.managed.server.status | Managed Server Status | Provides the Managed Server Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.27.1.3]. | |
Dell Compellent SAN - Managed UPS Status | dell.compellent.monitored.ups.status | Monitored UPS Status | Provides the Monitored UPS Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.30.1.3]. | |
Dell Compellent SAN - Power Status | dell.compellent.power.status | Power Status | Provides the Power Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.17.1.3]. | |
Dell Compellent SAN - Product Global Status | dell.compellent.global.status | Global Status | Monitors the current status of the product. This is a rollup for the entire product including any monitored devices. The status is intended to give initiative to an SNMP monitor to get further data when this status is abnormal. The value here maps from the System Status icon on the SC GUI: grey->unknown,green->ok,yellow->noncritical,red->critical. Possible values are 1-other 2-unkown 3-ok 4-noncritical 5-critical 6-nonrecoverable.[OID: 1.3.6.1.4.1.16139.2.6.0] | |
Dell Compellent SAN - Storage Center Status | dell.compellent.storage.center.status | Storage Center Status | Provides the Storage Center Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.29.1.3] | |
Dell Compellent SAN - Volume Status | dell.compellent.volume.status | Volume Status | Provides the Volume Status. Possible values are 1- Up,2- Down,3- Degraded.[OID: 1.3.6.1.4.1.16139.2.26.1.3]. |
Dell Compellent Storage Center SAN
Description
Applicable on Compellent SAN devices. Monitors the Hardware parameters like Battery,FAN,Power etc.. along with the Disk,enclosure,manageed server details,volume and Storage center status etc..
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
DELL Compellent SAN - Disk Folder Storage Usage | dell.compellent.disk.folder.space.used | Disk Folder Space Used | GB | It represents the Disk Folder Storage Usage used space,in GB (1,073,741,824). Matches 'Allocated space used by volumes' on SC GUI.[OIDs: 1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.6] |
dell.compellent.disk.folder.space.utilization | Disk Folder Space Utilization | % | Represents the Disk Folder Storage Usage space utilization,in percentage. dell.compellent.disk.folder.space.utilization = ((scDiskFolderSUUsedSpace2 * 100) / scDiskFolderSUTotalSpace2).[OIDs: 1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.5,1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.6] | |
dell.compellent.disk.folder.space.free | Disk Folder Space Free | GB | Disk Folder Storage Usage free space,in GB (1,073,741,824). scDiskFolderSUFreeSpace = scDiskFolderSUTotalSpace2 - scDiskFolderSUAllocSpace - scDiskFolderSUUsedSpace2. Matches 'Unallocated disk space' on SC GUI.[OIDs: 1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.8,1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.7,1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.6,1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.5] | |
Dell Compellent Storage Center SAN - Power Status | dell_compellent_sc_san_CtlrPowerStatus | Dell Compellent SC San Power Supply Status | Provides the Power Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scCtlrPowerStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.3] | |
Dell Compellent Storage Center SAN - Volume Status | dell_compellent_sc_san_VolumeStatus | Dell Compellent SC San Volume Status | Provides the Volume Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scVolumeStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.26.1.3] | |
Dell Compellent Storage Center SAN - Cache and Battery Status | dell_compellent_sc_san_CacheBatStatus | Dell Compellent SC San Cache Battery Status | Provides the controller cache battery status. Possible Values are 0-noBattery,1-normal,2-expirationPending,3-expired.[DELL-STORAGE-SC-MIB :: scCacheBatStat : 1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.5] | |
dell_compellent_sc_san_CacheStatus | Dell Compellent SC San Cache Status | Provides the controller cache status. Possible Values are 1-Up,2-Down,3-Degraded .[DELL-STORAGE-SC-MIB :: scCacheStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.3] | ||
Dell Compellent Storage Center SAN - Controller Status | dell_compellent_sc_san_CtlrStatus | Dell Compellent SC San Controller Status | Provides the controller status. possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scCtlrStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.3] | |
Dell Compellent Storage Center SAN - Controller Temperature Sensor Status | dell_compellent_sc_san_CtlrTempStatus | Dell Compellent SC San Controller Temp Status | Provides the Temperature Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scCtlrTempStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.3] | |
Dell Compellent Storage Center SAN - Count Objects | dell_compellent_sc_san_ObjCntServers | Dell Compellent SC San Servers Count | count | Provides the Count of Servers.[DELL-STORAGE-SC-MIB :: scObjCntServers : 1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.6] |
dell_compellent_sc_san_ObjCntDevsInUse | Dell Compellent SC San Device Count | count | Provides the Device Count.[DELL-STORAGE-SC-MIB :: scObjCntDevsInUse : 1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.3] | |
dell_compellent_sc_san_ObjCntVolumes | Dell Compellent SC San Volumes Count | count | Provides the Count of Volumes.[DELL-STORAGE-SC-MIB :: scObjCntVolumes : 1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.7] | |
dell_compellent_sc_san_ObjCntReplays | Dell Compellent SC San Replay Count | count | Provides the numbers of replays count.[DELL-STORAGE-SC-MIB :: scObjCntReplays : 1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.4] | |
dell_compellent_sc_san_ObjCntDisks | Dell Compellent SC San Disks Count | count | Provides the number of disks.[DELL-STORAGE-SC-MIB :: scObjCntDisks : 1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.5] | |
Dell Compellent Storage Center SAN - Disk Folder Status | dell_compellent_sc_san_DiskFolderStatus | Dell Compellent SC San Disk Folder Status | Provides the Disk folder status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scDiskFolderStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.3] | |
Dell Compellent Storage Center SAN - Disk Status | dell_compellent_sc_san_DiskStatus | Dell Compellent SC San Disk Status | Provides the Disk Status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scDiskStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.3] | |
dell_compellent_sc_san_DiskHealthy | Dell Compellent SC San Disk Health | Provides the Disk Health. Possible value is 1- True indicates that the disk is healthy. 2-False indicates that the disk not healthy.[DELL-STORAGE-SC-MIB :: scDiskHealthy : 1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.5] | ||
Dell Compellent Storage Center SAN - Enclosure Audible Alarm Status | dell_compellent_sc_san_EnclAlarmStatus | Enclosure Audible Alarm Status | Provides the Enclosure Audible Alarm Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scEnclAlarmStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.24.1.3] | |
Dell Compellent Storage Center SAN - Enclosure Fan Status | dell_compellent_sc_san_EnclFanStatus | Dell Compellent SC San Enclosure Fan Status | Provides the Enclosure Fan Status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scEnclFanStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.20.1.3] | |
Dell Compellent Storage Center SAN - Enclosure Module Status | dell_compellent_sc_san_EnclIoModStatus | Dell Compellent SC San Enclosure Module Status | Provides the Enclosure I/O Module Status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scEnclIoModStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.22.1.3] | |
Dell Compellent Storage Center SAN - Enclosure Power Supply Status | dell_compellent_sc_san_EnclPowerStatus | Dell Compellent SC San Enclosure Power Status | Provides the enclosure power supply status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scEnclPowerStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.21.1.3] | |
Dell Compellent Storage Center SAN - Enclosure Status | dell_compellent_sc_san_EnclStatus | Dell Compellent SC San Enclosure Status | Monitors the enclosure status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scEnclStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.3] | |
Dell Compellent Storage Center SAN - Enclosure Temperature Sensor Status | dell_compellent_sc_san_EnclTempStatus | Dell Compellent SC San Enclosure Temp Status | Provides the enclosure temperature sensor status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scEnclTempStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.23.1.3] | |
Dell Compellent Storage Center SAN - Fan Status | dell_compellent_sc_san_CtlrFanStatus | Dell Compellent SC San Fan Status | Provides the Fan Status. Possible values are 1-up 2-down 3-degraded.[DELL-STORAGE-SC-MIB :: scCtlrFanStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.3,scCtlrFanCurrentRpm : 1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.5] | |
Dell Compellent Storage Center SAN - Managed Server Status | dell_compellent_sc_san_ServerStatus | Dell Compellent SC San Managed Server Status | Provides the Managed Server Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scServerStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.27.1.3] | |
Dell Compellent Storage Center SAN - Managed UPS Status | dell_compellent_sc_san_UPSStatus | Dell Compellent SC San UPS Status | Provides the Monitored UPS Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scUPSStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.30.1.3] | |
Dell Compellent Storage Center SAN - Product Global Status | dell_compellent_sc_san_ProductIDGlobalStatus | Dell Compellent SC San Global Status | Monitors the current status of the product. This is a rollup for the entire product including any monitored devices. The status is intended to give initiative to an SNMP monitor to get further data when this status is abnormal. The value here maps from the System Status icon on the SC GUI: grey->unknown,green->ok,yellow->noncritical,red->critical. Possible values are 1-other 2-unkown 3-ok 4-noncritical 5-critical 6-nonrecoverable.[DELL-STORAGE-SC-MIB :: productIDGlobalStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.6.0] | |
Dell Compellent Storage Center SAN - Storage Center Status | dell_compellent_sc_san_ScStatus | Dell Compellent SC San Storage Center Status | Provides the Storage Center Status. Possible values are 1- Up,2- Down,3- Degraded.[DELL-STORAGE-SC-MIB :: scScStatus : 1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.3] |
Dell DRAC Status - G2
Description
Applicable on Dell Power edge M1000e Rack system. Monitors the components like chassis status,fan,power,IOM,temperature etc.,
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell DRAC Hardware Status Monitors | dell.drac.temperature.sensor.status | Dell DRAC temperature Sensor Status | Temp Sensor subsystem health status. Possible values are 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.8.0] | |
