Alaxala AX23AX26S Switch Performance
Description
Monitors the Alaxala AX2300S and AX2600S Switch Performance Statistics like Chassis Status,STS LED Status,Memory Utilization,Cpu Load 1minute,Flash Utilization and Mgmt Port Status.[AX23AX26S-MIB :: axsChassisStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.3,axsStsLedStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.4,axsMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.7,axsMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.8,axsMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.9,axsCpuLoad1m : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.11,axsFlashTotalSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.12,axsFlashUsedSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.13,axsFlashFreeSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.14,axsMgmtPortStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.27]
Prerequisites
Device must have support for AX23AX26S-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Alaxala AX23AX26S Switch - Performance | alaxala_ax23ax26s_switch_ChassisStatus | Alaxala AX23AX26S Switch Chassis Status | Monitors the current status of this chassis.[AX23AX26S-MIB :: axsChassisStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.3] Possible values are : 2 : up. | |
alaxala_ax23ax26s_switch_StsLedStatus | Alaxala AX23AX26S Switch STS LED Status | Monitors the state of STS LED of the device.[AX23AX26S-MIB :: axsStsLedStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.4] Possible values are : 1 : green-light-blink,2 : green-light-on,3 : red-light-blink,4 : red-light-on,6 : light-off. | ||
alaxala_ax23ax26s_switch_CpuLoad1min | Alaxala AX23AX26S Switch Cpu Load 1minute | % | Monitors the CPU utilization of one minute.[AX23AX26S-MIB :: axsCpuLoad1m : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.11] | |
alaxala_ax23ax26s_switch_MgmtPortStatus | Alaxala AX23AX26S Switch Mgmt Port Status | Monitors the state of management-port status of the device.[AX23AX26S-MIB :: axsMgmtPortStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.27] Possible values are : -1 : disconnected. | ||
alaxala_ax23ax26s_switch_MemoryUtilization | Alaxala AX23AX26S Switch Memory Utilization | % | Monitors the Alaxala AX2300S and AX2600S Switch Memory Utilization.[AX23AX26S-MIB :: axsMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.7,axsMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.8,axsMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.9] | |
alaxala_ax23ax26s_switch_FlashUtilization | Alaxala AX23AX26S Switch Flash Utilization | % | Monitors the Alaxala AX23AX26S Switch Flash Utilization.[AX23AX26S-MIB :: axsFlashTotalSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.12,axsFlashUsedSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.13,axsFlashFreeSize : 1.3.6.1.4.1.21839.2.2.1.802.41.2.1.14] |
Alaxala AX23AX26S Switch Hardware
Description
Monitors the Alaxala AX2300S and AX2600S Switch Fan Status,Module Slot Status,PhysLine Operation Status and Transceiver Status,PhysLineLane Transceiver Tx and Rx Power,Power Connection Status and PowerSupply Status,Temperature Value and State.[AX23AX26S-MIB :: axsModuleSlotStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.7.1.2,axsPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.1.802.42.1.1.3,axsPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.1.802.42.1.1.5,axsPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.1.802.42.2.1.2,axsPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.1.802.42.2.1.3,axsPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.4.1.2,axsPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.4.1.3,axsTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.1.802.41.3.1.3,axsTemperatureState : 1.3.6.1.4.1.21839.2.2.1.802.41.3.1.5,ax2530sFanStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.5.1.2]
Prerequisites
Device must have support for AX23AX26S-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Alaxala AX23AX26S Switch - Fan | alaxala_ax23ax26s_switch_FanStatus | Alaxala AX23AX26S Switch Fan Status | Monitors the Status of fans.[AX23AX26S-MIB :: axsFanStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.5.1.2] Possible values are : 2 : ok,3 : high-speed,4 : fault,32 : notconnect. | |
