Description

It monitors the ONL (Open Network Linux) hardware parameters like Fan status,Fan speed,Power supply status,Temperature reading and Temperature status. Validated on Switch Light OS SWL-OS-BCF-4.0.0(0) and BMF(Big Monitoring Fabric)-6.1.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
ONL (Open Network Linux) - Fanocp.onl.fan.statusFan StatusIt monitors the ONL(Open Network Linux) fan status.[OCP-ONL-SENSOR-MIB OIDs: 1.3.6.1.4.1.42623.1.2.2.1.2,1.3.6.1.4.1.42623.1.2.2.1.3,1.3.6.1.4.1.42623.1.2.2.1.5].
ocp.onl.fan.speedFan SpeedrpmIt monitors the ONL(Open Network Linux) fan sensor speed in RPM.[OIDs: 1.3.6.1.4.1.42623.1.2.2.1.2,1.3.6.1.4.1.42623.1.2.2.1.3,1.3.6.1.4.1.42623.1.2.2.1.5].
ONL (Open Network Linux) - Power Supply Statusocp.onl.psu.statusPower Supply StatusIt monitors the ONL (Open Network Linux) power supply unit sensors status.[OIDs: 1.3.6.1.4.1.42623.1.2.3.1.2,1.3.6.1.4.1.42623.1.2.3.1.3,1.3.6.1.4.1.42623.1.2.3.1.4].
ONL (Open Network Linux) - Temperatureocp.onl.temperature.statusTemperature StatusIt monitors the ONL (Open Network Linux) Temperature sensor status.[OIDs: 1.3.6.1.4.1.42623.1.2.1.1.2,1.3.6.1.4.1.42623.1.2.1.1.3,1.3.6.1.4.1.42623.1.2.1.1.4].
ocp.onl.temperature.valueTemperature in mCIt monitors the ONL (Open Network Linux) Temperature sensor reading in mC.[OCP-ONL-SENSOR-MIB OIDs: 1.3.6.1.4.1.42623.1.2.1.1.2,1.3.6.1.4.1.42623.1.2.1.1.3,1.3.6.1.4.1.42623.1.2.1.1.4].

Big Switch Networks - SwitchLight Performance

Description

Monitors the Big Switch Networks - Switch Light performance metrics like host cpu utilization,number of TCAM (Ternary content addressable memory) FULLMATCH free entries available and TCAM (Ternary content addressable memory) FULLMATCH utilization.

Note: Currently this template created for BSN(Big Switch Network) BMF (Big Monitoring Fabric) 6.1 device but it also may work for BCF (Big Cloud Fabric) device. Modify baselines as per your organization needs while copying this template to partner/client level.

Prerequisites

No prerequisite

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
BigSwitch Network Switchlight - TCAM Performancebsn.switch.light.tcam.freeTCAM FULLMATCH Free EntriesRepresents the number of Ternary content addressable memory (TCAM) FULLMATCH free etries in BigSwitch Network Switchlight.[BIGSWITCH-SWITCHLIGHT-MIB OIDs: 1.3.6.1.4.1.37538.2.1.2.1.0,1.3.6.1.4.1.37538.2.1.2.2.0,1.3.6.1.4.1.37538.2.1.2.3.0].
bsn.switch.light.tcam.utilizationTCAM FULLMATCH UtilizationRepresents the Ternary content addressable memory (TCAM) FULLMATCH utilization in BigSwitch Network Switchlight.[BIGSWITCH-SWITCHLIGHT-MIB OIDs: 1.3.6.1.4.1.37538.2.1.2.1.0,1.3.6.1.4.1.37538.2.1.2.2.0,1.3.6.1.4.1.37538.2.1.2.3.0].
ONL (Open Network Linux) - Host CPU Utilizationonl.cpu.utilizationCPU Utilization%Represents the Open Network Linux(ONL) host average CPU utilization in percent,multiplied by 100 and rounded to the nearest integer. Provided by mpstat.[OID: 1.3.6.1.4.1.42623.1.3.1.1.0].