dell.drac.fan.status | Dell DRAC Fan Status | Fan subsystem health status - This system has 9(8+1 redundant) Fan modules. Any single fan can fail without impacting system uptime or reliability. In the event of a fan failure,system behavior is dependent on the resultant temperatures of the system,as monitored by the Server Module iDRAC and I/O Modules. The CMC continues to interpret the airflow needs of each server and I/O module to control the fan speeds appropriately. The system will not ramp the fans to full speed in the event of a fan failure unless deemed necessary by on-board monitoring. Failure of more than one fan will not automatically result in shutting down of blade servers. This is because the blade servers have their own self-protection mechanisms to prevent them from running too hot. The result of a failure of multiple fans would depend on the configuration,ambient temperature,and workload being run. Possible values 1- Other,2 - Unknown,3 - OK,4 - Noncritical,5 - Critical,6 - Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.6.0] | ||
dell.drac.iom.module.status | Dell DRAC IOM Module Status | IOM Status - IOM subsystem status. The chassis can hold up to six I/O modules (IOMs). Possible values 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.2.0] | ||
dell.drac.cmc.status | Dell DRAC CMC Status | CMC health status -Chassis Management Controller (CMC). The system normally has 2 CMC,CMC -1 is standard and CMC-2 provides optional redundancy. Possible values 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.9.0] | ||
dell.drac.redundancy.status | Dell DRAC Redundancy Status | Status of the redundancy subsystem. Possible values 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.4.0] | ||
dell.drac.kvm.status | Dell DRAC KVM Status | Integrated Keyboard/Video/Mouse (iKVM) switch KVM subsystem health status. Possible values are 1 -Other,2 -Unknown,3 -OK,4 -Noncritical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.3.0] | ||
dell.drac.power.status | Dell DRAC Power Status | Power Subsystem Health Status - The system has 6 Power modules. If the system has this configuration then the system will provide protection against AC grid loss or power supply failures. If one power grid fails,three power supplies lose their AC source,and the three power supplies on the other grid remain powered,providing sufficient power for the system to continue running. In the N+1 configuration only power supply failures are protected,not grid failures. The likelihood of multiple power supplies failing at the same time is remote. In the N+0 configuration there is no power protection and any protection must be provided at the node or chassis level. Possible values 1- Other,2 - Unknown,3 - OK,4 - Noncritical,5 - Critical,6 - Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.5.0] | ||
dell.drac.blade.status | Dell DRAC Blade Status | Blade subsystem health status. Possible values 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.3.1.7.0] | ||
dell.global.current.status | Global Current Status | Provides the global status. This attribute defines the overall chassis status being monitored by the chassis management card.DellStatus 1- Other,2-Unknown,3- Ok,4- Non Critical,5-Critical,6- Non Recoverable. Alert is generated when the current vale not equal to OK and previous vale is equal to OK.[OID: 1.3.6.1.4.1.674.10892.2.3.1.1]. | ||
Dell DRAC Status | dell.drac.status | Dell DRAC Status | Chassis Status - defines the overall chassis status being monitored by the chassis management card. Possible values 1 -Other,2 -Unknown,3 -OK,4 -Non-critical,5 -Critical,6 -Non-recoverable [OID: 1.3.6.1.4.1.674.10892.2.2.1.0] |
Dell EMC Data Domain
Description
Template to monitor Dell EMC Data Domain (sysObjectID : 1.3.6.1.4.1.19746.3.1.34) file system space parameters like file system percent used,file system resource tier,file system space size,file system space used,compression parameters like file system reduction percent 1,file system pre compression size,file system post compression size,file system status,replication information parameters like replication file system status,replication pre compression bytes remaining,replication synced as of time,replication state,replication status,replication configuration like replication configuration enabled,system availability and system Fs availability,boost status,CIFS status,network file system status,VTL administration state,VTL process state,fan status and fan level,power module status,temperature sensor status and temperature sensor current value. (Data Domain OS 7.4.0.5-671629)
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell EMC Data Domain - Fan Status | dell_EMCdatadomain_FanStatus | Fan Status | It monitors the current status of the fan. Possible values are notfound(0),ok(1),fail(2).[DATA-DOMAIN-MIB::fanStatus:1.3.6.1.4.1.19746.1.1.3.1.1.1.6]. | |
dell_EMCdatadomain_FanLevel | Fan Current Run Level | It monitors the current run level of fan. Possible values are unknown(0),low(1),medium(2),high(3).[DATA-DOMAIN-MIB::fanLevel:1.3.6.1.4.1.19746.1.1.3.1.1.1.5]. | ||
Dell EMC Data Domain - File System Compression | dell_EMCdatadomain_FileSystemPreCompressionSize | File System Pre Compression Size | GB | It monitors the size of the file system pre compression in gigabytes.[DATA-DOMAIN-MIB::fileSystemPreCompressionSize:1.3.6.1.4.1.19746.1.3.3.1.1.5]. |
dell_EMCdatadomain_FileSystemReductionPercent1 | File System Reduction Percent | % | It monitors the file system reduction percent.[DATA-DOMAIN-MIB::fileSystemReductionPercent1:1.3.6.1.4.1.19746.1.3.3.1.1.11]. | |
dell_EMCdatadomain_FileSystemPostCompressionSize | File System Post Compression Size | GB | It monitors the size of the file system post compression in gigabytes.[DATA-DOMAIN-MIB::fileSystemPostCompressionSize:1.3.6.1.4.1.19746.1.3.3.1.1.6]. | |
Dell EMC Data Domain - File System Space | dell_EMCdatadomain_FileSystemResourceTier | File System Resource Tier | It monitors the tier that a resource belongs to,such as active or archive.[DATA-DOMAIN-MIB::fileSystemResourceTier:1.3.6.1.4.1.19746.1.3.2.1.1.9]. | |
dell_EMCdatadomain_FileSystemSpaceSize | File System Space Size | GB | It monitors the size of the file system resource in gigabytes.[DATA-DOMAIN-MIB::fileSystemSpaceSize:1.3.6.1.4.1.19746.1.3.2.1.1.4]. | |
dell_EMCdatadomain_FileSystemPercentUsed | File System Percent Used | % | It monitors the percentage of used space within the file system resource.[DATA-DOMAIN-MIB::fileSystemPercentUsed:1.3.6.1.4.1.19746.1.3.2.1.1.7]. | |
dell_EMCdatadomain_FileSystemSpaceUsed | File System Space Used | GB | It monitors the amount of used space within the file system resource in gigabytes.[DATA-DOMAIN-MIB::fileSystemSpaceUsed:1.3.6.1.4.1.19746.1.3.2.1.1.5]. | |
Dell EMC Data Domain - File System Status | dell_EMCdatadomain_FileSystemStatus | File System Status | It monitors the status of the file system. Possible values are enabled(1),disabled(2),running(3),unknown(4),error(5),cleaning(6),starting(7).[DATA-DOMAIN-MIB::fileSystemStatus:1.3.6.1.4.1.19746.1.3.1.1.0]. | |
Dell EMC Data Domain - Power Module Status | dell_EMCdatadomain_PowerModuleStatus | Power Module Status | It monitors the current enclosure power module status. Possible values are absent(0),ok(1),failed(2),faulty(3),acnone(4),unknown(99).[DATA-DOMAIN-MIB::powerModuleStatus:1.3.6.1.4.1.19746.1.1.1.1.1.1.4]. | |
Dell EMC Data Domain - Replication Configuration | dell_EMCdatadomain_ReplicationConfigurationEnabled | Replication Configuration Enabled | It monitors the replication configuration enabled. Possible values are no(0),yes(1).[DATA-DOMAIN-MIB::replConfigEnabled:1.3.6.1.4.1.19746.1.8.2.1.1.8,replConfigDest:1.3.6.1.4.1.19746.1.8.2.1.1.4,replConfigSource:1.3.6.1.4.1.19746.1.8.2.1.1.3]. | |
Dell EMC Data Domain - Replication Information-V2 | dell_EMCdatadomain_ReplicationStatus | Replication Status | It monitors the status of replication source/dest pair connection. Possible values are connected(1),disconnected(2),migrating(3),suspended(4),neverConnected(5),idle(6).[DATA-DOMAIN-MIB::replStatus:1.3.6.1.4.1.19746.1.8.1.1.1.4,replDestination:1.3.6.1.4.1.19746.1.8.1.1.1.8,replSource:1.3.6.1.4.1.19746.1.8.1.1.1.7]. | |
dell_EMCdatadomain_ReplicationSyncedTime | Replication Synced Time | ms | It monitors the time when the source and destination were in sync,or 0 if the time is unknown.[DATA-DOMAIN-MIB::replSyncedAsOfTime:1.3.6.1.4.1.19746.1.8.1.1.1.14,replDestination:1.3.6.1.4.1.19746.1.8.1.1.1.8,replSource:1.3.6.1.4.1.19746.1.8.1.1.1.7]. | |
dell_EMCdatadomain_ReplicationState | Replication State | It monitors the state of replication source/dest pair. Possible values are initializing(1),normal(2),recovering(3),uninitialized(4).[DATA-DOMAIN-MIB::replState:1.3.6.1.4.1.19746.1.8.1.1.1.3,replDestination:1.3.6.1.4.1.19746.1.8.1.1.1.8,replSource:1.3.6.1.4.1.19746.1.8.1.1.1.7]. | ||
dell_EMCdatadomain_ReplicationPreCompressionBytesRemaining | Replication Pre Compression Bytes Remaining | Bytes | It monitors the pre compression bytes remaining.[DATA-DOMAIN-MIB::replPreCompBytesRemaining:1.3.6.1.4.1.19746.1.8.1.1.1.11,replDestination:1.3.6.1.4.1.19746.1.8.1.1.1.8,replSource:1.3.6.1.4.1.19746.1.8.1.1.1.7]. | |
dell_EMCdatadomain_ReplicationFileSystemStatus | Replication File System Status | It monitors the status of filesystem. Possible values are enabled(1),disabled(2),running(3),unknown(4),error(5),cleaning(6),starting(7).[DATA-DOMAIN-MIB::replFileSysStatus:1.3.6.1.4.1.19746.1.8.1.1.1.5,replDestination:1.3.6.1.4.1.19746.1.8.1.1.1.8,replSource:1.3.6.1.4.1.19746.1.8.1.1.1.7]. | ||
Dell EMC Data Domain - Status | dell_EMCdatadomain_VTLprocessState | VTL Process State | It monitors the state of VTL process. Possible values are unknown(0),stopped(1),starting(2),running(3),timingout(4),stopping(5),stuck(6).[DATA-DOMAIN-MIB::vtlProcessState:1.3.6.1.4.1.19746.1.11.1.2.0]. | |
dell_EMCdatadomain_CIFSstatus | CIFS Status | It monitors the CIFS status. Possible values are enabled(1),enabledRunning(2),enabledNotRunning(3),enabledWindbindNotRun(4),disabled(5).[DATA-DOMAIN-MIB::cifsStatus:1.3.6.1.4.1.19746.1.10.1.1.0]. | ||
dell_EMCdatadomain_DataDomainBoostStatus | Data Domain Boost Status | It monitors the status of the Data Domain Boost interface group on a Data Domain system. Possible values are enabled(1),disabled(2).[DATA-DOMAIN-MIB::ddboostStatus:1.3.6.1.4.1.19746.1.12.1.1.0]. | ||
dell_EMCdatadomain_VTLadministrationState | VTL Administration State | It monitors the state of VTL administration. Possible values are unknown(0),enabled(1),disabled(2),failed(3).[DATA-DOMAIN-MIB::vtlAdminState:1.3.6.1.4.1.19746.1.11.1.1.0]. | ||
dell_EMCdatadomain_NetworkFileSystemStatus | Network File System Status | It monitors the status of the network file system. Possible values are enabled(1),disabled(2).[DATA-DOMAIN-MIB::nfsStatus:1.3.6.1.4.1.19746.1.9.1.1.0]. | ||
Dell EMC Data Domain - System Availability | dell_EMCdatadomain_SystemFsAvailability | System Fs Availability | % | It monitors the system Fs availability.[DATA-DOMAIN-MIB::systemFsAvailability:1.3.6.1.4.1.19746.1.13.1.10.0]. |