Alaxala AX23AX26S Switch - Module | alaxala_ax23ax26s_switch_ModuleSlotStatus | Alaxala AX23AX26S Switch Module Slot Status | Monitors the Alaxala AX2300S and AX2600S Switch Module Slot Status.[AX23AX26S-MIB :: axsModuleSlotStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.7.1.2] Possible values are : 2 : connected,4 : down,32 : disconnected. | |
Alaxala AX23AX26S Switch - Physical Port | alaxala_ax23ax26s_switch_PhysLineOperStatus | Alaxala AX23AX26S Switch Physical Port Operation Status | Monitors the operational status of physical port.[AX23AX26S-MIB :: axsPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.1.802.42.1.1.3] 1 : other,2 : active,3 : initialization,4 : down,6 : lock,7 : close,8 : line-fault,9 : test,10 : nothing-configuration,11 : suspend. | |
alaxala_ax23ax26s_switch_PhysLineTransceiverStatus | Alaxala AX23AX26S Switch PhysLine Transceiver Status | Monitors the type and status of replaceable transceiver.[AX23AX26S-MIB :: axsPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.1.802.42.1.1.5] Possible values are : 1 : unchangeable-transceiver,20 : sfp-mounted,21 : sfp-unmounted,22 : unsupported-sfp-mounted,23 : sfp-status-unknown,50 : qsfp-mounted,51 : qsfp-unmounted,52 : unsupported-qsfp-mounted,53 : qsfp-status-unknown. | ||
Alaxala AX23AX26S Switch - Physical Port Lane | alaxala_ax23ax26s_switch_PhysLineLaneTransceiverTxPower | Alaxala AX23AX26S Switch PhysLineLane Transceiver Tx Power | dBm | Monitors the Alaxala AX2300S and AX2600S Switch PhysLineLane Transceiver Tx Power.[AX23AX26S-MIB :: axsPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.1.802.42.2.1.2] |
alaxala_ax23ax26s_switch_PhysLineLaneTransceiverRxPower | Alaxala AX23AX26S Switch PhysLineLane Transceiver Rx Power | dBm | Monitors the Alaxala AX2300S and AX2600S Switch PhysLineLane Transceiver Rx Power.[AX23AX26S-MIB :: axsPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.1.802.42.2.1.3] | |
Alaxala AX23AX26S Switch - Power | alaxala_ax23ax26s_switch_PowerConnectStatus | Alaxala AX23AX26S Switch PowerConnect Status | Monitors the current connection status of the power unit.[AX23AX26S-MIB :: axsPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.4.1.2] Possible values are : 2 : connected,32 : disconnected. | |
alaxala_ax23ax26s_switch_PowerSupplyStatus | Alaxala AX23AX26S Switch PowerSupply Status | Monitors the status of power supply.[AX23AX26S-MIB :: axsPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.1.802.41.4.1.3] Possible values are : -1 : disconnected,2 : ok,4 : fault,10 : unused. | ||
Alaxala AX23AX26S Switch - Temperature | alaxala_ax23ax26s_switch_TemperatureStatusValue | Alaxala AX23AX26S Switch Temperature Status Value | Celsius | Monitors the current measurement of the testpoint being instrumented.[AX23AX26S-MIB :: axsTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.1.802.41.3.1.3] |
alaxala_ax23ax26s_switch_TemperatureState | Alaxala AX23AX26S Switch Temperature State | Monitors the current state of the testpoint being instrumented.[AX23AX26S-MIB :: axsTemperatureState : 1.3.6.1.4.1.21839.2.2.1.802.41.3.1.5] 1 : normal,2 : caution,3 : warning,4 : fatal. | ||
Alaxala AX23AX26S Switch - Stack | alaxala_ax23ax26s_switch_AxsStackStatus | Alaxala AX23AX26S Switch Stack Status | Monitors the Alaxala AX23AX26S Switch Stack Status.[AX23AX26S-MIB :: axsStackStatus : 1.3.6.1.4.1.21839.2.2.1.400.2.1.1.11] Possible values are : 0 : standalone,1 : init,2 : master,3 : backup. |
Alaxala AX23AX26S Switch Stack Statistics
Description
Monitors the Alaxala AX23AX26S Switch Stack Status.[AX23AX26S-MIB :: axsStackStatus : 1.3.6.1.4.1.21839.2.2.1.400.2.1.1.11]
Prerequisites
Device must have support for AX23AX26S-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Alaxala AX23AX26S Switch - Stack | alaxala_ax23ax26s_switch_AxsStackStatus | Alaxala AX23AX26S Switch Stack Status | Monitors the Alaxala AX23AX26S Switch Stack Status.[AX23AX26S-MIB :: axsStackStatus : 1.3.6.1.4.1.21839.2.2.1.400.2.1.1.11] Possible values are : 0 : standalone,1 : init,2 : master,3 : backup. |
Alaxala AX2530S Switch Performance
Description
Monitors the Alaxala AX2530S Switch Performance Statistics like Chassis Status,STS LED Status,Memory Utilization,Cpu Load 1minute and Flash Utilization.[AX2530S :: ax2530sChassisStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.3,ax2530sStsLedStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.4,ax2530sMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.7,ax2530sMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.8,ax2530sMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.9,ax2530sCpuLoad1m : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.11,ax2530sFlashTotalSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.12,ax2530sFlashUsedSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.13,ax2530sFlashFreeSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.14]
