Alaxala AX23AX26S Switch Performance

Description

Monitors the Alaxala AX2300S and AX2600S Switch Performance Statistics like Chassis Status,STS LED Status,Memory Utilization,Cpu Load 1minute,Flash Utilization and Mgmt Port Status.[AX23AX26S-MIB :: axsChassisStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.3,axsStsLedStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.4,axsMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.7,axsMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.8,axsMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.9,axsCpuLoad1m : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.11,axsFlashTotalSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.12,axsFlashUsedSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.13,axsFlashFreeSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.14,axsMgmtPortStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.27]

Prerequisites

Device must have support for AX23AX26S-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Alaxala AX23AX26S Switch - Performancealaxala_ax23ax26s_switch_ChassisStatusAlaxala AX23AX26S Switch Chassis StatusMonitors the current status of this chassis.[AX23AX26S-MIB :: axsChassisStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.3] Possible values are : 2 : up.
alaxala_ax23ax26s_switch_StsLedStatusAlaxala AX23AX26S Switch STS LED StatusMonitors the state of STS LED of the device.[AX23AX26S-MIB :: axsStsLedStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.4] Possible values are : 1 : green-light-blink,2 : green-light-on,3 : red-light-blink,4 : red-light-on,6 : light-off.
alaxala_ax23ax26s_switch_CpuLoad1minAlaxala AX23AX26S Switch Cpu Load 1minute%Monitors the CPU utilization of one minute.[AX23AX26S-MIB :: axsCpuLoad1m : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.11]
alaxala_ax23ax26s_switch_MgmtPortStatusAlaxala AX23AX26S Switch Mgmt Port StatusMonitors the state of management-port status of the device.[AX23AX26S-MIB :: axsMgmtPortStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.27] Possible values are : -1 : disconnected.
alaxala_ax23ax26s_switch_MemoryUtilizationAlaxala AX23AX26S Switch Memory Utilization%Monitors the Alaxala AX2300S and AX2600S Switch Memory Utilization.[AX23AX26S-MIB :: axsMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.7,axsMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.8,axsMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.9]
alaxala_ax23ax26s_switch_FlashUtilizationAlaxala AX23AX26S Switch Flash Utilization%Monitors the Alaxala AX23AX26S Switch Flash Utilization.[AX23AX26S-MIB :: axsFlashTotalSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.12,axsFlashUsedSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.13,axsFlashFreeSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.14]

Alaxala AX23AX26S Switch Hardware

Description

Monitors the Alaxala AX2300S and AX2600S Switch Fan Status,Module Slot Status,PhysLine Operation Status and Transceiver Status,PhysLineLane Transceiver Tx and Rx Power,Power Connection Status and PowerSupply Status,Temperature Value and State.[AX23AX26S-MIB :: axsModuleSlotStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.7.1.2,axsPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.1.802.42.1.1.3,axsPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.1.802.42.1.1.5,axsPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.1.802.42.2.1.2,axsPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.1.802.42.2.1.3,axsPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.4.1.2,axsPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.4.1.3,axsTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.1.802.41.3.1.3,axsTemperatureState : 1.3.6.1.4.1.21839.2.2.1.802.41.3.1.5,ax2530sFanStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.5.1.2]