dell_EMCdatadomain_SystemAvailability | System Availability | % | It monitors the system availability.[DATA-DOMAIN-MIB::systemAvailability:1.3.6.1.4.1.19746.1.13.1.8.0]. | |
Dell EMC Data Domain -Temperature Sensor Status | dell_EMCdatadomain_TemperatureSensorStatus | Temperature Sensor Status | It monitors the current status of the sensor. Possible values are failed(0),ok(1),notfound(2),overheatWarning(3),overheatCritical(4).[DATA-DOMAIN-MIB::tempSensorStatus:1.3.6.1.4.1.19746.1.1.2.1.1.1.6]. | |
dell_EMCdatadomain_TemperatureSensorCurrentValue | Temperature Sensor Current Value | Celsius | It monitors the current Temperature Value of the sensor.[DATA-DOMAIN-MIB::tempSensorCurrentValue:1.3.6.1.4.1.19746.1.1.2.1.1.1.5]. |
Dell Emc Power Switch Os10 - Hardware
Description
Templates to monitor Dell Emc power switch Os10 hardware parameters like Chassis Temparature,Card Operational Status,Card Temparature,Power Supply Operational Status,Fan Tray Operational Status,Fan Operational Status.[DELLEMC-OS10-CHASSIS-MIB :: os10ChassisTemp : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11,os10CardStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.4,os10CardTemp : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.5,os10PowerSupplyOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4,os10FanTrayOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.4,os10FanOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell Emc Power Switch Os10 - Card | dell_emc_powerswitch_Os10CardTemp | Dell Emc Power Switch Os10 Card Temparature | C | Monitors the temperature of the card in degrees Centigrade [DELLEMC-OS10-CHASSIS-MIB :: os10CardTemp : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.5] |
dell_emc_powerswitch_Os10CardStatus | Dell Emc Power Switch Os10 Card Operational Status | Monitors the current operational state of the card. Possible values are ready(1),cardMisMatch(2),cardProblem(3),diagMode(4),cardAbsent(5),offline(6).[DELLEMC-OS10-CHASSIS-MIB :: os10CardStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.4] | ||
Dell Emc Power Switch Os10 - Chassis Temperature | dell_emc_powerswitch_Os10ChassisTemp | Dell Emc Power Switch Os10 Chassis Temperature | C | Monitors the temperature of the chassis [DELLEMC-OS10-CHASSIS-MIB :: os10ChassisTemp : 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11] |
Dell Emc Power Switch Os10 - Fan Status | dell_emc_powerswitch_os10FanOperStatus | Dell Emc Power Switch Os10 Fan Operational Status | Monitors the status of the fan.Possible values are up(1),down(2),testing(3),unknown(4),dormant(5),notPresent(6),lowerLayerDown(7),failed(8).[DELLEMC-OS10-CHASSIS-MIB :: os10FanOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7] | |
Dell Emc Power Switch Os10 - Fan Tray Status | dell_emc_powerswitch_Os10FanTrayOperStatus | Dell Emc Power Switch Os10 Fan Tray Operational Status | Monitors the status of the fan tray. Possible values are Possible values are up(1),down(2),testing(3),unknown(4),dormant(5),notPresent(6),lowerLayerDown(7),failed(8).[DELLEMC-OS10-CHASSIS-MIB :: os10FanTrayOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.4] | |
Dell Emc Power Switch Os10 - Power Supply Status | dell_emc_powerswitch_Os10PowerSupplyOperStatus | Dell Emc Power Switch Power Supply Os10 Operational Status | Monitors the status of the power supply. Possible values are Possible values are up(1),down(2),testing(3),unknown(4),dormant(5),notPresent(6),lowerLayerDown(7),failed(8).[DELLEMC-OS10-CHASSIS-MIB :: os10PowerSupplyOperStatus : 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4] |
DELL Equallogic Monitors - G2
Description
Applicable on EqualLogic SAN devices. Monitors the disk Status,disk performance,Controller Battery Status,Volume status,Group and Member performance and storage etc.,
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell EqualLogic Controller Battery | controller.battery.status | Controller Battery Status | Monitors the controller battery status. Possible values are 1- ok,2- failed,3- good-battery-is-charging,4- low-voltage-status,5- low-voltage-is-charging,6- missing-battery.[OID: 1.3.6.1.4.1.12740.4.1.1.1.5] | |
controller.nvrambattery.status | Controller NVRAM Battery Status | Monitors the status of NVRAM Battery on CM. Possible values are 0- not-present,1- good,2- bad,3- unknown.[OID: 1.3.6.1.4.1.12740.4.1.1.1.32] | ||
Dell EqualLogic Disk Monitors | system.disk.busy.time | Disk Busy Time | s | Monitors the disk time in seconds spent busy.[OIDs: 1.3.6.1.4.1.12740.3.1.2.1.4,1.3.6.1.4.1.12740.3.1.1.1.10,1.3.6.1.4.1.12740.3.1.1.1.11] |
system.disk.io.operations.current | Disk IO Operations Current | Monitors the number of IO operations currently outstanding.[OID: 1.3.6.1.4.1.12740.3.1.2.1.5] | ||
system.disk.transfers.failed | Disk Transfers Failed | Monitors the number of failed transfers.[OID: 1.3.6.1.4.1.12740.3.1.2.1.6] | ||
system.disk.status | Disk Status | Monitors the equallogic disk status. Possible status values are 1- on-line: the disk is being used in the raid set,2- spare: disk is not currently being used by raid configuration but may be used when status of a currently on-line disk changes,3- failed: either disk is faulted or when there is no power,4- off-line: disk doesn't fall into any of these other categories,5- alt-sig: disk belongs to a RAIDset from another EqualLogic system. The disk can be converted to a spare,6- too-small: drive is too small to be used. The drive cannot be converted to spare,7- history-of-failures: drive has a history of failures. The drive can be converted to spare,8- unsupported-version: drive label is from a later release. The drive can be converted to spare,9- unhealthy: drive is unhealthy,10- replacement: drive is a replacement drive,11- encrypted: drive is encrypted and cannot be decrypted,12- notApproved: drive is not DELL approved,13- preempt-failed: drive is off-line due to excessive errors.[OID: 1.3.6.1.4.1.12740.3.1.1.1.8] | ||
Dell Equallogic Group Monitors | equallogic.group.storagepool.free.percent | Storage Pool Free Space Percent | % | Monitors the free space percent of the Storage Pool.[OIDs: 1.3.6.1.4.1.12740.1.1.1.1.19,1.3.6.1.4.1.12740.1.1.1.1.20,1.3.6.1.4.1.12740.1.1.2.1.1,1.3.6.1.4.1.12740.1.1.2.1.2,1.3.6.1.4.1.12740.1.1.2.1.4,1.3.6.1.4.1.12740.1.1.2.1.15] |
equallogic.group.members.online | Online Members | Monitors the number of group members which are online.[OID: 1.3.6.1.4.1.12740.1.1.2.1.3] | ||
equallogic.group.members.total | Total Members | Monitors the total number of members in this group irrelevant of current member state.[OID: 1.3.6.1.4.1.12740.1.1.2.1.13] | ||
equallogic.group.members.inuse | Members In Use | Monitors the total number of online+offline members in this group.[OID: 1.3.6.1.4.1.12740.1.1.2.1.14] | ||
DELL EqualLogic Member Fan | equallogic.member.fan | Member Fan Status | Monitors the state of the fan. Possible values are 0- unknown,1- normal,2- warning,3- critical.[OIDs: 1.3.6.1.4.1.12740.2.1.7.1.2,1.3.6.1.4.1.12740.2.1.7.1.3,1.3.6.1.4.1.12740.2.1.7.1.4] | |
DELL EqualLogic Member Monitors | equallogic.member.storage.utilization | Member Storage Utilization | % | Monitors the equallogic member storage utilization.[OIDs: 1.3.6.1.4.1.12740.2.1.1.1.9,1.3.6.1.4.1.12740.2.1.10.1.1,1.3.6.1.4.1.12740.2.1.10.1.2,1.3.6.1.4.1.12740.2.1.10.1.3,1.3.6.1.4.1.12740.2.1.10.1.4] |
equallogic.member.storage.total | Member Storage Total | MB | Monitors the total disk storage in MBs on the array.[OID: 1.3.6.1.4.1.12740.2.1.10.1.1] | |
equallogic.member.storage.used | Member Storage Used | MB | Monitors the storage used ie.,sum of reserved delegated space,reserved volume space,used snapshot space,used replication space.[OID: 1.3.6.1.4.1.12740.2.1.10.1.2] | |
equallogic.member.raid.status | Member Raid Status | Monitors the status of the raid subsystem. This is a composite of the view of the underlying subsystems. Possible values are 1- ok,2- degraded: in a degraded state,possible because no spare is available,3- verifying: a verify pass is run,and a percent complete is available,4- reconstructing: reconstructing a drive and a percent complete is available,5- a failure while we were up,possibly a drive failed and we have no spare,6- catastrophicLoss: may not be visible to the user since the member may not be able to bootup. It means we need administrator intervention to correct the problem,7- expanding,8- mirroring: mirroring a bad drive onto a spare drive.[OID: 1.3.6.1.4.1.12740.2.1.13.1.1] | ||
equallogic.member.read.latency | Member Read Latency | ms | Monitors the average latency for read operations on this member in milli seconds. The value is reset to zero upon reboot.[OID: 1.3.6.1.4.1.12740.2.1.12.1.4] | |
equallogic.member.write.latency | Member Write Latency | ms | Monitors the average latency for write operations on this member in milli seconds. The value is reset to zero upon reboot.[OID: 1.3.6.1.4.1.12740.2.1.12.1.5] | |
equallogic.member.iscsi.connections | Member iSCSI Connections | Monitors the number of iSCSI connections made from initiators to this array.[OID: 1.3.6.1.4.1.12740.2.1.12.1.1] | ||
equallogic.member.health | Member Health | Monitors the equallogic member health. Possible values are 0 - Unknown,1 - Normal,2 - Warning,3 - Critical.[OID: 1.3.6.1.4.1.12740.2.1.5.1.1] | ||
DELL EqualLogic Member Power Supply | equallogic.member.power | Member Power Supply Status | Monitors the state of the power supply. Possible values are 1- on-and-operating,2- no-ac-power,3- failed-or-no-data.[OIDs: 1.3.6.1.4.1.12740.2.1.8.1.2,1.3.6.1.4.1.12740.2.1.8.1.3,1.3.6.1.4.1.12740.2.1.8.1.4] | |
DELL EqualLogic Member Temperature | equallogic.member.temperature | Member Temperature | C | Monitors the temperature in degrees C.[OID: 1.3.6.1.4.1.12740.2.1.6.1.3,1.3.6.1.4.1.12740.2.1.6.1.2] |
equallogic.member.temperature.status | Member Temperature Status | Monitors the state of the temperature sensor. Possible values are 0- unknown,1- normal,2- warning,3- critical.[OID: 1.3.6.1.4.1.12740.2.1.6.1.4] | ||
DELL EqualLogic Storage Pool | equallogic.replication.storagespace.used | Storage Replication Space Utilization | % | Monitors the percentage of space is currently utilized by replication in this storage pool.[OIDs: 1.3.6.1.4.1.12740.16.1.1.1.3,1.3.6.1.4.1.12740.16.1.2.1.4,1.3.6.1.4.1.12740.16.1.2.1.5,1.3.6.1.4.1.12740.16.1.2.1.6] |
equallogic.storagespace.used | Storage Pool Space Utilization | % | Monitors the percentage of the space used by volumes in this pool.[OIDs: 1.3.6.1.4.1.12740.16.1.1.1.3,1.3.6.1.4.1.12740.16.1.2.1.1,1.3.6.1.4.1.12740.16.1.2.1.2,1.3.6.1.4.1.12740.16.1.2.1.3] | |
equallogic.storagespace.free | Storage Pool Space Free Percent | % | Monitors the percentage of space is available in this storage pool.[OIDs: 1.3.6.1.4.1.12740.16.1.1.1.3,1.3.6.1.4.1.12740.16.1.2.1.1,1.3.6.1.4.1.12740.16.1.2.1.2,1.3.6.1.4.1.12740.16.1.2.1.3] | |
