ADVA Ensemble Virtual Edge - Performance

Description

Monitors the ADVA Ensemble Virtual Edge Performance Statistics like CPU Load Average In 5 Minutes, Cpu Utilization and Memory Usage. Validated on Model:advaCots, SysObjectOID::1.3.6.1.4.1.7950.1.1.38.[ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCpuLoadAverage5Min : 1.3.6.1.4.1.7950.3.11.1.2.5.1.7, advaENSCPUUtilization : 1.3.6.1.4.1.7950.3.11.1.2.9.1.10 , advaENSMemoryUsage : 1.3.6.1.4.1.7950.3.11.1.2.9.1.3 ,advaENSFileSystemUsed : 1.3.6.1.4.1.7950.3.11.1.2.8.1.4 , advaENSFileSystemAvailable : 1.3.6.1.4.1.7950.3.11.1.2.8.1.5 , advaENSFileSystemUse : 1.3.6.1.4.1.7950.3.11.1.2.8.1.6]

Prerequisites

Device must have support for ADVA-ENS-SYSTEM-INVENTORY-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
ADVA Ensemble Virtual Edge - CPU LoadadvaENS_VirtualEdge_CpuLoadAverage5MinAdvaENS Virtual Edge Cpu Load Average 5MinutesMonitors the AdvaENS CPU Load Average in the last 5 minutes period. [ ADVA-ENS-SYSTEM-INVENTORY-MIB -MIB :: advaENSCpuLoadAverage5Min : 1.3.6.1.4.1.7950.3.11.1.2.5.1.7 ]
advaENS_VirtualEdge_PhysicalCPUsAdvaENS Virtual Edge Physical CPUsMonitors the AdvaENS Virtual Edge Number of CPUs. [ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCpuPhysicalCPUs : 1.3.6.1.4.1.7950.3.11.1.2.5.1.10]
advaENS_VirtualEdge_CpuCoreThreadsAdvaENS VirtualEdge Cpu Core ThreadsThreadsMonitors the AdvaENS VirtualEdge Cpu Core Threadsif hyper threading is enabled. Possible Values are 1: true ; 2: false [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCpuHyperThreading : 1.3.6.1.4.1.7950.3.11.1.2.5.1.9 ].
ADVA Ensemble Virtual Edge - CPU UtilizationadvaENS_VirtualEdge_CpuUtilizationAdvaENS Virtual Edge Cpu Utilization%Monitors theAdva ENS Virtual Edge CPU Utilization. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCPUUtilization : 1.3.6.1.4.1.7950.3.11.1.2.9.1.10 ]
ADVA Ensemble Virtual Edge - File SystemadvaENS_VirtualEdge_FileSystemUtilizationAdvaENS Virtual Edge File System Utilization%Monitors the AdvaENS Virtual Edge File System Utilization. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemUse : 1.3.6.1.4.1.7950.3.11.1.2.8.1.6 ]
advaENS_VirtualEdge_FileSystemUsedAdvaENS Virtual Edge File System UsedMBMonitors the AdvaENS Virtual Edge File System Used. [ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemUsed : 1.3.6.1.4.1.7950.3.11.1.2.8.1.4 ]
advaENS_VirtualEdge_FileSystemAvailableAdvaENS Virtual Edge File System AvailableMBMonitors the AdvaENS Virtual Edge File System Available.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemAvailable : 1.3.6.1.4.1.7950.3.11.1.2.8.1.5 ]
ADVA Ensemble Virtual Edge - Memory UsageadvaENS_VirtualEdge_MemoryMgmtUsageAdvaENS Virtual Edge Memory Mgmt Usage%Monitors AdvaENS Virtual Edge Percent of Memory Mgmt Usage.[ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSMemoryMgmtUsage : 1.3.6.1.4.1.7950.3.11.1.2.6.1.7 ]
advaENS_VirtualEdge_MemoryMgmtAdvaENS Virtual Edge Memory for MgmtKBMonitors the AdvaENS Virtual Edge Memory for Mgmt in KB [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSMemoryMgmt : 1.3.6.1.4.1.7950.3.11.1.2.6.1.4 ]

ADVA Ensemble Virtual Edge - Hardware

Description

Monitors the ADVA Ensemble Virtual Edge Hardware Metrics like Current Temperature, Temperature Status, Current Voltage, Voltage Status, Current Tx Power, Tx Power Status, Current Rx Power, Rx Power Status. Validated on Model:advaCots, SysObjectOID::1.3.6.1.4.1.7950.1.1.38.[ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.12, advaENSSFPTempStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.13, advaENSSFPVoltageCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.16 , advaENSSFPVoltageStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.17, advaENSSFPTxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.24 , advaENSSFPTxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.25 , advaENSSFPRxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.28 , advaENSSFPRxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.29 ]