Prerequisites

Device must have support for AX23AX26S-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Alaxala AX23AX26S Switch - Fanalaxala_ax23ax26s_switch_FanStatusAlaxala AX23AX26S Switch Fan StatusMonitors the Status of fans.[AX23AX26S-MIB :: axsFanStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.5.1.2] Possible values are : 2 : ok,3 : high-speed,4 : fault,32 : notconnect.
Alaxala AX23AX26S Switch - Modulealaxala_ax23ax26s_switch_ModuleSlotStatusAlaxala AX23AX26S Switch Module Slot StatusMonitors the Alaxala AX2300S and AX2600S Switch Module Slot Status.[AX23AX26S-MIB :: axsModuleSlotStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.7.1.2] Possible values are : 2 : connected,4 : down,32 : disconnected.
Alaxala AX23AX26S Switch - Physical Portalaxala_ax23ax26s_switch_PhysLineOperStatusAlaxala AX23AX26S Switch Physical Port Operation StatusMonitors the operational status of physical port.[AX23AX26S-MIB :: axsPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.1.802.42.1.1.3] 1 : other,2 : active,3 : initialization,4 : down,6 : lock,7 : close,8 : line-fault,9 : test,10 : nothing-configuration,11 : suspend.
alaxala_ax23ax26s_switch_PhysLineTransceiverStatusAlaxala AX23AX26S Switch PhysLine Transceiver StatusMonitors the type and status of replaceable transceiver.[AX23AX26S-MIB :: axsPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.1.802.42.1.1.5] Possible values are : 1 : unchangeable-transceiver,20 : sfp-mounted,21 : sfp-unmounted,22 : unsupported-sfp-mounted,23 : sfp-status-unknown,50 : qsfp-mounted,51 : qsfp-unmounted,52 : unsupported-qsfp-mounted,53 : qsfp-status-unknown.
Alaxala AX23AX26S Switch - Physical Port Lanealaxala_ax23ax26s_switch_PhysLineLaneTransceiverTxPowerAlaxala AX23AX26S Switch PhysLineLane Transceiver Tx PowerdBmMonitors the Alaxala AX2300S and AX2600S Switch PhysLineLane Transceiver Tx Power.[AX23AX26S-MIB :: axsPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.1.802.42.2.1.2]
alaxala_ax23ax26s_switch_PhysLineLaneTransceiverRxPowerAlaxala AX23AX26S Switch PhysLineLane Transceiver Rx PowerdBmMonitors the Alaxala AX2300S and AX2600S Switch PhysLineLane Transceiver Rx Power.[AX23AX26S-MIB :: axsPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.1.802.42.2.1.3]
Alaxala AX23AX26S Switch - Poweralaxala_ax23ax26s_switch_PowerConnectStatusAlaxala AX23AX26S Switch PowerConnect StatusMonitors the current connection status of the power unit.[AX23AX26S-MIB :: axsPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.4.1.2] Possible values are : 2 : connected,32 : disconnected.
alaxala_ax23ax26s_switch_PowerSupplyStatusAlaxala AX23AX26S Switch PowerSupply StatusMonitors the status of power supply.[AX23AX26S-MIB :: axsPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.4.1.3] Possible values are : -1 : disconnected,2 : ok,4 : fault,10 : unused.
Alaxala AX23AX26S Switch - Temperaturealaxala_ax23ax26s_switch_TemperatureStatusValueAlaxala AX23AX26S Switch Temperature Status ValueCelsiusMonitors the current measurement of the testpoint being instrumented.[AX23AX26S-MIB :: axsTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.1.802.41.3.1.3]
alaxala_ax23ax26s_switch_TemperatureStateAlaxala AX23AX26S Switch Temperature StateMonitors the current state of the testpoint being instrumented.[AX23AX26S-MIB :: axsTemperatureState : 1.3.6.1.4.1.21839.2.2.1.802.41.3.1.5] 1 : normal,2 : caution,3 : warning,4 : fatal.
Alaxala AX23AX26S Switch - Stackalaxala_ax23ax26s_switch_AxsStackStatusAlaxala AX23AX26S Switch Stack StatusMonitors the Alaxala AX23AX26S Switch Stack Status.[AX23AX26S-MIB :: axsStackStatus : 1.3.6.1.4.1.21839.2.2.1.400.2.1.1.11] Possible values are : 0 : standalone,1 : init,2 : master,3 : backup.

Alaxala AX23AX26S Switch Stack Statistics

Description

Monitors the Alaxala AX23AX26S Switch Stack Status.[AX23AX26S-MIB :: axsStackStatus : 1.3.6.1.4.1.21839.2.2.1.400.2.1.1.11]

Prerequisites

Device must have support for AX23AX26S-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Alaxala AX23AX26S Switch - Stackalaxala_ax23ax26s_switch_AxsStackStatusAlaxala AX23AX26S Switch Stack StatusMonitors the Alaxala AX23AX26S Switch Stack Status.[AX23AX26S-MIB :: axsStackStatus : 1.3.6.1.4.1.21839.2.2.1.400.2.1.1.11] Possible values are : 0 : standalone,1 : init,2 : master,3 : backup.