Prerequisites
Device must have support for AX2530S mib
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Alaxala AX2530S Switch - Performance | alaxala_ax2530s_switch_ChassisStatus | Alaxala AX2530S Switch Chassis Status | Monitors the current status of this chassis.[AX2530S :: ax2530sChassisStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.3] Possible values are : 2 : up. | |
alaxala_ax2530s_switch_StsLedStatus | Alaxala AX2530S Switch STS LED Status | Monitors the state of STS LED of the device.[AX2530S :: ax2530sStsLedStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.4] Possible values are : 1 : green-light-blink,2 : green-light-on,3 : red-light-blink,4 : red-light-on,6 : light-off,8 : orange-light-on. | ||
alaxala_ax2530s_switch_CpuLoad1min | Alaxala AX2530S Switch Cpu Load 1minute | % | Monitors the CPU utilization of one minute.[AX2530S :: ax2530sCpuLoad1m : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.11] | |
alaxala_ax2530s_switch_MemoryUtilization | Alaxala AX2530S Switch Memory Utilization | % | Monitors the Alaxala AX2530S Switch Memory Utilization.[AX2530S :: ax2530sMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.7,ax2530sMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.8,ax2530sMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.9] | |
alaxala_ax2530s_switch_FlashUtilization | Alaxala AX2530S Switch Flash Utilization | % | Monitors the Alaxala AX2530S Switch Flash Utilization.[AX2530S :: ax2530sFlashTotalSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.12,ax2530sFlashUsedSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.13,ax2530sFlashFreeSize : 1.3.6.1.4.1.21839.2.2.16.2.1.2.1.14] |
Alaxala AX2530S Switch Hardware
Description
Monitors the Alaxala AX2530S Switch Fan Status,PhysLine Operation Status and Transceiver Status,PhysLineLane Transceiver Tx and Rx Power,Power Connection Status and PowerSupply Status,Temperature Value and State.[AX2530S :: ax2530sFanStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.5.1.2,ax2530sPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.16.2.2.1.1.3,ax2530sPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.16.2.2.1.1.5,ax2530sPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.16.2.2.2.1.2,ax2530sPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.16.2.2.2.1.3,ax2530sPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.4.1.2,ax2530sPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.4.1.3,ax2530sTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.16.2.1.3.1.3,ax2530sTemperatureState : 1.3.6.1.4.1.21839.2.2.16.2.1.3.1.5]
Prerequisites
Device must have support for AX2530S mib
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Alaxala AX2530S Switch - Fan | alaxala_ax2530s_switch_FanStatus | Alaxala AX2530S Switch Fan Status | Monitors the Alaxala AX2530S Switch Fan Status.[AX2530S :: ax2530sFanStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.5.1.2] Possible values are : 2 : ok,4 : fault,5 : stopping. | |
Alaxala AX2530S Switch - Physical Port | alaxala_ax2530s_switch_PhysLineOperStatus | Alaxala AX2530S Switch Physical Port Operation Status | Monitors the operational status of physical port.[AX2530S :: ax2530sPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.16.2.2.1.1.3] Possible values are : 1 : other,2 : active,3 : initialization,4 : down,6 : lock,8 : line-fault,9 : test,20 : inactive . | |
alaxala_ax2530s_switch_PhysLineTransceiverStatus | Alaxala AX2530S Switch PhysLine Transceiver Status | Monitors the type and status of replaceable transceiver.[AX2530S :: ax2530sPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.16.2.2.1.1.5] Possible values are : 1 : unchangeable-transceiver,20 : sfp-mounted,21 : sfp-unmounted,22 : unsupported-sfp-mounted,23 : sfp-status-unknown . | ||
Alaxala AX2530S Switch - Physical Port Lane | alaxala_ax2530s_switch_PhysLineLaneTransceiverTxPower | Alaxala AX2530S Switch PhysLineLane Transceiver Tx Power | dBm | Monitors the Alaxala AX2530S Switch PhysLineLane Transceiver Tx Power.[AX2530S :: ax2530sPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.16.2.2.2.1.2] |
