ADVA Ensemble Virtual Edge - Performance
Description
Monitors the ADVA Ensemble Virtual Edge Performance Statistics like CPU Load Average In 5 Minutes, Cpu Utilization and Memory Usage. Validated on Model:advaCots, SysObjectOID::1.3.6.1.4.1.7950.1.1.38.[ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCpuLoadAverage5Min : 1.3.6.1.4.1.7950.3.11.1.2.5.1.7, advaENSCPUUtilization : 1.3.6.1.4.1.7950.3.11.1.2.9.1.10 , advaENSMemoryUsage : 1.3.6.1.4.1.7950.3.11.1.2.9.1.3 ,advaENSFileSystemUsed : 1.3.6.1.4.1.7950.3.11.1.2.8.1.4 , advaENSFileSystemAvailable : 1.3.6.1.4.1.7950.3.11.1.2.8.1.5 , advaENSFileSystemUse : 1.3.6.1.4.1.7950.3.11.1.2.8.1.6]
Prerequisites
Device must have support for ADVA-ENS-SYSTEM-INVENTORY-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
ADVA Ensemble Virtual Edge - CPU Load | advaENS_VirtualEdge_CpuLoadAverage5Min | AdvaENS Virtual Edge Cpu Load Average 5Minutes | Monitors the AdvaENS CPU Load Average in the last 5 minutes period. [ ADVA-ENS-SYSTEM-INVENTORY-MIB -MIB :: advaENSCpuLoadAverage5Min : 1.3.6.1.4.1.7950.3.11.1.2.5.1.7 ] | |
advaENS_VirtualEdge_PhysicalCPUs | AdvaENS Virtual Edge Physical CPUs | Monitors the AdvaENS Virtual Edge Number of CPUs. [ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCpuPhysicalCPUs : 1.3.6.1.4.1.7950.3.11.1.2.5.1.10] | ||
advaENS_VirtualEdge_CpuCoreThreads | AdvaENS VirtualEdge Cpu Core Threads | Threads | Monitors the AdvaENS VirtualEdge Cpu Core Threadsif hyper threading is enabled. Possible Values are 1: true ; 2: false [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCpuHyperThreading : 1.3.6.1.4.1.7950.3.11.1.2.5.1.9 ]. | |
ADVA Ensemble Virtual Edge - CPU Utilization | advaENS_VirtualEdge_CpuUtilization | AdvaENS Virtual Edge Cpu Utilization | % | Monitors theAdva ENS Virtual Edge CPU Utilization. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSCPUUtilization : 1.3.6.1.4.1.7950.3.11.1.2.9.1.10 ] |
ADVA Ensemble Virtual Edge - File System | advaENS_VirtualEdge_FileSystemUtilization | AdvaENS Virtual Edge File System Utilization | % | Monitors the AdvaENS Virtual Edge File System Utilization. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemUse : 1.3.6.1.4.1.7950.3.11.1.2.8.1.6 ] |
advaENS_VirtualEdge_FileSystemUsed | AdvaENS Virtual Edge File System Used | MB | Monitors the AdvaENS Virtual Edge File System Used. [ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemUsed : 1.3.6.1.4.1.7950.3.11.1.2.8.1.4 ] | |
advaENS_VirtualEdge_FileSystemAvailable | AdvaENS Virtual Edge File System Available | MB | Monitors the AdvaENS Virtual Edge File System Available.[ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSFileSystemAvailable : 1.3.6.1.4.1.7950.3.11.1.2.8.1.5 ] | |
ADVA Ensemble Virtual Edge - Memory Usage | advaENS_VirtualEdge_MemoryMgmtUsage | AdvaENS Virtual Edge Memory Mgmt Usage | % | Monitors AdvaENS Virtual Edge Percent of Memory Mgmt Usage.[ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSMemoryMgmtUsage : 1.3.6.1.4.1.7950.3.11.1.2.6.1.7 ] |
advaENS_VirtualEdge_MemoryMgmt | AdvaENS Virtual Edge Memory for Mgmt | KB | Monitors the AdvaENS Virtual Edge Memory for Mgmt in KB [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSMemoryMgmt : 1.3.6.1.4.1.7950.3.11.1.2.6.1.4 ] |
ADVA Ensemble Virtual Edge - Hardware
Description
Monitors the ADVA Ensemble Virtual Edge Hardware Metrics like Current Temperature, Temperature Status, Current Voltage, Voltage Status, Current Tx Power, Tx Power Status, Current Rx Power, Rx Power Status. Validated on Model:advaCots, SysObjectOID::1.3.6.1.4.1.7950.1.1.38.[ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.12, advaENSSFPTempStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.13, advaENSSFPVoltageCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.16 , advaENSSFPVoltageStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.17, advaENSSFPTxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.24 , advaENSSFPTxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.25 , advaENSSFPRxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.28 , advaENSSFPRxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.29 ]
Prerequisites
Device must have support for ADVA-ENS-SYSTEM-INVENTORY-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
ADVA Ensemble Virtual Edge - Hardware | advaENS_VirtualEdge_SFPTempCurrent | AdvaENS Virtual Edge SFP Temperature Current | Celsius | Monitors the AdvaENS SFP Virtual Edge Temperature Current. [ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.12] |