Alaxala AX2530S Switch Performance

Description

Monitors the Alaxala AX2530S Switch Performance Statistics like Chassis Status,STS LED Status,Memory Utilization,Cpu Load 1minute and Flash Utilization.[AX2530S :: ax2530sChassisStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.3,ax2530sStsLedStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.4,ax2530sMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.7,ax2530sMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.8,ax2530sMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.9,ax2530sCpuLoad1m : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.11,ax2530sFlashTotalSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.12,ax2530sFlashUsedSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.13,ax2530sFlashFreeSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.14]

Prerequisites

Device must have support for AX2530S mib

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Alaxala AX2530S Switch - Performancealaxala_ax2530s_switch_ChassisStatusAlaxala AX2530S Switch Chassis StatusMonitors the current status of this chassis.[AX2530S :: ax2530sChassisStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.3] Possible values are : 2 : up.
alaxala_ax2530s_switch_StsLedStatusAlaxala AX2530S Switch STS LED StatusMonitors the state of STS LED of the device.[AX2530S :: ax2530sStsLedStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.4] Possible values are : 1 : green-light-blink,2 : green-light-on,3 : red-light-blink,4 : red-light-on,6 : light-off,8 : orange-light-on.
alaxala_ax2530s_switch_CpuLoad1minAlaxala AX2530S Switch Cpu Load 1minute%Monitors the CPU utilization of one minute.[AX2530S :: ax2530sCpuLoad1m : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.11]
alaxala_ax2530s_switch_MemoryUtilizationAlaxala AX2530S Switch Memory Utilization%Monitors the Alaxala AX2530S Switch Memory Utilization.[AX2530S :: ax2530sMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.7,ax2530sMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.8,ax2530sMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.9]
alaxala_ax2530s_switch_FlashUtilizationAlaxala AX2530S Switch Flash Utilization%Monitors the Alaxala AX2530S Switch Flash Utilization.[AX2530S :: ax2530sFlashTotalSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.12,ax2530sFlashUsedSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.13,ax2530sFlashFreeSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.14]

Alaxala AX2530S Switch Hardware

Description

Monitors the Alaxala AX2530S Switch Fan Status,PhysLine Operation Status and Transceiver Status,PhysLineLane Transceiver Tx and Rx Power,Power Connection Status and PowerSupply Status,Temperature Value and State.[AX2530S :: ax2530sFanStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.5.1.2,ax2530sPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.16.2.2.1.1.3,ax2530sPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.16.2.2.1.1.5,ax2530sPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.16.2.2.2.1.2,ax2530sPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.16.2.2.2.1.3,ax2530sPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.4.1.2,ax2530sPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.4.1.3,ax2530sTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.16.2.1.3.1.3,ax2530sTemperatureState : 1.3.6.1.4.1.21839.2.2.16.2.1.3.1.5]

Prerequisites

Device must have support for AX2530S mib

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Alaxala AX2530S Switch - Fanalaxala_ax2530s_switch_FanStatusAlaxala AX2530S Switch Fan StatusMonitors the Alaxala AX2530S Switch Fan Status.[AX2530S :: ax2530sFanStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.5.1.2] Possible values are : 2 : ok,4 : fault,5 : stopping.
Alaxala AX2530S Switch - Physical Portalaxala_ax2530s_switch_PhysLineOperStatusAlaxala AX2530S Switch Physical Port Operation StatusMonitors the operational status of physical port.[AX2530S :: ax2530sPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.16.2.2.1.1.3] Possible values are : 1 : other,2 : active,3 : initialization,4 : down,6 : lock,8 : line-fault,9 : test,20 : inactive .
alaxala_ax2530s_switch_PhysLineTransceiverStatusAlaxala AX2530S Switch PhysLine Transceiver StatusMonitors the type and status of replaceable transceiver.[AX2530S :: ax2530sPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.16.2.2.1.1.5] Possible values are : 1 : unchangeable-transceiver,20 : sfp-mounted,21 : sfp-unmounted,22 : unsupported-sfp-mounted,23 : sfp-status-unknown .
Alaxala AX2530S Switch - Physical Port Lanealaxala_ax2530s_switch_PhysLineLaneTransceiverTxPowerAlaxala AX2530S Switch PhysLineLane Transceiver Tx PowerdBmMonitors the Alaxala AX2530S Switch PhysLineLane Transceiver Tx Power.[AX2530S :: ax2530sPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.16.2.2.2.1.2]
alaxala_ax2530s_switch_PhysLineLaneTransceiverRxPowerAlaxala AX2530S Switch PhysLineLane Transceiver Rx PowerdBmMonitors the Alaxala AX2530S Switch PhysLineLane Transceiver Rx Power.[AX2530S :: ax2530sPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.16.2.2.2.1.3]
Alaxala AX2530S Switch - Poweralaxala_ax2530s_switch_PowerConnectStatusAlaxala AX2530S Switch PowerConnect StatusMonitors the current connection status of the power unit.[AX2530S :: ax2530sPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.4.1.2] Possible values are : 2 : connected,32 : disconnected.
alaxala_ax2530s_switch_PowerSupplyStatusAlaxala AX2530S Switch PowerSupply StatusMonitors the status of power supply.[AX2530S :: ax2530sPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.4.1.3] Possible values are : 2 : ok,4 : fault.
Alaxala AX2530S Switch - Temperaturealaxala_ax2530s_switch_TemperatureStatusValueAlaxala AX2530S Switch Temperature ValueCelsiusMonitors the current measurement of the testpoint being instrumented.[AX2530S :: ax2530sTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.16.2.1.3.1.3]
alaxala_ax2530s_switch_TemperatureStateAlaxala AX2530S Switch Temperature StateMonitors the current state of the testpoint being instrumented.[AX2530S :: ax2530sTemperatureState : 1.3.6.1.4.1.21839.2.2.16.2.1.3.1.5] Possible values are : 1 : normal,2 : caution,4 : fatal.

