Description

Monitors the Allied Telesis AlliedWare Plus Performance Statistics like Cpu Utilisation Average 5 Minutes,Memory Utilization and Stack Cpu Utilisation Average 5Minutes.[AT-SYSINFO-MIB :: cpuUtilisationAvgLast5Minutes : 1.3.6.1.4.1.207.8.4.4.3.3.7.0,freeMemory : 1.3.6.1.4.1.207.8.4.4.3.7.1.0,cpuUtilisationStackAvgLast5Minutes : 1.3.6.1.4.1.207.8.4.4.3.3.8.1.8]

Prerequisites

Device must have support for AT-SYSINFO-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Allied Telesis - PerformancealliedTelesis_CpuUtilisationAvg5MinutesAllied Telesis Cpu Utilisation Average 5Minutes%Monitos the average CPU utilisation over the past 5 minutes.[AT-SYSINFO-MIB :: cpuUtilisationAvgLast5Minutes : 1.3.6.1.4.1.207.8.4.4.3.3.7.0]
alliedTelesis_memoryUtilizationAllied Telesis Memory Utilization%Monitors the Allied Telesis Memory Utilization.[AT-SYSINFO-MIB :: freeMemory : 1.3.6.1.4.1.207.8.4.4.3.7.1.0]
Allied Telesis - Stack CpuAllied Telesis - Stack CpualliedTelesis_CpuUtilisationStackAvg5Minutes%Monitors the average stack CPU utilisation over the past 5 minutes.[AT-SYSINFO-MIB :: cpuUtilisationStackAvgLast5Minutes : 1.3.6.1.4.1.207.8.4.4.3.3.8.1.8]

Allied Telesis - AlliedWare Plus Hardware

Description

Monitors the Allied Telesis AlliedWare Plus Hardware Statistics like Fan Current Speed and Fan Status,Sensor Type,Sensor Status and Sensor Reading,Temperature Current Value and Temperature Status,Voltage and Voltage Status.[AT-ENVMONv2-MIB :: atEnvMonv2FanCurrentSpeed : 1.3.6.1.4.1.207.8.4.4.3.12.1.1.5,atEnvMonv2FanStatus : 1.3.6.1.4.1.207.8.4.4.3.12.1.1.7,atEnvMonv2PsbSensorType : 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.4,atEnvMonv2PsbSensorStatus : 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.6,atEnvMonv2PsbSensorReading : 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.7,atEnvMonv2TemperatureCurrent : 1.3.6.1.4.1.207.8.4.4.3.12.3.1.5,atEnvMonv2TemperatureStatus : 1.3.6.1.4.1.207.8.4.4.3.12.3.1.7,atEnvMonv2VoltageCurrent : 1.3.6.1.4.1.207.8.4.4.3.12.2.1.5,atEnvMonv2VoltageStatus : 1.3.6.1.4.1.207.8.4.4.3.12.2.1.8]

Prerequisites

Device must have support for AT-ENVMONv2-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Allied Telesis - FanalliedTelesis_FanCurrentSpeedAllied Telesis Fan Current SpeedrpmMonitors the current speed of this fan in revolutions per minute.[AT-ENVMONv2-MIB :: atEnvMonv2FanCurrentSpeed : 1.3.6.1.4.1.207.8.4.4.3.12.1.1.5]
alliedTelesis_FanStatusAllied Telesis Fan StatusMonitors the Allied Telesis Fan Status.[AT-ENVMONv2-MIB :: atEnvMonv2FanStatus : 1.3.6.1.4.1.207.8.4.4.3.12.1.1.7] Possible values are : 1 : failed,2 : good.
Allied Telesis - SensoralliedTelesis_SensorTypeAllied Telesis Sensor TypeMonitors the type of environmental variable this sensor detects.[AT-ENVMONv2-MIB :: atEnvMonv2PsbSensorType : 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.4] Possible values are : 0 : psbSensorTypeInvalid,1 : fanSpeedDiscrete,2 : temperatureDiscrete,3 : voltageDiscrete,4 : presenceDiscrete
alliedTelesis_SensorStatusAllied Telesis Sensor StatusMonitors the Allied Telesis Sensor Status.[AT-ENVMONv2-MIB :: atEnvMonv2PsbSensorStatus : 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.6] Possible values are : 1 : failed, 2 : good, 3 : notPowered, 4 : notPresent.
alliedTelesis_SensorReadingAllied Telesis Sensor ReadingMonitors whether this environmental sensor is currently reading a value for the monitored device or not.[AT-ENVMONv2-MIB :: atEnvMonv2PsbSensorReading : 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.7] Possible values are : 1 : no, 2 : yes
Allied Telesis - TemperaturealliedTelesis_TemperatureCurrentAllied Telesis Temperature Current ValueCelsiusMonitors the current reading of this temperature sensor.[AT-ENVMONv2-MIB :: atEnvMonv2TemperatureCurrent : 1.3.6.1.4.1.207.8.4.4.3.12.3.1.5]
alliedTelesis_TemperatureStatusAllied Telesis Temperature StatusMonitors the Allied Telesis Temperature Status.[AT-ENVMONv2-MIB :: atEnvMonv2TemperatureStatus : 1.3.6.1.4.1.207.8.4.4.3.12.3.1.7] Possible values are : 1 : outOfRange,2 : inRange.
Allied Telesis - VoltagealliedTelesis_VoltageCurrentAllied Telesis Voltage CurrentmVMonitors the current reading of this voltage rail in millivolts.[AT-ENVMONv2-MIB :: atEnvMonv2VoltageCurrent : 1.3.6.1.4.1.207.8.4.4.3.12.2.1.5]
alliedTelesis_VoltageStatusAllied Telesis Voltage StatusMonitors the Allied Telesis Voltage Status.[AT-ENVMONv2-MIB :: atEnvMonv2VoltageStatus : 1.3.6.1.4.1.207.8.4.4.3.12.2.1.8] Possible values are : 1 : outOfRange,2 : inRange.