Dell EqualLogic Volume Replication Status | volume.replication.status | Volume Replication Status | Monitors the the current operational status of the replication process. Possible status values are 1- Disabled,2- In Progress,3- Waiting,4- Far End Down,5- Auth Failure,6- Completed,7- Paused,8- Remote Resize Failed,9- Remote Paused,10- Partner Paused Local,11- Failed,12- Remote ReplReserveLow,13- Nomoresnapallowed,14- Remote Repl Reserve Invalid,15- Cancelling,16- Pending Data Transfer,17- Manual Data Transfer InProgress,18- Remote Disallow DowngradesNotSet,19- Remote Partner Needs Upgrade.[OIDs: 1.3.6.1.4.1.12740.5.1.7.15.1.3,1.3.6.1.4.1.12740.5.1.7.15.1.2,1.3.6.1.4.1.12740.5.1.7.16.1.1] | |
DELL EqualLogic Volume Status | system.volume.status | Volume Status | Monitors the current operational status of the volume.[OIDs: 1.3.6.1.4.1.12740.5.1.7.7.1.8,1.3.6.1.4.1.12740.5.1.7.1.1.8,1.3.6.1.4.1.12740.5.1.7.1.1.4] |
Dell Force10 Chassis
Description
Template to monitor Dell Force10 products which have support for F10-CHASSIS-MIB. Validated on Dell Force10 OS Operating System Version: 1.0 Application Software Version: 8.4.1.6 Series: E1200i . SysObjId=1.3.6.1.4.1.6027.1.1.5
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell Force10 Chassis - Fan Tray Status | dell.force10.chassis.fan.tray.status | Fan Tray Status | It monitors the status of the fan tray. Possible values are up(1),down(2).[F10-CHASSIS-MIB::chSysFanTrayOperStatus : 1.3.6.1.4.1.6027.3.1.1.2.2.1.2]. | |
Dell Force10 Chassis - Power Supply Status | dell.force10.chassis.power.supply.status | Power Supply Status | It monitors the status of the power supply .Possible values are up(1),down(2).[F10-CHASSIS-MIB::chSysPowerSupplyOperStatus : 1.3.6.1.4.1.6027.3.1.1.2.1.1.2]. | |
Dell Force10 Chassis - RPM Performance | dell.force10.chassis.rpm.mem.usage | RPM Memory Usage | % | It monitors the total RPM's memory usage in percentage.[F10-CHASSIS-MIB::chRpmMemUsageUtil : 1.3.6.1.4.1.6027.3.1.1.3.7.1.6]. |
dell.force10.chassis.rpm.cpu.usage.5min | RPM CPU Usage 5Min | % | It monitors the CPU utilization of RPM in percentage for last 5 minutes.[F10-CHASSIS-MIB::chRpmCpuUtil5Min : 1.3.6.1.4.1.6027.3.1.1.3.7.1.5]. | |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Dell - Force10 M Series Monitors
Description
Applicable on Dell Force 10 M series devices. Monitors CPU and memory utilization on the stack units and also it monitors environmental parameters such as power,temperature and fan. Tested on m-MXL (SysObjID: 1.3.6.1.4.1.6027.1.4.1)
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell Force10 Stack Unit Fan Status - M Series | dell.force10.unit.fan.status | Unit fan status | Status of the Fan tray units. Possible values are 1 - Up,2 - Down | |
Dell Force10 Stack Unit Monitors - M Series | dell.force10.stack.unit.status | Stack Unit Status | The current status of the unit. Possible values are 1 - OK,2 - Unsupported,3 - Code mistmatch,4 - Config mismatch,5 - Unit down,6 - Not present. | |
dell.force10.unit.temperature | Unit temperature | C | The temperature of the stack unit. | |
Dell Force10 Stack Unit Performance Monitor - M Series | system.cpu.utilization | CPU Utilization | % | CPU utilization in percentage for last 5 minutes. |
system.memory.util.percent | Memory Utilization | % | Total memory usage in percentage.[OID: 1.3.6.1.4.1.6027.3.19.1.2.8.1.5] | |
Dell Force10 Stack Unit Power Supply - M Series | dell.force10.unit.power.supply | Unit power supply | Power supply status of the unit. Possible values are 1 - normal,2 - warning,3 - critical,4 - shutdown,5 - notPresent,6 - notFunctioning. | |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Dell - Force10 S Series Monitors
Description
Applicable on Dell Force 10 switch S series. Monitors environmental parameters such as power,temperature and fan. Also checks CPU and memory utilization on the stack units. Tested on S55 switch.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell Force10 Stack Unit Fan Status - S series | dell.force10.unit.fan.status | Unit fan status | Status of the Fan tray units. Possible values are 1 - Up,2 - Down [OID: 1.3.6.1.4.1.6027.3.10.1.2.4.1.2] | |
Dell Force10 Stack Unit Monitors - S Series | dell.force10.stack.unit.status | Stack Unit Status | The current status of the unit. Possible values are 1 - OK,2 - Unsupported,3 - Code mistmatch,4 - Config mismatch,5 - Unit down,6 - Not present [OID: 1.3.6.1.4.1.6027.3.10.1.2.2.1.8,1.3.6.1.4.1.6027.3.10.1.2.2.1.2] | |
dell.force10.unit.temperature | Unit temperature | C | The temperature of the stack unit [OID: 1.3.6.1.4.1.6027.3.10.1.2.2.1.2,1.3.6.1.4.1.6027.3.10.1.2.2.1.14] | |
Dell Force10 Stack Unit Performance Monitor - S Series | system.cpu.utilization | CPU Utilization | % | CPU utilization in percentage for last 5 minutes.[OID: 1.3.6.1.4.1.6027.3.10.1.2.9.1.1,1.3.6.1.4.1.6027.3.10.1.2.9.1.4] |
system.memory.util.percent | Memory Utilization | % | Total memory usage in percentage.[OID: 1.3.6.1.4.1.6027.3.10.1.2.9.1.5,1.3.6.1.4.1.6027.3.10.1.2.7.1.4,1.3.6.1.4.1.6027.3.10.1.2.7.1.3] | |
Dell Force10 Stack Unit Power Supply - S Series | dell.force10.unit.power.supply | Unit power supply | Power supply status of the unit. Possible values are 1 - Up,2 - Down [OID: 1.3.6.1.4.1.6027.3.10.1.2.3.1.2,1.3.6.1.4.1.6027.3.10.1.2.3.1.3] | |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Dell Force10 System Uptime
Description
Monitors the elapsed time(seconds) from the Chassis Bootup Time. i.e System uptime. It is supported by VG v2.7.0 and above.[OID: 1.3.6.1.4.1.6027.3.6.1.1.1.0]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell Force10 System Uptime | dell.force10.system.uptime | UPTIME | s | Monitors the elapsed time(seconds) from the Chassis Bootup Time. i.e System uptime.[OID: 1.3.6.1.4.1.6027.3.6.1.1.1.0] |
Dell iDRAC Monitors
Description
Template for Dell iDRAC. Monitors Global storage status,global system status,LCD status and power status. Virtual Disk,Physical Disk,Memory(DIMMs),CPU,Power Supply,Power Unit,Fan,Battery,Temperature Sensor,BIOS,Voltage,Amperage etc. Tested on Dell iDRAC PowerEdge R620 device.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell iDRAC Amperage Reading in Amps | dell.idrac.amperage.reading.amps | Amperage Reading in Amps | amps | Represents the power usage that the probe is reading in Amps. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6] |
Dell iDRAC Amperage Reading in Milliamps | dell.idrac.amperage.reading.milliamps | Amperage Reading in Milliamps | mA | Represents the power usage that the probe is reading in Milliamps. It monitors only when amperageProbeType is other than amperageProbeTypeIsDiscrete,amperageProbeTypeIsPowerSupplyAmps,amperageProbeTypeIsPowerSupplyWatts,amperageProbeTypeIsSystemAmps or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6] |
Dell iDRAC Amperage Reading in Watts | dell.idrac.amperage.reading.watts | Amperage Reading in Watts | W | Represents the power usage that the probe is reading in Watts. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyWatts or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6] |
Dell iDRAC Amperage Status | dell.idrac.amperage.probe.status | Amperage Probe Status | Represents the probe status of the amperage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.5] | |
Dell iDRAC Chassis Status | dell.idrac.system.chassis.status | Chassis Status | Represents the status of the system chassis.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.10.1.4,1.3.6.1.4.1.674.10892.5.4.300.10.1.7] | |
Dell iDRAC CPU Status | dell.idrac.cpu.status | CPU Status | Monitors the status of the processor device status probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6,1.3.6.1.4.1.674.10892.5.4.1100.32.1.7,1.3.6.1.4.1.674.10892.5.4.1100.30.1.5,1.3.6.1.4.1.674.10892.5.4.1100.30.1.8] | |
Dell iDRAC Enclosure Power Supplies | dell.idrac.enclosure.powersupplies.status | Enclosures Power Supplies | Monitors the status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other,2: Unknown,3: OK,4: Non-critical,5: Critical,6: Non-recoverable.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9] | |
Dell iDRAC Fan Reading | dell.idrac.fan.speed | Fan Speed | rpm | Represents the reading for a cooling device of subtypes (coolingDeviceSubTypeIsAFanThatReadsInRPM and coolingDeviceSubTypeIsAPowerSupplyFanThatReadsinRPM) [OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.6] |
Dell iDRAC Fan Status | dell.idrac.fan.status | Fan Status | Represents the status of the probe status of the cooling device/fan.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.12.1.2,1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8] | |
Dell iDRAC Intrusion Status | dell.idrac.intrusion.reading | Intrusion Sensor Reading | It represents the intrusion reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.8] | |
dell.idrac.intrusion.status | Intrusion Sensor Status | The status of the intrusion sensor.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.5,1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.7,1.3.6.1.4.1.674.10892.5.4.300.70.1.8] | ||
Dell iDRAC Memory(DIMMs) Status | dell.idrac.memory.status | Memory (DIMMs) Status | Represents the status of the memory(DIMMs).[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5,1.3.6.1.4.1.674.10892.5.4.1100.50.1.8,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14] | |
Dell iDRAC Physical Disk Status | dell.idrac.phydisk.status | Physical Disk Status | The current state of this physical disk. Possible states - 1: unknown - The current state could not be determined. 2: ready - The physical disk is available for use,but no RAID configuration has been assigned. 3: online - A RAID configuration has been assigned to the physical disk. 4: foreign - The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: offline - The physical disk is not available to the RAID controller. 6: blocked - The physical disk is currently blocked by controller. 7: failed - The physical disk is not operational. 8: non-raid - The physical disk is not a RAID capable disk 9: removed - The physical disk has been removed.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4] | |
dell.idrac.phydisk.smart.status | Physical Disk Smart Status | Monitors whether the physical disk has received a predictive failure alert or not. Possible values are 0(False),1(True). It generates alert if it is True.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31] | ||
Dell iDRAC Power Supply Status | dell.idrac.powersupply.status | Power Supply Status | Monitors the status of the power supply.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.7,1.3.6.1.4.1.674.10892.5.4.600.12.1.8,1.3.6.1.4.1.674.10892.5.4.600.12.1.11,1.3.6.1.4.1.674.10892.5.4.600.12.1.12] | |
Dell iDRAC System Battery Status | dell.idrac.system.battery.reading | Battery Reading | It represents the battery reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7] | |
dell.idrac.system.battery.status | Battery Status | It represents the status of the battery.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.5,1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7] | ||
Dell iDRAC System BIOS Status | dell.idrac.system.bios.status | BIOS Status | Represents the status of the system BIOS.[OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5] | |