Alaxala AX3660S Switch Performance

Description

Monitors the Alaxala AX3660S Switch Performance Statistics like Chassis Status,STS LED Status,Memory Utilization,Cpu Load 1minute,Flash Utilization and Mgmt Port Status.[AX3660S :: ax3660sChassisStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.3,ax3660sStsLedStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.4,ax3660sMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.7,ax3660sMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.8,ax3660sMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.9,ax3660sCpuLoad1m : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.11,ax3660sFlashTotalSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.12,ax3660sFlashUsedSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.13,ax3660sFlashFreeSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.14,ax3660sMgmtPortStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.27]

Prerequisites

Device must have support for AX3660S mib

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Alaxala AX3660S Switch - Performancealaxala_ax3660s_switch_ChassisStatusAlaxala AX3660S Switch Chassis StatusMonitors the current status of this chassis.[AX3660S :: ax3660sChassisStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.3] Possible values are : 2 : up.
alaxala_ax3660s_switch_StsLedStatusAlaxala AX3660S Switch STS LED StatusMonitors the state of STS LED of the device.[AX3660S :: ax3660sStsLedStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.4] Possible values are : 1 : green-light-blink,2 : green-light-on,3 : red-light-blink,4 : red-light-on,6 : light-off.
alaxala_ax3660s_switch_CpuLoad1minAlaxala AX3660S Switch Cpu Load 1minute%Monitors the CPU utilization of one minute.[AX3660S :: ax3660sCpuLoad1m : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.11]
alaxala_ax3660s_switch_MgmtPortStatusAlaxala AX3660S Switch Mgmt Port StatusMonitors the state of management-port status of the device.[AX3660S :: ax3660sMgmtPortStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.27] Possible values are : -1 : disconnected,2 : active,4 : down,6 : disabled,7 : maintenance,9 : line-test,10 : unused.
alaxala_ax3660s_switch_MemoryUtilizationAlaxala AX3660S Switch Memory Utilization%Monitors the Alaxala AX3660S Switch Memory Utilization.[AX3660S :: ax3660sMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.7,ax3660sMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.8,ax3660sMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.9]
alaxala_ax3660s_switch_FlashUtilizationAlaxala AX3660S Switch Flash Utilization%Monitors the Alaxala AX3660S Switch Flash Utilization.[AX3660S :: ax3660sFlashTotalSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.12,ax3660sFlashUsedSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.13,ax3660sFlashFreeSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.14]