alaxala_ax2530s_switch_PhysLineLaneTransceiverRxPower | Alaxala AX2530S Switch PhysLineLane Transceiver Rx Power | dBm | Monitors the Alaxala AX2530S Switch PhysLineLane Transceiver Rx Power.[AX2530S :: ax2530sPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.16.2.2.2.1.3] | |
Alaxala AX2530S Switch - Power | alaxala_ax2530s_switch_PowerConnectStatus | Alaxala AX2530S Switch PowerConnect Status | Monitors the current connection status of the power unit.[AX2530S :: ax2530sPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.4.1.2] Possible values are : 2 : connected,32 : disconnected. | |
alaxala_ax2530s_switch_PowerSupplyStatus | Alaxala AX2530S Switch PowerSupply Status | Monitors the status of power supply.[AX2530S :: ax2530sPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.16.2.1.4.1.3] Possible values are : 2 : ok,4 : fault. | ||
Alaxala AX2530S Switch - Temperature | alaxala_ax2530s_switch_TemperatureStatusValue | Alaxala AX2530S Switch Temperature Value | Celsius | Monitors the current measurement of the testpoint being instrumented.[AX2530S :: ax2530sTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.16.2.1.3.1.3] |
alaxala_ax2530s_switch_TemperatureState | Alaxala AX2530S Switch Temperature State | Monitors the current state of the testpoint being instrumented.[AX2530S :: ax2530sTemperatureState : 1.3.6.1.4.1.21839.2.2.16.2.1.3.1.5] Possible values are : 1 : normal,2 : caution,4 : fatal. |
Alaxala AX3660S Switch Performance
Description
Monitors the Alaxala AX3660S Switch Performance Statistics like Chassis Status,STS LED Status,Memory Utilization,Cpu Load 1minute,Flash Utilization and Mgmt Port Status.[AX3660S :: ax3660sChassisStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.3,ax3660sStsLedStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.4,ax3660sMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.7,ax3660sMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.8,ax3660sMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.9,ax3660sCpuLoad1m : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.11,ax3660sFlashTotalSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.12,ax3660sFlashUsedSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.13,ax3660sFlashFreeSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.14,ax3660sMgmtPortStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.27]
Prerequisites
Device must have support for AX3660S mib
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Alaxala AX3660S Switch - Performance | alaxala_ax3660s_switch_ChassisStatus | Alaxala AX3660S Switch Chassis Status | Monitors the current status of this chassis.[AX3660S :: ax3660sChassisStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.3] Possible values are : 2 : up. | |
alaxala_ax3660s_switch_StsLedStatus | Alaxala AX3660S Switch STS LED Status | Monitors the state of STS LED of the device.[AX3660S :: ax3660sStsLedStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.4] Possible values are : 1 : green-light-blink,2 : green-light-on,3 : red-light-blink,4 : red-light-on,6 : light-off. | ||
alaxala_ax3660s_switch_CpuLoad1min | Alaxala AX3660S Switch Cpu Load 1minute | % | Monitors the CPU utilization of one minute.[AX3660S :: ax3660sCpuLoad1m : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.11] | |
alaxala_ax3660s_switch_MgmtPortStatus | Alaxala AX3660S Switch Mgmt Port Status | Monitors the state of management-port status of the device.[AX3660S :: ax3660sMgmtPortStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.27] Possible values are : -1 : disconnected,2 : active,4 : down,6 : disabled,7 : maintenance,9 : line-test,10 : unused. | ||
alaxala_ax3660s_switch_MemoryUtilization | Alaxala AX3660S Switch Memory Utilization | % | Monitors the Alaxala AX3660S Switch Memory Utilization.[AX3660S :: ax3660sMemoryTotalSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.7,ax3660sMemoryUsedSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.8,ax3660sMemoryFreeSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.9] | |
alaxala_ax3660s_switch_FlashUtilization | Alaxala AX3660S Switch Flash Utilization | % | Monitors the Alaxala AX3660S Switch Flash Utilization.[AX3660S :: ax3660sFlashTotalSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.12,ax3660sFlashUsedSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.13,ax3660sFlashFreeSize : 1.3.6.1.4.1.21839.2.2.24.2.1.2.1.14] |