Dell iDRAC System Stats | dell.idrac.global.system.status | Global System Status | Indicates the overall rollup status of all components in the system being monitored by the remote access card. Includes system,storage,IO devices,iDRAC,CPU,memory,etc. Possible status values are 1- Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6-nonRecoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.1.0] | |
dell.idrac.system.lcd.status | LCD Status | Indicates the system status as it is reflected by the LCD front panel. Not all system components may be included. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.2.0] | ||
dell.idrac.global.storage.status | Global Storage Status | Indicates the overall storage status being monitored by the remote access card. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.3.0] | ||
dell.idrac.system.power.state | Power State | Indicates the power state of the system. Possible status values are 1: Other,2- Unknown,3- Off,4- On.[OID: 1.3.6.1.4.1.674.10892.5.2.4.0] | ||
Dell iDRAC Temperature | dell.idrac.temperature.reading | Temperature Reading | C | It represents the reading for a temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.8] |
dell.idrac.temperature.status | Temperature Status | It represents the probe status of the temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.7,1.3.6.1.4.1.674.10892.5.4.700.20.1.8] | ||
Dell iDRAC Virtual Disk Status | dell.idrac.virtual.disk.status | Virtual Disk Status | Represents the current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.3] | |
dell.idrac.virtual.disk.badblocks | is Virtual Disk has Bad Blocks ? | Indicates whether the virtual disk has bad blocks.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23] | ||
Dell iDRAC Voltage | dell.idrac.voltage.prob.reading | Voltage Probe Reading | v | Monitors the power supply voltage probe reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.20.1.6,1.3.6.1.4.1.674.10892.5.4.600.20.1.8] |
dell.idrac.voltage.prob.status | Voltage Probe Status | Represents the probe status of the voltage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.5] |
Dell iDRAC Monitors - v2
Description
Additional metrics(cooling system status,power supply status,processor status) support added to existing template(Dell iDRAC Monitors) for Dell iDRAC. Monitors Global storage status,global system status,LCD status and power status. Virtual Disk,Physical Disk,Memory(DIMMs),CPU,Power Supply,Power Unit,Fan,Battery,Temperature Sensor,BIOS,Voltage,Amperage,. Tested on Dell iDRAC PowerEdge R720 and R620 devices.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell iDRAC Amperage Reading in Amps | dell.idrac.amperage.reading.amps | Amperage Reading in Amps | amps | Represents the power usage that the probe is reading in Amps. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6] |
Dell iDRAC Amperage Reading in Milliamps | dell.idrac.amperage.reading.milliamps | Amperage Reading in Milliamps | mA | Represents the power usage that the probe is reading in Milliamps. It monitors only when amperageProbeType is other than amperageProbeTypeIsDiscrete,amperageProbeTypeIsPowerSupplyAmps,amperageProbeTypeIsPowerSupplyWatts,amperageProbeTypeIsSystemAmps or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6] |
Dell iDRAC Amperage Reading in Watts | dell.idrac.amperage.reading.watts | Amperage Reading in Watts | W | Represents the power usage that the probe is reading in Watts. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyWatts or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6] |
Dell iDRAC Amperage Status | dell.idrac.amperage.probe.status | Amperage Probe Status | Represents the probe status of the amperage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.5] | |
Dell iDRAC Chassis Status | dell.idrac.system.chassis.status | Chassis Status | Represents the status of the system chassis.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.10.1.4,1.3.6.1.4.1.674.10892.5.4.300.10.1.7] | |
Dell iDRAC CPU Status | dell.idrac.cpu.status | CPU Status | Monitors the status of the processor device status probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6,1.3.6.1.4.1.674.10892.5.4.1100.32.1.7,1.3.6.1.4.1.674.10892.5.4.1100.30.1.5,1.3.6.1.4.1.674.10892.5.4.1100.30.1.8] | |
Dell iDRAC Enclosure Power Supplies | dell.idrac.enclosure.powersupplies.status | Enclosures Power Supplies | Monitors the status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other,2: Unknown,3: OK,4: Non-critical,5: Critical,6: Non-recoverable.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9] | |
Dell iDRAC Fan Reading | dell.idrac.fan.speed | Fan Speed | rpm | Represents the reading for a cooling device of subtypes (coolingDeviceSubTypeIsAFanThatReadsInRPM and coolingDeviceSubTypeIsAPowerSupplyFanThatReadsinRPM) [OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.6] |
Dell iDRAC Fan Status | dell.idrac.fan.status | Fan Status | Represents the status of the probe status of the cooling device/fan.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.12.1.2,1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8] | |
Dell iDRAC Intrusion Status | dell.idrac.intrusion.reading | Intrusion Sensor Reading | It represents the intrusion reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.8] | |
dell.idrac.intrusion.status | Intrusion Sensor Status | The status of the intrusion sensor.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.5,1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.7,1.3.6.1.4.1.674.10892.5.4.300.70.1.8] | ||
Dell iDRAC Memory(DIMMs) Status | dell.idrac.memory.status | Memory (DIMMs) Status | Represents the status of the memory(DIMMs).[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5,1.3.6.1.4.1.674.10892.5.4.1100.50.1.8,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14] | |
Dell iDRAC Physical Disk Status | dell.idrac.phydisk.status | Physical Disk Status | The current state of this physical disk. Possible states - 1: unknown - The current state could not be determined. 2: ready - The physical disk is available for use,but no RAID configuration has been assigned. 3: online - A RAID configuration has been assigned to the physical disk. 4: foreign - The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: offline - The physical disk is not available to the RAID controller. 6: blocked - The physical disk is currently blocked by controller. 7: failed - The physical disk is not operational. 8: non-raid - The physical disk is not a RAID capable disk 9: removed - The physical disk has been removed.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4] | |
dell.idrac.phydisk.smart.status | Physical Disk Smart Status | Monitors whether the physical disk has received a predictive failure alert or not. Possible values are 0(False),1(True). It generates alert if it is True.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31] | ||
Dell iDRAC Power Supply Status | dell.idrac.powersupply.status | Power Supply Status | Monitors the status of the power supply.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.7,1.3.6.1.4.1.674.10892.5.4.600.12.1.8,1.3.6.1.4.1.674.10892.5.4.600.12.1.11,1.3.6.1.4.1.674.10892.5.4.600.12.1.12] | |
Dell iDRAC System Battery Status | dell.idrac.system.battery.reading | Battery Reading | It represents the battery reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7] | |
dell.idrac.system.battery.status | Battery Status | It represents the status of the battery.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.5,1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7] | ||
Dell iDRAC System BIOS Status | dell.idrac.system.bios.status | BIOS Status | Represents the status of the system BIOS.[OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5] | |
Dell iDRAC System Hardware Status | dell_idrac_SystemStateCoolingDeviceStatus | Dell iDRAC System Cooling Device Status | Monitors the dell idrac cooling system status.[IDRAC-MIB::systemStateCoolingDeviceStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.21].Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6). | |
dell_idrac_SystemStateProcessorDeviceStatus | Dell iDRAC System Processor Device Status | Monitors the dell idrac processor status.[IDRAC-MIB::systemStateProcessorDeviceStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.50].Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6) . | ||
dell_idrac_SystemStatePowerUnitStatus | Dell iDRAC System Power Unit Status | Monitors the dell idrac power supply status.[IDRAC-MIB::systemStatePowerUnitStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.42].Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6). | ||
Dell iDRAC System Stats | dell.idrac.system.lcd.status | LCD Status | Indicates the system status as it is reflected by the LCD front panel. Not all system components may be included. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.2.0] | |
dell.idrac.global.storage.status | Global Storage Status | Indicates the overall storage status being monitored by the remote access card. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.3.0] | ||
dell.idrac.global.system.status | Global System Status | Indicates the overall rollup status of all components in the system being monitored by the remote access card. Includes system,storage,IO devices,iDRAC,CPU,memory,etc. Possible status values are 1- Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6-nonRecoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.1.0] | ||
dell.idrac.system.power.state | Power State | Indicates the power state of the system. Possible status values are 1: Other,2- Unknown,3- Off,4- On.[OID: 1.3.6.1.4.1.674.10892.5.2.4.0] | ||
Dell iDRAC Temperature | dell.idrac.temperature.reading | Temperature Reading | C | It represents the reading for a temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.8] |
dell.idrac.temperature.status | Temperature Status | It represents the probe status of the temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.7,1.3.6.1.4.1.674.10892.5.4.700.20.1.8] | ||
Dell iDRAC Virtual Disk Status | dell.idrac.virtual.disk.status | Virtual Disk Status | Represents the current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.3] | |
dell.idrac.virtual.disk.badblocks | is Virtual Disk has Bad Blocks ? | Indicates whether the virtual disk has bad blocks.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23] | ||
Dell iDRAC Voltage | dell.idrac.voltage.prob.reading | Voltage Probe Reading | v | Monitors the power supply voltage probe reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.20.1.6,1.3.6.1.4.1.674.10892.5.4.600.20.1.8] |
dell.idrac.voltage.prob.status | Voltage Probe Status | Represents the probe status of the voltage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.5] |
Dell iDRAC Monitors - v3
Description
Additional metrics( Status,Cumulative Wattage,Peak Watts,Peak Amps) support added to existing template(Dell iDRAC Monitors - v2) for Dell iDRAC. Monitors Global storage status,global system status,LCD status and power status. Virtual Disk,Physical Disk,Memory(DIMMs),CPU,Power Supply,Power Unit,Fan,Battery,Temperature Sensor,BIOS,Voltage,Amperage,cooling system status,power supply status,processor status Tested on Dell iDRAC PowerEdge R720 and R620 devices.