advaENS_VirtualEdge_SFPTempStatus | AdvaENS Virtual Edge SFP Temperature Status | Monitors the AdvaENS VirtualEdge SFP Temperature Status. Alert will be generated when SFP Temperature Status is "NOT OK". [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTempStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.13 ] | ||
advaENS_VirtualEdge_SFPVoltageCurrent | AdvaENS Virtual Edge SFP Voltage Current | v | Monitors the AdvaENS Virtual Edge SFP Voltage Current Current. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPVoltageCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.16 ] | |
advaENS_VirtualEdge_SFPVoltageStatus | AdvaENS Virtual Edge SFP Voltage Status | Monitors the AdvaENS Virtual Edge SFP Voltage Status. Alert will be generated when SFP Voltage Status is "NOT OK". [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPVoltageStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.17 ] | ||
advaENS_VirtualEdge_SFPTxPowerCurrent | AdvaENS Virtual Edge SFP Tx Power Current | dBm | Monitors the AdvaENS Virtual Edge SFP Tx Power Current. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.24 ] | |
advaENS_VirtualEdge_SFPTxPowerStatus | AdvaENS Virtual Edge SFP Tx Power Status | Monitors the AdvaENS VirtualEdge SFP Tx Power Status. Alert will be generated when SFP Tx Power Status is "NOT OK". [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPTxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.25 ] | ||
advaENS_VirtualEdge_SFPRxPowerCurrent | AdvaENS Virtual Edge SFP Rx Power Current | dBm | Monitors the AdvaENS VirtualEdge SFP Rx Power Current. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPRxPowerCurrent : 1.3.6.1.4.1.7950.3.11.1.2.23.1.28 ] | |
advaENS_VirtualEdge_SFPRxPowerStatus | AdvaENS Virtual Edge SFP Rx Power Status | Monitors the AdvaENS Virtual Edge SFP Rx Power Status. Alert will be generated when SFP Rx Power Status. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSSFPRxPowerStatus : 1.3.6.1.4.1.7950.3.11.1.2.23.1.29 ] |
ADVA Ensemble Virtual Edge - Vnf
Description
Monitors the ADVA Ensemble Virtual Edge Vnf Metrics like Operational Status, Vnf State, Memory Usage and Vnf Port Operational Status. Validated on Model:advaCots, SysObjectOID::1.3.6.1.4.1.7950.1.1.38.[ ADVA-ENS-VNF-MIB :: advaENSVnfStateOper : 1.3.6.1.4.1.7950.3.11.8.1.3.1.12 , advaENSVnfState : 1.3.6.1.4.1.7950.3.11.8.1.3.1.3 , advaENSVnfStateMemorUsage : 1.3.6.1.4.1.7950.3.11.8.1.3.1.13, advaENSVnfPortStateOper : 1.3.6.1.4.1.7950.3.11.8.1.5.1.9 ]
Prerequisites
Device must have support for ADVA-ENS-VNF-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
ADVA Ensemble Virtual Edge - Vnf | advaENS_VirtualEdge_VnfState | AdvaENS Virtual Edge Vnf State | Monitors the AdvaENS Virtual Edge Vnf State. Possible values are 1: shutdown, 2: running, 3: crashed, 4: failed, 5: paused, 6: unknown. [ ADVA-ENS-VNF-MIB :: advaENSVnfState : 1.3.6.1.4.1.7950.3.11.8.1.3.1.3 ] | |
advaENS_VirtualEdge_VnfStateOper | AdvaENS Virtual Edge Vnf Operational Status | Monitors the AdvaENS Virtual Edge Vnf Operational Status. [ ADVA-ENS-VNF-MIB :: advaENSVnfStateOper : 1.3.6.1.4.1.7950.3.11.8.1.3.1.12 ] | ||
advaENS_VirtualEdge_VnfStateMemorUsage | AdvaENS Virtual Edge Vnf State Memor Usage | % | Monitors the AdvaENS Virtual Edge Vnf State Memor Usage. [ ADVA-ENS-VNF-MIB :: advaENSVnfStateMemorUsage : 1.3.6.1.4.1.7950.3.11.8.1.3.1.13 ] | |
ADVA Ensemble Virtual Edge - Vnf Port State | advaENS_VirtualEdge_VnfPortStateOper | AdvaENS Virtual Edge Vnf Port Operational Status | Monitors the AdvaENS Virtual Edge Vnf Port Operational Status. [ ADVA-ENS-SYSTEM-INVENTORY-MIB :: advaENSVnfPortStateOper : 1.3.6.1.4.1.7950.3.11.8.1.5.1.9 ] |
ADVA Ensemble Virtual Edge - Sensor Ext
Description
Monitor the ADVA Ensemble Virtual Edge Sensor Metrics like Temperature, Power and Fan. Validated on Model:advaCots, SysObjectOID::1.3.6.1.4.1.7950.1.1.38.[ ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2 ]
Prerequisites
Device must have support for ADVA-LM-SENSORS-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
ADVA Ensemble Virtual Edge - Sensor Ext | advaENS_VirtualEdge_Temperature | AdvaENS Virtual Edge Temperature | Celsius | Monitors the AdvaENS Virtual Edge Temperature. [ ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2 ] |
advaENS_VirtualEdge_Fan | AdvaENS Virtual Edge Fan | rpm | Monitors the AdvaENS Virtual Edge Fan. [ ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2 ] | |
advaENS_VirtualEdge_Power | AdvaENS Virtual Edge Power | v | Monitors the AdvaENS Virtual Edge Power. [ADVA-LM-SENSORS-MIB :: advaLmSensorDeviceInfo : 1.3.6.1.4.1.7950.3.100.2.3.1.2] |