Allied Telesis - AlliedWare Plus Stack Statistics

Description

Monitors the Allied Telesis AlliedWare Plus Stack Statistics like Stack Status,Stack Operational Status and Stack Port Status.[AT-VCSTACK-MIB :: vcstackStatus : 1.3.6.1.4.1.207.8.4.4.3.13.1.0, vcstackOperationalStatus : 1.3.6.1.4.1.207.8.4.4.3.13.2.0, vcstackPortStatus : 1.3.6.1.4.1.207.8.4.4.3.13.12.1.5]

Prerequisites

Device must have support for AT-VCSTACK-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Allied Telesis - StackalliedTelesis_StackStatusAllied Telesis Stack StatusMonitors the overall stack status.[AT-VCSTACK-MIB :: vcstackStatus : 1.3.6.1.4.1.207.8.4.4.3.13.1.0] Possible values are : 1 : normalOperation, 2 : operatingInFailoverState, 3 : standaloneUnit, 4 : ringTopologyBroken, 5 : vcsDisabled,6 : allStkPortsNotUp.
alliedTelesis_StackOperationalStatusAllied Telesis Stack Operational StatusMonitors whether the stack is enabled or disabled.[AT-VCSTACK-MIB :: vcstackOperationalStatus : 1.3.6.1.4.1.207.8.4.4.3.13.2.0] Possible values are : 1 : enabled, 2 : disabled.
Allied Telesis - Stack PortalliedTelesis_StackPortStatusAllied Telesis Stack Port StatusMonitors the status of stack port.[AT-VCSTACK-MIB :: vcstackPortStatus : 1.3.6.1.4.1.207.8.4.4.3.13.12.1.5] Possible values are : 1 : down, 2 : neighbourIncompatible, 3 : discoveringNeighbour, 4 : learntNeighbour.

Allied Telesis - AlliedWare Plus NTP

Description

Monitors the Allied Telesis AlliedWare Plus NTP System Clock Sync and Offset.[AT-NTP-MIB :: atNtpSysClockSync : 1.3.6.1.4.1.207.8.4.4.4.502.11.1.0, atNtpSysClkOffset : 1.3.6.1.4.1.207.8.4.4.4.502.11.7.0]

Prerequisites

Device must have support for AT-NTP-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Allied Telesis - NTPalliedTelesis_NtpSysClockSyncAllied Telesis NTP System Clock SyncMonitors the whether the system clock is synchronized or not.[AT-NTP-MIB :: atNtpSysClockSync : 1.3.6.1.4.1.207.8.4.4.4.502.11.1.0] Possible values are : 1 : true, 2 : false.
alliedTelesis_NtpSysClkOffsetAllied Telesis NTP System Clock OffsetmsMonitors the offset of the local clock relative to the server clock, in milliseconds.[AT-NTP-MIB :: atNtpSysClkOffset : 1.3.6.1.4.1.207.8.4.4.4.502.11.7.0]

Note: The offset represents the time difference and frequency variance between UTC and the system clock. If the offset value is non-zero, an alert will be generated, indicating the need to correct the system clock.