Prerequisites
NULL
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell iDRAC System Stats | dell.idrac.global.system.status | Global System Status | None | Indicates the overall rollup status of all components in the system being monitored by the remote access card. Includes system,storage,IO devices,iDRAC,CPU,memory,etc. Possible status values are 1- Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6-nonRecoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.1.0] |
Dell iDRAC System Battery Status | dell.idrac.system.battery.reading | Battery Reading | It represents the battery reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7] | |
Dell iDRAC Enclosure Power Supplies | dell.idrac.enclosure.powersupplies.status | Enclosures Power Supplies | Monitors the status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other,2: Unknown,3: OK,4: Non-critical,5: Critical,6: Non-recoverable.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9] | |
Dell iDRAC Memory(DIMMs) Status | dell.idrac.memory.status | Memory (DIMMs) Status | Represents the status of the memory(DIMMs).[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5,1.3.6.1.4.1.674.10892.5.4.1100.50.1.8,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14] | |
Dell iDRAC Intrusion Status | dell.idrac.intrusion.status | Intrusion Sensor Status | The status of the intrusion sensor.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.5,1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.7,1.3.6.1.4.1.674.10892.5.4.300.70.1.8] | |
Dell iDRAC Voltage | dell.idrac.voltage.prob.reading | Voltage Probe Reading | v | Monitors the power supply voltage probe reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.20.1.6,1.3.6.1.4.1.674.10892.5.4.600.20.1.8] |
Dell iDRAC Power Usage Statistics | dell_idrac_PowerUsageCumulativeWattage_Watthours | Dell iDRAC Total Power Wattage used(in Watt-hours) | Dell iDRAC total power wattage used(in Watt-hours).[IDRAC-MIB::powerUsageCumulativeWattage:1.3.6.1.4.1.674.10892.5.4.600.60.1.7] | |
Dell iDRAC Temperature | dell.idrac.temperature.reading | Temperature Reading | C | It represents the reading for a temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.8] |
Dell iDRAC System Battery Status | dell.idrac.system.battery.status | Battery Status | It represents the status of the battery.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.50.1.5,1.3.6.1.4.1.674.10892.5.4.600.50.1.6,1.3.6.1.4.1.674.10892.5.4.600.50.1.7] | |
Dell iDRAC Intrusion Status | dell.idrac.intrusion.reading | Intrusion Sensor Reading | It represents the intrusion reading.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.70.1.6,1.3.6.1.4.1.674.10892.5.4.300.70.1.8] | |
Dell iDRAC Amperage Reading in Watts | dell.idrac.amperage.reading.watts | Amperage Reading in Watts | W | Represents the power usage that the probe is reading in Watts. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyWatts or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6] |
Dell iDRAC Fan Status | dell.idrac.fan.status | Fan Status | Represents the status of the probe status of the cooling device/fan.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.12.1.2,1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8] | |
Dell iDRAC Physical Disk Status | dell.idrac.phydisk.status | Physical Disk Status | The current state of this physical disk. Possible states - 1: unknown - The current state could not be determined. 2: ready - The physical disk is available for use,but no RAID configuration has been assigned. 3: online - A RAID configuration has been assigned to the physical disk. 4: foreign - The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: offline - The physical disk is not available to the RAID controller. 6: blocked - The physical disk is currently blocked by controller. 7: failed - The physical disk is not operational. 8: non-raid - The physical disk is not a RAID capable disk 9: removed - The physical disk has been removed.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4] | |
Dell iDRAC Amperage Reading in Amps | dell.idrac.amperage.reading.amps | Amperage Reading in Amps | amps | Represents the power usage that the probe is reading in Amps. It monitors only when amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6] |
Dell iDRAC System Stats | dell.idrac.system.lcd.status | LCD Status | None | Indicates the system status as it is reflected by the LCD front panel. Not all system components may be included. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.2.0] |
Dell iDRAC Power Usage Statistics | dell_idrac_PowerUsagePeakAmps | Dell iDRAC Power Usage Peak Amps | amps | Monitors the dell iDRAC power usage peak amps.[IDRAC-MIB::powerUsagePeakAmps:1.3.6.1.4.1.674.10892.5.4.600.60.1.12] |
Dell iDRAC Virtual Disk Status | dell.idrac.virtual.disk.badblocks | is Virtual Disk has Bad Blocks ? | Indicates whether the virtual disk has bad blocks.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23] | |
Dell iDRAC System Stats | dell.idrac.system.power.state | Power State | None | Indicates the power state of the system. Possible status values are 1: Other,2- Unknown,3- Off,4- On.[OID: 1.3.6.1.4.1.674.10892.5.2.4.0] |
Dell iDRAC System Hardware Status | dell_idrac_SystemStateProcessorDeviceStatus | Dell iDRAC System Processor Device Status | Monitors the dell idrac processor status.[IDRAC-MIB::systemStateProcessorDeviceStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.50].Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6) . | |
Dell iDRAC Amperage Status | dell.idrac.amperage.probe.status | Amperage Probe Status | Represents the probe status of the amperage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.5] | |
Dell iDRAC System BIOS Status | dell.idrac.system.bios.status | BIOS Status | Represents the status of the system BIOS.[OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5] | |
Dell iDRAC System Hardware Status | dell_idrac_SystemStateCoolingDeviceStatus | Dell iDRAC System Cooling Device Status | Monitors the dell idrac cooling system status.[IDRAC-MIB::systemStateCoolingDeviceStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.21].Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6). | |
Dell iDRAC System Stats | dell.idrac.global.storage.status | Global Storage Status | None | Indicates the overall storage status being monitored by the remote access card. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.3.0] |
Dell iDRAC Fan Reading | dell.idrac.fan.speed | Fan Speed | rpm | Represents the reading for a cooling device of subtypes (coolingDeviceSubTypeIsAFanThatReadsInRPM and coolingDeviceSubTypeIsAPowerSupplyFanThatReadsinRPM) [OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.6] |
Dell iDRAC Chassis Status | dell.idrac.system.chassis.status | Chassis Status | Represents the status of the system chassis.[OIDs: 1.3.6.1.4.1.674.10892.5.4.300.10.1.4,1.3.6.1.4.1.674.10892.5.4.300.10.1.7] | |
Dell iDRAC Power Supply Status | dell.idrac.powersupply.status | Power Supply Status | Monitors the status of the power supply.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.7,1.3.6.1.4.1.674.10892.5.4.600.12.1.8,1.3.6.1.4.1.674.10892.5.4.600.12.1.11,1.3.6.1.4.1.674.10892.5.4.600.12.1.12] | |
Dell iDRAC Amperage Reading in Milliamps | dell.idrac.amperage.reading.milliamps | Amperage Reading in Milliamps | mA | Represents the power usage that the probe is reading in Milliamps. It monitors only when amperageProbeType is other than amperageProbeTypeIsDiscrete,amperageProbeTypeIsPowerSupplyAmps,amperageProbeTypeIsPowerSupplyWatts,amperageProbeTypeIsSystemAmps or amperageProbeTypeIsSystemWatts.[OIDs: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6] |
Dell iDRAC Voltage | dell.idrac.voltage.prob.status | Voltage Probe Status | Represents the probe status of the voltage probe.[OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.5] | |
Dell iDRAC Temperature | dell.idrac.temperature.status | Temperature Status | It represents the probe status of the temperature probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.7,1.3.6.1.4.1.674.10892.5.4.700.20.1.8] | |
Dell iDRAC System Hardware Status | dell_idrac_SystemStatePowerUnitStatus | Dell iDRAC System Power Unit Status | Monitors the dell idrac power supply status.[IDRAC-MIB::systemStatePowerUnitStatusCombined:1.3.6.1.4.1.674.10892.5.4.200.10.1.42]. Possible values are other(1),unknown(2),ok(3),nonCritical(4),critical(5),nonRecoverable(6). | |
Dell iDRAC Power Usage Statistics | dell_idrac_PowerUsagePeakWatts | Dell iDRAC Power Usage Peak Watts | W | Monitors the dell iDRAC power usage peak watts.[IDRAC-MIB::powerUsagePeakWatts:1.3.6.1.4.1.674.10892.5.4.600.60.1.9] |
Dell iDRAC CPU Status | dell.idrac.cpu.status | CPU Status | Monitors the status of the processor device status probe.[OIDs: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6,1.3.6.1.4.1.674.10892.5.4.1100.32.1.7,1.3.6.1.4.1.674.10892.5.4.1100.30.1.5,1.3.6.1.4.1.674.10892.5.4.1100.30.1.8] | |
Dell iDRAC Physical Disk Status | dell.idrac.phydisk.smart.status | Physical Disk Smart Status | Monitors whether the physical disk has received a predictive failure alert or not. Possible values are 0(False),1(True). It generates alert if it is True.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31] | |
Dell iDRAC Power Usage Statistics | dell_idrac_PowerUsageStatus | Dell iDRAC Power Usage Status | Monitors the dell iDRAC power usage status.[IDRAC-MIB::powerUsageStatus:1.3.6.1.4.1.674.10892.5.4.600.60.1.5] | |
Dell iDRAC Virtual Disk Status | dell.idrac.virtual.disk.status | Virtual Disk Status | Represents the current state of this virtual disk (which includes any member physical disks.)Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.3] |
Dell iDRAC PowerEdge R440
Description
Template to monitor Global System Status,LCD Status,Global Storage Status,Power State,Virtual Disk Status,is Virtual Disk has Bad Blocks,Physical Disk Status,Physical Disk Smart Status.Validated on iDRAC v9,Firmware version 3.21.26.22,Sysobjectid : 1.3.6.1.4.1.674.10892.5
Prerequisites
The device should have support for IDRAC-MIB-SMIv2.
