Big Switch Networks - Hardware Monitors
Description
It monitors the ONL (Open Network Linux) hardware parameters like Fan status,Fan speed,Power supply status,Temperature reading and Temperature status. Validated on Switch Light OS SWL-OS-BCF-4.0.0(0) and BMF(Big Monitoring Fabric)-6.1.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
ONL (Open Network Linux) - Fan | ocp.onl.fan.status | Fan Status | It monitors the ONL(Open Network Linux) fan status.[OCP-ONL-SENSOR-MIB OIDs: 1.3.6.1.4.1.42623.1.2.2.1.2,1.3.6.1.4.1.42623.1.2.2.1.3,1.3.6.1.4.1.42623.1.2.2.1.5]. | |
ocp.onl.fan.speed | Fan Speed | rpm | It monitors the ONL(Open Network Linux) fan sensor speed in RPM.[OIDs: 1.3.6.1.4.1.42623.1.2.2.1.2,1.3.6.1.4.1.42623.1.2.2.1.3,1.3.6.1.4.1.42623.1.2.2.1.5]. | |
ONL (Open Network Linux) - Power Supply Status | ocp.onl.psu.status | Power Supply Status | It monitors the ONL (Open Network Linux) power supply unit sensors status.[OIDs: 1.3.6.1.4.1.42623.1.2.3.1.2,1.3.6.1.4.1.42623.1.2.3.1.3,1.3.6.1.4.1.42623.1.2.3.1.4]. | |
ONL (Open Network Linux) - Temperature | ocp.onl.temperature.status | Temperature Status | It monitors the ONL (Open Network Linux) Temperature sensor status.[OIDs: 1.3.6.1.4.1.42623.1.2.1.1.2,1.3.6.1.4.1.42623.1.2.1.1.3,1.3.6.1.4.1.42623.1.2.1.1.4]. | |
ocp.onl.temperature.value | Temperature in mC | It monitors the ONL (Open Network Linux) Temperature sensor reading in mC.[OCP-ONL-SENSOR-MIB OIDs: 1.3.6.1.4.1.42623.1.2.1.1.2,1.3.6.1.4.1.42623.1.2.1.1.3,1.3.6.1.4.1.42623.1.2.1.1.4]. |
Big Switch Networks - SwitchLight Performance
Description
Monitors the Big Switch Networks - Switch Light performance metrics like host cpu utilization,number of TCAM (Ternary content addressable memory) FULLMATCH free entries available and TCAM (Ternary content addressable memory) FULLMATCH utilization.
Note: Currently this template created for BSN(Big Switch Network) BMF (Big Monitoring Fabric) 6.1 device but it also may work for BCF (Big Cloud Fabric) device. Modify baselines as per your organization needs while copying this template to partner/client level.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
BigSwitch Network Switchlight - TCAM Performance | bsn.switch.light.tcam.free | TCAM FULLMATCH Free Entries | Represents the number of Ternary content addressable memory (TCAM) FULLMATCH free etries in BigSwitch Network Switchlight.[BIGSWITCH-SWITCHLIGHT-MIB OIDs: 1.3.6.1.4.1.37538.2.1.2.1.0,1.3.6.1.4.1.37538.2.1.2.2.0,1.3.6.1.4.1.37538.2.1.2.3.0]. | |
bsn.switch.light.tcam.utilization | TCAM FULLMATCH Utilization | Represents the Ternary content addressable memory (TCAM) FULLMATCH utilization in BigSwitch Network Switchlight.[BIGSWITCH-SWITCHLIGHT-MIB OIDs: 1.3.6.1.4.1.37538.2.1.2.1.0,1.3.6.1.4.1.37538.2.1.2.2.0,1.3.6.1.4.1.37538.2.1.2.3.0]. | ||
ONL (Open Network Linux) - Host CPU Utilization | onl.cpu.utilization | CPU Utilization | % | Represents the Open Network Linux(ONL) host average CPU utilization in percent,multiplied by 100 and rounded to the nearest integer. Provided by mpstat.[OID: 1.3.6.1.4.1.42623.1.3.1.1.0]. |