Alaxala AX3660S Switch Hardware
Description
Monitors the Alaxala AX3660S Switch Fan Status,Module Slot Status,PhysLine Operation Status and Transceiver Status,PhysLineLane Transceiver Tx and Rx Power,Power Connection Status and PowerSupply Status,Temperature Value and State.[AX3660S :: ax3660sFanStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.5.1.2,ax3660sModuleSlotStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.7.1.2,ax3660sPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.24.2.5.1.1.3,ax3660sPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.24.2.5.1.1.5,ax3660sPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.24.2.5.2.1.2,ax3660sPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.24.2.5.2.1.3,ax3660sPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.4.1.2,ax3660sPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.4.1.3,ax3660sTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.24.2.1.3.1.3,ax3660sTemperatureState : 1.3.6.1.4.1.21839.2.2.24.2.1.3.1.5]
Prerequisites
Device must have support for AX3660S mib
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Alaxala AX3660S Switch - Fan | alaxala_ax3660s_switch_FanStatus | Alaxala AX3660S Switch Fan Status | Monitors the Status of fans.[AX3660S :: ax3660sFanStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.5.1.2] Possible values are : 2 : ok,3 : high-speed,4 : fault,32 : notconnect. | |
Alaxala AX3660S Switch - Module | alaxala_ax3660s_switch_ModuleSlotStatus | Alaxala AX3660S Switch Module Slot Status | Monitors the Alaxala AX3660S Switch Module Slot Status.[AX3660S :: ax3660sModuleSlotStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.7.1.2] Possible values are : 2 : ok,4 : down,32 : disconnected. | |
Alaxala AX3660S Switch - Physical Port | alaxala_ax3660s_switch_PhysLineOperStatus | Alaxala AX3660S Switch Physical Port Operation Status | Monitors the operational status of physical port.[AX3660S :: ax3660sPhysLineOperStatus : 1.3.6.1.4.1.21839.2.2.24.2.5.1.1.3] Possible values are : 1 : other,2 : active,3 : initialization,4 : down,6 : lock,7 : close,8 : line-fault,9 : test,10 : nothing-configuration,11 : suspend. | |
alaxala_ax3660s_switch_PhysLineTransceiverStatus | Alaxala AX3660S Switch PhysLine Transceiver Status | Monitors the type and status of replaceable transceiver.[AX3660S :: ax3660sPhysLineTransceiverStatus : 1.3.6.1.4.1.21839.2.2.24.2.5.1.1.5] Possible values are : 1 : unchangeable-transceiver,20 : sfp-mounted,21 : sfp-unmounted,22 : unsupported-sfp-mounted,23 : sfp-status-unknown,50 : qsfp-mounted,51 : qsfp-unmounted,52 : unsupported-qsfp-mounted,53 : qsfp-status-unknown. | ||
Alaxala AX3660S Switch - Physical Port Lane | alaxala_ax3660s_switch_PhysLineLaneTransceiverTxPower | Alaxala AX3660S Switch PhysLineLane Transceiver Tx Power | dBm | Monitors the Alaxala AX3660S Switch PhysLineLane Transceiver Tx Power.[AX3660S :: ax3660sPhysLineLaneTransceiverTxPower : 1.3.6.1.4.1.21839.2.2.24.2.5.2.1.2] |
alaxala_ax3660s_switch_PhysLineLaneTransceiverRxPower | Alaxala AX3660S Switch PhysLineLane Transceiver Rx Power | dBm | Monitors the Alaxala AX3660S Switch PhysLineLane Transceiver Rx Power.[AX3660S :: ax3660sPhysLineLaneTransceiverRxPower : 1.3.6.1.4.1.21839.2.2.24.2.5.2.1.3] | |
Alaxala AX3660S Switch - Power | alaxala_ax3660s_switch_PowerConnectStatus | Alaxala AX3660S Switch PowerConnect Status | Monitors the current connection status of the power unit.[AX3660S :: ax3660sPowerConnectStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.4.1.2] Possible values are : 2 : connected,32 : disconnected. | |
alaxala_ax3660s_switch_PowerSupplyStatus | Alaxala AX3660S Switch PowerSupply Status | Monitors the status of power supply.[AX3660S :: ax3660sPowerSupplyStatus : 1.3.6.1.4.1.21839.2.2.24.2.1.4.1.3] Possible values are : 2 : ok,4 : fault,-1 : disconnected. | ||
Alaxala AX3660S Switch - Temperature | alaxala_ax3660s_switch_TemperatureStatusValue | Alaxala AX3660S Switch Temperature Status Value | Celsius | Monitors the current measurement of the testpoint being instrumented.[AX3660S :: ax3660sTemperatureStatusValue : 1.3.6.1.4.1.21839.2.2.24.2.1.3.1.3] |
alaxala_ax3660s_switch_TemperatureState | Alaxala AX3660S Switch Temperature State | Monitors the current state of the testpoint being instrumented.[AX3660S :: ax3660sTemperatureState : 1.3.6.1.4.1.21839.2.2.24.2.1.3.1.5] Possible values are : 1 : normal,2 : caution,3 : warning,4 : fatal. |