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell iDRAC Physical Disk Status | dell.idrac.phydisk.status | Physical Disk Status | The current state of this physical disk. Possible states - 1: unknown - The current state could not be determined. 2: ready - The physical disk is available for use,but no RAID configuration has been assigned. 3: online - A RAID configuration has been assigned to the physical disk. 4: foreign - The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: offline - The physical disk is not available to the RAID controller. 6: blocked - The physical disk is currently blocked by controller. 7: failed - The physical disk is not operational. 8: non-raid - The physical disk is not a RAID capable disk 9: removed - The physical disk has been removed.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4] | |
dell.idrac.phydisk.smart.status | Physical Disk Smart Status | Monitors whether the physical disk has received a predictive failure alert or not. Possible values are 0(False),1(True). It generates alert if it is True.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31] | ||
Dell iDRAC System Stats | dell.idrac.global.system.status | Global System Status | Indicates the overall rollup status of all components in the system being monitored by the remote access card. Includes system,storage,IO devices,iDRAC,CPU,memory,etc. Possible status values are 1- Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6-nonRecoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.1.0] | |
dell.idrac.system.lcd.status | LCD Status | Indicates the system status as it is reflected by the LCD front panel. Not all system components may be included. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.2.0] | ||
dell.idrac.global.storage.status | Global Storage Status | Indicates the overall storage status being monitored by the remote access card. Possible status values are 1: Other,2- Unknown,3- OK,4- Non Critical,5- Critical,6- Non Recoverable.[OID: 1.3.6.1.4.1.674.10892.5.2.3.0] | ||
dell.idrac.system.power.state | Power State | Indicates the power state of the system. Possible status values are 1: Other,2- Unknown,3- Off,4- On.[OID: 1.3.6.1.4.1.674.10892.5.2.4.0] | ||
Dell iDRAC Virtual Disk Status | dell.idrac.virtual.disk.status | Virtual Disk Status | Represents the current state of this virtual disk (which includes any member physical disks). Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.[OIDs: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.3] | |
dell.idrac.virtual.disk.badblocks | is Virtual Disk has Bad Blocks ? | Indicates whether the virtual disk has bad blocks.[OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23] |
Dell Networking Chassis
Description
Template to monitor the CPU 5min utilization,memory utilization,power supply status,fan status,stack unit status,stack unit temperature,system uptime.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell Networking Chassis - Fan Status | dell.force10.unit.fan.status | Fan Status | Status of the Fan tray units. Possible values are 1 - Up,2 - Down,3 - Absent.[OID: 1.3.6.1.4.1.6027.3.26.1.4.7.1.4] | |
Dell Networking Chassis - Power Supply Status | dell.force10.unit.power.supply | Power Supply Operational Status | The status of the power supply. Possible values are up(1),down(2),absent(3).[OIDs:1.3.6.1.4.1.6027.3.26.1.4.6.1.4,1.3.6.1.4.1.6027.3.26.1.4.6.1.5] | |
Dell Networking Chassis - Stack Unit Monitor | dell.force10.unit.temperature | Unit Temperature | C | The temperature of the stack unit.[OID: 1.3.6.1.4.1.6027.3.26.1.3.4.1.13] |
dell.force10.stack.unit.status | Stack Unit Status | The current status of the unit. Possible values are 1 - OK,2 - unsupported,3 - codeMismatch,4 - ConfigMismatch,5 - unitDown,6 - notPresent.[OID: 1.3.6.1.4.1.6027.3.26.1.3.4.1.8] | ||
Dell Performance Monitor | system.cpu.utilization | CPU Utilization | % | CPU utilization in percentage for last 5 minutes.[OID:1.3.6.1.4.1.6027.3.26.1.4.4.1.5,1.3.6.1.4.1.6027.3.26.1.4.3.1.4] |
system.memory.util.percent | Memory Utilization | % | Total memory usage in percentage.[OID: 1.3.6.1.4.1.6027.3.26.1.4.4.1.6,1.3.6.1.4.1.6027.3.26.1.4.3.1.6] | |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Dell Networking Sxxxx-ON Series Switches
Description
It is applicable on Dell Networking Sxxxx-ON Series Switches. It monitors the CPU 5min utilization,Memory utilization,Fans status,Power supply status,SNMP trap service status,Global product status and Uptime. This template validated on Dell open network S3048-ON,S4048-ON,S6010-ON series switches. SysObjID: enterprises.6027.1.3.22,enterprises.6027.1.3.23,enterprises.6027.1.3.29
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell Performance Monitor | system.cpu.utilization | CPU Utilization | % | CPU utilization in percentage for last 5 minutes.[OID:1.3.6.1.4.1.6027.3.26.1.4.4.1.5,1.3.6.1.4.1.6027.3.26.1.4.3.1.4] |
system.memory.util.percent | Memory Utilization | % | Total memory usage in percentage.[OID: 1.3.6.1.4.1.6027.3.26.1.4.4.1.6,1.3.6.1.4.1.6027.3.26.1.4.3.1.6] | |
Dell PowerConnect Fan State | system.fan.status | Fan Status | The mandatory state of the fan being instrumented.[OID:1.3.6.1.4.1.674.10895.3000.1.2.110.7.1.1.3] | |
Dell PowerConnect Power Supply Status | hw.dell.powerconnect.power.supply.status | Power Supply Status | The mandatory state of the power supply being instrumented.[OIDs: 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.3,1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.4] | |
Dell PowerConnect Product Global Status | hw.dell.powerconnect.global.status | Global status | Indicates the current status of the Dell PowerConnect product. This is a rollup for the entire product. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. Possible status values are 3- OK: If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure or a SW fatal error condition. 4- Non-critical: If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure or a SW fatal error condition,5- Critical: If at least one fan is not functional,possibly causing a dangerous warming up of the device.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.1.0] | |
Dell PowerConnect SNMP Trap Service Status | hw.dell.powerconnect.traps.flag.status | Dell PowerConnect Product Status Generating Traps Flag | Indicates if this SNMP service is generating SNMP Traps. This variable can take the following values: 1: true - The device is capable and currently configured to generate traps if necessary. 2: false - The device is not capable of generating traps. 3: disabled - The device is capable but not configured.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.6.0] | |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Dell PowerConnect 7000 Series Switches
Description
Monitors the basic system performance monitors like CPU,Memory and Uptime. It also monitors the hardware parameters like Fan,Temperature,Power supply and global status of the system. Tested on PowerConnect 7048,5.1.3.7,VxWorks 6.6.[SysObjId: 1.3.6.1.4.1.674.10895.3035].
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell PowerConnect CPU Utilization - DNOS (fastPathSwitching) | system.cpu.utilization | CPU Utilization | % | Monitors the total CPU Utilization. |
Dell PowerConnect Fan - DNOS (fastPathBoxServices) | hw.dell.powerconnect.fan.status | Fan Status | Indicates the status of fan. | |
hw.dell.powerconnect.fan.speed | Fan Speed | rpm | Monitors the speed of the Fan. | |
Dell PowerConnect Memory Utilization - DNOS (fastPathSwitching) | system.memory.util.percent | Memory Utilization | % | Memory Utilization - Indicates the instances of the memory pool which are currently in use and which are free.[OIDs: 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.1.1.4.1.0,1.3.6.1.4.1.674.10895.5000.2.6132.1.1.1.1.4.2.0] |
Dell PowerConnect Power Supply - DNOS (fastPathBoxServices) | hw.dell.powerconnect.power.supply.status | Power Supply Status | Monitors the status of power supply. | |
Dell PowerConnect Product Global Status | hw.dell.powerconnect.global.status | Global status | Indicates the current status of the Dell PowerConnect product. This is a rollup for the entire product. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. Possible status values are 3- OK: If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure or a SW fatal error condition. 4- Non-critical: If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure or a SW fatal error condition,5- Critical: If at least one fan is not functional,possibly causing a dangerous warming up of the device.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.1.0] | |
Dell PowerConnect Temperature - DNOS (fastPathBoxServices) | hw.dell.powerconnect.temperature.value | Temperature Value | C | Represents the power connect temperature value reported by sensor. |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Dell PowerConnect Ethernet Switch Template - G2
Description
Template for Dell PowerConnect Ethernet Switch. Monitors fan status,power supply status,global status,etc. Tested on PowerConnect 5448 Ethernet switch.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell PowerConnect Fan State | system.fan.status | Fan Status | The mandatory state of the fan being instrumented.[OID:1.3.6.1.4.1.674.10895.3000.1.2.110.7.1.1.3] | |
Dell PowerConnect Physical Sensor Operational Status | entity.physicalsensor.operational.status | Entity Physical Sensor Operational Status | Provides the operational status of the entity physical sensor.[OIDs: 1.3.6.1.4.1.89.83.2.1.1.1.4,1.3.6.1.4.1.89.83.2.1.1.1.5] | |
Dell PowerConnect Power Supply Status | hw.dell.powerconnect.power.supply.status | Power Supply Status | The mandatory state of the power supply being instrumented.[OIDs: 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.3,1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.4] | |
Dell PowerConnect Product Global Status | hw.dell.powerconnect.global.status | Global status | Indicates the current status of the Dell PowerConnect product. This is a rollup for the entire product. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. Possible status values are 3- OK: If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure or a SW fatal error condition. 4- Non-critical: If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure or a SW fatal error condition,5- Critical: If at least one fan is not functional,possibly causing a dangerous warming up of the device.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.1.0] | |
Dell PowerConnect Radlan Fan Data Temperature | radlan.environment.fandata.temperature | Radlan Environment Fan Data Temperature | C | Provides the unit temperature for Radlan environment fan data temperature.[OIDs: 1.3.6.1.4.1.89.83.2.1.1.1.1,1.3.6.1.4.1.89.83.2.1.1.1.2] |
Dell PowerConnect SNMP Trap Service Status | hw.dell.powerconnect.traps.flag.status | Dell PowerConnect Product Status Generating Traps Flag | Indicates if this SNMP service is generating SNMP Traps. This variable can take the following values: 1: true - The device is capable and currently configured to generate traps if necessary. 2: false - The device is not capable of generating traps. 3: disabled - The device is capable but not configured.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.6.0] |
Dell PowerConnect M8024 Switches
Description
Monitors the basic system performance monitors like CPU,Memory and Uptime. It also monitors the hardware parameters like Temperature and Power supply status. Tested on PowerConnect M8024,5.1.4.5,VxWorks 6.6.[SysObjId: 1.3.6.1.4.1.674.10895.3022].