Prerequisites

Device must have support for ADVA-ENS-SYSTEM-INVENTORY-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
ADVA Ensemble Virtual Edge - HardwareadvaENS_VirtualEdge_SFPTempCurrentAdvaENS Virtual Edge SFP Temperature CurrentCelsiusMonitors the AdvaENS SFP Virtual Edge Temperature Current. [ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.12]
advaENS_VirtualEdge_SFPTempStatusAdvaENS Virtual Edge SFP Temperature StatusMonitors the AdvaENS VirtualEdge SFP Temperature Status. Alert will be generated when SFP Temperature Status is "NOT OK". [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.13 ]
advaENS_VirtualEdge_SFPVoltageCurrentAdvaENS Virtual Edge SFP Voltage CurrentvMonitors the AdvaENS Virtual Edge SFP Voltage Current Current. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPVoltageCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.16 ]
advaENS_VirtualEdge_SFPVoltageStatusAdvaENS Virtual Edge SFP Voltage StatusMonitors the AdvaENS Virtual Edge SFP Voltage Status. Alert will be generated when SFP Voltage Status is "NOT OK". [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPVoltageStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.17 ]
advaENS_VirtualEdge_SFPTxPowerCurrentAdvaENS Virtual Edge SFP Tx Power CurrentdBmMonitors the AdvaENS Virtual Edge SFP Tx Power Current. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.24 ]
advaENS_VirtualEdge_SFPTxPowerStatusAdvaENS Virtual Edge SFP Tx Power StatusMonitors the AdvaENS VirtualEdge SFP Tx Power Status. Alert will be generated when SFP Tx Power Status is "NOT OK". [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.25 ]
advaENS_VirtualEdge_SFPRxPowerCurrentAdvaENS Virtual Edge SFP Rx Power CurrentdBmMonitors the AdvaENS VirtualEdge SFP Rx Power Current. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPRxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.28 ]
advaENS_VirtualEdge_SFPRxPowerStatusAdvaENS Virtual Edge SFP Rx Power StatusMonitors the AdvaENS Virtual Edge SFP Rx Power Status. Alert will be generated when SFP Rx Power Status. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPRxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.29 ]

ADVA Ensemble Virtual Edge - Vnf

Description

Monitors the ADVA Ensemble Virtual Edge Vnf Metrics like Operational Status, Vnf State, Memory Usage and Vnf Port Operational Status. Validated on Model:advaCots, SysObjectOID::1.3.6.1.4.1.7950.1.1.38.[ ADVA-ENS-VNF-MIB :: advaENSVnfStateOper : 1.3.6.1.4.1.7950.3.11.8.1.3.1.12 , advaENSVnfState : 1.3.6.1.4.1.7950.3.11.8.1.3.1.3 , advaENSVnfStateMemorUsage : 1.3.6.1.4.1.7950.3.11.8.1.3.1.13, advaENSVnfPortStateOper : 1.3.6.1.4.1.7950.3.11.8.1.5.1.9 ]

Prerequisites

Device must have support for ADVA-ENS-VNF-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
ADVA Ensemble Virtual Edge - VnfadvaENS_VirtualEdge_VnfStateAdvaENS Virtual Edge Vnf StateMonitors the AdvaENS Virtual Edge Vnf State. Possible values are 1: shutdown, 2: running, 3: crashed, 4: failed, 5: paused, 6: unknown. [ ADVA-ENS-VNF-MIB :: advaENSVnfState : 1.3.6.1.4.1.7950.3.11.8.1.3.1.3 ]
advaENS_VirtualEdge_VnfStateOperAdvaENS Virtual Edge Vnf Operational StatusMonitors the AdvaENS Virtual Edge Vnf Operational Status. [ ADVA-ENS-VNF-MIB :: advaENSVnfStateOper : 1.3.6.1.4.1.7950.3.11.8.1.3.1.12 ]
advaENS_VirtualEdge_VnfStateMemorUsageAdvaENS Virtual Edge Vnf State Memor Usage%Monitors the AdvaENS Virtual Edge Vnf State Memor Usage. [ ADVA-ENS-VNF-MIB :: advaENSVnfStateMemorUsage : 1.3.6.1.4.1.7950.3.11.8.1.3.1.13 ]
ADVA Ensemble Virtual Edge - Vnf Port StateadvaENS_VirtualEdge_VnfPortStateOperAdvaENS Virtual Edge Vnf Port Operational StatusMonitors the AdvaENS Virtual Edge Vnf Port Operational Status. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSVnfPortStateOper : 1.3.6.1.4.1.7950.3.11.8.1.5.1.9 ]

ADVA Ensemble Virtual Edge - Sensor Ext

Description

Monitor the ADVA Ensemble Virtual Edge Sensor Metrics like Temperature, Power and Fan. Validated on Model:advaCots, SysObjectOID::1.3.6.1.4.1.7950.1.1.38.[ ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2 ]

Prerequisites

Device must have support for ADVA-LM-SENSORS-MIB

Supported Metric

Monitor NameMetric NameMetric Display NameUnitDescription
ADVA Ensemble Virtual Edge - Sensor ExtadvaENS_VirtualEdge_TemperatureAdvaENS Virtual Edge TemperatureCelsiusMonitors the AdvaENS Virtual Edge Temperature. [ ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2 ]
advaENS_VirtualEdge_FanAdvaENS Virtual Edge FanrpmMonitors the AdvaENS Virtual Edge Fan. [ ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2 ]
advaENS_VirtualEdge_PowerAdvaENS Virtual Edge PowervMonitors the AdvaENS Virtual Edge Power. [ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2]