Alaxala AX3660S Switch Hardware

Description

Monitors the Alaxala AX3660S Switch Fan Status,Module Slot Status,PhysLine Operation Status and Transceiver Status,PhysLineLane Transceiver Tx and Rx Power,Power Connection Status and PowerSupply Status,Temperature Value and State.[AX3660S :: ax3660sFanStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.5.1.2,ax3660sModuleSlotStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.7.1.2,ax3660sPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.24.2.5.1.1.3,ax3660sPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.24.2.5.1.1.5,ax3660sPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.24.2.5.2.1.2,ax3660sPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.24.2.5.2.1.3,ax3660sPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.4.1.2,ax3660sPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.4.1.3,ax3660sTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.24.2.1.3.1.3,ax3660sTemperatureState : 1.3.6.1.4.1.21839.2.2.24.2.1.3.1.5]

Prerequisites

Device must have support for AX3660S mib

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
Alaxala AX3660S Switch - Fanalaxala_ax3660s_switch_FanStatusAlaxala AX3660S Switch Fan StatusMonitors the Status of fans.[AX3660S :: ax3660sFanStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.5.1.2] Possible values are : 2 : ok,3 : high-speed,4 : fault,32 : notconnect.
Alaxala AX3660S Switch - Modulealaxala_ax3660s_switch_ModuleSlotStatusAlaxala AX3660S Switch Module Slot StatusMonitors the Alaxala AX3660S Switch Module Slot Status.[AX3660S :: ax3660sModuleSlotStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.7.1.2] Possible values are : 2 : ok,4 : down,32 : disconnected.
Alaxala AX3660S Switch - Physical Portalaxala_ax3660s_switch_PhysLineOperStatusAlaxala AX3660S Switch Physical Port Operation StatusMonitors the operational status of physical port.[AX3660S :: ax3660sPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.24.2.5.1.1.3] Possible values are : 1 : other,2 : active,3 : initialization,4 : down,6 : lock,7 : close,8 : line-fault,9 : test,10 : nothing-configuration,11 : suspend.
alaxala_ax3660s_switch_PhysLineTransceiverStatusAlaxala AX3660S Switch PhysLine Transceiver StatusMonitors the type and status of replaceable transceiver.[AX3660S :: ax3660sPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.24.2.5.1.1.5] Possible values are : 1 : unchangeable-transceiver,20 : sfp-mounted,21 : sfp-unmounted,22 : unsupported-sfp-mounted,23 : sfp-status-unknown,50 : qsfp-mounted,51 : qsfp-unmounted,52 : unsupported-qsfp-mounted,53 : qsfp-status-unknown.
Alaxala AX3660S Switch - Physical Port Lanealaxala_ax3660s_switch_PhysLineLaneTransceiverTxPowerAlaxala AX3660S Switch PhysLineLane Transceiver Tx PowerdBmMonitors the Alaxala AX3660S Switch PhysLineLane Transceiver Tx Power.[AX3660S :: ax3660sPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.24.2.5.2.1.2]
alaxala_ax3660s_switch_PhysLineLaneTransceiverRxPowerAlaxala AX3660S Switch PhysLineLane Transceiver Rx PowerdBmMonitors the Alaxala AX3660S Switch PhysLineLane Transceiver Rx Power.[AX3660S :: ax3660sPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.24.2.5.2.1.3]
Alaxala AX3660S Switch - Poweralaxala_ax3660s_switch_PowerConnectStatusAlaxala AX3660S Switch PowerConnect StatusMonitors the current connection status of the power unit.[AX3660S :: ax3660sPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.4.1.2] Possible values are : 2 : connected,32 : disconnected.
alaxala_ax3660s_switch_PowerSupplyStatusAlaxala AX3660S Switch PowerSupply StatusMonitors the status of power supply.[AX3660S :: ax3660sPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.4.1.3] Possible values are : 2 : ok,4 : fault,-1 : disconnected.
Alaxala AX3660S Switch - Temperaturealaxala_ax3660s_switch_TemperatureStatusValueAlaxala AX3660S Switch Temperature Status ValueCelsiusMonitors the current measurement of the testpoint being instrumented.[AX3660S :: ax3660sTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.24.2.1.3.1.3]
alaxala_ax3660s_switch_TemperatureStateAlaxala AX3660S Switch Temperature StateMonitors the current state of the testpoint being instrumented.[AX3660S :: ax3660sTemperatureState : 1.3.6.1.4.1.21839.2.2.24.2.1.3.1.5] Possible values are : 1 : normal,2 : caution,3 : warning,4 : fatal.