Note: CPU Utilization monitor work with OpsRamp Gateway v2.6.0 release and later releases only.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell PowerConnect M8024 CPU Utilization | system.cpu.utilization | CPU Utilization | % | Monitors the total CPU Utilization. |
Dell PowerConnect M8024 Power Supply | hw.dell.powerconnect.power.supply.status | Power Supply Status | Monitors the status of power supply. | |
Dell PowerConnect M8024 Temperature | hw.dell.powerconnect.temperature.value | Temperature Value | C | Represents the power connect temperature value reported by sensor. |
Dell PowerConnect Memory Utilization | system.memory.util.percent | Memory Utilization | % | Memory Utilization - Indicates the instances of the memory pool which are currently in use and which are free.[OIDs: 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.1.1.4.1.0,1.3.6.1.4.1.674.10895.5000.2.6132.1.1.1.1.4.2.0] |
Dell PowerConnect Product Global Status | hw.dell.powerconnect.global.status | Global status | Indicates the current status of the Dell PowerConnect product. This is a rollup for the entire product. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. Possible status values are 3- OK: If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure or a SW fatal error condition. 4- Non-critical: If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure or a SW fatal error condition,5- Critical: If at least one fan is not functional,possibly causing a dangerous warming up of the device.[OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.1.0] | |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Dell Server Status - G2
Description
Default monitoring and alerting template for Dell Servers. Monitors chassis intrusion detection reading,memory status,system board fan speed,etc.,
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell Server Array Controller Status | arraycontroller.status | Array Controller Status | Monitors the status of the controller itself without the propagation of any contained component status. Possible values are 1- Other,2- Unknown,3- OK,4- Non-critical,5- Critical,6- Non-recoverable.[OIDs: 1.3.6.1.4.1.674.10893.1.20.130.1.1.2,1.3.6.1.4.1.674.10893.1.20.130.1.1.38] | |
arraycontroller.component.status.all | Array Controller and all Components Status | Monitors the severity of the controller state. This is the combined status of the controller and its components. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10893.1.20.130.1.1.2,1.3.6.1.4.1.674.10893.1.20.130.1.1.37] | ||
Dell Server Array Disk Component Status | dell.arraydisk.component.status | Array Disk Component Status | Monitors the status of the array disk itself without the propagation of any contained component status. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10893.1.20.130.4.1.2,1.3.6.1.4.1.674.10893.1.20.130.4.1.24] | |
Dell Server Baseboard Power Supply Status | dell.baseboard.powersupply.status | Power Supply Status | Represents the status of the Dell baseboard power supply.[OID: 1.3.6.1.4.1.674.10892.1.600.12.1.5] | |
dell.baseboard.powersupply.sensor.status | Power Supply Sensor Status | This attribute defines the state reported by the power supply sensor. This attribute supplements the attribute powerSupplyStateSettingsUnique.[OID: 1.3.6.1.4.1.674.10892.1.600.12.1.11,1.3.6.1.4.1.674.10892.1.600.12.1.4] | ||
Dell Server Chassis Intrusion | hw.chasis.intrusion.detection.reading | Chassis Intrusion Detection Reading | Monitors the the reading of the intrusion sensor. Possible values are 1- chassisNotBreached,2- chassisBreached,3- chassisBreachedPrior,4- chassisBreachSensorFailure.[OIDs: 1.3.6.1.4.1.674.10892.1.300.70.1.2.1,1.3.6.1.4.1.674.10892.1.300.70.1.6.1] | |
Dell Server Chassis Intrusion Sensor Status | hw.chasis.intrusion.obj.status | Chassis Intrusion Object Status | Monitors the status of the intrusion sensor. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10892.1.300.70.1.2,1.3.6.1.4.1.674.10892.1.300.70.1.5] | |
Dell Server Memory Device Status | dell.memory.device.status | Memory Device Status | Monitors the status of the memory device. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10892.1.1100.50.1.2.1,1.3.6.1.4.1.674.10892.1.1100.50.1.5.1] | |
Dell Server Processor Device Status | dell.processor.device.status | Processor Device Status | Monitors the status of the processor device. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10892.1.1100.30.1.2.1,1.3.6.1.4.1.674.10892.1.1100.30.1.5.1] | |
dell.processor.device.status.state | Processor Device Status State | Monitors the status state of the processor device. Possible values are 1- other,2- unknown,3- enabled,4- userDisabled,5- biosDisabled,6- idle.[OIDs: 1.3.6.1.4.1.674.10892.1.1100.30.1.2.1,1.3.6.1.4.1.674.10892.1.1100.30.1.9.1] | ||
Dell Server System Board BIOS Status | dell.hw.bios.status | System Board BIOS Status | Monitors the status of the system BIOS. Possible values are 1- other,2- unknown,3- ok,4- nonCritical,5- critical,6- nonRecoverable.[OIDs: 1.3.6.1.4.1.674.10892.1.300.50.1.2,1.3.6.1.4.1.674.10892.1.300.50.1.5] | |
Dell Server System Board Fan Speed | dell.systemboard.fan.speed | System Board Fan Speed | rpm | Monitors the system board fan speed.[OIDs: 1.3.6.1.4.1.674.10892.1.700.12.1.2.1,1.3.6.1.4.1.674.10892.1.700.12.1.6.1] |
Dell Server Voltage Probe Status | dell.voltage.probe.status | Voltage Probe Status | Monitors the probe status of the voltage probe. :Possible values are 1- other,2- unknown,3- ok,4- nonCriticalUpper,5- criticalUpper,6- nonRecoverableUpper,7- nonCriticalLower,8- criticalLower,9- nonRecoverableLower,10- failed.[OIDs: 1.3.6.1.4.1.674.10892.1.600.20.1.2.1,1.3.6.1.4.1.674.10892.1.600.20.1.5.1] |
Dell SonicWall NSA 240 - G2
Description
Applicable on the SonicWall NSA series firewall appliance- SonicWALL NSA 240. Sys OID- 1.3.6.1.4.1.8741.1. Monitors VPN Performance,Health,Active Connections.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Sonicwall NSA Health | sonicwall.nsa.cpu.utilization | CPU Utilization | % | Provides the instantaneous CPU Utilization in percent.[OID: 1.3.6.1.4.1.8741.1.3.1.3.0] |
sonicwall.nsa.ram.utilization | Sonicwall RAM Utilization | % | Provides the instantaneous RAM Utilization in percent.[OID: 1.3.6.1.4.1.8741.1.3.1.4.0] | |
sonicwall.nsa.active.connections | Sonicwall Active Connections | The number of active connections currently being managed by the SonicWALL firewall.[OID: 1.3.6.1.4.1.8741.1.3.1.2.0] | ||
Sonicwall VPN Performance | sonicwall.vpn.encrypt.bytes | Encrypted Bytes | Bps | VPN Performance - rate of encrypted traffic flowing through the IPSec tunnel [OID: 1.3.6.1.4.1.8741.1.3.2.1.1.1.2,1.3.6.1.4.1.8741.1.3.2.1.1.1.3,1.3.6.1.4.1.8741.1.3.2.1.1.1.9] |
sonicwall.vpn.decrypt.bytes | Decrypted Bytes | Bps | VPN Performance - rate of decrypted traffic flowing through the IPSec tunnel [OID: 1.3.6.1.4.1.8741.1.3.2.1.1.1.2,1.3.6.1.4.1.8741.1.3.2.1.1.1.3,1.3.6.1.4.1.8741.1.3.2.1.1.1.11] | |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Dell UPS
Description
Template to monitor Dell UPS global status,Load Segment parameters like Load Segment1 Shutdown After Delay,Load Segment2 Shutdown After Delay,physical battery parameters like AMB(Advanced Battery Monitoring) Status,Seconds Remaining,Test Status,Physical Output parameters like Cumulative Consumption,Instant Headroom,Peak Consumption,Peak Headroom,Present Consumption,Output VA,Physical Rectifier parameters like Negative Voltage,Positive Voltage. sysObjectID:1.3.6.1.4.1.674.10902.2
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Dell UPS - Global Status | dell.ups.global.status | Global Status | It monitors the current status of the product.Possible values are 1: other,2: unknown,3: ok,4: non-critical,5: critical,6: non-recoverable.[DELL-SNMP-UPS-MIB::productStatusGlobalStatus:1.3.6.1.4.1.674.10902.2.110.1.0]. | |
Dell UPS - Load Segment | dell.ups.physical.load.segment2.shutdown.after.delay | Physical Load Segment2 Shutdown After Delay | s | It monitors the number of seconds remaining until load segment 2 will switch off. -1 if no shutdown countdown is in effect.[DELL-SNMP-UPS-MIB::physicalLoadSegment2ShutdownAfterDelay:1.3.6.1.4.1.674.10902.2.120.6.3.0]. |
dell.ups.physical.load.segment1.shutdown.after.delay | Physical Load Segment1 Shutdown After Delay | s | It monitors the number of seconds remaining until load segment 1 will switch off. -1 if no shutdown countdown is in effect.[DELL-SNMP-UPS-MIB::physicalLoadSegment1ShutdownAfterDelay:1.3.6.1.4.1.674.10902.2.120.6.1.0]. | |
Dell UPS - Physical Battery | dell.ups.physical.battery.seconds.remaining | Physical Battery Seconds Remaining | s | It monitors the battery remaining time calculated by the autonometer in seconds.[DELL-SNMP-UPS-MIB::physicalBatterySecondsRemaining:1.3.6.1.4.1.674.10902.2.120.5.3.0]. |
dell.ups.physical.battery.test.status | Physical Battery Test Status | It monitors the battery test status. Possible values are 1: donePassed,2: doneWarning,3: doneError,4: aborted,5: inProgress,6: noTestIniated,7: testScheduled.[DELL-SNMP-UPS-MIB::physicalBatteryTestStatus:1.3.6.1.4.1.674.10902.2.120.5.2.0]. | ||
dell.ups.physical.battery.amb.status | Physical Battery AMB(Advanced Battery Monitoring) Status | It monitors the advanced battery monitoring(AMB) status.Possible values are 1: abmCharging,2: abmDischarging,3: abmFloating,4: abmResting,5: abmOff.[DELL-SNMP-UPS-MIB::physicalBatteryABMStatus:1.3.6.1.4.1.674.10902.2.120.5.1.0]. | ||
Dell UPS - Physical Output | dell.ups.physical.output.cumulative.consumption | Physical Output Cumulative Consumption | It monitors the 64 bit meter value that is derived by reading the Present KWH Consumption meter once per hour and adding it to the last value of this meter.[DELL-SNMP-UPS-MIB::physicalOutputCumulativeConsumption:1.3.6.1.4.1.674.10902.2.120.2.7.0]. | |
dell.ups.physical.output.peak.headroom | Physical Output Peak Headroom | W | It monitors the statistical value holding the lowest value that Instantaneous Headroom Watts was ever set too since the last time this statistic was reset.[DELL-SNMP-UPS-MIB::physicalOutputPeakHeadroom:1.3.6.1.4.1.674.10902.2.120.2.2]. | |
dell.ups.physical.output.present.consumption | Physical Output Present Consumption | It monitors the watt second consumption over the past hour.[DELL-SNMP-UPS-MIB::physicalOutputPresentConsumption:1.3.6.1.4.1.674.10902.2.120.2.6.0]. | ||
dell.ups.physical.output.va | Physical Output VA(volt-ampere) | It monitors the physical output VA(volt-ampere) .[DELL-SNMP-UPS-MIB::physicalOutputVA:1.3.6.1.4.1.674.10902.2.120.2.9.0]. | ||
dell.ups.physical.output.instant.headroom | Physical Output Instant Headroom | W | It monitors the present amount of watt capacity remaining before overload.[DELL-SNMP-UPS-MIB::physicalOutputInstantHeadroom:1.3.6.1.4.1.674.10902.2.120.2.1.0]. | |
dell.ups.physical.output.peak.consumption | Physical Output Peak Consumption (RMS Watts) | It monitors the statistical value of the maximum RMS Watts the UPS has seen since the last time this statistic was reset.[DELL-SNMP-UPS-MIB::physicalOutputPeakConsumption,1.3.6.1.4.1.674.10902.2.120.2.4.0]. | ||
Dell UPS - Physical Rectifier | dell.ups.physical.rectifier.negative.voltage | Physical Rectifier Negative Voltage | v | It monitors the DC bus negative voltage.[DELL-SNMP-UPS-MIB::physicalRectifierNegVoltage:1.3.6.1.4.1.674.10902.2.120.3.2.0]. |
dell.ups.physical.rectifier.positive.voltage | Physical Rectifier Positive Voltage | v | It monitors the DC bus positive voltage.[DELL-SNMP-UPS-MIB::physicalRectifierPosVoltage:1.3.6.1.4.1.674.10902.2.120.3.1.0]. |